Aims. This is a prospective randomised study which compares the radiological
and functional outcomes of ring and
Aims. In this randomized study, we aimed to compare quality of regenerate in monolateral versus circular frame fixation in 30 patients with infected nonunion of tibia. Patients and Methods. Both groups were comparable in demographic and injury characteristics. A phantom (aluminium step wedge of increasing thickness) was designed to compare the density of regenerate on radiographs. A CT scan was performed at three and six months postoperatively to assess regenerate density. A total of 30 patients (29 male, one female; mean age 32.54 years (18 to 60)) with an infected nonunion of a tibial fracture presenting to our tertiary institute between June 2011 and April 2016 were included in the study. Results. The regenerate mineralization on radiographs was comparable in both groups at two, four, six, and ten months’ follow-up but the
Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator. A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.Aims
Patients and Methods
The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral locked plate and a six-pin monorail
fixator on its anteromedial surface. A corticotomy was performed
at the appropriate level. During the third stage, i.e. at the end
of the distraction phase, the transported fragment was aligned and
fixed to the plate with two to four screws. An iliac crest autograft
was added to the docking site and the fixator was removed. Functional
outcome was assessed using the Association for the Study and Application
of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes
were assessed using the Musculoskeletal Tumor Society (MSTS) score.Aims
Patients and Methods
The October 2012 Trauma Roundup360 looks at: which patients die from pelvic ring fractures; monolateral distraction osteogenesis; surgical management of pelvic and peroneal blast injuries; weekend warriors at risk of going AWOL; early experience with the locking attachment plate; and fibula nailing - an alternate, and viable technique.
We describe the technique and results of medial
submuscular plating of the femur in paediatric patients and discuss its
indications and limitations. Specifically, the technique is used
as part of a plate-after-lengthening strategy, where the period
of external fixation is reduced and the plate introduced by avoiding
direct contact with the lateral entry wounds of the external fixator
pins. The technique emphasises that vastus medialis is interposed
between the plate and the vascular structures. A total of 16 patients (11 male and five female, mean age 9.6
years (5 to 17)), had medial submuscular plating of the femur. All
underwent distraction osteogenesis of the femur with a mean lengthening
of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation
of the regenerate without deformity. The mean follow-up was 10.5 months
(7 to 15) after plating for those with plates still Placing the plate on the medial side is advantageous when the
external fixator is present on the lateral side, and is biomechanically
optimal in the presence of a femoral defect. We conclude that medial
femoral submuscular plating is a useful technique for specific indications
and can be performed safely with a prior understanding of the regional
anatomy. Cite this article: