Advertisement for orthosearch.org.uk
Results 1 - 20 of 473
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1438 - 1445
1 Nov 2020
Jang YH Lee JH Kim SH

Aims. Scapular notching is thought to have an adverse effect on the outcome of reverse total shoulder arthroplasty (RTSA). However, the matter is still controversial. The aim of this study was to determine the clinical impact of scapular notching on outcomes after RTSA. Methods. Three electronic databases (PubMed, Cochrane Database, and EMBASE) were searched for studies which evaluated the influence of scapular notching on clinical outcome after RTSA. The quality of each study was assessed. Functional outcome scores (the Constant-Murley scores (CMS), and the American Shoulder and Elbow Surgeons (ASES) scores), and postoperative range of movement (forward flexion (FF), abduction, and external rotation (ER)) were extracted and subjected to meta-analysis. Effect sizes were expressed as weighted mean differences (WMD). Results. In all, 11 studies (two level III and nine level IV) were included in the meta-analysis. All analyzed variables indicated that scapular notching has a negative effect on the outcome of RTSA . Statistical significance was found for the CMS (WMD –3.11; 95% confidence interval (CI) –4.98 to –1.23), the ASES score (WMD –6.50; 95% CI –10.80 to –2.19), FF (WMD –6.3°; 95% CI –9.9° to –2.6°), and abduction (WMD –9.4°; 95% CI –17.8° to –1.0°), but not for ER (WMD –0.6°; 95% CI –3.7° to 2.5°). Conclusion. The current literature suggests that patients with scapular notching after RTSA have significantly worse results when evaluated by the CMS, ASES score, and range of movement in flexion and abduction. Cite this article: Bone Joint J 2020;102-B(11):1438–1445


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims. The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear. Methods. Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables. Results. Univariate analysis showed that the flat-face type was more prevalent in the patients than in the control group (43% vs 21%; p = 0.002), while the C-type was lower in the patients than in the control group (3% vs 17%; p = 0.011). The depth and version angle of sigmoid notch showed a negative association with the TFCC foveal tear in the multivariate analysis (depth: odds ratio (OR) 0.380; p = 0.037; version angle: OR 0.896; p = 0.033). Estimated cut-off values were 1.34 mm for the depth (area under the curve (AUC) = 0.725) and 10.45° for the version angle (AUC = 0.726). Conclusion. The proportion of flat-face sigmoid notch type was greater in the patient group than in the control group. The depth and version angle of sigmoid notch were negatively associated with TFCC foveal injury. Cite this article: Bone Joint J 2020;102-B(6):749–754


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA). A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere. Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation. Cite this article: Bone Joint J 2013;95-B:530–5


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 369 - 375
1 Mar 2017
Ross M Wiemann M Peters SE Benson R Couzens GB

Aims. The aims of this study were: firstly, to investigate the influence of the thickness of cartilage at the sigmoid notch on the inclination of the distal radioulnar joint (DRUJ), and secondly, to compare the sensitivity and specificity of MRI with plain radiographs for the assessment of the inclination of the articular surface of the DRUJ in the coronal plane. . Patients and Methods. Contemporaneous MRI images and radiographs of 100 wrists from 98 asymptomatic patients (mean age 43 years, (16 to 67); 52 male, 53%) with no history of a fracture involving the wrist or surgery to the wrist, were reviewed. The thickness of the cartilage at the sigmoid notch, inclination of the DRUJ and Tolat Type of each DRUJ were determined. . Results. The assessment using MRI scans and cortical bone correlated well with radiographs, with a kappa value of 0.83. The mean difference between the inclination using the cortex and cartilage on MRI scans was 12°, leading to a change of Tolat type of inclination in 66% of wrists. No reverse oblique (Type 3) inclinations were found when using the cartilage to assess inclination. . Conclusion . These data revealed that when measuring the inclination of the DRUJ using cartilage, reverse oblique inclinations might not exist. The data suggest that performing an ulna shortening osteotomy might be reasonable even in distal radioulnar joints where the plain radiographic appearance suggests an unfavourable reverse oblique inclination in the coronal plane. We recommend using MRI to validate radiographs in those that appear to be reverse oblique (Tolat Type 3), as the true inclination might be different, thereby removing one possible contraindication to ulnar shortening. Cite this article: Bone Joint J 2017;99-B:369–75


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 737 - 742
1 Jun 2014
Eggerding V van Kuijk KSR van Meer BL Bierma-Zeinstra SMA van Arkel ERA Reijman M Waarsing JH Meuffels DE

We have investigated whether shape of the knee can predict the clinical outcome of patients after an anterior cruciate ligament rupture. We used statistical shape modelling to measure the shape of the knee joint of 182 prospectively followed patients on lateral and Rosenberg view radiographs of the knee after a rupture of the anterior cruciate ligament. Subsequently, we associated knee shape with the International Knee Documentation Committee subjective score at two years follow-up. The mean age of patients was 31 years (21 to 51), the majority were male (n = 121) and treated operatively (n = 135). We found two modes (shape variations) that were significantly associated with the subjective score at two years: one for the operatively treated group (p = 0.002) and one for the non-operatively treated group (p = 0.003). Operatively treated patients who had higher subjective scores had a smaller intercondylar notch and a smaller width of the intercondylar eminence. Non-operatively treated patients who scored higher on the subjective score had a more pyramidal intercondylar notch as opposed to one that was more dome-shaped. We conclude that the shape of the femoral notch and the intercondylar eminence is predictive of clinical outcome two years after a rupture of the anterior cruciate ligament. Cite this article: Bone Joint J 2014;96-B:737–42


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 413 - 416
1 Mar 2007
van Riet RP van Glabbeek F de Weerdt W Oemar J Bortier H

We undertook a study on eight arms from fresh cadavers to define the clinical usefulness of the lesser sigmoid notch as a landmark when reconstructing the length of the neck of the radius in replacement of the head with a prosthesis. The head was resected and its height measured, along with several control measurements. This was compared with in situ measurements from the stump of the neck to the proximal edge of the lesser sigmoid notch of the ulna. All the measurements were performed three times by three observers acting independently. The results were highly reproducible with intra- and interclass correlations of > 0.99. The mean difference between the measurement on the excised head and the distance from the stump of the neck and the lesser sigmoid notch was −0.02 mm (−1.24 to +0.97). This difference was not statistically significant (p = 0.78). The proximal edge of the lesser sigmoid notch provides a reliable landmark for positioning a replacement of the radial head and may have clinical application


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1475 - 1478
1 Nov 2011
Sonnery-Cottet B Archbold P Cucurulo T Fayard J Bortolletto J Thaunat M Prost T Chambat P

It has been suggested that an increased posterior tibial slope (PTS) and a narrow notch width index (NWI) increase the risk of anterior cruciate ligament (ACL) injury. The aim of this study was to establish why there are conflicting reports on their significance. A total of fifty patients with a ruptured ACL and 50 patients with an intact ACL were included in the study. The group with ACL rupture had a statistically significantly increased PTS (p < 0.001) and a smaller NWI (p < 0.001) than the control group. When a high PTS and/or a narrow NWI were defined as risk factors for an ACL rupture, 80% of patients had at least one risk factor present; only 24% had both factors present. In both groups the PTS was negatively correlated to the NWI (correlation coefficient = -0.28, p = 0.0052). Using a univariate model, PTS and NWI appear to be correlated to rupture of the ACL. Using a logistic regression model, the PTS (p = 0.006) and the NWI (p < 0.0001) remain significant risk factors. From these results, either a steep PTS or a narrow NWI predisposes an individual to ACL injury. Future studies should consider these factors in combination rather than in isolation


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 408 - 409
1 Mar 2005
Thomas S Theologis T Wainwright AM

We present simple but effective retractors used in pairs to expose the sciatic notch during Salter innominate osteotomy. We have found them to be useful for a wide range of procedures requiring similar exposure. We present them here in tribute to the memory of the designer Mercer Rang


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 271 - 273
1 Mar 1994
Portinaro N Matthews S Benson M

