Aims. Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when
Aims. The aim of this retrospective cohort study was to assess and investigate the safety and efficacy of using a distal tibial osteotomy compared to proximal osteotomy for
Little is known about the increase in length of tendons in postnatal life or of their response to
Ten patients, who were unsuitable for
The response of the muscle is critical in determining the functional outcome of
We performed
We have compared, in rabbits, two techniques of
We report the results of intramedullary leg lengthening conducted between 2002 and 2009 using the Intramedullary Skeletal Kinetic Distractor in 69 unilateral lengthenings involving 58 femora and 11 tibiae. We identified difficulties that occurred during the treatment and assessed whether they were specifically due to the implant or independent of it. Paley’s classification for evaluating problems, obstacles and complications with external fixators was adopted, and implant-specific difficulties were continuously noted. There were seven failures requiring premature removal of the device, in four due to nail breakage and three for other reasons, and five unsuccessful outcomes after completion of the lengthening. In all, 116 difficulties were noted in 45 patients, with only 24 having problem-free courses. In addition to the difficulties arising from the use of external fixators, there were almost the same number again of implant-specific difficulties. Nevertheless, successful femoral lengthening was achieved in 52 of the 58 patients (90%). However, successful tibial lengthening was only achieved in five of 11 patients (45%).
Between October 2001 and September 2009 we lengthened 242 lower-limb segments in 180 patients using the Intramedullary Skeletal Kinetic Distractor (ISKD). Mechanical failure was defined either as breakage of the ISKD or failure of the internal mechanism to activate. Retrieved nails which failed mechanically were examined by the manufacturer for defects. In all, 15 ISKDs in 12 patients (13 limbs) failed mechanically representing an overall failure rate of 6.2%, with fracture of the device occurring in ten of the 15 failures. Two nails in one patient failed to lengthen and had to be replaced. The manufacturer detected an error in the assembly of the nail, which prompted a wide recall. One nail jammed after being forcefully inserted, and two nails failed to lengthen fully. Lengthening was achieved in all 12 patients, although three required a second operation to exchange a defective nail for a new, functioning device. The ISKD is a complex mechanical device which lengthens by the oscillation of two telescopic sections connected by a threaded rod. The junction between these sections is surrounded by a keyring collar. This keyring collar is the weakest part of the device.
We describe a technique for slow, progressive, symmetrical distraction of the growth plate using a lightweight dynamic axial fixation system. Results are given for the elongation of 40 bony segments in children with limb-length discrepancies and 60 segments in children with achondroplasia or hypochondroplasia. Increases in limb length of up to 36% were obtained in non-achondroplastic and up to 64.5% in achondroplastic patients. There were no nerve or vascular lesions or bony infections and no case required a bone graft. Pin-track complications occurred in only 1.5%.
Until recently the accepted treatment of choice for severe type-II fibular hemimelia has been Syme’s or Boyd’s amputation. The alternative of distraction lengthening using the Ilizarov technique is now available. We report three patients (four limbs) with type-II fibular hemimelia who were treated by the Ilizarov technique and followed up for two to six years. Severe progressive procurvatum and valgus deformity of the tibia and valgus deformity and lateral subluxation of the ankle were found in all four limbs. Multiple additional soft-tissue and bony surgery was necessary. In view of these problems we feel that reappraisal of the indications for lengthening in type-II fibular hemimelia is necessary.
We present the results of 13 patients who suffered severe injuries to the lower leg. Five sustained a traumatic amputation and eight a Gustilo-Anderson type IIIC open fracture. All were treated with debridement, acute shortening and stabilisation of the fracture and vascular reconstruction. Further treatment involved restoration of tibial length by callus distraction through the distal or proximal metaphysis, which was commenced soon after the soft tissues had healed (n = 8) or delayed until union of the fracture (n = 5). All patients were male with a mean age of 28.4 years (17 to 44), and had sustained injury to the leg only. Chen grade II functional status was achieved in all patients. Although the number of patients treated with each strategy was limited, there was no obvious disadvantage in the early lengthening programme, which was completed more quickly.
We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening.
The Ilizarov method for leg lengthening was used for cosmetic reasons in 54 patients with constitutional short stature. A mean lengthening of 7 cm with a low rate of complications produced an excellent or good outcome in all the patients, including improvement in psychological disturbances related to short stature. Those who undergo the procedure must be highly motivated, fully informed and understand the technique and possible complications. We suggest that the Ilizarov method for cosmetic
This study evaluated the effect of limb lengthening
on longitudinal growth in patients with achondroplasia. Growth of
the lower extremity was assessed retrospectively by serial radiographs
in 35 skeletally immature patients with achondroplasia who underwent
bilateral