Advertisement for orthosearch.org.uk
Results 1 - 50 of 1543
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1342 - 1346
1 Oct 2016
Spencer-Gardner L Pierrepont J Topham M Baré J McMahon S Shimmin AJ

Aims. Accurate placement of the acetabular component during total hip arthroplasty (THA) is an important factor in the success of the procedure. However, the reported accuracy varies greatly and is dependent upon whether free hand or navigated techniques are used. The aim of this study was to assess the accuracy of an instrument system that incorporates 3D printed, patient-specific guides designed to optimise the placement of the acetabular component. Patients and Methods. A total of 100 consecutive patients were prospectively enrolled and the accuracy of placement of the acetabular component was measured using post-operative CT scans. Results. The mean absolute deviation from the planned inclination and anteversion was 3.9° (0.0° to 13.6°) and 3.6° (0.0° to 12.9°), respectively. In 91% of cases the planned target of +/-10° was achieved for both inclination and anteversion. Conclusion. Accurate placement of the acetabular component can be achieved using patient-specific guides and is superior to free hand techniques and comparable to navigated and robotic techniques. Cite this article: Bone Joint J 2016;98-B:1342–6


Bone & Joint Research
Vol. 1, Issue 8 | Pages 180 - 191
1 Aug 2012
Stilling M Kold S de Raedt S Andersen NT Rahbek O Søballe K

Objectives. The accuracy and precision of two new methods of model-based radiostereometric analysis (RSA) were hypothesised to be superior to a plain radiograph method in the assessment of polyethylene (PE) wear. Methods. A phantom device was constructed to simulate three-dimensional (3D) PE wear. Images were obtained consecutively for each simulated wear position for each modality. Three commercially available packages were evaluated: model-based RSA using laser-scanned cup models (MB-RSA), model-based RSA using computer-generated elementary geometrical shape models (EGS-RSA), and PolyWare. Precision (95% repeatability limits) and accuracy (Root Mean Square Errors) for two-dimensional (2D) and 3D wear measurements were assessed. Results. The precision for 2D wear measures was 0.078 mm, 0.102 mm, and 0.076 mm for EGS-RSA, MB-RSA, and PolyWare, respectively. For the 3D wear measures the precision was 0.185 mm, 0.189 mm, and 0.244 mm for EGS-RSA, MB-RSA, and PolyWare respectively. Repeatability was similar for all methods within the same dimension, when compared between 2D and 3D (all p > 0.28). For the 2D RSA methods, accuracy was below 0.055 mm and at least 0.335 mm for PolyWare. For 3D measurements, accuracy was 0.1 mm, 0.2 mm, and 0.3 mm for EGS-RSA, MB-RSA and PolyWare respectively. PolyWare was less accurate compared with RSA methods (p = 0.036). No difference was observed between the RSA methods (p = 0.10). Conclusions. For all methods, precision and accuracy were better in 2D, with RSA methods being superior in accuracy. Although less accurate and precise, 3D RSA defines the clinically relevant wear pattern (multidirectional). PolyWare is a good and low-cost alternative to RSA, despite being less accurate and requiring a larger sample size


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1077 - 1085
1 Aug 2012
Yin Z Zhang J Kan S Wang X

Follow-up radiographs are usually used as the reference standard for the diagnosis of suspected scaphoid fractures. However, these are prone to errors in interpretation. We performed a meta-analysis of 30 clinical studies on the diagnosis of suspected scaphoid fractures, in which agreement data between any of follow-up radiographs, bone scintigraphy, magnetic resonance (MR) imaging, or CT could be obtained, and combined this with latent class analysis to infer the accuracy of these tests on the diagnosis of suspected scaphoid fractures in the absence of an established standard. The estimated sensitivity and specificity were respectively 91.1% and 99.8% for follow-up radiographs, 97.8% and 93.5% for bone scintigraphy, 97.7% and 99.8% for MRI, and 85.2% and 99.5% for CT. The results were generally robust in multiple sensitivity analyses. There was large between-study heterogeneity for the sensitivity of follow-up radiographs and CT, and imprecision about their sensitivity estimates. If we acknowledge the lack of a reference standard for diagnosing suspected scaphoid fractures, MRI is the most accurate test; follow-up radiographs and CT may be less sensitive, and bone scintigraphy less specific


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1461 - 1468
1 Dec 2024
Hamoodi Z Shapiro J Sayers A Whitehouse MR Watts AC

Aims. The aim of this audit was to assess and improve the completeness and accuracy of the National Joint Registry (NJR) dataset for arthroplasty of the elbow. Methods. It was performed in two phases. In Phase 1, the completeness was assessed by comparing the NJR elbow dataset with the NHS England Hospital Episode Statistics (HES) data between April 2012 and April 2020. In order to assess the accuracy of the data, the components of each arthroplasty recorded in the NJR were compared to the type of arthroplasty which was recorded. In Phase 2, a national collaborative audit was undertaken to evaluate the reasons for unmatched data, add missing arthroplasties, and evaluate the reasons for the recording of inaccurate arthroplasties and correct them. Results. Phase 1 identified 5,539 arthroplasties in HES which did not match an arthroplasty on the NJR, and 448 inaccurate arthroplasties from 254 hospitals. Most mismatched procedures (3,960 procedures; 71%) were radial head arthroplasties (RHAs). In Phase 2, 142 NHS hospitals with 3,640 (66%) mismatched and 314 (69%) inaccurate arthroplasties volunteered to assess their records. A large proportion of the unmatched data (3,000 arthroplasties; 82%) were confirmed as being missing from the NJR. The overall rate of completeness of the NJR elbow dataset improved from 63% to 83% following phase 2, and the completeness of total elbow arthroplasty data improved to 93%. Missing RHAs had the biggest impact on the overall completeness, but through the audit the number of RHAs in the NJR nearly doubled and completeness increased from 35% to 70%. The accuracy of data was 94% and improved to 98% after correcting 212 of the 448 inaccurately recorded arthroplasties. Conclusion. The rate of completeness of the NJR total elbow arthroplasty dataset is currently 93% and the accuracy is 98%. This audit identified challenges of data capture with regard to RHAs. Collaboration with a trauma and orthopaedic trainees through the British Orthopaedic Trainee Association improved the completeness and accuracy of the NJR elbow dataset, which will improve the validity of the reports and of the associated research. Cite this article: Bone Joint J 2024;106-B(12):1461–1468


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 104 - 109
1 Mar 2024
Sugano N Maeda Y Fuji H Tamura K Nakamura N Takashima K Uemura K Hamada H

Aims. Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods. We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results. The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion. The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component. Cite this article: Bone Joint J 2024;106-B(3 Supple A):104–109


Bone & Joint Open
Vol. 5, Issue 4 | Pages 260 - 268
1 Apr 2024
Broekhuis D Meurs WMH Kaptein BL Karunaratne S Carey Smith RL Sommerville S Boyle R Nelissen RGHH

Aims. Custom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions. Methods. A multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed. Results. CTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance. Conclusion. This study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival. Cite this article: Bone Jt Open 2024;5(4):260–268


Bone & Joint Open
Vol. 3, Issue 6 | Pages 475 - 484
13 Jun 2022
Jang SJ Vigdorchik JM Windsor EW Schwarzkopf R Mayman DJ Sculco PK

Aims. Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. Methods. A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (. Δ. sacral slope(SS). stand-sit. > 30°), or stiff (. ∆. SS. stand-sit. < 10°) spinopelvic mobility contributed to increased error rates. Results. The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. Conclusion. Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475–484


