Advertisement for orthosearch.org.uk
Results 181 - 184 of 184
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 916 - 920
1 Jul 2005
Ebied A Hoad-Reddick DA Raut V

A reduced femoral offset in total hip replacement has been thought to be disadvantageous. We reviewed the results of 54 consecutive primary total hip replacements in 49 patients (mean age of 68 years) performed between August 1990 and December 1994, with a mean follow-up of 8.8 years (sd 2.1). The mean pre-operative femoral offset for these hips was 41 mm (sd 7.4). All patients received a low-offset Charnley stem and a polyethylene cup inserted by a single surgeon.

At their latest follow-up, surviving patients had a significant improvement in the performance of their hip. Three had undergone revision, one each for deep infection, recurrent dislocation and late pain with subluxation. No hips had been revised, or were at risk of revision, for aseptic loosening. The mean annual linear rate of wear was 0.2 mm (sd 0.08) for the whole group. There was no correlation between the pre-operative femoral offset and the post-operative rate of wear. Our survivorship estimate was 91% when revision for any reason was taken as an end-point, but 100% if aseptic loosening was considered as the end-point. Our study demonstrates that a low-offset femoral stem can produce good, medium-term results.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 508 - 512
1 Apr 2005
Lafuente J Casey ATH Petzold A Brew S

We present data relating to the Bryan disc arthroplasty for the treatment of cervical spondylosis in 46 patients.

Patients with either radiculopathy or myelopathy had a cervical discectomy followed by implantation of a cervical disc prosthesis. Patients were reviewed at six weeks, six months and one year and assessment included three outcome measures, a visual analogue scale (VAS), the short form 36 (SF-36) and the neck disability index (NDI). The results were categorised according to a modification of Odom’s criteria. Radiological evaluation, by an independent radiologist, sought evidence of movement, stability and subsidence of the prosthesis.

A highly significant difference was found for all three outcome measurements, comparing the pre-operative with the post-operative values: VAS (Z = 6.42, p < 0.0001), SF-36 (mental component) (Z = −5.02, p < 0.0001), SF-36 (physical component) (Z = −5.00, p < 0.0001) and NDI (Z = 7.03, p < 0.0001). The Bryan cervical disc prosthesis seems reliable and safe in the treatment of patients with cervical spondylosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss.

We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1426 - 1433
1 Oct 2005
Kobayashi T Watanabe H Yanagawa T Tsutsumi S Kayakabe M Shinozaki T Higuchi H Takagishi K

Human bone-marrow mesenchymal stem cells have an important role in the repair of musculoskeletal tissues by migrating from the bone marrow into the injured site and undergoing differentiation. We investigated the use of autologous human serum as a substitute for fetal bovine serum in the ex vivo expansion medium to avoid the transmission of dangerous transfectants during clinical reconstruction procedures.

Autologous human serum was as effective in stimulating growth of bone-marrow stem cells as fetal bovine serum. Furthermore, medium supplemented with autologous human serum was more effective in promoting motility than medium with fetal bovine serum in all cases. Addition of B-fibroblast growth factor to medium with human serum stimulated growth, but not motility. Our results suggest that autologous human serum may provide sufficient ex vivo expansion of human bone-marrow mesenchymal stem cells possessing multidifferentiation potential and may be better than fetal bovine serum in preserving high motility.