Metal-on-metal resurfacing of the hip (MoMHR)
has enjoyed a resurgence in the last decade, but is now again in question
as a routine option for osteoarthritis of the hip. Proponents of
hip resurfacing suggest that its survival is superior to that of
conventional hip replacement (THR), and that hip resurfacing is
less invasive, is easier to revise than THR, and provides superior
functional outcomes. Our argument serves to illustrate that none
of these proposed advantages have been realised and new and unanticipated
serious complications, such as pseudotumors, have been associated
with the procedure. As such, we feel that the routine use of MoMHR
is not justified. Cite this article:
The June 2015 Knee Roundup360 looks at: Cruciate substituting
The anatomy and microstructure of the menisci
allow the effective distribution of load across the knee. Meniscectomy
alters the biomechanical environment and is a potent risk factor
for osteoarthritis. Despite a trend towards meniscus-preserving
surgery, many tears are irreparable, and many repairs fail. Meniscal allograft transplantation has principally been carried
out for pain in patients who have had a meniscectomy. Numerous case
series have reported a significant improvement in patient-reported
outcomes after surgery, but randomised controlled trials have not
been undertaken. It is scientifically plausible that meniscal allograft transplantation
is protective of cartilage, but this has not been established clinically
to date. Cite this article:
There is little evidence on the cost effectiveness
of different brands of hip prostheses. We compared lifetime cost effectiveness
of frequently used brands within types of prosthesis including cemented
(Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite
Plus Ogee), cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed)
and hybrid (Exeter V40 Trilogy, Exeter V40 Trident, and CPT Trilogy).
We used data from three linked English national databases to estimate
the lifetime risk of revision, quality-adjusted life years (QALYs)
and cost. For women with osteoarthritis aged 70 years, the Exeter V40 Elite
Plus Ogee had the lowest risk of revision (5.9% revision risk, 9.0
QALYs) and the CPT Trilogy had the highest QALYs (10.9% revision
risk, 9.3 QALYs). Compared with the Corail Pinnacle (9.3% revision
risk, 9.22 QALYs), the most commonly used brand, and assuming a
willingness-to-pay of £20 000 per QALY gain, the CPT Trilogy is
most cost effective, with an incremental net monetary benefit of £876.
Differences in cost effectiveness between the hybrid CPT Trilogy
and Exeter V40 Trident and the cementless Corail Pinnacle and Taperloc
Exceed were small, and a cautious interpretation is required, given
the limitations of the available information. However, it is unlikely that cemented brands are among the most
cost effective. Similar patterns of results were observed for men
and other ages. The gain in quality of life after total hip arthroplasty,
rather than the risk of revision, was the main driver of cost effectiveness. Cite this article:
The Swansea Morriston Achilles Rupture Treatment
(SMART) programme was introduced in 2008. This paper summarises
the outcome of this programme. Patients with a rupture of the Achilles
tendon treated in our unit follow a comprehensive management protocol
that includes a dedicated Achilles clinic, ultrasound examination,
the use of functional orthoses, early weight-bearing, an accelerated
exercise regime and guidelines for return to work and sport. The
choice of conservative or surgical treatment was based on ultrasound
findings. The rate of re-rupture, the outcome using the Achilles Tendon
Total Rupture Score (ATRS) and the Achilles Tendon Repair Score,
(AS), and the complications were recorded. An elementary cost analysis
was also performed. Between 2008 and 2014 a total of 273 patients presented with
an acute rupture 211 of whom were managed conservatively and 62
had surgical repair. There were three
re-ruptures (1.1%). There were 215 men and 58 women with a mean
age of 46.5 years (20 to 86). Functional outcome was satisfactory.
Mean ATRS and AS at four months was 53.0
( The SMART programme resulted in a low rate of re-rupture, a satisfactory
outcome, a reduced rate of surgical intervention and a reduction
in healthcare costs. Cite this article:
This study compared the clinical outcomes following
mini-open rotator cuff repair (MORCR) between early mobilisation
and usual care, involving initial immobilisation. In total, 189
patients with radiologically-confirmed full-thickness rotator cuff
tears underwent MORCR and were randomised to either early mobilisation
(n = 97) or standard rehabilitation (n = 92) groups. Patients were
assessed at six weeks and three, six, 12 and 24 months post-operatively.
Six-week range of movement comparisons demonstrated significantly
increased abduction (p = 0.002) and scapular plane elevation (p
= 0.006) in the early mobilisation group, an effect which was not
detectable at three months (p >
0.51) or afterwards. At 24 months
post-operatively, patients who performed pain-free, early active mobilisation
for activities of daily living showed no difference in clinical
outcomes from patients immobilised for six weeks following MORCR.
We suggest that the choice of rehabilitation regime following MORCR
may be left to the discretion of the patient and the treating surgeon. Cite this article:
This is the second of a series of reviews of registries. This review looks specifically at worldwide registry data that have been collected on knee arthroplasty, what we have learned from their reports, and what the limitations are as to what we currently know.
Frozen shoulder is a recognised complication
following simple arthroscopic shoulder procedures, but its exact incidence
has not been reported. Our aim was to analyse a single-surgeon series
of patients undergoing arthroscopic subacromial decompression (ASD;
group 1) or ASD in combination with arthroscopic acromioclavicular
joint (ACJ) excision (group 2), to establish the incidence of frozen
shoulder post-operatively. Our secondary aim was to identify associated
risk factors and to compare this cohort with a group of patients
with primary frozen shoulder. We undertook a retrospective analysis of 200 consecutive procedures
performed between August 2011 and November 2013. Group 1 included
96 procedures and group 2 104 procedures. Frozen shoulder was diagnosed
post-operatively using the British Elbow and Shoulder Society criteria.
A comparative group from the same institution involved 136 patients
undergoing arthroscopic capsular release for primary idiopathic
frozen shoulder. The incidence of frozen shoulder was 5.21% in group 1 and 5.71%
in group 2. Age between 46 and 60 years (p = 0.002) and a previous
idiopathic contralateral frozen shoulder (p <
0.001) were statistically
significant risk factors for the development of secondary frozen
shoulder. Comparison of baseline characteristics against the comparator groups
showed no statistically significant differences for age, gender,
diabetes and previous contralateral frozen shoulder. These results suggest that the risk of frozen shoulder following
simple arthroscopic procedures is just over 5%, with no increased
risk if the ACJ is also excised. Patients aged between 46 and 60
years and a previous history of frozen shoulder increase the relative
risk of secondary frozen shoulder by 7.8 (95% confidence interval
(CI) 2.1 to 28.3)and 18.5 (95% CI 7.4 to 46.3) respectively. Cite this article:
Surgical interventions consisting of internal
fixation (IF) or total hip replacement (THR) are required to restore
patient mobility after hip fractures. Conventionally, this decision
was based solely upon the degree of fracture displacement. However,
in the last ten years, there has been a move to incorporate patient
characteristics into the decision making process. Research demonstrating
that joint replacement renders superior functional results when compared
with IF, in the treatment of displaced femoral neck fractures, has
swayed the pendulum in favour of THR. However, a high risk of dislocation
has always been the concern. Fortunately, there are newer technologies
and alternative surgical approaches that can help reduce the risk
of dislocation. The authors propose an algorithm for the treatment
of femoral neck fractures: if minimally displaced, in the absence
of hip joint arthritis, IF should be performed; if arthritis is
present, or the fracture is displaced, then THR is preferred. Cite this article:
A national, multi-centre study was designed in
which a questionnaire quantifying the degree of patient satisfaction
and residual symptoms in patients following total knee replacement
(TKR) was administered by an independent, blinded third party survey
centre. A total of 90% of patients reported satisfaction with the
overall functioning of their knee, but 66% felt their knee to be
‘normal’, with the reported incidence of residual symptoms and functional
problems ranging from 33% to 54%. Female patients and patients from
low-income households had increased odds of reporting dissatisfaction.
Neither the use of contemporary implant designs (gender-specific,
high-flex, rotating platform) or custom cutting guides (CCG) with
a neutral mechanical axis target improved patient-perceived outcomes.
However, use of a CCG to perform a so-called kinematically aligned
TKR showed a trend towards more patients reporting their knee to
feel ‘normal’ when compared with a so called mechanically aligned
TKR This data shows a degree of dissatisfaction and residual symptoms
following TKR, and that several recent modifications in implant
design and surgical technique have not improved the current situation. Cite this article:
We evaluated the impact of pre-coating the tibial
component with polymethylmethacrylate (PMMA) on implant survival
in a cohort of 16 548 primary NexGen total knee replacements (TKRs)
in 14 113 patients. In 13 835 TKRs a pre-coated tray was used while
in 2713 TKRs the non-pre-coated version of the same tray was used.
All the TKRs were performed between 2001 and 2009 and were cemented.
TKRs implanted with a pre-coated tibial component had a lower cumulative
survival than those with a non-pre-coated tibial component (p =
0.01). After adjusting for diagnosis, age, gender, body mass index,
American Society of Anesthesiologists grade, femoral coupling design, surgeon
volume and hospital volume, pre-coating was an independent risk
factor for all-cause aseptic revision (hazard ratio 2.75, p = 0.006).
Revision for aseptic loosening was uncommon for both pre-coated
and non-pre-coated trays (rates of 0.12% and 0%, respectively).
Pre-coating with PMMA does not appear to be protective of revision
for this tibial tray design at short-term follow-up. Cite this article:
There is conflicting evidence about the functional
outcome and rate of satisfaction of super-elderly patients (≥ 80 years
of age) after carpal tunnel decompression. We compiled outcome data for 756 patients who underwent a carpal
tunnel decompression over an eight-year study period, 97 of whom
were super-elderly, and 659 patients who formed a younger control
group (<
80 years old). There was no significant difference between
the super-elderly patients and the younger control group in terms
of functional outcome according to the mean (0 to 100) QuickDASH
score (adjusted mean difference at one year 1.8; 95% confidence
interval (CI) -3.4 to 7.0) and satisfaction rate (odds ratio (OR)
0.78; 95% CI 0.34 to 1.58). Super-elderly patients were, however,
more likely to have thenar muscle atrophy at presentation (OR 9.2,
95% CI 5.8 to 14.6). When nerve conduction studies were obtained,
super-elderly patients were more likely to have a severe conduction deficit
(OR 12.4, 95% CI 3.0 to 51.3). Super-elderly patients report functional outcome and satisfaction
rates equal to those of their younger counterparts. They are more
likely to have thenar muscle atrophy and a severe nerve conduction
deficit at presentation, and may therefore warrant earlier decompression. Cite this article:
An atypical femoral fracture (AFF), with a transverse
fracture radiologically through the lateral cortex is a rare but serious
condition. In order to improve our ability to identify patients
with this condition, we retrospectively surveyed all subtrochanteric,
peri-implant and diaphyseal femoral fractures in patients aged ≥ 65
years who underwent surgical treatment at our hospital between 2004
and 2011. We describe the incidence of atypical fractures and their characteristics,
with observational data including a review of the hospital and general
practitioner records. Clinical outcomes were evaluated using the
Harris hip score (HHS) and the timed up-and-go (TUG) test. Atypical fractures only occurred in women with an incidence of
9.8 per 100 000 person-years. The incidence in those who were treated
with bisphosphonates was 79.0 per 100 000 person-years; eight of
17 fractures occurred around metal implants. There was a high incidence
of delayed union and revision surgery. A total of nine patients (ten
AFFs) were available for review at a mean follow-up of 36.5 months
(10 to 104). The clinical outcome was poor with a mean HHS of 58.9
(95% CI 47.4 to 70.4) and a mean TUG test of 25.7 s (95% CI 12.7
to 38.8). The delay in diagnosis and treatment of AFF may result from a
lack of knowledge of this condition. Cite this article:
We present the extended follow-up (≥ 20 years)
of a series of fully hydroxyapatite-coated femoral components used in
72 primary total hip replacements (THRs). Earlier results of this
cohort have been previously published. All procedures were performed
between 1986 and 1991. The series involved 45 women and 15 men with
12 bilateral procedures. Their mean age at the time of surgery was
60 years (46 to 80) and the mean duration of follow-up was 22.5
years (20 to 25). At final follow-up, the mean Merle d’Aubigné and
Postel hip scores were 5.5 (4.5 to 6), 3.8 (3.5 to 5) and 3.3 (3.0
to 5.0) for pain, mobility and function, respectively. Of the patients
92% were very satisfied at the time of final follow-up. There were seven revisions: six of the acetabular component for
aseptic loosening and one of both the stem and the acetabular component
for loosening due to deep infection. The survival of this prosthesis
at 22.5 years with revision for any reason as the endpoint was 91.7%
(95% confidence interval (CI) 84 to 99). Survival with aseptic loosening
of the stem as the endpoint was 100% (95% CI 90 to 100). This prosthesis provides pain relief in the long term. Survival
of this component is comparable to the best results for primary
THR with any means of fixation. Cite this article:
Ceramic-on-metal (CoM) is a relatively new bearing
combination for total hip arthroplasty (THA) with few reported outcomes.
A total of 287 CoM THAs were carried out in 271 patients (mean age
55.6 years (20 to 77), 150 THAs in female patients, 137 in male)
under the care of a single surgeon between October 2007 and October
2009. With the issues surrounding metal-on-metal bearings the decision
was taken to review these patients between March and November 2011,
at a mean follow-up of 34 months (23 to 45) and to record pain,
outcome scores, radiological analysis and blood ion levels. The
mean Oxford Hip Score was 19.2 (12 to 53), 254 patients with 268
hips (95%) had mild/very mild/no pain, the mean angle of inclination
of the acetabular component was 44.8o (28o to
63o), 82 stems (29%) had evidence of radiolucent lines
of >
1 mm in at least one Gruen zone and the median levels of cobalt
and chromium ions in the blood were 0.83 μg/L (0.24 μg/L to 27.56 μg/L)
and 0.78 μg/L (0.21 μg/L to 8.84 μg/L), respectively. The five-year
survival rate is 96.9% (95% confidence interval 94.7% to 99%). Due to the presence of radiolucent lines and the higher than
expected levels of metal ions in the blood, we would not recommend
the use of CoM THA without further long-term follow-up. We plan
to monitor all these patients regularly. Cite this article:
This study describes the epidemiology and outcome
of 637 proximal humeral fractures in 629 elderly (≥ 65 years old) patients.
Most were either minimally displaced (n = 278, 44%) or two-part
fractures (n = 250, 39%) that predominantly occurred in women (n
= 525, 82%) after a simple fall (n = 604, 95%), who lived independently
in their own home (n = 560, 88%), and one in ten sustained a concomitant
fracture (n = 76, 11.9%). The rate of mortality at one year was
10%, with the only independent predictor of survival being whether
the patient lived in their own home (p = 0.025). Many factors associated
with the patient’s social independence significantly influenced
the age and gender adjusted Constant score one year after the fracture.
More than a quarter of the patients had a poor functional outcome,
with those patients not living in their own home (p = 0.04), participating
in recreational activities (p = 0.01), able to perform their own
shopping (p <
0.001), or able to dress themselves (p = 0.02)
being at a significantly increased risk of a poor outcome, which
was independent of the severity of the fracture (p = 0.001). A poor functional outcome after a proximal humeral fracture is
not independently influenced by age in the elderly, and factors
associated with social independence are more predictive of outcome. Cite this article:
Total hip replacement causes a short-term increase
in the risk of mortality. It is important to quantify this and to identify
modifiable risk factors so that the risk of post-operative mortality
can be minimised. We performed a systematic review and critical
evaluation of the current literature on the topic. We identified
32 studies published over the last 10 years which provide either
30-day or 90-day mortality data. We estimate the pooled incidence
of mortality during the first 30 and 90 days following hip replacement
to be 0.30% (95% CI 0.22 to 0.38) and 0.65% (95% CI 0.50 to 0.81),
respectively. We found strong evidence of a temporal trend towards
reducing mortality rates despite increasingly co-morbid patients.
The risk factors for early mortality most commonly identified are
increasing age, male gender and co-morbid conditions, particularly
cardiovascular disease. Cardiovascular complications appear to have
overtaken fatal pulmonary emboli as the leading cause of death after
hip replacement. Cite this article:
Isolated patellofemoral arthritis is a common
condition and there are varying opinions on the most effective treatments.
Non-operative and operative treatments have failed to demonstrate
effective long-term treatment for those in an advanced stage of
the condition. Newer designs and increased technology in patellofemoral replacement
(PFR) have produced more consistent outcomes. This has led to a
renewed enthusiasm for this procedure. Newer PFR prostheses have
addressed the patellar maltracking issues plaguing some of the older designs.
Short-term results with contemporary prostheses and new technology
are described here. Cite this article:
The increasing need for total hip replacement
(THR) in an ageing population will inevitably generate a larger number
of revision procedures. The difficulties encountered in dealing
with the bone deficient acetabulum are amongst the greatest challenges
in hip surgery. The failed acetabular component requires reconstruction
to restore the hip centre and improve joint biomechanics. Impaction
bone grafting is successful in achieving acetabular reconstruction
using both cemented and cementless techniques. Bone graft incorporation
restores bone stock whilst providing good component stability. We
provide a summary of the evidence and current literature regarding impaction
bone grafting using both cemented and cementless techniques in revision
THR. Cite this article:
In this paper, we will consider the current role
of metal-on-metal bearings by looking at three subtypes of MoM hip
arthroplasty separately: Hip resurfacing, large head (>
36 mm) MoM
THA and MoM THA with traditional femoral head sizes.