We studied wear in the ultra-high-molecular-weight polyethylene
The aim of this study was to evaluate the healthcare costs and benefits of enoxaparin compared to aspirin in the prevention of symptomatic venous thromboembolism (VTE) after total hip arthroplasty (THA) or total knee arthroplasty (TKA) using data from the CRISTAL trial. This trial-based economic analysis reports value for money as incremental cost per quality-adjusted life-year (QALY) gained in 2022 Australian dollars, compared to a single threshold value of AUD$70,000 per QALY. Event costs were estimated based on occurrence of VTEs and bleeds, and on published guidelines for treatment. Unit costs were taken from Australian sources. QALYs were estimated using CRISTAL six-month follow-up data. Sensitivity analyses are presented that vary the cost of VTE treatment, and extend the analyses to two years.Aims
Methods
Aims. We investigated changes in the axial alignment of the ipsilateral
hip and knee after total hip arthroplasty (THA). . Patients and Methods. We reviewed 152 patients undergoing primary THA (163 hips; 22
hips in men, 141 hips in women) without a pre-operative flexion
contracture. The mean age was 64 years (30 to 88). The diagnosis
was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary
to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach
with repair of the external rotators was used in 134 hips and an
anterior approach in 29 hips. We measured changes in leg length
and
Total knee arthroplasty (TKA) and total hip arthroplasty
(THA) are recognised and proven interventions for patients with
advanced arthritis. Studies to date have demonstrated a steady increase
in the requirement for primary and revision procedures. Projected
estimates made for the United States show that by 2030 the demand
for primary TKA will grow by 673% and for revision TKA by 601% from
the level in 2005. For THA the projected estimates are 174% and
137% for primary and revision surgery, respectively. The purpose
of this study was to see if those predictions were similar for England
and Wales using data from the National Joint Registry and the Office
of National Statistics. Analysis of data for England and Wales suggest that by 2030,
the volume of primary and revision TKAs will have increased by 117%
and 332%, respectively between 2012 and 2030. The data for the United
States translates to a 306% cumulative rate of increase between
2012 and 2030 for revision surgery, which is similar to our predictions
for England and Wales. The predictions from the United States for primary TKA were similar
to our upper limit projections. For THA, we predicted an increase
of 134% and 31% for primary and revision hip surgery, respectively. Our model has limitations, however, it highlights the economic
burden of arthroplasty in the future in England and Wales as a real
and unaddressed problem. This will have significant implications
for the provision of health care and the management of orthopaedic
services in the future. Cite this article:
We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value. Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p <
0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.
A new generation of knee prostheses has been introduced with the intention of improving post-operative knee flexion. In order to evaluate whether this goal has been achieved we performed a systematic review and meta-analysis. Systematic literature searches were conducted on MEDLINE and EMBASE from their inception to December 2007, and proceedings of scientific meetings were also searched. Only randomised, clinical trials were included in the meta-analysis. The mean difference in the maximum post-operative flexion between the ‘high-flex’ and conventional types of prosthesis was defined as the primary outcome measure. A total of five relevant articles was identified. Analysis of these trials suggested that no clinically relevant or statistically significant improvement was obtained in flexion with the ‘high-flex’ prostheses. The weighted mean difference was 2.1° (95% confidence interval −0.2 to +4.3; p = 0.07).
Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by ‘reverse calibration’ of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere. The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs.