Post-discharge surveillance of surgical site infection is necessary if accurate rates of infection following surgery are to be available. We undertook a prospective study of 376 knee and hip replacements in 366 patients in order to estimate the rate of orthopaedic surgical site infection in the community. The inpatient infection was 3.1% and the post-discharge infection rate was 2.1%. We concluded that the use of telephone interviews of patients to identify the group at highest risk of having a surgical site infection (those who think they have an infection) with rapid follow-up by a professional trained to diagnose infection according to agreed criteria is an effective method of identifying infection after discharge from hospital.
In wound irrigation, 1 mM ethylenediaminetetraacetic acid (EDTA) is more efficacious than normal saline (NS) in removing bacteria from a contaminated wound. However, the optimal EDTA concentration remains unknown for different animal wound models. The cell toxicity of different concentrations of EDTA dissolved in NS (EDTA-NS) was assessed by Cell Counting Kit-8 (CCK-8). Various concentrations of EDTA-NS irrigation solution were compared in three female Sprague-Dawley rat models: 1) a skin defect; 2) a bone exposed; and 3) a wound with an intra-articular implant. All three models were contaminated with Aims
Methods
Our aim was to perform a systematic review of the literature
to assess the incidence of post-operative epidural haematomas and
wound infections after one-, or two-level, non-complex, lumbar surgery
for degenerative disease in patients with, or without post-operative
wound drainage. Studies were identified from PubMed and EMBASE, up to and including
27 August 2015, for papers describing one- or two-level lumbar discectomy
and/or laminectomy for degenerative disease in adults which reported
any form of subcutaneous or subfascial drainage.Aims
Patients and Methods
Aims. Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture. Methods. This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36) intramedullary nail between 2016 to 2020. Patients were excluded if intramedullary fixation was combined with any other surgical procedure/fixation method. Outcomes included operating time, blood loss, fluoroscopic time, and complications. Fisher’s exact test and Mann-Whitney U test were used for categorical and continuous outcomes, respectively. Results. Patients receiving carbon nails as compared to those receiving titanium nails had higher blood loss (median 150 ml (interquartile range (IQR) 100 to 250) vs 100 ml (IQR 50 to 150); p = 0.042) and longer fluoroscopic time (median 150 seconds (IQR 114 to 182) vs 94 seconds (IQR 58 to 124); p = 0.001). Implant complications occurred in seven patients (19%) in the titanium group versus one patient (3%) in the carbon fibre group (p = 0.055). There were no notable differences between groups with regard to operating time,
The June 2023 Wrist & Hand Roundup360 looks at: Residual flexion deformity after scaphoid nonunion surgery: a seven-year follow-up study; The effectiveness of cognitive behavioural therapy for patients with concurrent hand and psychological disorders; Bite injuries to the hand and forearm: analysis of hospital stay, treatment, and costs; Outcomes of acute perilunate injuries - a systematic review; Abnormal MRI signal intensity of the triangular fibrocartilage complex in asymptomatic wrists; Patient comprehension of operative instructions with a paper handout versus a video: a prospective, randomized controlled trial; Can common hand surgeries be undertaken in the office setting?; The effect of corticosteroid injections on postoperative infections in trigger finger release.
Biofilm formation is intrinsic to prosthetic joint infection (PJI). In the current study, we evaluated the effects of silver-containing hydroxyapatite (Ag-HA) coating and vancomycin (VCM) on methicillin-resistant Pure titanium discs (Ti discs), Ti discs coated with HA (HA discs), and 3% Ag-HA discs developed using a thermal spraying were inoculated with MRSA suspensions containing a mean in vitro 4.3 (SD 0.8) x 106 or 43.0 (SD 8.4) x 105 colony-forming units (CFUs). Immediately after MRSA inoculation, sterile phosphate-buffered saline or VCM (20 µg/ml) was added, and the discs were incubated for 24 hours at 37°C. Viable cell counting, 3D confocal laser scanning microscopy with Airyscan, and scanning electron microscopy were then performed. HA discs and Ag HA discs were implanted subcutaneously in vivo in the dorsum of rats, and MRSA suspensions containing a mean in vivo 7.2 (SD 0.4) x 106 or 72.0 (SD 4.2) x 105 CFUs were inoculated on the discs. VCM was injected subcutaneously daily every 12 hours followed by viable cell counting.Aims
Methods
The aim of this study was to determine the impact of the severity of anaemia on postoperative complications following total hip arthroplasty (THA) and total knee arthroplasty (TKA). A retrospective cohort study was conducted using the American College of Surgeons National Quality Improvement Program (ACS-NSQIP) database. All patients who underwent primary TKA or THA between January 2012 and December 2017 were identified and stratified based upon hematocrit level. In this analysis, we defined anaemia as packed cell volume (Hct) < 36% for women and < 39% for men, and further stratified anaemia as mild anaemia (Hct 33% to 36% for women, Hct 33% to 39% for men), and moderate to severe (Hct < 33% for both men and women). Univariate and multivariate analyses were used to evaluate the incidence of multiple adverse events within 30 days of arthroplasty.Aims
Methods
In March 2012, an algorithm for the treatment
of intertrochanteric fractures of the hip was introduced in our academic
department of Orthopaedic Surgery. It included the use of specified
implants for particular patterns of fracture. In this cohort study,
102 consecutive patients presenting with an intertrochanteric fracture
were followed prospectively (post-algorithm group). Another 117
consecutive patients who had been treated immediately prior to the
implementation of the algorithm were identified retrospectively
as a control group (pre-algorithm group). The total cost of the
implants prior to implementation of the algorithm was $357 457 (mean:
$3055 (1947 to 4133)); compared with $255 120 (mean: $2501 (1052
to 4133)) after its implementation. There was a trend toward fewer complications
in patients who were treated using the algorithm (33% pre- The implementation of an evidence-based algorithm for the treatment
of intertrochanteric fractures reduced costs while maintaining quality
of care with a lower rate of complications and re-admissions. Cite this article:
The Department of Health and the Public Health Laboratory Service established the Nosocomial Infection National Surveillance Scheme in order to standardise the collection of information about infections acquired in hospital in the United Kingdom and provide national data with which hospitals could measure their own performance. The definition of superficial incisional infection (skin and subcutaneous tissue), set by the Center for Disease Control (CDC), should meet at least one of the defined criteria which would confirm the diagnosis and determine the need for specific treatment. We have assessed the interobserver reliability of the criteria for superficial incisional infection set by the CDC in our current practice. The incisional site of 50 patients who had an elective primary arthroplasty of the hip or knee was evaluated independently by two orthopaedic clinical research fellows and two orthopaedic ward sisters for the presence or absence of surgical-site infection. Interobserver reliability was assessed by comparison of the criteria for wound infection used by the four observers using kappa reliability coefficients. Our study demonstrated that some of the components of the current CDC criteria were unreliable and we recommend their revision.
National guidelines state that in patients undergoing operations the site of the procedure should be marked. In clinical practice the same marker is used repeatedly. We are not aware of any investigation regarding the theoretical risk of transferring organisms such as methicillin-resistant In an experimental setting, Penflex and Viomedex skin markers were tested 30 times each after contaminating them with a standard inoculum of MRSA. The survival of the organism on the tip of the markers was assessed by culture on MRSA-indicator nutrient agar plates at 0, 5, 15 and 60 minutes, 24 and 48 hours and at 1, 2, and 3 weeks after contamination. There was a significant difference between the markers, with the Penflex showing no survival of MRSA after 15 minutes whereas the Viomedex product continued to produce MRSA cultures for up to three weeks.
We compared patient-reported outcomes of the Kinemax fixed- and mobile-bearing total knee replacement in a multi-centre randomised controlled trial. Patients were randomised to the fixed- or the mobile-bearing prosthesis via a sealed envelope method after the bone cuts had been made in the operating theatre. Randomisation was stratified by centre and diagnosis. Patients were assessed pre-operatively and at eight to 12 weeks, one year and two years post-operatively. Validated questionnaires were used which included the Western Ontario MacMasters University, Short-Form 12, Mental Health Index-5, Knee Injury and Osteoarthritis Outcome Score for Knee-Related Quality of Life and Function in Sport and Recreation scales and a validated scale of satisfaction post-operatively. In total, 242 patients (250 knees) with a mean age of 68 years (40 to 80) were recruited from four NHS orthopaedic centres. Of these, 132 patients (54.5%) were women. No statistically significant differences could be identified in any of the patient-reported outcome scores between patients who received the fixed-bearing or the mobile-bearing knee up to two-years post-operatively.
Platelet-rich plasma is a new inductive therapy which is being increasingly used for the treatment of the complications of bone healing, such as infection and nonunion. The activator for platelet-rich plasma is a mixture of thrombin and calcium chloride which produces a platelet-rich gel. We analysed the antibacterial effect of platelet-rich gel Zones of inhibition produced by platelet-rich gel ranged between 6 mm and 24 mm (mean 9.83 mm) in diameter. Platelet-rich gel inhibited the growth of