Aims. The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients. Patients and Methods. A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications. Results. The mean lengthening was 4.65 cm (1.5 to 8) in the antegrade group and 4.64 cm (1.6 to 8) in the retrograde group. Of the 107 lengthenings, 100 had sufficient datapoints to calculate the mean HI. This was 31.6 days/cm (15 to 108). There was a trend toward a lower (better) HI with an antegrade nail and better outcomes in adolescent patients, but these were not statistically significant. Hip and knee ROM was maintained and/or improved following commencement of femoral lengthening in 44 patients (60%) of antegrade nails and 13 patients (38%) of retrograde nails. In female patients, loss of movement occurred both earlier and following less total length achieved. Minor implant complications included locking bolt migration and in one patient deformity of the nail, but no implant failed to lengthen and there were no deep infections. Three patients had delayed
Drug therapy forms an integral part of the management
of many orthopaedic conditions. However, many medicines can produce
serious adverse reactions if prescribed inappropriately, either
alone or in combination with other drugs. Often these hazards are
not appreciated. In response to this, the European
The ipsilateral and contralateral fibulae have been used as a vascularised bone graft for loss of tibial bone usually by methods which have involved specialised microvascular techniques to preserve or re-establish the blood supply. We have developed a method of tibialisation of the fibula using the Ilizarov fixator system, ipsilateral vascularised fibular transport (IVFT), and have used it in five patients with massive loss of tibial bone after treatment of an open fracture, infected nonunion or chronic osteomyelitis. All had successful transport, proximal and distal
Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator. A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.Aims
Patients and Methods
Smoking is associated with post-operative complications but smokers
often under-report the amount they smoke. Our objective was to determine
whether a urine dipstick test could be used as a substitute for
quantitative cotinine assays to determine smoking status in patients. Between September 2013 and July 2014 we conducted a prospective
cohort study in which 127 consecutive patients undergoing a planned
foot and ankle arthrodesis or osteotomy were included. Patients
self-reported their smoking status and were classified as: ‘never
smoked’ (61 patients), ‘ex-smoker’ (46 patients), or ‘current smoker’ (20
patients). Urine samples were analysed with cotinine assays and
cotinine dipstick tests.Aims
Patients and Methods
A flexed knee gait is common in patients with bilateral spastic
cerebral palsy and occurs with increased age. There is a risk for
the recurrence of a flexed knee gait when treated in childhood,
and the aim of this study was to investigate whether multilevel
procedures might also be undertaken in adulthood. At a mean of 22.9 months (standard deviation 12.9), after single
event multi level surgery, 3D gait analysis was undertaken pre-
and post-operatively for 37 adult patients with bilateral cerebral
palsy and a fixed knee gait.Aims
Patients and Methods
Computer hexapod assisted orthopaedic surgery (CHAOS), is a method
to achieve the intra-operative correction of long bone deformities
using a hexapod external fixator before definitive internal fixation
with minimally invasive stabilisation techniques. The aims of this study were to determine the reliability of this
method in a consecutive case series of patients undergoing femoral
deformity correction, with a minimum six-month follow-up, to assess
the complications and to define the ideal group of patients for
whom this treatment is appropriate. The medical records and radiographs of all patients who underwent
CHAOS for femoral deformity at our institution between 2005 and
2011 were retrospectively reviewed. Records were available for all
55 consecutive procedures undertaken in 49 patients with a mean
age of 35.6 years (10.9 to 75.3) at the time of surgery.Aims
Patients and Methods
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and toxic shock syndrome (TSS) may occur. We retrospectively reviewed all patients who underwent external
fixation between 1997 and 2012 in our limb lengthening and reconstruction
programme. A total of eight patients (seven female and one male)
with a mean age of 20 years (5 to 45) in which pin/wire track infections
became limb- or life-threatening were identified. Of these, four
were due to TSS and four to NF. Their management is described. A
satisfactory outcome was obtained with early diagnosis and aggressive
medical and surgical treatment. Clinicians caring for patients who have external fixation and
in whom infection has developed should be aware of the possibility
of these more serious complications. Early diagnosis and aggressive
treatment are required in order to obtain a satisfactory outcome. Cite this article:
We evaluated the quality of guidelines on thromboprophylaxis
in orthopaedic surgery by examining how they adhere to validated
methodological standards in their development. A structured review
was performed for guidelines that were published between January
2005 and April 2013 in medical journals or on the Internet. A pre-defined
computerised search was used in MEDLINE, Scopus and Google to identify
the guidelines. The AGREE II assessment tool was used to evaluate
the quality of the guidelines in the study. Seven international and national guidelines were identified.
