Advertisement for orthosearch.org.uk
Results 1 - 20 of 43
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 543 - 549
1 Aug 1988
Kojimoto H Yasui N Goto T Matsuda S Shimomura Y

The histology and mechanics of leg lengthening by callus distraction were studied in 27 growing rabbits. Tibial diaphyses were subjected to subperiosteal osteotomy, held in a neutral position for 10 days and then slowly distracted at 0.25 mm/12 hours, using a dynamic external fixator. Radiographs showed that the gap became filled with callus having three distinct zones. Elongation appeared to occur in a central radiolucent zone; this was bounded by two sclerotic zones. Histologically, the radiolucent zone consisted of longitudinally arranged cartilage and fibrous tissue while the sclerotic zones were formed by fine cancellous bone. New bone occasionally contained islands of cartilage, suggesting it had been formed by endochondral ossification. After completion of distraction, the two sclerotic zones fused, shrank and were eventually absorbed, leaving tubular bone with a new cortex. When the periosteum had been removed at the operation, callus formation was markedly disturbed and there was failure of bone lengthening. Scraping of endosteum, in contrast, did not have a pronounced effect. These results suggest that the preservation of periosteum is essential if bone lengthening by callus distraction is to succeed, and that preservation of the periosteum is more important than careful corticotomy


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1731 - 1735
1 Nov 2021
Iobst CA Frost MW Rölfing JD Rahbek O Bafor A Duncan M Kold S

Aims

Limb-lengthening nails have largely replaced external fixation in limb-lengthening and reconstructive surgery. However, the adverse events and high prevalence of radiological changes recently noted with the STRYDE lengthening nail have raised concerns about the use of internal lengthening nails. The aim of this study was to compare the prevalence of radiological bone abnormalities between STRYDE, PRECICE, and FITBONE nails prior to nail removal.

Methods

This was a retrospective case series from three centres. Patients were included if they had either of the three limb-lengthening nails (STYDE, PRECICE, or FITBONE) removed. Standard orthogonal radiographs immediately prior to nail removal were examined for bone abnormalities at the junction of the telescoping nail parts.


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims

The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator.

Patients and Methods

Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1241 - 1245
1 Sep 2012
Burghardt RD Paley D Specht SC Herzenberg JE

Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients (mean age 32 years (16 to 57)). Patients who underwent simultaneous realignment procedures or concurrent tibial lengthening, or who developed mal- or nonunion, were excluded. Pre-operative and six-month post-operative radiographs were used to measure lower limb alignment. The mean lengthening achieved was 4.4 cm (1.5 to 8.0). In 26 of 27 limbs, the mechanical axis shifted laterally by a mean of 1.0 mm/cm of lengthening (0 to 3.5). In one femur that was initially in varus, a 3 mm medial shift occurred during a lengthening of 2.2 cm.

In a normally aligned limb, intramedullary lengthening along the anatomical axis of the femur results in a lateral shift of the mechanical axis by approximately 1 mm for each 1 cm of lengthening.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 751 - 758
1 Jul 2024
Yaxier N Zhang Y Song J Ning B

Aims

Given the possible radiation damage and inaccuracy of radiological investigations, particularly in children, ultrasound and superb microvascular imaging (SMI) may offer alternative methods of evaluating new bone formation when limb lengthening is undertaken in paediatric patients. The aim of this study was to assess the use of ultrasound combined with SMI in monitoring new bone formation during limb lengthening in children.

Methods

In this retrospective cohort study, ultrasound and radiograph examinations were performed every two weeks in 30 paediatric patients undergoing limb lengthening. Ultrasound was used to monitor new bone formation. The number of vertical vessels and the blood flow resistance index were compared with those from plain radiographs.


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 293 - 302
1 Mar 2024
Vogt B Lueckingsmeier M Gosheger G Laufer A Toporowski G Antfang C Roedl R Frommer A

Aims

As an alternative to external fixators, intramedullary lengthening nails (ILNs) can be employed for distraction osteogenesis. While previous studies have demonstrated that typical complications of external devices, such as soft-tissue tethering, and pin site infection can be avoided with ILNs, there is a lack of studies that exclusively investigated tibial distraction osteogenesis with motorized ILNs inserted via an antegrade approach.

Methods

A total of 58 patients (median age 17 years (interquartile range (IQR) 15 to 21)) treated by unilateral tibial distraction osteogenesis for a median leg length discrepancy of 41 mm (IQR 34 to 53), and nine patients with disproportionate short stature treated by bilateral simultaneous tibial distraction osteogenesis, with magnetically controlled motorized ILNs inserted via an antegrade approach, were retrospectively analyzed. The median follow-up was 37 months (IQR 30 to 51). Outcome measurements were accuracy, precision, reliability, bone healing, complications, and patient-reported outcome assessed by the Limb Deformity-Scoliosis Research Society Score (LD-SRS-30).


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 898 - 903
1 Nov 1993
Lee D Chung C Choi I

We investigated the effect of bone lengthening by callotasis on longitudinal growth of the tibia in rabbits. Ninety-nine five-week-old immature rabbits were divided into five groups according to the percentage of lengthening: group I, 10%; group II, 20%; group III, 30%; group IV, 40%; and group V, sham operation without lengthening. Corticotomy was performed at the proximal metaphysis of the left tibia and the right tibia was used as a control. The lengthening rate was 0.25 mm twice daily. Radiological, histomorphometric, and immunohistochemical studies were done on animals killed at the time of corticotomy, at the completion of lengthening, and thereafter every two weeks until 12 weeks. Tibial lengthening did not cause retardation of growth when the bone was lengthened by up to 20%. When the bone was lengthened by 30% or more, growth retardation was evident, and persisted until skeletal maturity


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1541 - 1547
1 Dec 2008
Bush PG Hall AC Macnicol MF

The mammalian growth plate is a complex structure which is essential for the elongation of long bones. However, an understanding of how the growth plate functions at the cellular level is lacking. This review, summarises the factors involved in growth-plate regulation, its failure and the consequence of injury. We also describe some of the cellular mechanisms which underpin the increase in volume of the growth-plate chondrocyte which is the major determinant of the rate and extent of bone lengthening. We show how living in situ chondrocytes can be imaged using 2-photon laser scanning microscopy to provide a quantitative analysis of their volume. This approach should give better understanding of the cellular control of bone growth in both healthy and failed growth plates


Bone & Joint Research
Vol. 10, Issue 12 | Pages 767 - 779
8 Dec 2021
Li Y Yang Y Wang M Zhang X Bai S Lu X Li Y Waldorff EI Zhang N Lee WY Li G

Aims

Distraction osteogenesis (DO) is a useful orthopaedic procedure employed to lengthen and reshape bones by stimulating bone formation through controlled slow stretching force. Despite its promising applications, difficulties are still encountered. Our previous study demonstrated that pulsed electromagnetic field (PEMF) treatment significantly enhances bone mineralization and neovascularization, suggesting its potential application. The current study compared a new, high slew rate (HSR) PEMF signal, with different treatment durations, with the standard Food and Drug Administration (FDA)-approved signal, to determine if HSR PEMF is a better alternative for bone formation augmentation.

Methods

The effects of a HSR PEMF signal with three daily treatment durations (0.5, one, and three hours/day) were investigated in an established rat DO model with comparison of an FDA-approved classic signal (three hrs/day). PEMF treatments were applied to the rats daily for 35 days, starting from the distraction phase until termination. Radiography, micro-CT (μCT), biomechanical tests, and histological examinations were employed to evaluate the quality of bone formation.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1168 - 1172
1 Jun 2021
Iliadis AD Wright J Stoddart MT Goodier WD Calder P

Aims

The STRYDE nail is an evolution of the PRECICE Intramedullary Limb Lengthening System, with unique features regarding its composition. It is designed for load bearing throughout treatment in order to improve patient experience and outcomes and allow for simultaneous bilateral lower limb lengthening. The literature published to date is limited regarding outcomes and potential problems. We report on our early experience and raise awareness for the potential of adverse effects from this device.