In the first few months of life, a notch may be seen on radiographs of the superolateral margin of the infant hip. It may be associated with a steeply inclined acetabular roof and may be an indicator of persistent neonatal instability or displacement of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 588 - 591
1 Jul 1994
Skirving A Kozak T Davis S

We describe five patients, seen since 1984, with posterior shoulder pain and isolated wasting and weakness of the infraspinatus. In four of these a ganglion in the spinoglenoid notch was demonstrated by MRI and in one recent case ultrasound scans were positive. Three patients have been treated by operation, but there was recurrence in one after five years. In each confirmed case, the ganglion straddled the base of the spine of the scapula, extending into both supraspinatus and infraspinatus fossae. The nerve was either compressed against the spine or stretched over the posterior aspect of the ganglion. Adequate surgical exposure is essential to preserve the nerve to the infraspinatus and to allow complete removal of the ganglion. This is difficult because of the location and thin-walled nature of the cysts


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1390 - 1392
1 Oct 2006
Rhee KJ Kim KC Lee JK Hwang DS Shin HD Yang JY Kim YM

In a 41-year-old man, right-sided infraspinatus muscle weakness was associated with compression of the suprascapular nerve caused by a spinoglenoid ganglion cyst. The lesion was confirmed using electromyography and MRI. In addition, arthroscopy showed an incomplete discoid labrum. The free inner edge of the labrum was removed as in a meniscectomy of a discoid meniscus in the knee joint. Arthroscopic decompression of the cyst was performed through a juxtaglenoid capsulotomy which was left open. Neurological function recovered completely.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 505 - 506
1 May 1995
Edelson J


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 647 - 653
1 Jul 1994
Eckstein F Lohe F Muller-Gerbl M Steinlechner M Putz R

In 16 cadaver humeroulnar joints, the distribution of subchondral mineralisation was assessed by CT osteoabsorptiometry and the position and size of the contact areas by polyether casting under loads of 10 N to 1280 N. Ulnas with separate olecranon and coronoid cartilaginous surfaces showed matching bicentric patterns of mineralisation. Under small loads there were separate contact areas on the olecranon and coronoid surfaces; these areas merged centrally as the load increased. They occupied as little as 9% of the total articular surface at 10 N and up to 73% at 1280 N. Ulnas with continuous cartilaginous surfaces also had density patterns with two maxima but those were less prominent, and in these specimens the separate contact areas merged at lower loads. The findings indicate a physiological incongruity of the articular surfaces which may serve to optimise the distribution of stress.


Bone & Joint Research
Vol. 13, Issue 10 | Pages 611 - 621
24 Oct 2024
Wan Q Han Q Liu Y Chen H Zhang A Zhao X Wang J

Aims. This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture. Methods. Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk. Results. During gait, varied sagittal positioning did not lead to excessive Von Mises stress or micromotion. However, under squat conditions, posterior positioning (-4 and -5 mm) resulted in stress exceeding 150 MPa at the femoral notch, indicating potential fracture risk. Conversely, +1 mm and 0 mm sagittal positions demonstrated minimal interface micromotion. Conclusion. Slightly anterior sagittal positioning (+1 mm) or neutral positioning (0 mm) effectively reduced stress concentration at the femoral notch and minimized interface micromotion. Thus, these positions are deemed suitable to decrease the risk of aseptic loosening and periprosthetic femoral fracture


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims. The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes. Methods. This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group). Results. Perforation of the vault of the glenoid (p = 0.018) and size mismatch in height (p < 0.001) and width (p = 0.013) were significantly more frequent in the ST group than in the SM group. There was no significant difference in the clinical scores and ROM in the two groups, two years postoperatively (all p > 0.05). In subgroup analysis, the VP group had significantly less inferior overhang (p = 0.009), more scapular notching (p = 0.018), and more size mismatch in height (p < 0.001) and width (p = 0.025) than the VNP group. Conclusion. In Asian patients with a small glenoid, using a 29.5 mm small baseplate at the time of RSA was more effective in reducing size mismatch between the glenoid and the baseplate, decreasing the incidence of perforation of the glenoid vault, and achieving optimal positioning of the baseplate compared with the use of a 33.8 mm standard baseplate. However, longer follow-up is required to assess the impact of these findings on the clinical outcomes. Cite this article: Bone Joint J 2023;105-B(11):1189–1195