Aims. This study aimed to analyze the accuracy and errors associated with 3D-printed, patient-specific resection guides (3DP-PSRGs) used for bone tumour resection. Methods. We retrospectively reviewed 29 bone tumour resections that used 3DP-PSRGs based on 3D CT and 3D MRI. We evaluated the resection amount errors and resection margin errors relative to the preoperative plans. Guide-fitting errors and guide distortion were evaluated intraoperatively and one month postoperatively, respectively. We categorized each of these error types into three grades (grade 1, < 1 mm; grade 2, 1 to 3 mm; and grade 3, > 3 mm) to evaluate the overall accuracy. Results. The maximum resection amount error was 2 mm. Out of 29 resection amount errors, 15 (51.7%) were grade 1 errors and 14 (48.3%) were grade 2 errors. Complex resections were associated with higher-grade resection amount errors (p < 0.001). The actual resection margins correlated significantly with the planned margins; however, there were some discrepancies. The maximum guide-fitting error was 3 mm. There were 22 (75.9%), five (17.2%), and two (6.9%) grade 1, 2, and 3 guide-fitting errors, respectively. There was no significant association between complex resection and fitting error grades. The guide distortion after one month in all patients was rated as grade 1. Conclusion. In terms of the accurate resection amount according to the preoperative planning, 3DP-PSRGs can be a viable option for bone tumour resection. However, 3DP-PSRG use may be associated with resection margin length discrepancies relative to the planned margins. Such discrepancies should be considered when determining surgical margins. Therefore, a thorough evaluation of the preoperative imaging and surgical planning is still required, even if 3DP-PSRGs are to be used. Cite this article: Bone Joint J 2023;105-B(2):190–197


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 74 - 80
1 Jun 2021
Deckey DG Rosenow CS Verhey JT Brinkman JC Mayfield CK Clarke HD Bingham JS

Aims. Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. Methods. A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed. Results. In all, 103 M-TKAs and 96 RA-TKAs were included. In RA-TKA versus M-TKA, respectively: mean femoral positioning (0.9° (SD 1.2°) vs 1.7° (SD 1.1°)), mean tibial positioning (0.3° (SD 0.9°) vs 1.3° (SD 1.0°)), mean posterior tibial slope (-0.3° (SD 1.3°) vs 1.7° (SD 1.1°)), and mean mechanical axis limb alignment (1.0° (SD 1.7°) vs 2.7° (SD 1.9°)) all deviated significantly less from the plan (all p < 0.001); significantly fewer knees required a distal femoral recut (10 (10%) vs 22 (22%), p = 0.033); and deviation from planned polyethylene thickness was significantly less (1.4 mm (SD 1.6) vs 2.7 mm (SD 2.2), p < 0.001). Conclusion. RA-TKA is significantly more accurate and precise in planning both component positioning and final polyethylene insert thickness. Future studies should investigate whether this increased accuracy and precision has an impact on clinical outcomes. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed and can be further individualized to the patient. Cite this article: Bone Joint J 2021;103-B(6 Supple A):74–80


Bone & Joint Research
Vol. 9, Issue 10 | Pages 653 - 666
7 Oct 2020
Li W Li G Chen W Cong L

Aims. The aim of this study was to systematically compare the safety and accuracy of robot-assisted (RA) technique with conventional freehand with/without fluoroscopy-assisted (CT) pedicle screw insertion for spine disease. Methods. A systematic search was performed on PubMed, EMBASE, the Cochrane Library, MEDLINE, China National Knowledge Infrastructure (CNKI), and WANFANG for randomized controlled trials (RCTs) that investigated the safety and accuracy of RA compared with conventional freehand with/without fluoroscopy-assisted pedicle screw insertion for spine disease from 2012 to 2019. This meta-analysis used Mantel-Haenszel or inverse variance method with mixed-effects model for heterogeneity, calculating the odds ratio (OR), mean difference (MD), standardized mean difference (SMD), and 95% confidence intervals (CIs). The results of heterogeneity, subgroup analysis, and risk of bias were analyzed. Results. Ten RCTs with 713 patients and 3,331 pedicle screws were included. Compared with CT, the accuracy rate of RA was superior in Grade A with statistical significance and Grade A + B without statistical significance. Compared with CT, the operating time of RA was longer. The difference between RA and CT was statistically significant in radiation dose. Proximal facet joint violation occurred less in RA than in CT. The postoperative Oswestry Disability Index (ODI) of RA was smaller than that of CT, and there were some interesting outcomes in our subgroup analysis. Conclusion. RA technique could be viewed as an accurate and safe pedicle screw implantation method compared to CT. A robotic system equipped with optical intraoperative navigation is superior to CT in accuracy. RA pedicle screw insertion can improve accuracy and maintain stability for some challenging areas. Cite this article: Bone Joint Res 2020;9(10):653–666


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 696 - 701
1 Jun 2023
Kurisunkal V Morris G Kaneuchi Y Bleibleh S James S Botchu R Jeys L Parry MC

Aims. Intra-articular (IA) tumours around the knee are treated with extra-articular (EA) resection, which is associated with poor functional outcomes. We aim to evaluate the accuracy of MRI in predicting IA involvement around the knee. Methods. We identified 63 cases of high-grade sarcomas in or around the distal femur that underwent an EA resection from a prospectively maintained database (January 1996 to April 2020). Suspicion of IA disease was noted in 52 cases, six had IA pathological fracture, two had an effusion, two had prior surgical intervention (curettage/IA intervention), and one had an osseous metastasis in the proximal tibia. To ascertain validity, two musculoskeletal radiologists (R1, R2) reviewed the preoperative imaging (MRI) of 63 consecutive cases on two occasions six weeks apart. The radiological criteria for IA disease comprised evidence of tumour extension within the suprapatellar pouch, intercondylar notch, extension along medial/lateral retinaculum, and presence of IA fracture. The radiological predictions were then confirmed with the final histopathology of the resected specimens. Results. The resection histology revealed 23 cases (36.5%) showing IA disease involvement compared with 40 cases without (62%). The intraobserver variability of R1 was 0.85 (p < 0.001) compared to R2 with κ = 0.21 (p = 0.007). The interobserver variability was κ = 0.264 (p = 0.003). Knee effusion was found to be the most sensitive indicator of IA involvement, with a sensitivity of 91.3% but specificity of only 35%. However, when combined with a pathological fracture, this rose to 97.5% and 100% when disease was visible in Hoffa’s fat pad. Conclusion. MRI imaging can sometimes overestimate IA joint involvement and needs to be correlated with clinical signs. In the light of our findings, we would recommend EA resections when imaging shows effusion combined with either disease in Hoffa’s fat pad or retinaculum, or pathological fractures. Cite this article: Bone Joint J 2023;105-B(6):696–701


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims. Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane. Methods. Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation. Results. Overall, 26/40 hips had a centre of rotation displaced posteriorly compared to the contralateral hip, increasing to 33/40 once corrected for sagittal tilt, with a mean posterior displacement of 7 mm. Linear regression analysis indicated that stem anteversion needed to be increased by 10.8° to recreate the head centre in the AP plane. Merely matching the native version would result in a 12 mm posterior displacement. Conclusion. This study demonstrates the significant incidence of posterior displacement of the head centre in uncemented hip arthroplasty. Effects of such displacement include a reduction in impingement free range of motion, potential alterations in muscle force vectors and lever arms, and impaired proprioception due to muscle fibre reorientation. Cite this article: Bone Joint Res 2022;11(3):180–188


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 371 - 375
1 Mar 2020
Cawley D Dhokia R Sales J Darwish N Molloy S

With the identification of literature shortfalls on the techniques employed in intraoperative navigated (ION) spinal surgery, we outline a number of measures which have been synthesised into a coherent operative technique. These include positioning, dissection, management of the reference frame, the grip, the angle of attack, the drill, the template, the pedicle screw, the wire, and navigated intrathecal analgesia. Optimizing techniques to improve accuracy allow an overall reduction of the repetition of the surgical steps with its associated productivity benefits including time, cost, radiation, and safety. Cite this article: Bone Joint J 2020;102-B(3):371–375


Bone & Joint Open
Vol. 3, Issue 5 | Pages 367 - 374
5 May 2022
Sinagra ZP Davis JS Lorimer M de Steiger RN Graves SE Yates P Manning L

Aims. National joint registries under-report revisions for periprosthetic joint infection (PJI). We aimed to validate PJI reporting to the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) and the factors associated with its accuracy. We then applied these data to refine estimates of the total national burden of PJI. Methods. A total of 561 Australian cases of confirmed PJI were captured by a large, prospective observational study, and matched to data available for the same patients through the AOANJRR. Results. In all, 501 (89.3%) cases of PJI recruited to the prospective observational study were successfully matched with the AOANJRR database. Of these, 376 (75.0%) were captured by the registry, while 125 (25.0%) did not have a revision or reoperation for PJI recorded. In a multivariate logistic regression analysis, early (within 30 days of implantation) PJIs were less likely to be reported (adjusted odds ratio (OR) 0.56; 95% confidence interval (CI) 0.34 to 0.93; p = 0.020), while two-stage revision procedures were more likely to be reported as a PJI to the registry (OR 5.3 (95% CI 2.37 to 14.0); p ≤ 0.001) than debridement and implant retention or other surgical procedures. Based on this data, the true estimate of the incidence of PJI in Australia is up to 3,900 cases per year. Conclusion. In Australia, infection was not recorded as the indication for revision or reoperation in one-quarter of those with confirmed PJI. This is better than in other registries, but suggests that registry-captured estimates of the total national burden of PJI are underestimated by at least one-third. Inconsistent PJI reporting is multifactorial but could be improved by developing a nested PJI registry embedded within the national arthroplasty registry. Cite this article: Bone Jt Open 2022;3(5):367–373


The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 166 - 172
1 Feb 2016
Langlois J Hamadouche M

Previous standards for assessing the reliability of a measurement tool have lacked consistency. We reviewed the most current American Society for Testing and Materials and International Organisation for Standardisation (ISO) recommendations, and propose an algorithm for orthopaedic surgeons. When assessing a measurement tool, conditions of the experimental set-up and clear formulae used to compile the results should be strictly reported. According to these recent guidelines, accuracy is a confusing word with an overly broad meaning and should therefore be abandoned. Depending on the experimental conditions, one should be referring to bias (when the study protocol involves accepted reference values), and repeatability (sr, r) or reproducibility (SR, R). In the absence of accepted reference values, only repeatability (sr, r) or reproducibility (SR, R) should be provided. Take home message: Assessing the reliability of a measurement tool involves reporting bias, repeatability and/or reproducibility depending on the defined conditions, instead of precision or accuracy. Cite this article: Bone Joint J 2016;98-B2:166–72


Bone & Joint Research
Vol. 5, Issue 7 | Pages 307 - 313
1 Jul 2016
Sandgren B Skorpil M Nowik P Olivecrona H Crafoord J Weidenhielm L Persson A

Objectives. Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. Materials and Methods. A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV. Results. We could assess wear and PAO while substantially lowering the effective radiation dose to 0.7 mSv for a total pelvic view with an accuracy of around 0.5 mm for linear wear and 2 mm to 3 mm for PAO. Conclusion. CT for detection of prosthetic wear and PAO could be used with clinically acceptable accuracy at a radiation exposure level equal to plain radiographic exposures. Cite this article: B. Sandgren, M. Skorpil, P. Nowik, H. Olivecrona, J. Crafoord, L. Weidenhielm, A. Persson. Assessment of wear and periacetabular osteolysis using dual energy computed tomography on a pig cadaver to identify the lowest acceptable radiation dose. Bone Joint Res 2016;5:307–313. DOI: 10.1302/2046-3758.57.2000566


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1119 - 1126
1 Jun 2021
Ivy MI Sharma K Greenwood-Quaintance KE Tande AJ Osmon DR Berbari EF Mandrekar J Beauchamp CP Hanssen AD Abdel MP Lewallen DG Perry K Block DR Snyder MR Patel R

Aims. The aim of this study was to determine the diagnostic accuracy of α defensin (AD) lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) tests for periprosthetic joint infection (PJI) in comparison to conventional synovial white blood cell (WBC) count and polymorphonuclear neutrophil percentage (PMN%) analysis. Methods. Patients undergoing joint aspiration for evaluation of pain after total knee arthroplasty (TKA) or total hip arthroplasty (THA) were considered for inclusion. Synovial fluids from 99 patients (25 THA and 74 TKA) were analyzed by WBC count and PMN% analysis, AD LFA, and AD ELISA. WBC and PMN% cutoffs of ≥ 1,700 cells/mm. 3. and ≥ 65% for TKA and ≥ 3,000 cells/mm. 3. and ≥ 80% for THA were used, respectively. A panel of three physicians, all with expertise in orthopaedic infections and who were blinded to the results of AD tests, independently reviewed patient data to diagnose subjects as with or without PJI. Consensus PJI classification was used as the reference standard to evaluate test performances. Results were compared using McNemar’s test and area under the receiver operating characteristic curve (AUC) analysis. Results. Expert consensus classified 18 arthroplasies as having failed due to PJI and 81 due to aseptic failure. Using these classifications, the calculated sensitivity and specificity of AD LFA was 83.3% (95% confidence interval (CI) 58.6 to 96.4) and 93.8% (95% CI 86.2 to 98.0), respectively. Sensitivity and specificity of AD ELISA was 83.3% (95% CI 58.6 to 96.4) and 96.3% (95% CI 89.6 to 99.2), respectively. There was no statistically significant difference between sensitivity (p = 1.000) or specificity (p = 0.157) of the two AD assays. AUC for AD LFA was 0.891. In comparison, AUC for synovial WBC count, PMN%, and the combination of the two values was 0.821 (sensitivity p = 1.000, specificity p < 0.001), 0.886 (sensitivity p = 0.317, specificity p = 0.011), and 0.926 (sensitivity p = 0.317, specificity p = 0.317), respectively. Conclusion. The diagnostic accuracy of synovial AD for PJI diagnosis is comparable and not statistically superior to that of synovial WBC count plus PMN% combined. Cite this article: Bone Joint J 2021;103-B(6):1119–1126


Bone & Joint Research
Vol. 6, Issue 10 | Pages 577 - 583
1 Oct 2017
Sallent A Vicente M Reverté MM Lopez A Rodríguez-Baeza A Pérez-Domínguez M Velez R

Objectives. To assess the accuracy of patient-specific instruments (PSIs) versus standard manual technique and the precision of computer-assisted planning and PSI-guided osteotomies in pelvic tumour resection. Methods. CT scans were obtained from five female cadaveric pelvises. Five osteotomies were designed using Mimics software: sacroiliac, biplanar supra-acetabular, two parallel iliopubic and ischial. For cases of the left hemipelvis, PSIs were designed to guide standard oscillating saw osteotomies and later manufactured using 3D printing. Osteotomies were performed using the standard manual technique in cases of the right hemipelvis. Post-resection CT scans were quantitatively analysed. Student’s t-test and Mann–Whitney U test were used. Results. Compared with the manual technique, PSI-guided osteotomies improved accuracy by a mean 9.6 mm (p < 0.008) in the sacroiliac osteotomies, 6.2 mm (p < 0.008) and 5.8 mm (p < 0.032) in the biplanar supra-acetabular, 3 mm (p < 0.016) in the ischial and 2.2 mm (p < 0.032) and 2.6 mm (p < 0.008) in the parallel iliopubic osteotomies, with a mean linear deviation of 4.9 mm (p < 0.001) for all osteotomies. Of the manual osteotomies, 53% (n = 16) had a linear deviation > 5 mm and 27% (n = 8) were > 10 mm. In the PSI cases, deviations were 10% (n = 3) and 0 % (n = 0), respectively. For angular deviation from pre-operative plans, we observed a mean improvement of 7.06° (p < 0.001) in pitch and 2.94° (p < 0.001) in roll, comparing PSI and the standard manual technique. Conclusion. In an experimental study, computer-assisted planning and PSIs improved accuracy in pelvic tumour resections, bringing osteotomy results closer to the parameters set in pre-operative planning, as compared with standard manual techniques. Cite this article: A. Sallent, M. Vicente, M. M. Reverté, A. Lopez, A. Rodríguez-Baeza, M. Pérez-Domínguez, R. Velez. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Joint Res 2017;6:577–583. DOI: 10.1302/2046-3758.610.BJR-2017-0094.R1


Bone & Joint Research
Vol. 9, Issue 7 | Pages 440 - 449
1 Jul 2020
Huang Z Li W Lee G Fang X Xing L Yang B Lin J Zhang W

Aims. The aim of this study was to evaluate the performance of metagenomic next-generation sequencing (mNGS) in detecting pathogens from synovial fluid of prosthetic joint infection (PJI) patients. Methods. A group of 75 patients who underwent revision knee or hip arthroplasties were enrolled prospectively. Ten patients with primary arthroplasties were included as negative controls. Synovial fluid was collected for mNGS analysis. Optimal thresholds were determined to distinguish pathogens from background microbes. Synovial fluid, tissue, and sonicate fluid were obtained for culture. Results. A total of 49 PJI and 21 noninfection patients were finally included. Of the 39 culture-positive PJI cases, mNGS results were positive in 37 patients (94.9%), and were consistent with culture results at the genus level in 32 patients (86.5%) and at the species level in 27 patients (73.0%). Metagenomic next-generation sequencing additionally identified 15 pathogens from five culture-positive and all ten culture-negative PJI cases, and even one pathogen from one noninfection patient, while yielding no positive findings in any primary arthroplasty. However, seven pathogens identified by culture were missed by mNGS. The sensitivity of mNGS for diagnosing PJI was 95.9%, which was significantly higher than that of comprehensive culture (79.6%; p = 0.014). The specificity is similar between mNGS and comprehensive culture (95.2% and 95.2%, respectively; p = 1.0). Conclusion. Metagenomic next-generation sequencing can effectively identify pathogens from synovial fluid of PJI patients, and demonstrates high accuracy in diagnosing PJI. Cite this article: Bone Joint Res 2020;9(7):440–449


Bone & Joint Research
Vol. 10, Issue 8 | Pages 536 - 547
2 Aug 2021
Sigmund IK McNally MA Luger M Böhler C Windhager R Sulzbacher I

Aims. Histology is an established tool in diagnosing periprosthetic joint infections (PJIs). Different thresholds, using various infection definitions and histopathological criteria, have been described. This study determined the performance of different thresholds of polymorphonuclear neutrophils (≥ 5 PMN/HPF, ≥ 10 PMN/HPF, ≥ 23 PMN/10 HPF) , when using the European Bone and Joint Infection Society (EBJIS), Infectious Diseases Society of America (IDSA), and the International Consensus Meeting (ICM) 2018 criteria for PJI. Methods. A total of 119 patients undergoing revision total hip (rTHA) or knee arthroplasty (rTKA) were included. Permanent histology sections of periprosthetic tissue were evaluated under high power (400× magnification) and neutrophils were counted per HPF. The mean neutrophil count in ten HPFs was calculated (PMN/HPF). Based on receiver operating characteristic (ROC) curve analysis and the z-test, thresholds were compared. Results. Using the EBJIS criteria, a cut-off of ≥ five PMN/HPF showed a sensitivity of 93% (95% confidence interval (CI) 81 to 98) and specificity of 84% (95% CI 74 to 91). The optimal threshold when applying the IDSA and ICM criteria was ≥ ten PMN/HPF with sensitivities of 94% (95% CI 79 to 99) and 90% (95% CI 76 to 97), and specificities of 86% (95% CI 77 to 92) and 92% (95% CI 84 to 97), respectively. In rTKA, a better performance of histopathological analysis was observed in comparison with rTHA when using the IDSA criteria (p < 0.001). Conclusion. With high accuracy, histopathological analysis can be supported as a confirmatory criterion in diagnosing periprosthetic joint infections. A threshold of ≥ five PMN/HPF can be recommended to distinguish between septic and aseptic loosening, with an increased possibility of detecting more infections caused by low-virulence organisms. However, neutrophil counts between one and five should be considered suggestive of infection and interpreted carefully in conjunction with other diagnostic test methods. Cite this article: Bone Joint Res 2021;10(8):536–547


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1542 - 1550
1 Dec 2018
van den Kieboom J Bosch P J. Plate JD A. IJpma FF Kuehl R McNally MA Metsemakers W M. Govaert GA

Aims. To assess the diagnostic value of C-reactive protein (CRP), leucocyte count (LC), and erythrocyte sedimentation rate (ESR) in late fracture-related infection (FRI). Materials and Methods. PubMed, Embase, and Cochrane databases were searched focusing on the diagnostic value of CRP, LC, and ESR in late FRI. Sensitivity and specificity combinations were extracted for each marker. Average estimates were obtained using bivariate mixed effects models. Results. A total of 8284 articles were identified but only six were suitable for inclusion. Sensitivity of CRP ranged from 60.0% to 100.0% and specificity from 34.3% to 85.7% in all publications considered. Five articles were pooled for meta-analysis, showing a sensitivity and specificity of 77.0% and 67.9%, respectively. For LC, this was 22.9% to 72.6%, and 73.5% to 85.7%, respectively, in five articles. Four articles were pooled for meta-analysis, resulting in a 51.7% sensitivity and 67.1% specificity. For ESR, sensitivity and specificity ranged from 37.1% to 100.0% and 59.0% to 85.0%, respectively, in five articles. Three articles were pooled in meta-analysis, showing a 45.1% sensitivity and 79.3% specificity. Four articles analyzed the value of combined inflammatory markers, reporting an increased diagnostic accuracy. These results could not be pooled due to heterogeneity. Conclusion. The serum inflammatory markers CRP, LC, and ESR are insufficiently accurate to diagnose late FRI, but they may be used as a suggestive sign in its diagnosis


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1373 - 1380
1 Oct 2017
Rienmüller A Buchmann N Kirschke JS Meyer EL Gempt J Lehmberg J Meyer B Ryang YM

