Advertisement for orthosearch.org.uk
Results 1 - 20 of 75
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 15 - 18
1 Jan 2002
Whelan DB Bhandari M McKee MD Guyatt GH Kreder HJ Stephen D Schemitsch EH

The reliability of the radiological assessment of the healing of tibial fractures remains undetermined. We examined the inter- and intraobserver agreement of the healing of such fractures among four orthopaedic trauma surgeons who, on two separate occasions eight weeks apart, independently assessed the radiographs of 30 patients with fractures of the tibial shaft which had been treated by intramedullary fixation. The radiographs were selected from a database to represent fractures at various stages of healing. For each radiograph, the surgeon scored the degree of union, quantified the number of cortices bridged by callus or with a visible fracture line, described the extent and quality of the callus, and provided an overall rating of healing. The interobserver chance-corrected agreement using a quadratically weighted kappa (κ) statistic in which values of 0.61 to 0.80 represented substantial agreement were as follows: radiological union scale (κ = 0.60); number of cortices bridged by callus (κ = 0.75); number of cortices with a visible fracture line (κ = 0.70); the extent of the callus (κ = 0.57); and general impression of fracture healing (κ = 0.67). The intraobserver agreement of the overall impression of healing (κ = 0.89) and the number of cortices bridged by callus (κ = 0.82) or with a visible fracture line (κ = 0.83) was almost perfect. There are no validated scales which allow surgeons to grade fracture healing radiologically. Among those examined, the number of cortices bridged by bone appears to be a reliable, and easily measured radiological variable to assess the healing of fractures after intramedullary fixation


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1266 - 1272
1 Nov 2022
Farrow L Brasnic L Martin C Ward K Adam K Hall AJ Clement ND MacLullich AMJ

Aims. The aim of this study was to examine perioperative blood transfusion practice, and associations with clinical outcomes, in a national cohort of hip fracture patients. Methods. A retrospective cohort study was undertaken using linked data from the Scottish Hip Fracture Audit and the Scottish National Blood Transfusion Service between May 2016 and December 2020. All patients aged ≥ 50 years admitted to a Scottish hospital with a hip fracture were included. Assessment of the factors independently associated with red blood cell transfusion (RBCT) during admission was performed, alongside determination of the association between RBCT and hip fracture outcomes. Results. A total of 23,266 individual patient records from 18 hospitals were included. The overall rate of blood transfusion during admission was 28.7% (n = 6,685). There was inter-hospital variation in transfusion rate, ranging from 16.6% to 37.4%. Independent perioperative factors significantly associated with RBCT included older age (90 to 94 years, odds ratio (OR) 3.04 (95% confidence interval (CI) 2.28 to 4.04); p < 0.001), intramedullary fixation (OR 7.15 (95% CI 6.50 to 7.86); p < 0.001), and sliding hip screw constructs (OR 2.34 (95% CI 2.19 to 2.50); p < 0.001). Blood transfusion during admission was significantly associated with higher rates of 30-day mortality (OR 1.35 (95% CI 1.19 to 1.53); p < 0.001) and 60-day mortality (OR 1.54 (95% CI 1.43 to 1.67); p < 0.001), as well as delays to postoperative mobilization, higher likelihood of not returning to their home, and longer length of stay. Conclusion. Blood transfusion after hip fracture was common, although practice varied nationally. RBCT is associated with adverse outcomes, which is most likely a reflection of perioperative anaemia, rather than any causal effect. Use of RBCT does not appear to reverse this effect, highlighting the importance of perioperative blood loss reduction. Cite this article: Bone Joint J 2022;104-B(11):1266–1272


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1592 - 1595
1 Nov 2010
Ahmed I Robinson CM Patton JT Cook RE

We present two cases of metastatic lung cancer which occurred at the site of a previously united tibial fracture. Both patients were treated with a locked intramedullary nail. The patients presented with metastases at the site of their initial fracture approximately 16 and 13 months after injury respectively.

We discuss this unusual presentation and review the relevant literature. We are unaware of any previous reports of a metastatic tumour occurring at the site of an orthopaedic implant used to stabilise a non-pathological fracture. These cases demonstrate the similar clinical presentation of infection and malignancy: a diagnosis which should always be considered in such patients.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1234 - 1240
1 Sep 2018
Brady J Hardy BM Yoshino O Buxton A Quail A Balogh ZJ

Aims. Little is known about the effect of haemorrhagic shock and resuscitation on fracture healing. This study used a rabbit model with a femoral osteotomy and fixation to examine this relationship. Materials and Methods. A total of 18 male New Zealand white rabbits underwent femoral osteotomy with intramedullary fixation with ‘shock’ (n = 9) and control (n = 9) groups. Shock was induced in the study group by removal of 35% of the total blood volume 45 minutes before resuscitation with blood and crystalloid. Fracture healing was monitored for eight weeks using serum markers of healing and radiographs. Results. Four animals were excluded due to postoperative complications. The serum concentration of osteocalcin was significantly elevated in the shock group postoperatively (p < 0.0001). There were otherwise no differences with regard to serum markers of bone healing. The callus index was consistently increased in the shock group on anteroposterior (p = 0.0069) and lateral (p = 0.0165) radiographs from three weeks postoperatively. The control group showed an earlier decrease of callus index. Radiographic scores were significantly greater in the control group (p = 0.0025). Conclusion. In a rabbit femoral osteotomy model with intramedullary fixation, haemorrhagic shock and resuscitation produced larger callus but with evidence of delayed remodelling. Cite this article: Bone Joint J 2018;100-B:1234–40


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1263 - 1271
1 Oct 2019
Eisenschenk A Spitzmüller R Güthoff C Obladen A Kim S Henning E Dornberger JE Stengel D

Aims. The aim of this study was to investigate whether clinical and radiological outcomes after intramedullary nailing of displaced fractures of the fifth metacarpal neck using a single thick Kirschner wire (K-wire) are noninferior to those of technically more demanding fixation with two thinner dual wires. Patients and Methods. This was a multicentre, parallel group, randomized controlled noninferiority trial conducted at 12 tertiary trauma centres in Germany. A total of 290 patients with acute displaced fractures of the fifth metacarpal neck were randomized to either intramedullary single-wire (n = 146) or dual-wire fixation (n = 144). The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire six months after surgery, with a third of the minimal clinically important difference (MCID) used as the noninferiority threshold. Secondary outcomes were pain, health-related quality of life (EuroQol five-dimensional questionnaire (EQ-5D)), radiological measures, functional deficits, and complications. Results. Overall, 151/290 of patients (52%) completed the six months of follow-up, leaving 83 patients in the single-wire group and 68 patients in the dual-wire group. In the modified intention-to-treat analysis set, mean DASH scores six months after surgery were 3.8 (. sd. 7.0) and 4.4 (. sd. 9.4), respectively. With multiple imputation (n = 288), mean DASH scores were estimated at 6.3 (. sd. 8.7) and 7.0 (. sd. 10.0). Upper (1 - 2α)) confidence limits consistently remained below the noninferiority margin of 3.0 points in the DASH instrument. While there was a statistically nonsignificant trend towards a higher rate of shortening and rotational malalignment in the single wire group, no statistically significant differences were observed across groups in any secondary outcome measure. Conclusion. A single thick K-wire is sufficient for intramedullary fixation of acute displaced subcapital fractures of the fifth metacarpal neck. The less technically demanding single-wire technique produces noninferior clinical and radiological outcomes compared with the dual-wire approach. Cite this article: Bone Joint J 2019;101-B:1263–1271


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 22 - 25
1 Nov 2012
Haidukewych GJ

Many tumors metastasise to bone, therefore, pathologic fracture and impending pathologic fractures are common reasons for orthopedic consultation. Having effective treatment strategies is important to avoid complications, and relieve pain and preserve function. Thorough pre-operative evaluation is recommended for medical optimization and to ensure that the lesion is in fact a metastasis and not a primary bone malignancy. For impending fractures, various scoring systems have been proposed to determine the risk of fracture, and therefore the need for prophylactic stabilisation. Lower score lesions can often be treated with radiation, while more problematic lesions may require internal fixation. Intramedullary fixation is generally preferred due to favorable biomechanics. Arthroplasty may be required for lesions with massive bony destruction where internal fixation attempts are likely to fail. Radiation may also be useful postoperatively to minimise construct failure due to tumor progression


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 536 - 540
1 Apr 2006
Vallamshetla VRP De Silva U Bache CE Gibbons PJ

Flexible intramedullary nailing is gaining popularity as an effective method of treating long-bone fractures in children. We retrospectively reviewed the records and radiographs of 56 unstable fractures of the tibia in 54 children treated between March 1997 and May 2005. All were followed up for at least two months after the removal of the nails. Of the 56 tibial fractures, 13 were open. There were no nonunions. The mean time to clinical and radiological union was ten weeks. Complications included residual angulation of the tibia, leg-length discrepancy, deep infection and failures of fixation. All achieved an excellent functional outcome. We conclude that flexible intramedullary fixation is an easy and effective method of management of both open and closed unstable fractures of the tibia in children


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1485 - 1492
1 Dec 2024
Terek RM

Aims

The aim of the LightFix Trial was to evaluate the clinical outcomes for one year after the treatment of impending and completed pathological fractures of the humerus using the IlluminOss System (IS), and to analyze the performance of this device.

Methods

A total of 81 patients with an impending or completed pathological fracture were enrolled in a multicentre, open label single cohort study and treated with IS. Inclusion criteria were visual analogue scale (VAS) Pain Scores > 60 mm/100 mm and Mirels’ Score ≥ 8. VAS pain, Musculoskeletal Tumor Society (MSTS) Upper Limb Function, and The European Organization for Research and Treatment of Cancer QoL Group Bone Metastases Module (QLQ-BM22) scores were all normalized to 100, and radiographs were obtained at baseline and at 14, 30, 90, 180, and 360 days postoperatively.


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 593 - 601
1 Jun 2023
Scott CEH Yapp LZ Howard T Patton JT Moran M

Periprosthetic femoral fractures are increasing in incidence, and typically occur in frail elderly patients. They are similar to pathological fractures in many ways. The aims of treatment are the same, including 'getting it right first time' with a single operation, which allows immediate unrestricted weightbearing, with a low risk of complications, and one that avoids the creation of stress risers locally that may predispose to further peri-implant fracture. The surgical approach to these fractures, the associated soft-tissue handling, and exposure of the fracture are key elements in minimizing the high rate of complications. This annotation describes the approaches to the femur that can be used to facilitate the surgical management of peri- and interprosthetic fractures of the femur at all levels using either modern methods of fixation or revision arthroplasty.

Cite this article: Bone Joint J 2023;105-B(6):593–601.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1248 - 1252
1 Sep 2016
White TO Bugler KE Appleton P Will† E McQueen MM Court-Brown CM

Aims. The fundamental concept of open reduction and internal fixation (ORIF) of ankle fractures has not changed appreciably since the 1960s and, whilst widely used, is associated with complications including wound dehiscence and infection, prominent hardware and failure. Closed reduction and intramedullary fixation (CRIF) using a fibular nail, wires or screws is biomechanically stronger, requires minimal incisions, and has low-profile hardware. We hypothesised that fibular nailing in the elderly would have similar functional outcomes to standard fixation, with a reduced rate of wound and hardware problems. Patients and Methods. A total of 100 patients (25 men, 75 women) over the age of 65 years with unstable ankle fractures were randomised to undergo standard ORIF or fibular nailing (11 men and 39 women in the ORIF group, 14 men and 36 women in the fibular nail group). The mean age was 74 years (65 to 93) and all patients had at least one medical comorbidity. Complications, patient related outcome measures and cost-effectiveness were assessed over 12 months. Results. Significantly fewer wound infections occurred in the fibular nail group (p = 0.002). At one year, there was no evidence of difference in mean functional scores (Olerud and Molander Scores 63; 30 to 85, versus 61; 10 to 35, p = 0.61) or scar satisfaction. The overall cost of treatment in the fibular nail group was £91 less than in the ORIF group despite the higher initial cost of the implant. Conclusion. We conclude that the fibular nail allows accurate reduction and secure fixation of ankle fractures, with a significantly lower rate of soft-tissue complications, and is more cost-effective than ORIF. Cite this article: Bone Joint J 2016;98-B:1248–52


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims

Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined.

