Aims. The
Plasma levels of cobalt and chromium ions and
Metal Artefact Reduction Sequence (MARS)-MRI scans were performed
on patients with 209 consecutive, unilateral, symptomatic metal-on-metal
(MoM) hip arthroplasties. There was wide variation in plasma cobalt
and chromium levels, and MARS-MRI scans were positive for adverse reaction
to metal debris (ARMD) in 84 hips (40%). There was a significant
difference in the median plasma cobalt and chromium levels between
those with positive and negative MARS-MRI scans (p <
0.001).
Compared with MARS-MRI as the potential reference standard for the
diagnosis of ARMD, the
Aims. The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the
Aims. To evaluate the histopathological examination of peri-implant tissue samples as a technique in the diagnosis of postoperative spinal implant infection (PSII). Methods. This was a retrospective analysis. Patients who underwent revision spinal surgery at our institution were recruited for this study. PSII was diagnosed by clinical signs, histopathology, and microbiological examination of intraoperatively collected samples. Histopathology was defined as the gold standard. The
Aims. This study aimed to answer two questions: what are the best diagnostic methods for diagnosing bacterial arthritis of a native joint?; and what are the most commonly used definitions for bacterial arthritis of a native joint?. Methods. We performed a search of PubMed, Embase, and Cochrane libraries for relevant studies published between January 1980 and April 2020. Of 3,209 identified studies, we included 27 after full screening.
Blood metal ions have been widely used to investigate
metal-on-metal hip replacements, but their ability to discriminate
between well-functioning and failed hips is not known. The Medicines
and Healthcare products Regulatory Agency (MHRA) has suggested a
cut-off level of 7 parts per billion (ppb). We performed a pair-matched, case-control study to investigate
the
A prospective study of allergic contact dermatitis after metal-on-plastic total hip replacement was undertaken in 69 patients, of whom 54 were available for review after operation. Before operation six patients were metal sensitive, but only one remained so afterwards; this patient had given a clear history of metal
Aims. The aims of this study were to investigate any possible relationship
between a preoperative
Aims. The risk to patients and healthcare workers of resuming elective orthopaedic surgery following the peak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been difficult to quantify. This has prompted governing bodies to adopt a cautious approach that may be impractical and financially unsustainable. The lack of evidence has made it impossible for surgeons to give patients an informed perspective of the consequences of elective surgery in the presence of SARS-CoV-2. This study aims to determine, for the UK population, the probability of a patient being admitted with an undetected SARS-CoV-2 infection and their resulting risk of death; taking into consideration the current disease prevalence, reverse transcription-polymerase chain reaction (RT-PCR) testing, and preassessment pathway. Methods. The probability of SARS-CoV-2 infection with a false negative test was calculated using a lower-end RT-PCR
1. Evidence is presented which suggests that after total joint replacement bone necrosis and consequent loosening of the prosthesis may be due to the development of
Tissues from five patients who underwent revision operations for failed total hip replacements were found to contain large quantities of particulate titanium. In four cases this metal must have come from titanium alloy screws used to fix the acetabular component; in the fifth case it may also have originated from a titanium alloy femoral head. Monoclonal antibody labelling showed abundant macrophages and T-lymphocytes, in the absence of B-lymphocytes, suggesting sensitisation to titanium. Skin patch testing with dilute solutions of titanium salts gave negative results in all five patients. However, two of them had a positive skin test to a titanium-containing ointment.
1. Pain and pressure sensibility has been studied in the fibrous articular ligament and synovial membrane of the knee joint in normal human subjects and in patients subjected to arthrotomy under local anaesthesia. 2. The fibrous ligament was found to be a highly sensitive structure, containing many spots which give rise to sensations of pain or pressure when stimulated mechanically or chemically. Synovial membrane was found to be a relatively insensitive structure which only occasionally contains pain-sensitive spots. 3. Histological examination of articular capsule from the knee joints of normal and sympathectomised cats shows that articular ligaments have a rich nerve plexus and a variety of specialised and unspecialised nerve endings, most of which are somatic in origin. Synovial membrane contains a more delicate nerve network and also a variety of nerve endings, the majority of which are autonomic in origin. But a substantial number of somatic nerves enter the synovial membrane, some of which terminate in nerve loops, globular endings or simple unspecialised endings. 4. Histological examination of normal human articular capsule shows that its innervation closely resembles that of the cat, but no sympathectomised human material was examined. 5. The bearing of these findings on the symptomatology of joint disease is discussed briefly.
Aims. The diagnosis of periprosthetic joint infection (PJI) can be challenging as the symptoms are similar to other conditions, and the markers used for diagnosis have limited
Aims. This study aimed to evaluate rasterstereography of the spine as a diagnostic test for adolescent idiopathic soliosis (AIS), and to compare its results with those obtained using a scoliometer. Methods. Adolescents suspected of AIS and scheduled for radiographs were included. Rasterstereographic scoliosis angle (SA), maximal vertebral surface rotation (ROT), and angle of trunk rotation (ATR) with a scoliometer were evaluated. The area under the curve (AUC) from receiver operating characteristic (ROC) plots were used to describe the discriminative ability of the SA, ROT, and ATR for scoliosis, defined as a Cobb angle > 10°. Test characteristics (sensitivity and specificity) were reported for the best threshold identified using the Youden method. AUC of SA, ATR, and ROT were compared using the bootstrap test for two correlated ROC curves method. Results. Of 212 patients studied, 146 (69%) had an AIS. The AUC was 0.74 for scoliosis angle (threshold 12.5°,
Aims. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus. Methods. We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated its
Aims. To compare the cost-effectiveness of high-dose, dual-antibiotic cement versus single-antibiotic cement for the treatment of displaced intracapsular hip fractures in older adults. Methods. Using data from a multicentre randomized controlled trial (World Hip Trauma Evaluation 8 (WHiTE-8)) in the UK, a within-trial economic evaluation was conducted. Resource usage was measured over 120 days post randomization, and cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY), gained from the UK NHS and personal social services (PSS) perspective in the base-case analysis. Methodological uncertainty was addressed using
Aims. To assess the cost-effectiveness of a two-layer compression bandage versus a standard wool and crepe bandage following total knee arthroplasty, using patient-level data from the Knee Replacement Bandage Study (KReBS). Methods. A cost-utility analysis was undertaken alongside KReBS, a pragmatic, two-arm, open label, parallel-group, randomized controlled trial, in terms of the cost per quality-adjusted life year (QALY). Overall, 2,330 participants scheduled for total knee arthroplasty (TKA) were randomized to either a two-layer compression bandage or a standard wool and crepe bandage. Costs were estimated over a 12-month period from the UK NHS perspective, and health outcomes were reported as QALYs based on participants’ EuroQol five-dimesion five-level questionnaire responses. Multiple imputation was used to deal with missing data and
Aims. Histology is widely used for diagnosis of persistent infection during reimplantation in two-stage revision hip and knee arthroplasty, although data on its utility remain scarce. Therefore, this study aims to assess the predictive value of permanent sections at reimplantation in relation to reinfection risk, and to compare results of permanent and frozen sections. Methods. We retrospectively collected data from 226 patients (90 hips, 136 knees) with periprosthetic joint infection who underwent two-stage revision between August 2011 and September 2021, with a minimum follow-up of one year. Histology was assessed via the SLIM classification. First, we analyzed whether patients with positive permanent sections at reimplantation had higher reinfection rates than patients with negative histology. Further, we compared permanent and frozen section results, and assessed the influence of anatomical regions (knee versus hip), low- versus high-grade infections, as well as first revision versus multiple prior revisions on the histological result at reimplantation.
Aims. The early diagnosis of cauda equina syndrome (CES) is crucial for a favourable outcome. Several studies have reported the use of an ultrasound scan of the bladder as an adjunct to assess the minimum post-void residual volume of urine (mPVR). However, variable mPVR values have been proposed as a threshold without consensus on a value for predicting CES among patients with relevant symptoms and signs. The aim of this study was to perform a meta-analysis and systematic review of the published evidence to identify a threshold mPVR value which would provide the highest diagnostic accuracy in patients in whom the diagnosis of CES is suspected. Methods. The search strategy used electronic databases (PubMed, Medline, EMBASE, and AMED) for publications between January 1996 and November 2021. All studies that reported mPVR in patients in whom the diagnosis of CES was suspected, followed by MRI, were included. Results. A total of 2,115 studies were retrieved from the search. Seven fulfilled the inclusion criteria. These included 1,083 patients, with data available from 734 being available for meta-analysis. In 125 patients, CES was confirmed by MRI. The threshold value of mPVR reported in each study varied and could be categorized into 100 ml, 200 ml, 300 ml, and 500 ml. From the meta-analysis, 200 ml had the highest diagnostic accuracy, with 82%