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 268 - 276
1 Mar 2024
Park JH Lee JH Kim DY Kim HG Kim JS Lee SM Kim SC Yoo JC

Aims. This study aimed to assess the impact of using the metal-augmented glenoid baseplate (AGB) on improving clinical and radiological outcomes, as well as reducing complications, in patients with superior glenoid wear undergoing reverse shoulder arthroplasty (RSA). Methods. From January 2016 to June 2021, out of 235 patients who underwent primary RSA, 24 received a superior-AGB after off-axis reaming (Group A). Subsequently, we conducted propensity score matching in a 1:3 ratio, considering sex, age, follow-up duration, and glenoid wear (superior-inclination and retroversion), and selected 72 well-balanced matched patients who received a standard glenoid baseplate (STB) after eccentric reaming (Group B). Superior-inclination, retroversion, and lateral humeral offset (LHO) were measured to assess preoperative glenoid wear and postoperative correction, as well as to identify any complications. Clinical outcomes were measured at each outpatient visit before and after surgery. Results. There were no significant differences in demographic data and preoperative characteristics between the two groups. Both groups showed significant improvements in patient-reported outcome measures (visual analogue scale for pain, visual analogue scale for function, American Shoulder and Elbow Surgeons, Constant, and Simple Shoulder Test scores) from preoperative to final assessment (p < 0.001). However, AGB showed no additional benefit. Notably, within range of motion, Group B showed significant postoperative decrease in both external rotation and internal rotation, unlike Group A (p = 0.028 and 0.003, respectively). Both groups demonstrated a significant correction of superior-inclination after surgery, while patients in Group B exhibited a significant decrease in LHO postoperatively (p = 0.001). Regarding complications, Group A experienced more acromial stress fractures (3 cases; 12.5%), whereas Group B had a higher occurrence of scapular notching (24 cases; 33.3%) (p = 0.008). Conclusion. Both eccentric reaming with STB and off-axis reaming with AGB are effective methods for addressing superior glenoid wear in RSA, leading to improved clinical outcomes. However, it is important to be aware of the potential risks associated with eccentric reaming, which include excessive bone loss leading to reduced rotation and scapular notching. Cite this article: Bone Joint J 2024;106-B(3):268–276


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 360 - 365
1 Feb 2021
Mahendraraj KA Shields MV Grubhofer F Golenbock SW Jawa A

Aims. Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres. Methods. We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up. Results. Median postoperative inclination for each group was found to be -3.6° (interquartile range (IQR) -2.1 to -6.9) and 6.0° (3.2° to 10.1°) for the neutrally/inferiorly and superiorly inclined cohorts, respectively. Preoperative inclination was highly associated with postoperative inclination (p = 0.004). When comparing superiorly and neutrally/inferiorly inclined glenospheres, there were no differences in heterotopic ossification (p = 0.606), scapular notching (p = 0.367), American Shoulder and Elbow Surgeons score (p = 0.419), Single Assessment Numeric Evaluation (p = 0.417), Visual Analogue Scale (VAS) pain score (p = 0.290), forward elevation (p = 0.161), external rotation (p = 0.537), or internal rotation (p = 0.656). Conclusion. Compared to neutral and inferior inclination, up to 6° ± 3° of superior glenoid baseplate inclination on a lateralized RSA design produces no differences in postoperative ROM or patient-reported outcomes, and produces similar levels of scapular notching and heterotopic ossification. Additionally, the degree of preoperative inclination represents an important factor in surgical decision-making as it is strongly associated with postoperative inclination. It is important to note that the findings of this study are only reflective of lateralized RSA prostheses. Cite this article: Bone Joint J 2021;103-B(2):360–365


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 195 - 202
1 Feb 2024
Jamshidi K Kargar Shooroki K Ammar W Mirzaei A

Aims. The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach. Methods. A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and Sailhan’s functional criteria. Results. At final follow-up, the mean MSTS score was 29.1 (SD 0.9) in group A and 26.7 (SD 1.5) in group B (p = 0.006). According to Sailhan’s criteria, the knee function was good and fair in 14 (87.5%) and two (12.5%) patients of group A, and eight (57.1%) and six (42.9%) patients of group B, respectively (p = 0.062). The lesion had recurred in one patient (6.2%) in group A and four patients (28.6%) in group B. Limb shortening > 1 cm was recorded in one patient (6.2%) from group A and six patients (42.8%) from group B. Joint degeneration was noted in one patient from group A and three patients from group B. Conclusion. An intercondylar approach to a chondroblastoma of the middle two-quarters of the distal femoral epiphysis results in better outcomes than a medial or lateral epiphyseal approach: specifically, better limb function, a lower rate of recurrence, and a lower rate of physeal damage and joint degeneration. Cite this article: Bone Joint J 2024;106-B(2):195–202


Bone & Joint Open
Vol. 5, Issue 2 | Pages 147 - 153
19 Feb 2024
Hazra S Saha N Mallick SK Saraf A Kumar S Ghosh S Chandra M

Aims. Posterior column plating through the single anterior approach reduces the morbidity in acetabular fractures that require stabilization of both the columns. The aim of this study is to assess the effectiveness of posterior column plating through the anterior intrapelvic approach (AIP) in the management of acetabular fractures. Methods. We retrospectively reviewed the data from R G Kar Medical College, Kolkata, India, from June 2018 to April 2023. Overall, there were 34 acetabulum fractures involving both columns managed by medial buttress plating of posterior column. The posterior column of the acetabular fracture was fixed through the AIP approach with buttress plate on medial surface of posterior column. Mean follow-up was 25 months (13 to 58). Accuracy of reduction and effectiveness of this technique were measured by assessing the Merle d’Aubigné score and Matta’s radiological grading at one year and at latest follow-up. Results. Immediate postoperative radiological Matta’s reduction accuracy showed anatomical reduction (0 to 1 mm) in 23 cases (67.6%), satisfactory (2 to 3 mm) in nine (26.4%), and unsatisfactory (> 3 mm) in two (6%). Merle d’Aubigné score at the end of one year was calculated to be excellent in 18 cases (52.9%), good in 11 (32.3%), fair in three (8.8%), and poor in two (5.9%). Matta’s radiological grading at the end of one year was calculated to be excellent in 16 cases (47%), good in nine (26.4%), six in fair (17.6%), and three in poor (8.8%). Merle d’Aubigné score at latest follow-up deteriorated by one point in some cases, but the grading remained the same; Matta’s radiological grading at latest follow-up also remained unchanged. Conclusion. Stabilization of posterior column through AIP by medial surface plate along the sciatic notch gives good stability to posterior column, and at the same time can avoid morbidity of the additional lateral window. Cite this article: Bone Jt Open 2024;5(2):147–153


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims. The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems. Methods. An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements. Results. There were variations in jump height between rTSA systems at a given size, resulting in large differences in stability ratio between systems. Standard liners exhibited a stability ratio range from 126% to 214% (mean 158% (SD 23%)) and constrained liners a range from 151% to 479% (mean 245% (SD 76%)). The angle of coverage showed a range from 103° to 130° (mean 115° (SD 7°)) for standard and a range from 113° to 156° (mean 133° (SD 11°)) for constrained liners. Four arthroplasty systems kept the stability ratio of standard liners constant (within 5%) across different sizes, while one system showed slight inconsistencies (within 10%), and ten arthroplasty systems showed large inconsistencies (range 11% to 28%). The stability ratio of constrained liners was consistent across different sizes in two arthroplasty systems and inconsistent in seven systems (range 18% to 106%). Conclusion. Large differences in jump height and resulting degree of constraint of rTSA liners were observed between different implant systems, and in many cases even within the same implant systems. While the immediate clinical effect remains unclear, in theory the degree of constraint of the liner plays an important role for the dislocation and notching risk of a rTSA system. Cite this article: Bone Jt Open 2024;5(10):818–824