Aims. A recent study used the RAND Corporation at University of California, Los Angeles (RAND/UCLA) method to develop anatomical total shoulder arthroplasty (aTSA) appropriateness criteria. The purpose of our study was to determine how patient-reported outcome measures (PROMs) vary based on appropriateness. Methods. Clinical data from a multicentre database identified patients who underwent primary aTSA from November 2004 to January 2023. A total of 390 patients (mean follow-up 48.1 months (SD 42.0)) were included: 97 (24.9%) were classified as appropriate, 218 (55.9%) inconclusive, and 75 (19.2%) inappropriate. Patients were classified as “appropriate”, “inconclusive”, or “inappropriate”, using a modified version of an appropriateness algorithm, which accounted for age, rotator cuff status, mobility, symptomatology, and Walch classification. Multiple pre- and postoperative scores were analyzed using Pearson’s chi-squared test and one-way analysis of variance (ANOVA). Postoperative complications were also analyzed. Results. All groups achieved significant improvement in mean PROM scores postoperatively. “Appropriate” patients experienced significantly greater improvement in visual analogue scale (VAS) and American Shoulder and Elbow Surgeons (ASES) score compared to “inconclusive” and “inappropriate”. The appropriate group had a significantly greater proportion of patients who achieved minimal clinically important difference (MCID) (95.8%; n = 93) and substantial clinical benefit (SCB) (92.6%; n = 89). Overall, 13 patients had postoperative complications. No significant differences in postoperative complications among classifications were found. Conclusion. Our data clinically validate the RAND/UCLA aTSA appropriateness criteria algorithm, allowing for more rapid and reliable determination of aTSA candidacy. “Appropriate” patients were more likely to achieve MCID and SCB for ASES scores compared to “inappropriate” patients. Among “appropriate” patients who did not achieve SCB, 50% (n = 4) had a postoperative complication. There was a significantly higher proportion of postoperative complications among those who did not achieve SCB across all three groups. Only 7.1% (n = 1) of patients who did not achieve SCB in the inappropriate group had a postoperative complication. Thus, it can be inferred that the failure to reach SCB in the appropriate group was likely to be due to a postoperative complication, whereas for patients deemed “inappropriate”, failure to reach SCB may be secondary to factors accounted for within our algorithm. Cite this article:
Aims. The aim of this audit was to assess and improve the completeness and accuracy of the National Joint Registry (NJR) dataset for arthroplasty of the elbow. Methods. It was performed in two phases. In Phase 1, the completeness was assessed by comparing the NJR elbow dataset with the NHS England Hospital Episode Statistics (HES) data between April 2012 and April 2020. In order to assess the accuracy of the data, the components of each arthroplasty recorded in the NJR were compared to the type of arthroplasty which was recorded. In Phase 2, a national collaborative audit was undertaken to evaluate the reasons for unmatched data, add missing arthroplasties, and evaluate the reasons for the recording of inaccurate arthroplasties and correct them. Results. Phase 1 identified 5,539 arthroplasties in HES which did not match an arthroplasty on the NJR, and 448 inaccurate arthroplasties from 254 hospitals. Most mismatched procedures (3,960 procedures; 71%) were radial head arthroplasties (RHAs). In Phase 2, 142 NHS hospitals with 3,640 (66%) mismatched and 314 (69%) inaccurate arthroplasties volunteered to assess their records. A large proportion of the unmatched data (3,000 arthroplasties; 82%) were confirmed as being missing from the NJR. The overall rate of completeness of the NJR elbow dataset improved from 63% to 83% following phase 2, and the completeness of total elbow arthroplasty data improved to 93%. Missing RHAs had the biggest impact on the overall completeness, but through the audit the number of RHAs in the NJR nearly doubled and completeness increased from 35% to 70%. The accuracy of data was 94% and improved to 98% after correcting 212 of the 448 inaccurately recorded arthroplasties. Conclusion. The rate of completeness of the NJR total elbow arthroplasty dataset is currently 93% and the accuracy is 98%. This audit identified challenges of data capture with regard to RHAs. Collaboration with a trauma and orthopaedic trainees through the British Orthopaedic Trainee Association improved the completeness and accuracy of the NJR elbow dataset, which will improve the validity of the reports and of the associated research. Cite this article:
Aims. The Bankart and Latarjet procedures are two of the most common surgical techniques to treat anterior shoulder instability with satisfactory clinical and functional outcomes. However, the outcomes in the adolescent population remain unclear, and there is no information regarding the arthroscopic Latarjet in this population. The purpose of this study was to evaluate the outcomes of the arthroscopic Bankart and arthroscopic Latarjet procedures in the management of anterior shoulder instability in adolescents. Methods. We present a retrospective, matched-pair study of teenagers with anterior glenohumeral instability treated with an arthroscopic Bankart repair (ABR) or an arthroscopic Latarjet (AL) procedure with a minimum two-year follow-up. Preoperative demographic and clinical features, factors associated with dislocation, and complications were collected. Recurrence, defined as dislocation or subluxation, was established as the primary outcome. Clinical and functional outcomes were analyzed using objective (Rowe), and subjective (Western Ontario Shoulder Instability Index (WOSI) and Single Assessment Numeric Evaluation (SANE)) scores. Additionally, the rate of return to sport was assessed. Results. A total of 51 adolescents were included, of whom 46 (92%) were male, with 17 (33%) in the Latarjet group and 34 (66%) in the Bankart group. The mean age at time of surgery was 18 years (15 to 19). There were no intraoperative complications. At a median follow-up of nine years (IQR 2 to 18), recurrence was observed in 12 patients in the Bankart group (35.3%) and one patient in the Latarjet group (5.9%) (p = 0.023). Satisfactory postoperative outcomes were obtained, with mean Rowe, WOSI, and SANE scores noted at 95 (10 to 100), 325 (25 to 1,975), and 87.5 (10 to 100), respectively. Most patients (29 in the Bankart group (85.3%) and 16 in the Latarjet group (94.1%)) were able to return to sport (p = 0.452). Conclusion. The ABR and AL procedures both obtain satisfactory clinical and functional outcomes in the treatment of anterior glenohumeral instability in adolescents with a low complication rate. However, the ABR is associated with a significantly higher recurrence rate. Cite this article:
Aims. We sought to compare functional outcomes and survival between non-smokers, former smokers, and current smokers who underwent anatomical total shoulder arthroplasty (aTSA) in a large cohort of patients. Methods. A retrospective review of a prospectively collected shoulder arthroplasty database was performed between August 1991 and September 2020 to identify patients who underwent primary aTSA. Patients were excluded for preoperative diagnoses of fracture, infection, or oncological disease. Three cohorts were created based on smoking status: non-smokers, former smokers, and current smokers. Outcome scores (American Shoulder and Elbow Surgeons (ASES), Constant-Murley score, Shoulder Pain and Disability Index (SPADI), Simple Shoulder Test (SST), University of California, Los Angeles activity scale (UCLA)), range of motion (external rotation (ER), forward elevation (FE), internal rotation, abduction), and shoulder strength (ER, FE) evaluated at two- to four-year follow-up were compared between cohorts. Evaluation of revision-free survival was performed using the Kaplan-Meier method to final follow-up. Results. We included 428 primary aTSAs with a mean follow-up of 2.4 years (SD 0.6). Our cohort consisted of 251 non-smokers, 138 former smokers who quit a mean 21 years (SD 14) prior to surgery (25 pack-years (SD 22)), and 39 current smokers (23 pack-years (SD 20)). At two- to four-year follow-up, former smokers had less favourable SPADI, SST, and FE strength compared to non-smokers, and current smokers had less favourable SPADI, SST, ASES score, UCLA score, Constant-Murley score, FE, abduction, and ER strength compared to non-smokers. Non-smokers exhibited higher revision-free survival rates at two, five, eight, and ten years postoperatively compared to former smokers and current smokers, who had similar rates. Conclusion. Our study suggests that smoking has a negative effect on aTSA functional outcomes that may persist even after quitting. Cite this article:
Aims. Reconstruction after osteoarticular resection of the proximal ulna for tumours is technically difficult and little has been written about the options that are available. We report a series of four patients who underwent radial neck to humeral trochlea transposition arthroplasty following proximal ulnar osteoarticular resection. Methods. Between July 2020 and July 2022, four patients with primary bone tumours of the ulna underwent radial neck to humeral trochlea transposition arthroplasty. Their mean age was 28 years (12 to 41). The functional outcome was assessed using the range of motion (ROM) of the elbow, rotation of the forearm and stability of the elbow, the Musculoskeletal Tumor Society score (MSTS), and the nine-item abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH-9) score. Results. All patients were available for follow-up at a mean of 33 months (25 to 43) and were disease-free. The mean flexion arc was 0° to 105°. Three patients had complications. One had neuropraxia of the ulnar nerve. The symptoms resolved after three months. In one patient, the screw used for fixation of the triceps tendon became exposed and was removed, six months postoperatively. One patient with wound dehiscence required a local flap for soft-tissue cover, four months postoperatively. At a mean follow-up of 33 months (25 to 43), the mean flexion arc was 0° to 105°. All patients had full supination (85°) but none had any pronation. The mean MSTS score was 23.5 (23 to 24) and mean QuickDASH-9 score was 26.13 (16.5 to 35.75). Three patients had varus-valgus instability on examination, although only one had a sense of instability while working. Conclusion. Radial neck to humeral trochlea transposition offers a satisfactory and cost-effective biological reconstructive option after osteoarticular resection of the proximal ulna, in the short term. It provides good elbow function and, being a biological reconstruction option using native
Aims. A review of the literature on elbow replacement found no consistency in the clinical outcome measures which are used to assess the effectiveness of interventions. The aim of this study was to define core outcome domains for elbow replacement. Methods. A real-time Delphi survey was conducted over four weeks using outcomes from a scoping review of 362 studies on elbow replacement published between January 1990 and February 2021. A total of 583 outcome descriptors were rationalized to 139 unique outcomes. The survey consisted of 139 outcomes divided into 18 domains. The readability and clarity of the survey was determined by an advisory group including a patient representative. Participants were able to view aggregated responses from other participants in real time and to revisit their responses as many times as they wished during the study period. Participants were able to propose additional items for inclusion. A Patient and Public Inclusion and Engagement (PPIE) panel considered the consensus findings. Results. A total of 45 respondents completed the survey. Nine core mandatory domains were identified: ‘return to work or normal daily role’; delivery of care was measured in the domains ‘patient satisfaction with the outcome of surgery’ and ‘would the patient have the same operation again’; ‘pain’; ‘revision’; ‘elbow function’; ‘independence in activities of daily living’; ‘health-related quality of life’; and ‘adverse events’. ‘Elbow range of motion’ was identified as important by consensus but was felt to be less relevant by the PPIE panel. The PPIE panel unanimously stated that pain should be used as the primary outcome domain. Conclusion. This study defined core domains for the clinical outcomes of elbow replacement obtained by consensus from patients, carers, and healthcare professionals. Pain may be used as the primary outcome in future studies, where appropriate. Further work is required to define the instruments that should be used. Cite this article:
Aims. Reverse shoulder arthroplasty (RSA) has become the most common type of shoulder arthroplasty used in the UK, and a better understanding of the outcomes after revision of a failed RSA is needed. The aim of this study was to review the current evidence systematically to determine patient-reported outcome measures and the rates of re-revision and complications for patients undergoing revision of a RSA. Methods. MEDLINE, Embase, CENTRAL, and the Cochrane Database of Systematic Reviews were searched. Studies involving adult patients who underwent revision of a primary RSA for any indication were included. Those who underwent a RSA for failure of a total shoulder arthroplasty or hemiarthroplasty were excluded. Pre- and postoperative shoulder scores were evaluated in a random effects meta-analysis to determine the mean difference. The rates of re-revision and complications were also calculated. Results. The initial search elicited 3,166 results and, following removal of duplicates and screening, 13 studies with a total of 1,042 RSAs were identified. An increase in shoulder scores pre- to postoperatively was reported in all the studies. Following revision of a RSA to a further RSA, there was a significant increase in the American Shoulder and Elbow Surgeons Score (mean difference 20.78 (95% CI 8.16 to 33.40); p = 0.001). A re-revision rate at final follow-up ranging from 9% to 32%, a one-year re-revision rate of 14%, and a five-year re-revision rate of 23% were reported. The complication rate in all the studies was between 18.5% and 36%, with a total incidence of 29%. Conclusion. This is the largest systematic review of the outcomes following revision of a RSA. We found an improvement in functional outcomes after revision surgery, but the rates of re-revision and complications are high and warrant consideration when planning a revision procedure. Cite this article:
Periprosthetic joint infection represents a devastating complication after total elbow arthroplasty. Several measures can be implemented before, during, and after surgery to decrease infection rates, which exceed 5%. Debridement with antibiotics and implant retention has been reported to be successful in less than one-third of acute infections, but still plays a role. For elbows with well-fixed implants, staged retention seems to be equally successful as the more commonly performed two-stage reimplantation, both with a success rate of 70% to 80%. Permanent resection or even amputation are occasionally considered. Not uncommonly, a second-stage reimplantation requires complex reconstruction of the skeleton with allografts, and the extensor mechanism may also be deficient. Further developments are needed to improve our management of infection after elbow arthroplasty. Cite this article:
Aims. The survival of humeral hemiarthroplasties in patients with relatively intact glenoid cartilage could theoretically be extended by minimizing the associated postoperative glenoid erosion. Ceramic has gained attention as an alternative to metal as a material for hemiarthroplasties because of its superior tribological properties. The aim of this study was to assess the in vitro wear performance of ceramic and metal humeral hemiarthroplasties on natural glenoids. Methods. Intact right cadaveric shoulders from donors aged between 50 and 65 years were assigned to a ceramic group (n = 8, four male cadavers) and a metal group (n = 9, four male cadavers). A dedicated shoulder wear simulator was used to simulate daily activity by replicating the relevant joint motion and loading profiles. During testing, the joint was kept lubricated with diluted calf serum at room temperature. Each test of wear was performed for 500,000 cycles at 1.2 Hz. At intervals of 125,000 cycles, micro-CT scans of each glenoid were taken to characterize and quantify glenoid wear by calculating the change in the thickness of its articular cartilage. Results. At the completion of the wear test, the total thickness of the cartilage had significantly decreased in both the ceramic and metal groups, by 27% (p = 0.019) and 29% (p = 0.008), respectively. However, the differences between the two were not significant (p = 0.606) and the patterns of wear in the specimens were unpredictable. No significant correlation was found between cartilage wear and various factors, including age, sex, the size of the humeral head, joint mismatch, the thickness of the native cartilage, and the surface roughness (all p > 0.05). Conclusion. Although ceramic has better tribological properties than metal, we did not find evidence that its use in hemiarthroplasty of the shoulder in patients with healthy cartilage is a better alternative than conventional metal humeral heads. Cite this article:
Aims. The aim of this study was to review the provision of total elbow arthroplasties (TEAs) in England, including the incidence, the characteristics of the patients and the service providers, the types of implant, and the outcomes. Methods. We analyzed the primary TEAs recorded in the National Joint Registry (NJR) between April 2012 and December 2022, with mortality data from the Civil Registration of Deaths dataset. Linkage with Hospital Episode Statistics-Admitted Patient Care (HES-APC) data provided further information not collected by the NJR. The incidences were calculated using estimations of the populations from the Office for National Statistics. The annual number of TEAs performed by surgeons and hospitals was analyzed on a national and regional basis. Results. A total of 3,891 primary TEAs were included. The annual incidence of TEA was between 0.72 and 0.82 per 100,000 persons before 2020 and declined to 0.4 due to a decrease in elective TEAs during the COVID-19 pandemic, with a slight recovery in 2022. Older patients, those of white ethnicity and females, were more likely to undergo TEA. Those who underwent elective TEA had a median wait of between 89 (IQR 41 to 221) and 122 days (IQR 74 to 189) in the years before 2021, and this increased to 183 days (IQR 66 to 350) in 2021. The number of TEAs performed by surgeons per annum remained unchanged, with a median of two (IQR 1 to 3). The median annual number of TEAs per region was three to six times higher than the median annual case load of the highest volume hospital in a region. Patients in the lowest socioeconomic group had a higher rate of serious adverse events and mortality (11%) when undergoing TEA for acute trauma. Conclusion. In England, TEA is more common in older age groups, those of white ethnicity, and females. The COVID-19 pandemic affected the incidence of elective TEA and waiting times, and the provision of TEA has not yet recovered. The Getting it Right First Time recommendation of centralizing services to one centre per region could result in up to a six-fold increase in the number of TEAs being performed in some centres. Cite this article:
Aims. In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow. Methods. A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded. Results. The indications for removal of the implant were stiffness in five patients, aseptic loosening in five, and pain attributed to the RHA in three. The mean time interval between RHA for trauma to removal was ten months (7 to 21). Preoperatively, three patients had overlengthening of the implant, three had capitellar erosion, six had HO, and four had radiological evidence of loosening. At the final follow-up, the mean the flexion-extension arc improved significantly by 38.2° (95% CI 20 to 59; p = 0.002) and the mean arc of prono-supination improved significantly by 20° (95% CI 0 to 72.5; p = 0.035). The mean pain VAS score improved significantly by 3.5 (95% CI 2 to 5.5; p = 0.004). The mean MEPS improved significantly by 27.5 (95% CI 17.5 to 42.5; p = 0.002). The mean OES improved significantly by 9 (95% CI 2.5 to 14; p = 0.012), and the mean DASH score improved significantly by 23.5 (95% CI 7.5 to 31.6; p = 0.012). Ten patients (91%) had HO and osteoarthritis. Two patients underwent further surgery due to stiffness and pain, respectively. Conclusion. Simple removal of the implant at revision surgery following a failed RHA introduced following trauma provides satisfactory mid-term results with an acceptable risk of complications. Osteoarthritis, instability, and radioulnar impingement were not problems in this series. Cite this article:
Aims. The objective of this study was to compare simulated range of motion (ROM) for reverse total shoulder arthroplasty (rTSA) with and without adjustment for scapulothoracic orientation in a global reference system. We hypothesized that values for simulated ROM in preoperative planning software with and without adjustment for scapulothoracic orientation would be significantly different. Methods. A statistical shape model of the entire humerus and scapula was fitted into ten shoulder CT scans randomly selected from 162 patients who underwent rTSA. Six shoulder surgeons independently planned a rTSA in each model using prototype development software with the ability to adjust for scapulothoracic orientation, the starting position of the humerus, as well as kinematic planes in a global reference system simulating previously described posture types A, B, and C. ROM with and without posture adjustment was calculated and compared in all movement planes. Results. All movement planes showed significant differences when comparing protocols with and without adjustment for posture. The largest mean difference was seen in external rotation, being 62° (SD 16°) without adjustment compared to 25° (SD 9°) with posture adjustment (p < 0.001), with the highest mean difference being 49° (SD 15°) in type C. Mean extension was 57° (SD 18°) without adjustment versus 24° (SD 11°) with adjustment (p < 0.001) and the highest mean difference of 47° (SD 18°) in type C. Mean abducted internal rotation was 69° (SD 11°) without adjustment versus 31° (SD 6°) with posture adjustment (p < 0.001), showing the highest mean difference of 51° (SD 11°) in type C. Conclusion. The present study demonstrates that accounting for scapulothoracic orientation has a significant impact on simulated ROM for rTSA in all motion planes, specifically rendering vastly lower values for external rotation, extension, and high internal rotation. The substantial differences observed in this study warrant a critical re-evaluation of all previously published studies that examined component choice and placement for optimized ROM in rTSA using conventional preoperative planning software. Cite this article:
Aims. This study aims to describe a new method that may be used as a supplement to evaluate humeral rotational alignment during intramedullary nail (IMN) insertion using the profile of the perpendicular peak of the greater tuberosity and its relation to the transepicondylar axis. We called this angle the greater tuberosity version angle (GTVA). Methods. This study analyzed 506 cadaveric humeri of adult patients. All humeri were CT scanned using 0.625 × 0.625 × 0.625 mm cubic voxels. The images acquired were used to generate 3D surface models of the humerus. Next, 3D landmarks were automatically calculated on each 3D