Aims. We aimed to retrospectively assess the accuracy and safety of CT navigated pedicle screws and to compare accuracy in the cervical and thoracic spine (C2-T8) with (COMB) and without (POST) prior anterior surgery (anterior cervical discectomy or corpectomy and fusion with ventral plating: ACDF/ACCF). Patients and Methods. A total of 592 pedicle screws, which were used in 107 consecutively operated patients (210 COMB, 382 POST), were analysed. The accuracy of positioning was determined according to the classification of Gertzbein and Robbins on post-operative CT scans. Results. High accuracy was achieved in 524 screws (88.5%), 192 (87.7%) in the cervical spine and 332 (89%) in the thoracic spine, respectively. The results in the two surgical groups were compared and a logistic regression mixed model was performed to analyse the risk of low accuracy. Significantly lower accuracy was found in the COMB group with 82.9% versus 91.6% in the POST group (p = 0.036). There were no neurological complications, but two vertebral artery lesions were recorded. Three patients underwent revision surgery for malpositioning of a screw. Although the risk of malpositioning of a screw after primary anterior surgery was estimated to be 2.4-times higher than with posterior surgery alone, the overall rates of complication and revision were low. Conclusion. We therefore conclude that CT navigated pedicle screws can be positioned safely although greater caution must be taken in patients who have previously undergone anterior surgery. Cite this article: Bone Joint J 2017;99-B:1373–80


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 601 - 605
1 May 2006
Pitto RP Graydon AJ Bradley L Malak SF Walker CG Anderson IA

The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion/extension, varus/valgus and rotational planes. Using a digital caliper unit to measure the coordinates precisely, a software program was developed to convert these local coordinates into a determination of actual leg alignment. At specific points in the procedure, information was compared between the digital caliper measurements and the image-free navigation system. Repeated serial measurements were undertaken. In the setting of normal alignment the mean error of the system was within 0.5°. In the setting of abnormal plane alignment in both the femur and the tibia, the error was within 1°. This is the first study designed to assess the accuracy of a clinically-validated navigation system. It demonstrates in vitro accuracy of the image-free navigation system in both normal and abnormal leg alignment settings


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1406 - 1409
1 Oct 2016
Cundall-Curry DJ Lawrence JE Fountain DM Gooding CR

Aims. We present an audit comparing our level I major trauma centre’s data for a cohort of patients with hip fractures in the National Hip Fracture Database (NHFD) with locally held data on these patients. Patients and Methods. A total of 2036 records for episodes between July 2009 and June 2014 were reviewed. . Results. The demographics of nine patients were recorded incorrectly. The rate of incorrect data in operation codes was most significant with overall accuracy of 0.637 (95% CI 0.615 to 0.658). The sensitivity of NHFD coding ranged from 0.250 to 1.000 and the specificity 0.879 to 0.999. The recording of cementation had a sensitivity of 0.932 and specificity of 0.713. The recording of total hip arthroplasty had a sensitivity of 0.739 and specificity of 0.983. The overall accuracy of mortality data was 0.942 (95% CI 0.931 to 0.952), with sensitivity of 0.967 and specificity of 0.419. Conclusion. This paper highlights the need for local audit of the integrity of data uploaded to the NHFD. Cite this article: Bone Joint J 2016;98-B:1406–9


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 333 - 340
1 Mar 2009
Sariali E Mouttet A Pasquier G Durante E Catone Y

Pre-operative computerised three-dimensional planning was carried out in 223 patients undergoing total hip replacement with a cementless acetabular component and a cementless modular-neck femoral stem. Components were chosen which best restored leg length and femoral offset. The post-operative restoration of the anatomy was assessed by CT and compared with the pre-operative plan. The component implanted was the same as that planned in 86% of the hips for the acetabular implant, 94% for the stem, and 93% for the neck-shaft angle. The rotational centre of the hip was restored with a mean accuracy of 0.73 mm (. sd. 3.5) craniocaudally and 1.2 mm (. sd. 2) laterally. Limb length was restored with a mean accuracy of 0.3 mm (. sd. 3.3) and femoral offset with a mean accuracy of 0.8 mm (. sd. 3.1). This method appears to offer high accuracy in hip reconstruction as the difficulties likely to be encountered when restoring the anatomy can be anticipated and solved pre-operatively by optimising the selection of implants. Modularity of the femoral neck helped to restore the femoral offset and limb length


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 597 - 603
1 May 2014
Nomura T Naito M Nakamura Y Ida T Kuroda D Kobayashi T Sakamoto T Seo H

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs. Cite this article: Bone Joint J 2014; 96-B:597–603


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1218 - 1229
1 Oct 2019
Lerch TD Eichelberger P Baur H Schmaranzer F Liechti EF Schwab JM Siebenrock KA Tannast M

Aims. Abnormal femoral torsion (FT) is increasingly recognized as an additional cause for femoroacetabular impingement (FAI). It is unknown if in-toeing of the foot is a specific diagnostic sign for increased FT in patients with symptomatic FAI. The aims of this study were to determine: 1) the prevalence and diagnostic accuracy of in-toeing to detect increased FT; 2) if foot progression angle (FPA) and tibial torsion (TT) are different among patients with abnormal FT; and 3) if FPA correlates with FT. Patients and Methods. A retrospective, institutional review board (IRB)-approved, controlled study of 85 symptomatic patients (148 hips) with FAI or hip dysplasia was performed in the gait laboratory. All patients had a measurement of FT (pelvic CT scan), TT (CT scan), and FPA (optical motion capture system). We allocated all patients to three groups with decreased FT (< 10°, 37 hips), increased FT (> 25°, 61 hips), and normal FT (10° to 25°, 50 hips). Cluster analysis was performed. Results. We found a specificity of 99%, positive predictive value (PPV) of 93%, and sensitivity of 23% for in-toeing (FPA < 0°) to detect increased FT > 25°. Most of the hips with normal or decreased FT had no in-toeing (false-positive rate of 1%). Patients with increased FT had significantly (p < 0.001) more in-toeing than patients with decreased FT. The majority of the patients (77%) with increased FT walk with a normal foot position. The correlation between FPA and FT was significant (r = 0.404, p < 0.001). Five cluster groups were identified. Conclusion. In-toeing has a high specificity and high PPV to detect increased FT, but increased FT can be missed because of the low sensitivity and high false-negative rate. These results can be used for diagnosis of abnormal FT in patients with FAI or hip dysplasia undergoing hip arthroscopy or femoral derotation osteotomy. However, most of the patients with increased FT walk with a normal foot position. This can lead to underestimation or misdiagnosis of abnormal FT. We recommend measuring FT with CT/MRI scans in all patients with FAI. Cite this article: Bone Joint J 2019;101-B:1218–1229


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 677 - 682
1 Jun 2020
Katzouraki G Zubairi AJ Hershkovich O Grevitt MP

Aims. Diagnosis of cauda equina syndrome (CES) remains difficult; clinical assessment has low accuracy in reliably predicting MRI compression of the cauda equina (CE). This prospective study tests the usefulness of ultrasound bladder scans as an adjunct for diagnosing CES. Methods. A total of 260 patients with suspected CES were referred to a tertiary spinal unit over a 16-month period. All were assessed by Board-eligible spinal surgeons and had transabdominal ultrasound bladder scans for pre- and post-voiding residual (PVR) volume measurements before lumbosacral MRI. Results. The study confirms the low predictive value of ‘red flag’ symptoms and signs. Of note ‘bilateral sciatica’ had a sensitivity of 32.4%, and a positive predictive value (PPV) of only 17.2%, and negative predictive value (NPV) 88.3%. Use of a PVR volume of ≥ 200 ml was a demonstrably more accurate test for predicting cauda equina compression on subsequent MRI (p < 0.001). The PVR sensitivity was 94.1%, specificity 66.8%, PPV 29.9% and NPV 98.7%. The PVR allowed risk-stratification with 13% patients deemed ‘low-risk’ of CES. They had non-urgent MRI scans. None of the latter scans showed any cauda equina compression (p < 0.006) or individuals developed subsequent CES in the intervening period. There were considerable cost-savings associated with the above strategy. Conclusion. This is the largest reported prospective evaluation of suspected CES. Use of the PVR volume ≥ 200 ml was considerably more accurate in predicting CES. It is a useful adjunct to conventional clinical assessment and allows risk-stratification in managing suspected CES. If adopted widely it is less likely incomplete CES would be missed. Cite this article: Bone Joint J 2020;102-B(6):677–682


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1120 - 1125
1 Aug 2012
Alazzawi S Bardakos NV Hadfield SG Butt U Beer ZH Field RE

Using general practitioner records and hospital notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications gathered from a self-completed questionnaire after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with a mean age of 71.8 years (34 to 93). A total of 319 reported complications (79.4%; 95% confidence interval 75.4 to 83.3) were confirmed to be correct. High rates of correct reporting were demonstrated for infection (94.5%) and the need for further surgery (100%), whereas the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism, myocardial infarction and stroke were lower (75% to 84.2%). Dislocation, peri-prosthetic fractures and nerve palsy had modest rates of correct reporting (36% to 57.1%). More patients who had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013). Despite these variations, it appears that post-operative complications may form part of a larger patient-reported outcome programme after elective joint replacement surgery


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 970 - 977
1 Aug 2019
Kleiss S Jandl NM Novo de Oliveira A Rüther W Niemeier A

Aims. The aim of this study was to evaluate the diagnostic accuracy of the synovial alpha-defensin enzyme-linked immunosorbent assay (ELISA) for the diagnosis of prosthetic joint infection (PJI) in the work-up prior to revision of total hip (THA) and knee arthroplasty (TKA). Patients and Methods. Inclusion criteria for this prospective cohort study were acute or chronic symptoms of the index joint without specific exclusion criteria. Synovial fluid aspirates of 202 patients were analyzed and semiquantitative laboratory alpha-defensin ELISA was performed. Final diagnosis of PJI was established by examination of samples obtained during revision surgery. Results. Sensitivity and specificity of the alpha-defensin ELISA for PJI were 78.2% (95% confidence interval (CI) 66.7 to 88.5) and 96.6% (95% CI 93.0 to 99.3). Positive and negative predictive values were 89.6% (95% CI 80.6 to 97.8) and 92.2% (95% CI 87.5 to 96.1). The test remained false-negative in 22% of septic revisions, most of which were due to coagulase-negative staphylococci all occurring in either late-chronic or early-postoperative PJI. Conclusion. The routine use of synovial fluid alpha-defensin laboratory ELISA in the preoperative evaluation of symptomatic THAs and TKAs is insufficient to accurately diagnose PJI. Particularly in cases involving low-virulence organisms, such as coagulase-negative staphylococci, there remains a need for tests with a higher sensitivity. Cite this article: Bone Joint J 2019;101-B:970–977


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. Cite this article: Bone Joint J 2015; 97-B:1111–17


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1052 - 1061
1 Aug 2014
Thienpont E Schwab PE Fennema P

We conducted a meta-analysis, including randomised controlled trials (RCTs) and cohort studies, to examine the effect of patient-specific instruments (PSI) on radiological outcomes after total knee replacement (TKR) including: mechanical axis alignment and malalignment of the femoral and tibial components in the coronal, sagittal and axial planes, at a threshold of > 3º from neutral. Relative risks (RR) for malalignment were determined for all studies and for RCTs and cohort studies separately. Of 325 studies initially identified, 16 met the eligibility criteria, including eight RCTs and eight cohort studies. There was no significant difference in the likelihood of mechanical axis malalignment with PSI versus conventional TKR across all studies (RR = 0.84, p = 0.304), in the RCTs (RR = 1.14, p = 0.445) or in the cohort studies (RR = 0.70, p = 0.289). The results for the alignment of the tibial component were significantly worse using PSI TKR than conventional TKR in the coronal and sagittal planes (RR = 1.75, p = 0.028; and RR = 1.34, p = 0.019, respectively, on pooled analysis). PSI TKR showed a significant advantage over conventional TKR for alignment of the femoral component in the coronal plane (RR = 0.65, p = 0.028 on pooled analysis), but not in the sagittal plane (RR = 1.12, p = 0.437). Axial alignment of the tibial (p = 0.460) and femoral components (p = 0.127) was not significantly different. We conclude that PSI does not improve the accuracy of alignment of the components in TKR compared with conventional instrumentation. Cite this article: Bone Joint J 2014; 96-B:1052–61


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 993 - 1000
1 Jul 2013
Lee SC Shim JS Seo SW Lim KS Ko KR

We compared the accuracy of the growth remaining method of assessing leg-length discrepancy (LLD) with the straight-line graph method, the multiplier method and their variants. We retrospectively reviewed the records of 44 patients treated by percutaneous epiphysiodesis for LLD. All were followed up until maturity. We used the modified Green–Anderson growth-remaining method (Method 1) to plan the timing of epiphysiodesis. Then we presumed that the other four methods described below were used pre-operatively for calculating the timing of epiphysiodesis. We then assumed that these four methods were used pre-operatively. Method 2 was the original Green–Anderson growth-remaining method; Method 3, Paley’s multiplier method using bone age; Method 4, Paley’s multiplier method using chronological age; and Method 5, Moseley’s straight-line graph method. We compared ‘Expected LLD at maturity with surgery’ with ‘Final LLD at maturity with surgery’ for each method. Statistical analysis revealed that ‘Expected LLD at maturity with surgery’ was significantly different from ‘Final LLD at maturity with surgery’. Method 2 was the most accurate. There was a significant correlation between ‘Expected LLD at maturity with surgery’ and ‘Final LLD at maturity with surgery’, the greatest correlation being with Method 2. Generally all the methods generated an overcorrected value. No method generates the precise ‘Expected LLD at maturity with surgery’. It is essential that an analysis of the pattern of growth is taken into account when predicting final LLD. As many additional data as possible are required. Cite this article: Bone Joint J 2013;95-B:993–1000


Bone & Joint Research
Vol. 4, Issue 1 | Pages 1 - 5
1 Jan 2015
Vázquez-Portalatín N Breur GJ Panitch A Goergen CJ

Objective . Dunkin Hartley guinea pigs, a commonly used animal model of osteoarthritis, were used to determine if high frequency ultrasound can ensure intra-articular injections are accurately positioned in the knee joint. Methods. A high-resolution small animal ultrasound system with a 40 MHz transducer was used for image-guided injections. A total of 36 guinea pigs were anaesthetised with isoflurane and placed on a heated stage. Sterile needles were inserted directly into the knee joint medially, while the transducer was placed on the lateral surface, allowing the femur, tibia and fat pad to be visualised in the images. B-mode cine loops were acquired during 100 µl. We assessed our ability to visualise 1) important anatomical landmarks, 2) the needle and 3) anatomical changes due to the injection. . Results. From the ultrasound images, we were able to visualise clearly the movement of anatomical landmarks in 75% of the injections. The majority of these showed separation of the fat pad (67.1%), suggesting the injections were correctly delivered in the joint space. We also observed dorsal joint expansion (23%) and patellar tendon movement (10%) in a smaller subset of injections. Conclusion. The results demonstrate that this image-guided technique can be used to visualise the location of an intra-articular injection in the joints of guinea pigs. Future studies using an ultrasound-guided approach could help improve the injection accuracy in a variety of anatomical locations and animal models, in the hope of developing anti-arthritic therapies. Cite this article: Bone Joint Res 2015;4:1–5


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 351 - 357
1 Mar 2017
Sousa R Serrano P Gomes Dias J Oliveira JC Oliveira A

Aims. The aims of this study were to increase the diagnostic accuracy of the analysis of synovial fluid in the differentiation of prosthetic joint infection (PJI) by the addition of inexpensive biomarkers such as the levels of C-reactive protein (CRP), adenosine deaminase (ADA), alpha-2-macrogloblulin (α2M) and procalcitonin. Patients and Methods. Between January 2013 and December 2015, synovial fluid and removed implants were requested from 143 revision total joint arthroplasties. A total of 55 patients met inclusion criteria of the receipt of sufficient synovial fluid, tissue samples and removed implants for analysis. The diagnosis of PJI followed the definition from a recent International Consensus Meeting to create two groups of patients; septic and aseptic. Using receiver operating characteristic curves we determined the cutoff values and diagnostic accuracy for each marker. Results. There were 23 PJIs and 32 patients with aseptic loosening. The levels of total leucocyte count, proportion of polymorphonuclear leucocytes (PMNs), CRP, ADA and α2M in the synovial fluid were all significantly higher in those with a PJI than in those with aseptic loosening. The levels of procalcitonin were comparable in the two groups. Cutoff values for the optimal performance in the diagnosis of infection were: total leucocyte count > 1463 cells/μL (sensitivity (Sens) 100%, specificity (Spec) 71.9%, positive predictive value (PPV) 71.9%, negative predictive value (NPV) 100%); proportion of PMNs > 81% (Sens 78.3%, Spec 75.0%, PPV 69.2%, NPV 82.8%); CRP > 6.7mg/L (Sens 78.3%, Spec 93.8%, PPV 90.0%, NPV 85.7%); ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%) and α2M > 958 mg/L (Sens 47.8%, Spec 96.9%, PPV 91.7%, NPV 72.1%). The addition of a raised level of CRP or ADA to the total leukocyte count increased the specificity: total leukocyte count > 1463 cells/μL and CRP > 6.7mg/L (Sens 78.3%, Spec 100%, PPV 100%, NPV 86.5%) or with ADA > 61U/L (Sens 78.3%, Spec 96.9%, PPV 94.7%, NPV 86.1%). . Conclusion. The total leucocyte count in the synovial fluid offers great negative predictive value in the diagnosis of PJI and the addition of more specific markers such as CRP and ADA improves the positive predictive value. Thus the addition of simple and inexpensive markers to the measurement of the leucocyte count in the synovial fluid may reduce the number of equivocal results which demand more expensive investigation. Cite this article: Bone Joint J 2017;99-B:351–7


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 903 - 906
1 Jul 2009
Trickett RW Hodgson P Forster MC Robertson A

We aimed to determine the reliability, accuracy and the clinical role of digital templating in the pre-operative work-up for total knee replacement. Initially a sample of ten pre-operative digital radiographs were templated by four independent observers to determine the inter- and intra-observer reliability of the process. Digital templating was then performed on the radiographs of 40 consecutive patients undergoing total knee replacement by a consultant surgeon not involved with the operation, who was blinded to the size of the implant inserted. The Press Fit Condylar Sigma Knee system was used in all the patients. The size of the implant as judged by templating was then compared to that of the size used. Good inter- and intra-observer agreement was demonstrated for both femoral and tibial templating. However, the correct size of the implant was predicted in only 48% of the femoral and 55% of the tibial components. Albeit reproducible, digital templating does not currently predict the correct size of component often enough to be of clinical benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 581 - 585
1 May 2006
Oddy MJ Jones MJ Pendegrass CJ Pilling JR Wimhurst JA

In 20 patients undergoing hybrid total hip arthroplasty, the reproducibility and accuracy of templating using digital radiographs were assessed. Digital images were manipulated using either a ten-pence coin as a marker to scale for magnification, or two digital-line methods using computer software. On-screen images were templated with standard acetate templates and compared with templating performed on hard-copy digital prints. The digital-line methods were the least reliable and accuracy of sizing compared with the inserted prostheses varied between −1.6% and +10.2%. The hard-copy radiographs showed better reproducibility than the ten-pence coin method, but were less accurate with 3.7% undersizing. The ten-pence coin method was the most accurate, with no significant differences for offset or acetabulum, and undersizing of only 0.9%. On-screen templating of digital radiographs with standard acetate templates is accurate and reproducible if a radiopaque marker such as a ten-pence coin is included when the original radiograph is taken


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 266 - 272
1 Mar 1999
Biedermann R Krismer M Stöckl B Mayrhofer P Ornstein E Franzén H

Several methods of measuring the migration of the femoral component after total hip replacement have been described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible. We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Röntgen-Analyse) to determine its accuracy using three independent assessments, including a direct comparison with the results of roentgen stereophotogrammetric analysis (RSA). The accuracy of EBRA-FCA was better than ±1.5 mm (95% percentile) with a Cronbach’s coefficient alpha for interobserver reliability of 0.84; a very good result. The method had a specificity of 100% and a sensitivity of 78% compared with RSA for the detection of migration of over 1 mm. This is accurate enough to assess the stability of a prosthesis within a relatively limited period. The best reference line for downward migration is between the greater trochanter and the shoulder of the stem, as confirmed by two experimental analyses and a computer-assisted design


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 59 - 65
1 Jul 2021
Bracey DN Hegde V Shimmin AJ Jennings JM Pierrepont JW Dennis DA

Aims

Cross-table lateral (CTL) radiographs are commonly used to measure acetabular component anteversion after total hip arthroplasty (THA). The CTL measurements may differ by > 10° from CT scan measurements but the reasons for this discrepancy are poorly understood. Anteversion measurements from CTL radiographs and CT scans are compared to identify spinopelvic parameters predictive of inaccuracy.

Methods

THA patients (n = 47; 27 males, 20 females; mean age 62.9 years (SD 6.95)) with preoperative spinopelvic mobility, radiological analysis, and postoperative CT scans were retrospectively reviewed. Acetabular component anteversion was measured on postoperative CTL radiographs and CT scans using 3D reconstructions of the pelvis. Two cohorts were identified based on a CTL-CT error of ≥ 10° (n = 11) or < 10° (n = 36). Spinopelvic mobility parameters were compared using independent-samples t-tests. Correlation between error and mobility parameters were assessed with Pearson’s coefficient.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 366 - 371
1 Apr 2004
Nabeyama R Matsuda S Miura H Mawatari T Kawano T Iwamoto Y

Our study evaluated the accuracy of an image-guided total knee replacement system based on CT with regard to preparation of the femoral and tibial bone using nine limbs from five cadavers. The accuracy was assessed by direct measurement using an extramedullary alignment rod without radiographs. The mean angular errors of the femur and tibia, which represent angular gaps from the real mechanical axis in the coronal plane, were 0.3° and 1.1°, respectively. The CT-based system, provided almost perfect alignment of the femoral component with less than 1° of error and excellent alignment with less than 3° of error for the tibial component. Our results suggest that standardisation of knee replacement by the use of this system will lead to improved long-term survival of total knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 963 - 964
1 Nov 1996
Krettek C Blauth M Miclau T Rudolf J Könemann B Schandelmaier P

The accuracy of templates used for the preoperative planning of the fixation of intramedullary fractures depends on radiological magnification. To study the accuracy of these templates, we randomly selected 100 femoral and 100 tibial radiographs taken after stabilisation by an intramedullary nail using a standard technique. We then compared the known nail length with the corresponding measurements on the radiographs. The mean magnification factor for the femur was 9% and for the tibia 7%; these differ considerably from the range of magnification of the manufacturers’ templates (femur, 15% to 17%; tibia 10% to 15%). We conclude that templates are unreliable for the selection of implant length and that this should be done by intraoperative measurements


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1045 - 1048
1 Aug 2008
Shetty AA Tindall AJ James KD Relwani J Fernando KW

The diagnosis of a meniscal tear may require MRI, which is costly. Ultrasonography has been used to image the meniscus, but there are no reliable data on its accuracy. We performed a prospective study investigating the sensitivity and specificity of ultrasonography in comparison with MRI; the final outcome was determined at arthroscopy. The study included 35 patients with a mean age of 47 years (14 to 73). There was a sensitivity of 86.4% (95% confidence interval (CI) 75 to 97.7), a specificity of 69.2% (95% CI 53.7 to 84.7), a positive predictive value of 82.6% (95% CI 70 to 95.2) and a negative predictive value of 75% (95% CI 60.7 to 81.1) for ultrasonography. This compared favourably with a sensitivity of 86.4% (95% CI 75 to 97.7), a specificity of 100.0%, a positive predictive value of 100.0% and a negative predictive value of 81.3% (95% CI 74.7 to 87.9) for MRI. Given that the sensitivity matched that of MRI we feel that ultrasonography can reasonably be applied to confirm the clinical diagnosis before undertaking arthroscopy. However, the lower specificity suggests that there is still a need to improve the technique to reduce the number of false-positive diagnoses and thus to avoid unnecessary arthroscopy


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 767 - 771
1 Jul 2001
Biedermann R Stöckl B Krismer M Mayrhofer P Ornstein E Franzén H

Our aim was to determine whether tantalum markers improved the accuracy and/or precision of methods for the measurement of migration in total hip replacement based on conventional measurements without mathematical correction of the data, and with Ein Bild Roentgen Analyse – Femoral Component Analysis (EBRA-FCA) which allows a computerised correction. Three observers independently analysed 13 series of roentgen-stereophotogrammetric-analysis (RSA)-compatible radiographs (88). Data were obtained from conventional measurements, EBRA-FCA and the RSA method and all the results were compared with the RSA data. Radiological evaluation was also used to quantify in how many radiographs the intraosseous position of the bone markers had been simulated. The results showed that tantalum markers improve reliability whereas they do not affect accuracy for conventional measurements and for EBRA-FCA. Because of the danger of third-body wear their implantation should be avoided unless they are an integral part of the method


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 780 - 785
1 Jun 2015
Baauw M van Hellemondt GG van Hooff ML Spruit M

We evaluated the accuracy with which a custom-made acetabular component could be positioned at revision arthroplasty of the hip in patients with a Paprosky type 3 acetabular defect. A total of 16 patients with a Paprosky type 3 defect underwent revision surgery using a custom-made trabecular titanium implant. There were four men and 12 women with a median age of 67 years (48 to 79). The planned inclination (INCL), anteversion (AV), rotation and centre of rotation (COR) of the implant were compared with the post-operative position using CT scans. A total of seven implants were malpositioned in one or more parameters: one with respect to INCL, three with respect to AV, four with respect to rotation and five with respect to the COR. To the best of our knowledge, this is the first study in which CT data acquired for the pre-operative planning of a custom-made revision acetabular implant have been compared with CT data on the post-operative position. The results are encouraging. Cite this article: Bone Joint J 2015; 97-B:780–5


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1126 - 1131
1 Aug 2015
Nortunen S Flinkkilä T Lantto I Kortekangas T Niinimäki J Ohtonen P Pakarinen H

We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination–external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test. For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). . In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result. Cite this article: Bone Joint J 2015; 97-B:1126–31


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 323 - 326
1 Mar 2007
Citak M Kendoff D Kfuri M Pearle A Krettek C Hüfner T

The aim of this pilot study was to evaluate the accuracy of two different methods of navigated retrograde drilling of talar lesions. Artificial osteochondral talar lesions were created in 14 cadaver lower limbs. Two methods of navigated drilling were evaluated by one examiner. Navigated Iso-C. 3D. was used in seven cadavers and 2D fluoroscopy-based navigation in the remaining seven. Of 14 talar lesions, 12 were successfully targeted by navigated drilling. In both cases of inaccurate targeting the 2D fluoroscopy-based navigation was used, missing lesions by 3 mm and 5 mm, respectively. The mean radiation time was increased using Iso-C. 3D. navigation (23 s; 22 to 24) compared with 2D fluoroscopy-based navigation (14 s, 11 to 17)


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 211 - 213
1 Mar 1985
Daruwalla J Balasubramaniam P

Moire topography was added to school scoliosis screening in Singapore in 1982. The results from 1342 topographs, assessed in isolation, were used to study the accuracy of the method in predicting the radiographic location and magnitude of scoliotic curves. Accuracy in identifying the site of the curve was 68% in the thoracic spine, 54% in the thoracolumbar spine, and 15% in the lumbar region. There were 12.7% false-positive results and 4.3% false negatives. Of patients with a deviation of one moire fringe, 76.5% had a curve of 15 degrees or less; of those with a deviation of four moire fringes, 69% had a curve greater than 26 degrees. The prediction of the Cobb angle was less accurate when there was a deviation of two or three fringes. It is suggested that moire topography as a screening device should be reserved for use in the second tier of screening, since the forward-bending test is an effective and cheap method for the first tier of a mass school-screening programme


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 557 - 560
1 Apr 2007
Davis ET Gallie P Macgroarty K Waddell JP Schemitsch E

A cadaver study using six pairs of lower limbs was conducted to investigate the accuracy of computer navigation and standard instrumentation for the placement of the Birmingham Hip Resurfacing femoral component. The aim was to place all the femoral components with a stem-shaft angle of 135°. The mean stem-shaft angle obtained in the standard instrumentation group was 127.7° (120° to 132°), compared with 133.3° (131° to 139°) in the computer navigation group (p = 0.03). The scatter obtained with computer-assisted navigation was approximately half that found using the conventional jig. Computer navigation was more accurate and more consistent in its placement of the femoral component than standard instrumentation. We suggest that image-free computer-assisted navigation may have an application in aligning the femoral component during hip resurfacing


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1049 - 1053
1 Aug 2009
Braunstein V Kirchhoff C Ockert B Sprecher CM Korner M Mutschler W Wiedemann E Biberthaler P

In 100 patients the fulcrum axis which is the line connecting the anterior tip of the coracoid and the posterolateral angle of the acromion, was used to position true anteroposterior radiographs of the shoulder. This method was then compared with the conventional radiological technique in a further 100 patients. Three orthopaedic surgeons counted the number of images without overlap between the humeral head and glenoid and calculated the amount of the glenoid surface visible in each radiograph. The analysis was repeated for intraobserver reliability. The learning curves of both techniques were studied. The amount of free visible glenoid space was significantly higher using the fulcrum-axis method (64 vs 31) and the comparable glenoid size increased significantly (8.56 vs 6.47). Thus the accuracy of the anteroposterior radiographs of the shoulder is impaired by using this technique. The intra and interobserver reliability showed a high consistency. No learning curve was observed for either technique