Advertisement for orthosearch.org.uk
Results 1 - 20 of 98
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 1 | Pages 31 - 39
1 Feb 1960
Shiers LGP

1. The results of twenty-eight "hinge" arthroplasties of the knee are described. 2. Failure was most often due to breaking of the prosthesis. 3. The design of the prosthesis has been modified as a result of experience in cases of mechanical failure. 4. The results suggest that with the use of the modified hinge good results may be obtainable in three out of four cases


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 4 | Pages 553 - 560
1 Nov 1954
Shiers LGP

If conclusions are to be of any value they must be definite and one cannot draw definite conclusions from less than, say, fifty cases followed up for at least five years. However, few surgeons will ever see fifty patients requiring arthroplasty of the knee, let alone operate of them, even in five years. Accordingly, this account of a new approach to the problem of knee arthroplasty is submitted in the hope that other surgeons may care to try it and thereby learn, and thus be able to teach, tile modifications and improvements that all new techniques seem so surely to need


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 1 | Pages 53 - 60
1 Feb 1949
Speed JS Trout PC

1. Arthroplasty of the knee joint should be performed only in carefully selected cases. Criteria for the operation are outlined. 2. In our experience, 70 per cent. of properly selected patients secure good or fair results. An additional 12 per cent., whose anatomical or functional results were classified as poor, preferred the movement which had been gained to ankylosis of the joint. 3. The major functional adaptation of the knee joint takes place during the first five years after arthroplasty. Several patients who had a poor range of movement after one or two years developed an excellent range by the end of five years. 4. Instability, when present, usually became apparent within the first five years. 5. Joints which were still stable at the end of five years usually remained so over a long period of time. Four patients have been traced for twenty to twenty-five years, and three have been traced for over twenty-five years. 6. Since the incidence of ankylosis of the knee joint from gonococcal and pyogenic infections has been reduced by the use of antibiotics, fewer patients are suitable subjects for arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 3 | Pages 300 - 304
1 Aug 1976
Watson Wood H Hill R

Thirty-one patients with rheumatoid arthritis were reviewed after Shiers arthroplasty of the knee joint for which the main indication was intractable pain. Seven patients had the operation done to both knees. This review was done to assess the long-term results two to seven years later. All patients were clinically and radiologically assessed, and our results showed that pain and instability recurred within eighteen months. Thus it is likely that a prosthesis which allows rotation, and in which the bearing surfaces are metal on plastic, will replace the Shiers prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 76 - 87
1 Feb 1969
Platt G Pepler C

1. Stainless steel mould arthroplasty of the knee is described and a ten-year follow-up study of sixty-two operations is reported. Fifty-four were for rheumatoid arthritis and eight for osteoarthritis. 2. Forty-nine of the sixty-two joints retained mobility, six had become ankylosed and five were later arthrodesed ; two limbs were amputated. The forty-nine mobile knees included twenty-seven which were painless at all times, and fourteen in which only an occasional twinge was felt. 3. The range of movement was increased in twenty-two joints as compared with the state before operation, diminished in twelve and unaltered in five. In ten knees measurements before operation were not available. 4. Flexion deformity, swelling, stability and function were improved in a significant number of joints. 5. Patients suffering from active rheumatoid arthritis often found that the joint operated upon no longer took part in generalised flares of the disease


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 765 - 766
1 Jul 2022
Haddad FS Malchau H


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 3 | Pages 505 - 510
1 Aug 1968
Jones GB

1. Forty-five arthroplasties of the knee with the Walldius prosthesis are reported in forty-two patients, thirty-seven with rheumatoid arthritis and five with osteoarthritis. 2. There has been no structural failure of the prosthesis. 3. Sepsis required removal of the prosthesis in three cases, but arthrodesis was obtained in two of the three. 4. Serious loosening of the prosthesis occurred in one case only. Varus deformity occurred in one patient. 5. Radiological evidence of some movement of the prosthesis was present in six other cases but this did not seem to affect function. 6. It is concluded that this operation has a place in the treatment of the more seriously disabled patient, but should not be used when heavy demands are likely to be made on the joint


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 289 - 291
1 Mar 1986
Johnson D Bannister G

In order to define the predisposing factors and outcome of infected arthroplasty of the knee, a retrospective analysis of a consecutive series of 471 knee arthroplasties was performed. There were 23 cases of superficial wound infection and 25 of deep infection. Superficial wound infection alone resulted in a painfree gait, with little limitation of movement. Rheumatoid arthritis, the use of constrained prostheses and the presence of a superficial wound infection, all predisposed to deep infection. Deep infection was eradicated by long-term antibiotics in only two patients in whom skin cover was successfully provided by a gastrocnemius musculocutaneous flap. Excision of a sinus track, wound debridement and exchange arthroplasty were universally unsuccessful. Arthrodesis, however, in 11 out of 12 cases, provided the painfree gait these patients desire


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 787 - 789
1 Nov 1987
Johnson D

A randomised prospective trial was undertaken of antibiotic prophylaxis given at various intervals before inflation of the tourniquet for arthroplasty of the knee. Cefuroxime assays of bone and subcutaneous fat from samples collected throughout the operation demonstrated that an interval of 10 minutes was necessary to obtain adequate prophylaxis. Improvement in the timing of antibiotic prophylaxis may result in a reduction in the incidence of infection


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 812 - 814
1 Nov 1986
Johnson D Houghton T Radford P

Early mobilisation after arthroplasty of the knee sometimes results in wound breakdown. The two commonly used incisions, the anterior midline and the medial parapatellar incisions, were compared in order to determine which had the best potential for wound healing. Study of the cleavage lines around the knee demonstrated that the medial parapatellar incision lies parallel to the lines, whilst the anterior midline incision lies perpendicular to them. In addition, the medial parapatellar wound was found to be subjected to significantly less tension during flexion; after arthroplasty it can be expected to heal faster and to be less liable to disruption during early mobilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 333 - 338
1 Aug 1978
Sheehan J

Arthrodesis of the knee is a simple and safe operation that ensures stability and freedom from pain. But it is achieved at the expense of movement and occasionally of social acceptability. If arthroplasty is to be recommended, the advantages of arthrodesis must be retained, with the added bonus of a functional arc of movement.


The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 1 | Pages 50 - 52
1 Feb 1949
Samson JE

These statistics show that some movement was gained, with good stability and painlessness, in thirty-five of the fifty operations (70 per cent.) and that there was failure, with reankylosis, instability, or persistent pain, in fifteen (30 per cent.).


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 937 - 942
1 Sep 2003
Ackroyd CE


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 339 - 344
1 Aug 1978
Freeman M Todd R Bamert P Day W

The essentially satisfactory results from the ICLH implant as used until 1975 were marred by examples of loosening and sinking of the tibial implant, by patellar pain of varying severity, by wear of the tibial implant caused by fragments of cement and by failure consistently to control the alignment of the leg. This report describes the methods now being used to overcome these complications and gives an account of the success so far achieved.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 682 - 684
1 Nov 1984
Inglis G

A retrospective review of medial compartment arthroplasty in 22 patients (22 knees) is reported. The operations were performed between 1973 and 1978. Eighty-six per cent were rated good or excellent using the knee rating system devised by the Hospital for Special Surgery, New York. Excellent or good results were achieved in six patients who had previously had a high tibial osteotomy. At the time of follow-up significant loosening had not occurred, although progression of patellofemoral disease was noted. This study supports the promising results reported for unicompartmental resurfacing arthroplasty in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 702 - 705
1 Jul 2001
Tanaka N Sakahashi H Sato E Hirose K Ishima T Ishii S

We studied 99 patients who were undergoing total knee arthroplasty (TKA) to determine the optimum protocol for the administration of tranexamic acid (TNA) in order to reduce blood loss. It decreased by more than 40% after the administration of TNA. The haemostatic effect was greatest when TNA was given preoperatively and on deflation of the tourniquet. There was no increase in the incidence of adverse affects in the patients receiving TNA, compared with a control group.

We conclude that two injections of TNA, one given preoperatively and one on deflation of the tourniquet, significantly reduce blood loss without increasing the risk of thromboembolic complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 217 - 223
1 Mar 1988
Mackinnon J Young S Baily R

Since 1974, we have made a prospective study in Bristol of the results of unicompartmental knee replacement using the St Georg sledge prosthesis. A total of 115 knees in 100 patients have been followed up for 2 to 12 years (mean, 4 years 9 months). Results have assessed both by the Bristol knee score and by survivorship studies on the total series of 138 knees. Results were excellent or good in 86% and fair or poor in 14%. The survivorship study (based on a definition of failure which included significant pain or a dissatisfied patient or the need for revision) showed a cumulative success rate of 76.4% at six years, with no further failures after that time. Seven knees have been revised, in most cases for deterioration of the contralateral compartment. The operation is recommended as a satisfactory and durable form of treatment for osteoarthritis affecting a single tibiofemoral compartment.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 859 - 861
1 Sep 1998
Fiddian NJ Blakeway C Kumar A

Total knee arthroplasty (TKR) using a medial capsular approach gives worse results in arthritic knees with valgus deformity than in those in varus, usually because of swelling, poor wound healing and stiffness, instability, recurrent valgus deformity and poor patellar tracking. A technique for replacement TKR of valgus knees using a lateral capsular approach was described several years ago, but was not routinely adopted because of the difficulties with and complexity of the procedure which included deliberate elevation of the tibial tubercle. In order to avoid this we have modified and simplified the procedure. Our preliminary results suggest that this lateral approach is safe and may give a better outcome than that through the medial capsule for the replacement of valgus knees


The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 6 - 10
1 Jan 2018
Lovelock TM Broughton NS

The number of arthroplasties of the hip and knee is predicted to increase rapidly during the next 20 years. Accompanying this is the dilemma of how to follow-up these patients appropriately. Current guidelines recommend long-term follow-up to identify patients with aseptic loosening, which can occur more than a decade postoperatively. The current guidelines and practices of orthopaedic surgeons vary widely. Existing models take up much clinical time and are expensive. Pilot studies using ‘virtual’ clinics and advanced-practice physiotherapists have shown promise in decreasing the time and costs for orthopaedic surgeons and patients.

This review discusses current practices and future trends in the follow-up of patients who have an arthroplasty.

Cite this article: Bone Joint J 2018;100-B:6–10.