Methods

This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up.


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 112 - 123
1 Feb 2023
Duckworth AD Carter TH Chen MJ Gardner MJ Watts AC

Despite being one of the most common injuries around the elbow, the optimal treatment of olecranon fractures is far from established and stimulates debate among both general orthopaedic trauma surgeons and upper limb specialists. It is almost universally accepted that stable non-displaced fractures can be safely treated nonoperatively with minimal specialist input. Internal fixation is recommended for the vast majority of displaced fractures, with a range of techniques and implants to choose from. However, there is concern regarding the complication rates, largely related to symptomatic metalwork resulting in high rates of implant removal. As the number of elderly patients sustaining these injuries increases, we are becoming more aware of the issues associated with fixation in osteoporotic bone and the often fragile soft-tissue envelope in this group. Given this, there is evidence to support an increasing role for nonoperative management in this high-risk demographic group, even in those presenting with displaced and/or multifragmentary fracture patterns. This review summarizes the available literature to date, focusing predominantly on the management techniques and available implants for stable fractures of the olecranon. It also offers some insights into the potential avenues for future research, in the hope of addressing some of the pertinent questions that remain unanswered.

Cite this article: Bone Joint J 2023;105-B(2):112–123.


The Bone & Joint Journal
Vol. 106-B, Issue 9 | Pages 942 - 948
1 Sep 2024
Kingery MT Kadiyala ML Walls R Ganta A Konda SR Egol KA

Aims

This study evaluated the effect of treating clinician speciality on management of zone 2 fifth metatarsal fractures.

Methods

This was a retrospective cohort study of patients with acute zone 2 fifth metatarsal fractures who presented to a single large, urban, academic medical centre between December 2012 and April 2022. Zone 2 was the region of the fifth metatarsal base bordered by the fourth and fifth metatarsal articulation on the oblique radiograph. The proportion of patients allowed to bear weight as tolerated immediately after injury was compared between patients treated by orthopaedic surgeons and podiatrists. The effects of unrestricted weightbearing and foot and/or ankle immobilization on clinical healing were assessed. A total of 487 patients with zone 2 fractures were included (mean age 53.5 years (SD 16.9), mean BMI 27.2 kg/m2 (SD 6.0)) with a mean follow-up duration of 2.57 years (SD 2.64).


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 783 - 788
1 Jun 2014
Kanakaris N Gudipati S Tosounidis T Harwood P Britten S Giannoudis PV

Intramedullary infection in long bones represents a complex clinical challenge, with an increasing incidence due to the increasing use of intramedullary fixation. We report a prospective case series using an intramedullary reaming device, the Reamer–Irrigator–Aspirator (RIA) system, in association with antibiotic cement rods for the treatment of lower limb long bone infections. A total of 24 such patients, 16 men and eight women, with a mean age of 44.5 years (17 to 75), 14 with femoral and 10 with tibial infection, were treated in a staged manner over a period of 2.5 years in a single referral centre. Of these, 21 patients had had previous surgery, usually for fixation of a fracture (seven had sustained an open fracture originally and one had undergone fasciotomies). According to the Cierny–Mader classification system, 18 patients were classified as type 1A, four as 3A (discharging sinus tract), one as type 4A and one as type 1B. Staphylococcus species were isolated in 20 patients (83.3%). Local antibiotic delivery was used in the form of impregnated cement rods in 23 patients. These were removed at a mean of 2.6 months (1 to 5). Pathogen-specific antibiotics were administered systemically for a mean of six weeks (3 to 18). At a mean follow-up of 21 months (8 to 36), 23 patients (96%) had no evidence of recurrent infection. One underwent a planned trans-tibial amputation two weeks post-operatively due to peripheral vascular disease and chronic recalcitrant osteomyelitis of the tibia and foot. The combination of RIA reaming, the administration of systemic pathogen-specific antibiotics and local delivery using impregnated cement rods proved to be a safe and efficient form of treatment in these patients. Cite this article: Bone Joint J 2014; 96-B:783–8


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 581 - 584
1 May 2004
Myers GJC Gibbons PJ Glithero PR

We identified 25 children (10 girls and 15 boys) who had been treated with single bone intramedullary fixation for diaphyseal fractures of both forearm bones. Their mean age was 10.75 years (4.6 to 15.9). All had a good functional outcome. We conclude that in selected children, single bone intramedullary nailing is a suitable method of treatment for diaphyseal fractures of both bones of the forearm


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1174 - 1176
1 Nov 2000
Bidwell JP Bennet GC Bell MJ Witherow PJ

We describe ten patients with Turner’s syndrome (karyotype 45, XO) who had leg lengthening for short stature. A high incidence of postoperative complications was encountered and many patients required intramedullary fixation as a salvage procedure. We discuss the reasons for this and highlight the differences between our findings and those of a similar series recently reported. In view of the considerable difficulties encountered, we do not recommend leg lengthening in Turner’s syndrome


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 454 - 462
1 May 1985
Paterson D Simonis R

A treatment regime using electrical stimulation in association with a variety of surgical procedures has improved the prognosis in congenital pseudarthrosis of the tibia--one of the most challenging of all orthopaedic disorders. The technique consists of correction of the tibial deformity, intramedullary fixation and cancellous bone grafting, augmented by electrical stimulation using an implanted bone-growth stimulator. Experience with 27 pseudarthroses in 25 patients is presented; of those, 20 have joined. The cases have been reviewed and the causes of failure analysed. These results offer encouragement to the orthopaedic surgeon treating this difficult condition


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 3 - 6
1 Feb 1981
Thomas T Meggitt B

A comparative study of methods for treating fractures of the distal half of the femur was carried out prospectively in the five-year period January 1973 to December 1977. The three methods compared were conservative treatment on a Thomas' splint, application of a knee-hinged cast-brace at five to seven weeks, and intramedullary nailing. The time in bed, in hospital and to union were compared as was the rate of functional recovery of the knee. It is concluded that the cast-brace provides a safe reliable method of treatment, combining the advantages of non-operative management with the early mobilisation possible with intramedullary fixation but without the disadvantages of surgical treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 563 - 566
1 Jul 1992
Kumta S Spinner R Leung P

Biodegradable implants made from polyglycolic and polylactic acid co-polymers undergo degradation by hydrolysis which results in loss of their mechanical strength. The degradation of 1.5 mm polyglycolide rods (Biofix) was studied after intramedullary and subcutaneous implantation in rabbits. Two weeks after implantation there was a 73% reduction in strength of the intramedullary implants and a 64% reduction in the subcutaneous implants. Polyglycolide implants were compared with Kirschner wires for intramedullary fixation of extra-articular fractures in the hand. In one group of patients fractures were fixed with a 1.5 mm intramedullary rod and in a similar group a Kirschner wire was used. In both a wire loop was added for extra fixation. At six months there was no significant difference between the two groups. There were no allergic reactions to the polyglycolide implants


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 90 - 94
1 Jan 2003
Takahashi S Kitagawa H Ishii T

Intraoperative pulmonary fat and bone-marrow embolism is a serious complication of bone and joint surgery. We have investigated the occurrence and incidence of intraoperative embolism in patients undergoing elective lumbar spinal surgery with or without instrumentation. Sixty adult patients with lumbar degenerative disease were examined by intraoperative transoesophageal echocardiography while undergoing posterior lumbar surgery. Of these, 40 underwent surgery with instrumentation and 20 without. Moderate to severe (grade 2 or 3 according to the grading scale of Pitto et al) embolic events were seen in 80% of the instrumented patients but in none of the non-instrumented patients (p < 0.001). The insertion of pedicle screws was particularly associated with large numbers of pulmonary emboli, while the surgical approach, laminectomy, disc removal and bone harvesting were associated with small numbers of emboli. We consider that, as in arthroplasty and intramedullary fixation of fractures, these embolic events are relevant to the development of potentially fatal fat embolism during spinal surgery