The overall methodological quality of the individual guidelines
was good. ‘Scope and Purpose’ (median score 98% interquartile range
(IQR)) 86% to 98%) and ‘Clarity of Presentation’ (median score 90%,
IQR 90% to 95%) were the two domains that received the highest scores. ‘Applicability’
(median score 68%, IQR 45% to 75%) and ‘Editorial Independence’
(median score 71%, IQR 68% to 75%) had the lowest scores. These findings reveal that although the overall methodological
quality of guidelines on thromboprophylaxis in orthopaedic surgery
is good, domains within their development, such as ‘Applicability’
and ‘Editorial Independence’, need to be improved. Application of
the AGREE II instrument by the authors of guidelines may improve
the quality of future guidelines and provide increased focus on
aspects of methodology used in their development that are not robust. Cite this article: Bone Joint J 2014;96-B:19–23.
Implant-associated infection is a major source
of morbidity in orthopaedic surgery. There has been extensive research
into the development of materials that prevent biofilm formation,
and hence, reduce the risk of infection. Silver nanoparticle technology
is receiving much interest in the field of orthopaedics for its
antimicrobial properties, and the results of studies to date are
encouraging. Antimicrobial effects have been seen when silver nanoparticles are
used in trauma implants, tumour prostheses, bone cement, and also
when combined with hydroxyapatite coatings. Although there are promising
results with Cite this article:
This paper offers a summary of the ethical guide
for the European orthopaedic community; the full report will be
published in the EFORT Journal. Cite this article:
We report the results of six trauma and orthopaedic
projects to Kenya in the last three years. The aims are to deliver both
a trauma service and teaching within two hospitals; one a district
hospital near Mount Kenya in Nanyuki, the other the largest public
hospital in Kenya in Mombasa. The Kenya Orthopaedic Project team
consists of a wide range of multidisciplinary professionals that
allows the experience to be shared across those specialties. A follow-up
clinic is held three months after each mission to review the patients.
To our knowledge there are no reported outcomes in the literature
for similar projects. A total of 211 operations have been performed and 400 patients
seen during the projects. Most cases were fractures of the lower
limb; we have been able to follow up 163 patients (77%) who underwent
surgical treatment. We reflect on the results so far and discuss
potential improvements for future missions.
Periosteum is important for bone homoeostasis
through the release of bone morphogenetic proteins (BMPs) and their
effect on osteoprogenitor cells. Smoking has an adverse effect on
fracture healing and bone regeneration. The aim of this study was
to evaluate the effect of smoking on the expression of the BMPs
of human periosteum. Real-time polymerase chain reaction was performed
for BMP-2,-4,-6,-7 gene expression in periosteal samples obtained from
45 fractured bones (19 smokers, 26 non-smokers) and 60 non-fractured
bones (21 smokers, 39 non-smokers). A hierarchical model of BMP
gene expression (BMP-2 >
BMP-6 >
BMP-4 >
BMP-7) was demonstrated
in all samples. When smokers and non-smokers were compared, a remarkable
reduction in the gene expression of BMP-2, -4 and -6 was noticed
in smokers. The comparison of fracture and non-fracture groups demonstrated
a higher gene expression of BMP-2, -4 and -7 in the non-fracture
samples. Within the subgroups (fracture and non-fracture), BMP gene
expression in smokers was either lower but without statistical significance
in the majority of BMPs, or similar to that in non-smokers with
regard to BMP-4 in fracture and BMP-7 in non-fracture samples. In
smokers, BMP gene expression of human periosteum was reduced, demonstrating
the effect of smoking at the molecular level by reduction of mRNA
transcription of periosteal BMPs. Among the BMPs studied, BMP-2
gene expression was significantly
Using inaccurate quotations can propagate misleading
information, which might affect the management of patients. The
aim of this study was to determine the predictors of quotation inaccuracy
in the peer-reviewed orthopaedic literature related to the scaphoid.
We randomly selected 100 papers from ten orthopaedic journals. All references
were retrieved in full text when available or otherwise excluded.
Two observers independently rated all quotations from the selected
papers by comparing the claims made by the authors with the data
and expressed opinions of the reference source. A statistical analysis
determined which article-related factors were predictors of quotation
inaccuracy. The mean total inaccuracy rate of the 3840 verified
quotes was 7.6%. There was no correlation between the rate of inaccuracy
and the impact factor of the journal. Multivariable analysis identified
the journal and the type of study (clinical, biomechanical, methodological,
case report or review) as important predictors of the total quotation
inaccuracy rate. We concluded that inaccurate quotations in the peer-reviewed
orthopaedic literature related to the scaphoid were common and slightly
more so for certain journals and certain study types. Authors, reviewers
and editorial staff play an important role in reducing this inaccuracy.
Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest. The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion.
Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult.
Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed.