Aims

The aim of this study was to evaluate the healthcare costs and benefits of enoxaparin compared to aspirin in the prevention of symptomatic venous thromboembolism (VTE) after total hip arthroplasty (THA) or total knee arthroplasty (TKA) using data from the CRISTAL trial.

Methods

This trial-based economic analysis reports value for money as incremental cost per quality-adjusted life-year (QALY) gained in 2022 Australian dollars, compared to a single threshold value of AUD$70,000 per QALY. Event costs were estimated based on occurrence of VTEs and bleeds, and on published guidelines for treatment. Unit costs were taken from Australian sources. QALYs were estimated using CRISTAL six-month follow-up data. Sensitivity analyses are presented that vary the cost of VTE treatment, and extend the analyses to two years.


Bone & Joint Open
Vol. 2, Issue 11 | Pages 966 - 973
17 Nov 2021
Milligan DJ Hill JC Agus A Bryce L Gallagher N Beverland D

Aims

The aim of this study is to assess the impact of a pilot enhanced recovery after surgery (ERAS) programme on length of stay (LOS) and post-discharge resource usage via service evaluation and cost analysis.

Methods

Between May and December 2019, 100 patients requiring hip or knee arthroplasty were enrolled with the intention that each would have a preadmission discharge plan, a preoperative education class with nominated helper, a day of surgery admission and mobilization, a day one discharge, and access to a 24/7 dedicated helpline. Each was matched with a patient under the pre-existing pathway from the previous year.


Bone & Joint Open
Vol. 1, Issue 12 | Pages 743 - 748
1 Dec 2020
Mahon J McCarthy CJ Sheridan GA Cashman JP O'Byrne JM Kenny P

Aims

The Exeter V40 cemented femoral stem was first introduced in 2000. The largest single-centre analysis of this implant to date was published in 2018 by Westerman et al. Excellent results were reported at a minimum of ten years for the first 540 cases performed at the designer centre in the Exeter NHS Trust, with stem survivorship of 96.8%. The aim of this current study is to report long-term outcomes and survivorship for the Exeter V40 stem in a non-designer centre.

Methods

All patients undergoing primary total hip arthroplasty using the Exeter V40 femoral stem between 1 January 2005 and 31 January 2010 were eligible for inclusion. Data were collected prospectively, with routine follow-up at six to 12 months, two years, five years, and ten years. Functional outcomes were assessed using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. Outcome measures included data on all components in situ beyond ten years, death occurring within ten years with components in situ, and all-cause revision surgery.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 349 - 358
1 Mar 2016
Akiyama K Nakata K Kitada M Yamamura M Ohori T Owaki H Fuji T

Aims. We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA). . Patients and Methods. We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively. . Results. The mean internal rotation increased by 11° (-15° to 46°) and was associated with underlying disease (OA), pre-operative range of internal rotation, gender, surgical approach, leg lengthening, and change of femoral anteversion (adjusted R. 2. : 0.253, p < 0.001). The mean lateral patellar tilt increased by 4° (-5° to 14°) and was associated with age, leg lengthening, and increment of hip internal rotation (adjusted R. 2. : 0.193, p < 0.001). Conclusion. Both internal rotation of the hip at rest and lateral patellar tilt are increased after THA. Changes in rotation after THA may affect gait, daily activities, the rate of dislocation of the hip, and ipsilateral knee pain. Take home message: Internal rotation of the hip at rest and lateral patellar tilt increase after THA. Cite this article: Bone Joint J 2016;98-B:349–58


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1076 - 1081
1 Aug 2015
Patel A Pavlou G Mújica-Mota RE Toms AD

Total knee arthroplasty (TKA) and total hip arthroplasty (THA) are recognised and proven interventions for patients with advanced arthritis. Studies to date have demonstrated a steady increase in the requirement for primary and revision procedures. Projected estimates made for the United States show that by 2030 the demand for primary TKA will grow by 673% and for revision TKA by 601% from the level in 2005. For THA the projected estimates are 174% and 137% for primary and revision surgery, respectively. The purpose of this study was to see if those predictions were similar for England and Wales using data from the National Joint Registry and the Office of National Statistics.

Analysis of data for England and Wales suggest that by 2030, the volume of primary and revision TKAs will have increased by 117% and 332%, respectively between 2012 and 2030. The data for the United States translates to a 306% cumulative rate of increase between 2012 and 2030 for revision surgery, which is similar to our predictions for England and Wales.

The predictions from the United States for primary TKA were similar to our upper limit projections. For THA, we predicted an increase of 134% and 31% for primary and revision hip surgery, respectively.

Our model has limitations, however, it highlights the economic burden of arthroplasty in the future in England and Wales as a real and unaddressed problem. This will have significant implications for the provision of health care and the management of orthopaedic services in the future.

Cite this article: Bone Joint J 2015;97-B:1076–1081.


Bone & Joint Research
Vol. 3, Issue 4 | Pages 95 - 100
1 Apr 2014
Kaneyama R Otsuka M Shiratsuchi H Oinuma K Miura Y Tamaki T

Objectives

Because posterior cruciate ligament (PCL) resection makes flexion gaps wider in total knee replacement (TKR), preserving or sacrificing a PCL affects the gap equivalence; however, there are no criteria for the PCL resection that consider gap situations of each knee. This study aims to investigate gap characteristics of knees and to consider the criteria for PCL resection.

Methods

The extension and flexion gaps were measured, first with the PCL preserved and subsequently with the PCL removed (in cases in which posterior substitute components were selected). The PCL preservation or sacrifice was solely determined by the gap measurement results, without considering other functions of the PCL such as ‘roll back.’


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1429 - 1434
1 Oct 2010
Mehin R Burnett RS Brasher PMA

A new generation of knee prostheses has been introduced with the intention of improving post-operative knee flexion. In order to evaluate whether this goal has been achieved we performed a systematic review and meta-analysis. Systematic literature searches were conducted on MEDLINE and EMBASE from their inception to December 2007, and proceedings of scientific meetings were also searched. Only randomised, clinical trials were included in the meta-analysis. The mean difference in the maximum post-operative flexion between the ‘high-flex’ and conventional types of prosthesis was defined as the primary outcome measure. A total of five relevant articles was identified.

Analysis of these trials suggested that no clinically relevant or statistically significant improvement was obtained in flexion with the ‘high-flex’ prostheses. The weighted mean difference was 2.1° (95% confidence interval −0.2 to +4.3; p = 0.07).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 136 - 141
1 Jan 2010
Franken M Grimm B Heyligers I

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value.

Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p < 0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1623 - 1626
1 Dec 2008
Kulkarni A Partington P Kelly D Muller S

Digital radiography is becoming widespread. Accurate pre-operative templating of digital images of the hip traditionally involves positioning a calibration object at its centre. This can be difficult and cause embarrassment. We have devised a method whereby a planar disc placed on the radiographic cassette accounts for the expected magnification. Initial examination of 50 pelvic CT scans showed a mean hip centre distance of 117 mm (79 to 142) above the gluteal skin. Further calculations predicted that a disc of 37.17 mm diameter, placed on the cassette, would appear identical to a 30 mm sphere placed at the level of the centre of the hip as requested by our templating software. We assessed accuracy and reproducibility by ‘reverse calibration’ of 20 radiographs taken three months after hip replacement using simultaneous sphere and disc methods, and a further 20 with a precision disc of accurate size. Even when variations in patient size were ignored, the disc proved more accurate and reliable than the sphere.

The technique is reliable, robust, cost effective and acceptable to patients and radiographers. It can easily be used in any radiography department after a few simple calculations and manufacture of appropriately-sized discs.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 82 - 84
1 Jan 1996
Izquierdo-Avino RJ Siney PD Wroblewski BM

We studied wear in the ultra-high-molecular-weight polyethylene offset bore socket in 54 hips which had had Charnley low-friction arthroplasty. At an average follow-up of 8.1 years, the mean penetration rate was 0.04 mm per year. Correlation between the depth of socket penetration and the incidence of socket migration was confirmed, but socket migration occurred with lower penetration than had been previously reported