Aims. Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and registry studies. To date, no large-scale study has investigated whether this is applicable to shoulder arthroplasty. We used the New Zealand Joint Registry to assess whether the use of surgical helmet systems was associated with lower all-cause revision or revision for deep infection in primary shoulder arthroplasties. Methods. We analyzed 16,000 shoulder arthroplasties (hemiarthroplasties, anatomical, and reverse geometry prostheses) recorded on the New Zealand Joint Registry from its inception in 2000 to the present day. We assessed patient factors including age, BMI, sex, and American Society of Anesthesiologists (ASA) grade, as well as whether or not the operation took place in a laminar flow operating theatre. Results. A total of 2,728 operations (17%) took place using surgical helmet systems. Patient cohorts were broadly similar in terms of indication for surgery (osteoarthritis, rheumatoid arthritis, fractures) and medical comorbidities (age and sex). There were 842 revisions (5% of cases) with just 98 for deep infection (0.6% of all cases or 11.6% of the revisions). There were no differences in all-cause revisions or revision for deep infection between the surgical helmet systems and conventional gowns (p = 0.893 and p = 0.911, respectively). Conclusion. We found no evidence that wearing a surgical helmet system reduces the incidence of periprosthetic joint infection in any kind of primary shoulder arthroplasty. We acknowledge the limitations of this registry study and accept that there may be other benefits in terms of personal protection, comfort, or visibility. However, given their financial and ecological footprint, they should be used judiciously in shoulder surgery. Cite this article:
Aims. Optimal glenoid positioning in reverse shoulder arthroplasty (RSA) is crucial to provide impingement-free range of motion (ROM). Lateralization and inclination correction are not yet systematically used. Using planning software, we simulated the most used glenoid implant positions. The primary goal was to determine the configuration that delivers the best theoretical impingement-free ROM. Methods. With the use of a 3D planning software (Blueprint) for RSA, 41 shoulders in 41 consecutive patients (17 males and 24 females; means age 73 years (SD 7)) undergoing RSA were planned. For the same anteroposterior positioning and retroversion of the glenoid implant, four different glenoid baseplate configurations were used on each shoulder to compare ROM: 1) no correction of the RSA angle and no lateralization (C-L-); 2) correction of the RSA angle with medialization by inferior reaming (C+M+); 3) correction of the RSA angle without lateralization by superior compensation (C+L-); and 4) correction of the RSA angle and additional lateralization (C+L+). The same humeral inlay implant and positioning were used on the humeral side for the four different glenoid configurations with a 3 mm symmetric 135° inclined polyethylene liner. Results. The configuration with lateralization and correction of the RSA angle (C+L+) led to better ROM in flexion, extension, adduction, and external rotation (p ≤ 0.001). Only internal rotation was not significantly different between groups (p = 0.388). The configuration where correction of the inclination was done by medialization (C+M+) led to the worst ROM in adduction, extension, abduction, flexion, and external rotation of the shoulder. Conclusion. Our software study shows that, when using a 135° inlay reversed humeral implant, correcting glenoid inclination (RSA angle 0°) and lateralizing the glenoid component by using an angled bony or metallic augment of 8 to 10 mm provides optimal impingement-free ROM. Cite this article:
Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four arthroplasty systems kept the stability ratio of standard liners constant (within 5%) across different sizes, while one system showed slight inconsistencies (within 10%), and ten arthroplasty systems showed large inconsistencies (range 11% to 28%). The stability ratio of constrained liners was consistent across different sizes in two arthroplasty systems and inconsistent in seven systems (range 18% to 106%). Conclusion. Large differences in jump height and resulting degree of constraint of rTSA liners were observed between different implant systems, and in many cases even within the same implant systems. While the immediate clinical effect remains unclear, in theory the degree of constraint of the liner plays an important role for the dislocation and notching risk of a rTSA system. Cite this article:
Aims. Extensive literature exists relating to the management of shoulder instability, with a more recent focus on glenoid and humeral bone loss. However, the optimal timing for surgery following a dislocation remains unclear. There is concern that recurrent dislocations may worsen subsequent surgical outcomes, with some advocating stabilization after the first dislocation. The aim of this study was to determine if the recurrence of instability following arthroscopic stabilization in patients without significant glenoid bone loss was influenced by the number of dislocations prior to surgery. Methods. A systematic review and meta-analysis was performed using the PubMed, EMBASE, Orthosearch, and Cochrane databases with the following search terms: ((shoulder or glenohumeral) and (dislocation or subluxation) and arthroscopic and (Bankart or stabilisation or stabilization) and (redislocation or re-dislocation or recurrence or instability)). Methodology followed the PRISMA guidelines. Data and outcomes were synthesized by two independent reviewers, and papers were assessed for bias and quality. Results. Overall, 35 studies including 7,995 shoulders were eligible for analysis, with a mean follow-up of 32.7 months (12 to 159.5). The rate of post-stabilization instability was 9.8% in first-time dislocators, 9.1% in recurrent dislocators, and 8.5% in a mixed cohort. A descriptive analysis investigated the influence of recurrent instability or age in the risk of instability post-stabilization, with an association seen with increasing age and a reduced risk of recurrence post-stabilization. Conclusion. Using modern arthroscopic techniques, patients sustaining an anterior shoulder dislocation without glenoid bone loss can expect a low risk of recurrence postoperatively, and no significant difference was found between first-time and recurrent dislocators. Furthermore, high-risk cohorts can expect a low, albeit slightly higher, rate of redislocation. With the findings of this study, patients and clinicians can be more informed as to the likely outcomes of arthroscopic stabilization within this patient subset. Cite this article:
Aims. The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA). Methods. Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged.
Aims. The prevalence of osteoarthritis (OA) associated with instability of the shoulder ranges between 4% and 60%. Articular cartilage is, however, routinely assessed in these patients using radiographs or scans (2D or 3D), with little opportunity to record early signs of cartilage damage. The aim of this study was to assess the prevalence and localization of chondral lesions and synovial damage in patients undergoing arthroscopic surgery for instablility of the shoulder, in order to classify them and to identify risk factors for the development of glenohumeral OA. Methods. A total of 140 shoulders in 140 patients with a mean age of 28.5 years (15 to 55), who underwent arthroscopic treatment for recurrent glenohumeral instability, were included. The prevalence and distribution of chondral lesions and synovial damage were analyzed and graded into stages according to the division of the humeral head and glenoid into quadrants. The following factors that might affect the prevalence and severity of chondral damage were recorded: sex, dominance, age, age at the time of the first dislocation, number of dislocations, time between the first dislocation and surgery, preoperative sporting activity, Beighton score, type of instability, and joint laxity. Results. A total of 133 patients (95%) had synovial or chondral lesions. At the time of surgery, shoulders were graded as having mild, moderate, and severe OA in 55 (39.2%), 72 (51.4%), and six (4.2%) patients, respectively. A Hill-Sachs lesion and fibrillation affecting the anteroinferior glenoid cartilage were the most common findings. There was a significant positive correlation between the the severity of the development of glenohumeral OA and the patient’s age, their age at the time of the first dislocation, and the number of dislocations (p = 0.004, p = 0.011, and p = 0.031, respectively). Conclusion. Synovial inflammation and chondral damage associated with instability of the shoulder are more prevalent than previously reported. The classification using quadrants gives surgeons more information about the chondral damage, and could explain the pattern of development of glenohumeral OA after stabilization of the shoulder. As the number of dislocations showed a positive correlation with the development of OA, this might be an argument for early stabilization. Cite this article: