The aim of this study was to perform a systematic review of the evidence for the use of intraoperative cell salvage in patients undergoing revision hip arthroplasty, and specifically to analyze the available data in order to quantify any associated reduction in the use of allogenic blood transfusion, and the volume which is used. An electronic search of MEDLINE (PubMed), Embase, Scopus, and the Cochrane Library was completed from the date of their inception to 24 February 2022, using a search strategy and protocol created in conjunction with the PRISMA statement. Inclusion criteria were patients aged > 18 years who underwent revision hip arthroplasty when cell salvage was used. Studies in which pre-donated red blood cells were used were excluded. A meta-analysis was also performed using a random effects model with significance set at p = 0.05.Aims
Methods
We hypothesised there was no clinical value in
using an autologous blood transfusion (ABT) drain in either primary total
hip (THR) or total knee replacement (TKR) in terms of limiting allogeneic
blood transfusions when a modern restrictive blood management regime
was followed. A total of 575 patients (65.2% men), with a mean age
of 68.9 years (36 to 94) were randomised in this three-arm study
to no drainage (group A), or to wound drainage with an ABT drain
for either six hours (group B) or 24 hours (group C). The primary
outcome was the number of patients receiving allogeneic blood transfusion.
Secondary outcomes were post-operative haemoglobin (Hb) levels,
length of hospital stay and adverse events. This study identified only 41 transfused patients, with no significant
difference in distribution between the three groups (p = 0.857).
The mean pre-operative haemoglobin (Hb) value in the transfused
group was 12.8 g/dL (9.8 to 15.5) Cite this article:
In this paper, we consider wound healing after
total knee arthroplasty.
Although mechanical stabilisation has been a hallmark of orthopaedic surgical management, orthobiologics are now playing an increasing role. Platelet-rich plasma (PRP) is a volume of plasma fraction of autologous blood having platelet concentrations above baseline. The platelet α granules are rich in growth factors that play an essential role in tissue healing, such as transforming growth factor-β, vascular endothelial growth factor, and platelet-derived growth factor. PRP is used in various surgical fields to enhance bone and soft-tissue healing by placing supraphysiological concentrations of autologous platelets at the site of tissue damage. The easily obtainable PRP and its possible beneficial outcome hold promise for new regenerative treatment approaches. The aim of this literature review was to describe the bioactivities of PRP, to elucidate the different techniques for PRP preparation, to review animal and human studies, to evaluate the evidence regarding the use of PRP in trauma and orthopaedic surgery, to clarify risks, and to provide guidance for future research.
We undertook a prospective randomised controlled trial to investigate the efficacy of autologous retransfusion drains in reducing the need for allogenic blood requirement after unilateral total knee replacement. We also monitored the incidence of post-operative complications. There were 86 patients in the control group, receiving standard care with a vacuum drain, and 92 who received an autologous drain and were retransfused postoperatively. Following serial haemoglobin measurements at 24, 48 and 72 hours, we found no difference in the need for allogenic blood between the two groups (control group 15.1%, retransfusion group 13% (p = 0.439)). The incidence of post-operative complications, such as wound infection, deep-vein thrombosis and chest infection, was also comparable between the groups. There were no adverse reactions associated with the retransfusion of autologous blood. Based on this study, the cost-effectiveness and continued use of autologous drains in total knee replacement should be questioned.
We undertook a prospective, randomised study in order to evaluate the efficacy of clamping the drains after intra-articular injection of saline with 1:500 000 adrenaline compared with post-operative blood salvage in reducing blood loss in 212 total knee arthroplasties. The mean post-operative drained blood volume after drain clamping was 352.1 ml compared to 662.3 ml after blood salvage (p <
0.0001). Allogenic blood transfusion was needed in one patient in the drain group and for three in the blood salvage group. Drain clamping with intra-articular injection of saline with adrenaline is more effective than post-operative autologous blood transfusion in reducing blood loss during total knee arthroplasty.
Using a computer-based quality assurance program, we analysed peri-operative data on 160 patients undergoing one-stage bilateral hip or knee arthroplasties under regional anaesthesia with routine anaesthetic monitoring and only using peripheral intravenous access for peri-operative safety. We monitored defined intra-operative adverse events such as hypotension, myocardial ischaemia, arrhythmias, hypovolaemia, hypertension and early post-operative complications. We also determined post-operative hip and knee function, and patient satisfaction with different aspects of the anaesthetic management. Those patients undergoing one-stage bilateral arthroplasties were matched according to a cross-stratification which used three variables (American Society of Anesthesiologists’ physical status scoring system, age and joint replaced) to patients undergoing unilateral hip or knee arthroplasties. Serious intra-operative adverse events were, with the exception of intra-operative hypotension, very infrequent in patients undergoing bilateral (nine adverse events) as well as unilateral arthroplasties (five adverse events). Early post-operative complications were also infrequent in both groups. However, the risks of receiving a heterologous blood transfusion (odds ratio 2.5; 95% confidence interval (CI) 1.3 to 5.0, estimated by exact conditional logistic regression) or vasoactive drugs (odds ratio 3.9; 95% CI 2.0 to 7.8) were significantly greater for patients undergoing bilateral operations. Patient satisfaction with anaesthesia was high; all patients who underwent the one-stage bilateral operation would choose the same anaesthetic technique again.
We prospectively audited 79 patients undergoing primary knee or hip arthroplasty (38 knees, 41 hips) and found that 66% (58% of knees, 73% of hips) had at least one unit of blood transfused postoperatively, with a mean transfusion requirement of 1.3 units per patient (1.1 for knees, 0 to 6; 1.5 for hips, 0 to 4). We then established a new protocol for postoperative blood transfusion. This requires the calculation of the maximum allowable blood loss (MABL) that each individual patient can safely lose based upon their weight and preoperative haematocrit. The total blood loss up to this volume is replaced with colloid. When a patient’s total blood loss reaches their MABL their haematocrit is measured at the bedside using the Microspin system (Bayer plc, Newbury, UK). If their haematocrit is low (<
0.30 for men, <
0.27 for women), blood is transfused. As a safety net all patients have their haemoglobin formally checked on days 1, 2, and 3 after surgery and have a transfusion if the haemoglobin levels are less than 8.5 g/dl. We conducted a further audit of 82 patients (35 knees, 47 hips) after the introduction of this protocol. Under the new protocol only 24% of patients required blood (11% of knees, 34% of hips) with a mean transfusion requirement of 0.56 units per patient (0.26 for knees, 0 to 4; 0.79 for hips, 0 to 4). The use of clinical audit and the introduction of strict guidelines for transfusion can change transfusion practice and result in improved patient care. Our transfusion protocol is a simple and effective method of keeping transfusion to a minimum and is particularly useful in departments which do not have the facility to use autologous blood or
We prospectively randomised 100 patients undergoing cemented total knee replacement to receive either a single deep closed-suction drain or no drain. The total blood loss was significantly greater in those with a drain (568 ml versus 119 ml, p <
0.01; 95% CI 360 to 520) although those without lost more blood into the dressings (55 ml versus 119 ml, p <
0.01; 95% CI −70 to 10). There was no statistical difference in the postoperative swelling or pain score, or in the incidence of pyrexia, ecchymosis, time at which flexion was regained or the need for manipulation, or in the incidence of infection at a minimum of five years after surgery in the two groups. We have been unable to provide evidence to support the use of a closed-suction drain in cemented knee arthroplasty. It merely interferes with mobilisation and complicates nursing.
We have carried out a randomised, controlled trial on 70 patients having unilateral total knee replacement in which transfusion was either with homologous bank blood or by