Methods

This is a retrospective review of prospective data collected on all patients treated in our institution using this implant. We report the demographics, nail accuracy, reliability, consolidation index, and cases where concerning clinical and radiological findings were encountered. There were 14 STRYDE nails implanted in nine patients (three male and six female) between June 2019 and September 2020. Mean age at surgery was 33 years (14 to 65). Five patients underwent bilateral lengthening (two femoral and three tibial) and four patients unilateral femoral lengthening for multiple aetiologies.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 458 - 460
1 May 1991
De Pablos J Barrios C Canadell J

Limb lengthening by means of distraction through the callus of a knee arthrodesis was performed in a 14-year-old boy with congenital hypoplasia of one lower limb. Knee arthrodesis was indicated because of destruction of the distal femoral epiphysis caused by a previous bone lengthening procedure


Bone & Joint Research
Vol. 10, Issue 7 | Pages 425 - 436
16 Jul 2021
Frommer A Roedl R Gosheger G Hasselmann J Fuest C Toporowski G Laufer A Tretow H Schulze M Vogt B

Aims

This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported.

Methods

This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 64 - 70
1 Jan 1985
Pho R Levack B Satku K Patradul A

Five cases of congenital pseudarthrosis of the tibia successfully treated by a free vascularised fibular graft are described. Follow-up ranged from 5 to 34 months with a mean of 17.5 months. The technique, which includes radical excision of abnormal bone and soft tissue around the pseudarthrosis, also permits primary bone lengthening, and correction of deformity. The early results indicate that satisfactory bony union is achieved in a relatively short period of time


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 955 - 958
1 Nov 1997
Takakura Y Tanaka Y Fujii T Tamai S

We lengthened seven first metatarsals in four patients with short great toes by callus distraction using an external fixator. Good clinical and cosmetic results were obtained. Bone lengthening is effective in patients with short great toes not only for cosmesis, but also to relieve pain and callosities on the plantar aspect of the second and third metatarsal heads. Excessive lengthening of the first metatarsal resulted in limitation of the range of movement of the metatarsophalangeal joint of the great toe. To prevent this the amount of lengthening should not exceed 40% of the preoperative length of the metatarsal


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 358 - 364
1 May 1993
Eyres K Bell M Kanis J

We studied the quantity and rate of formation of new bone during lengthening of 17 limb segments in 10 patients using dual-energy X-ray absorptiometry (DEXA), ultrasonography and radiography. Whereas new bone was detected by both DEXA and ultrasonography within 1 to 2 weeks of distraction, it was not visible on the radiographs until 4 to 8 weeks. Limb alignment and gap measurement were accurately assessed by DEXA without the need for standard radiographs or scanograms. With ultrasound the distraction gap appeared as an echolucent window which narrowed progressively producing a hyper-reflecting line after which further consolidation could not be assessed. As measured by DEXA the density of the new bone at this stage was approximately 45% of control values and did not represent normal cortication. Whereas ultrasound could be used to identify defects in mineralisation and to determine when to dynamise the fixator system, DEXA could measure the quantity and rate of formation of bone throughout lengthening


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 387 - 391
1 May 1995
de Pablos J Azcarate J Barrios C

We report the treatment in 17 patients of 27 angular deformities of the long bones by progressive opening-wedge osteotomy. The technique consists of percutaneous osteotomy and progressive angular correction using a modified Wagner distractor. Ten patients (20 bone segments) had adolescent bilateral idiopathic tibia vara with a mean angular deformity of 12 degrees varus (10 to 16). Seven other adolescent patients had secondary angular deformities either at the distal femur or the distal tibia. One of the femoral deformities had an associated 5.5 cm of shortening which was treated simultaneously. The patients with idiopathic tibia vara achieved a final mean angular correction of 15 degrees (mechanical axis from 12 degrees varus to 3 degrees valgus). In patients with secondary angular deformities the mean angular correction was 17 degrees. The Wagner device was removed in an average period of 12 weeks (9 to 27), and no major complications were observed. Progressive opening-wedge osteotomy is an alternative to conventional osteotomies for the treatment of angular deformities of the long bones in adolescent patients, and has the advantage of requiring less invasive surgery, allowing progressive and adjustable correction with bone lengthening if needed


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 824 - 830
1 Sep 1997
Yasui N Sato M Ochi T Kimura T Kawahata H Kitamura Y Nomura S

We developed a rat model of limb lengthening to study the basic mechanism of distraction osteogenesis, using a small monolateral external fixator. In 11-week-old male rats we performed a subperiosteal osteotomy in the midshaft of the femur with distraction at 0.25 mm every 12 hours from seven days after operation. Radiological and histological examinations showed a growth zone of constant thickness in the middle of the lengthened segment, with formation of new bone at its proximal and distal ends. Osteogenic cells were arranged longitudinally along the tension vector showing the origin and the fate of individual cells in a single section. Typical endochondral bone formation was prominent in the early stage of distraction, but intramembraneous bone formation became the predominant mechanism of ossification at later stages. We also showed a third mechanism of ossification, ‘transchondroid bone formation’. Chondroid bone, a tissue intermediate between bone and cartilage, was formed directly by chondrocyte-like cells, with transition from fibrous tissue to bone occurring gradually and consecutively without capillary invasion. In situ hybridisation using digoxigenin-11-UTP-labelled complementary RNAs showed that the chondroid bone cells temporarily expressed type-II collagen mRNA. They did not show the classical morphological characteristics of chondrocytes, but were assumed to be young chondrocytes undergoing further differentiation into bone-forming cells. We found at least three different modes of ossification during bone lengthening by distraction osteogenesis. We believe that this is the first report of such a rat model, and have shown the validity of in situ hybridisation techniques for the study of the cellular and molecular mechanisms involved in distraction osteogenesis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 254 - 260
1 Mar 2003
Donnan LT Saleh M Rigby AS

We have reviewed, retrospectively, all children with a lower limb deformity who underwent an acute correction and lengthening with a monolateral fixator between 1987 and 1996. The patients were all under the age of 19 years and had a minimum follow-up of eight months after removal of the fixator. A total of 41 children had 57 corrections and lengthening. Their mean age was 11.3 years (3.2 to 18.7) and there were 23 girls and 18 boys. The mean maximum correction in any one plane was 23° (7 to 45). In 41 bony segments (either femur or tibia) a uniplanar correction was made while various combinations were carried out in 16. The site of the osteotomy was predominantly diaphyseal, at a mean of 47% (17% to 73%) of the total bone length and the mean length gained was 6.4 cm (1.0 to 17.0). Univariate analysis identified a moderately strong relationship between the bone healing index (BHI), length gained, maximum correction and grade-II to grade-III complications. For logistic regression analysis the patients were binary coded into two groups; those with a good outcome (BHI ≤ 45 days/cm) and those with a poor outcome (BHI > 45 days/cm). Various factors which may influence the outcome were then analysed by calculating odds ratios with 95% confidence intervals. This analysis suggested a dose response between increasing angular correction and poor BHI which only reached statistical significance for corrections of larger magnitude. Longer lengthenings were associated with a better BHI while age and the actual bone lengthened had little effect. Those patients with a maximum angulatory correction of less than 30° in any one plane had an acceptable consolidation time with few major complications. The technique is suitable for femoral deformity and shortening, but should be used with care in the tibia since the risk of a compartment syndrome or neurapraxia is much greater


Bone & Joint 360
Vol. 3, Issue 3 | Pages 32 - 34
1 Jun 2014

The June 2014 Oncology Roundup. 360 . looks at: Infection still a problem in endoprosthetic reconstruction; massive allografts not as successful as we perhaps think; curopsy for aneurysmal bone cysts?; lengthening prosthesis: days are numbered; new WHO classification in brief; proximal tumours and fluid levels: bad news; infection is predictable in orthopaedic oncology; psychosocial support key in oncological outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1013 - 1015
1 Sep 2004
Kim JS Baek GH Chung MS Yoon PW

We performed nine metatarsal and three proximal phalangeal lengthenings in five patients with congenital brachymetatarsia of the first and one or two other metatarsal bones, by a one-stage combined shortening and lengthening procedure using intercalcary autogenous bone grafts from adjacent shortened metatarsal bones. Instead of the isolated lengthening of the first and the other metatarsal bones, we shortened the adjacent normal metatarsal and used the excised bone to lengthen the short toes, except for the great toe, to restore the normal parabola. One skin incision was used. All the operations were performed bilaterally and the patients were followed up for a mean period of 69.5 months (29 to 107). They all regained a nearly normal parabola and were satisfied with the cosmetic results. Our technique is straightforward and produces good cosmetic results. Satisfactory, bony union is achieved, morbidity is low, and no additional surgery is required for the removal of metal implants