We report patient-reported outcomes and complications
associated with contemporary periacetabular osteotomy (PAO) surgery
in treating symptomatic acetabular dysplasia and compare these outcomes
with total hip arthroplasty (THA) in patients with similar demographic
details. Two consecutive cohorts included patients between aged
18 to 40 years who had undergone either PAO (100 hips; 24 male,
76 female) or THA (55 hips; 18 male, 37 female). At a mean follow-up
of 5.9 years (2 to 13), there was significant improvement in the
modified Harris hip pain (p <
0.001, PAO and p <
0.001, THA),
function (p <
0.001, PAO and p = 0.001, THA), and total scores
(p <
0.001, PAO and p <
0.001, THA) within each cohort. There
were no significant differences in the clinical outcome scores between
the groups. Complication rates were low and similar in each cohort
(p = 0.68). Similar to THA, contemporary PAO surgery is a clinically
effective procedure that improves function and activity levels,
provides pain relief and is associated with an acceptable complication
rate. Cite this article:
We report an audit of 208 patients with a mean age of 39 years (16 to 65) attending the Orthopaedic Assessment Unit at the Wellington Hospital between January 2006 and December 2007 with an injury of the tendo Achillis requiring immobilisation in a cast. Information on assessment of venous thromboembolism (VTE) risk, prophylactic measures and VTE events for all patients was obtained from the medical records. A VTE risk factor was documented in the records of three (1%) patients. One of the 208 patients received aspirin prophylaxis; none received low molecular weight heparin. In all, 13 patients (6.3%, 95% confidence interval 3.4 to 10.5) developed symptomatic VTE during immobilisation in a cast, including six with a distal deep-vein thrombosis (DVT), four with a proximal DVT, and three with a confirmed pulmonary embolus. This incidence of symptomatic VTE is similar to that reported following elective hip replacement. We propose that consideration is given to VTE prophylaxis during prolonged immobilisation of the lower limbs in a cast, to ensure that the same level of protection is provided as for patients undergoing elective hip replacement.
The February 2015 Children’s orthopaedics Roundup360 looks at: Hip dislocation in children with CTEV: two decades of experience; Population-based prevention of DDH in cerebral palsy: 20 years’ experience; Shoulder derotation in congenital plexus palsy; Back pain in the paediatric population: could MRI be the answer?; Intercondylar fracture of the humerus in children; The Dunn osteotomy in SUFE; Radiocapitellar line a myth!; Do ‘flatfooted’ children suffer?
Severe hallux valgus deformity is conventionally
treated with proximal metatarsal osteotomy. Distal metatarsal osteotomy
with an associated soft-tissue procedure can also be used in moderate
to severe deformity. We compared the clinical and radiological outcomes
of proximal and distal chevron osteotomy in severe hallux valgus deformity
with a soft-tissue release in both. A total of 110 consecutive female
patients (110 feet) were included in a prospective randomised controlled
study. A total of 56 patients underwent a proximal procedure and
54 a distal operation. The mean follow-up was 39 months (24 to 54)
in the proximal group and 38 months (24 to 52) in the distal group.
At follow-up the hallux valgus angle, intermetatarsal angle, distal
metatarsal articular angle, tibial sesamoid position, American Orthopaedic
Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal
score, patient satisfaction level, and complications were similar
in each group. Both methods showed significant post-operative improvement
and high levels of patient satisfaction. Our results suggest that
the distal chevron osteotomy with an associated distal soft-tissue
procedure provides a satisfactory method for correcting severe hallux
valgus deformity. Cite this article:
We present an economic evaluation using data
from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare
the relative cost effectiveness of percutaneous Kirschner wire (K-wire)
fixation and volar locking-plate fixation for patients with dorsally-displaced
fractures of the distal radius. The cost effectiveness analysis (cost per quality-adjusted life
year; QALY) was derived from a multi-centre, two-arm, parallel group,
assessor-blind, randomised controlled trial which took place in
18 trauma centres in the United Kingdom. Data from 460 patients
were available for analysis, which includes both a National Health
Service cost perspective including costs of surgery, implants and
healthcare resource use over a 12-month period after surgery, and
a societal perspective, which includes the cost of time off work
and the need for additional private care. There was only a small difference in QALYs gained for patients
treated with locking-plate fixation over those treated with K-wires.
At a mean additional cost of £714 (95% confidence interval 588 to
865) per patient, locking-plate fixation presented an incremental
cost effectiveness ratio (ICER) of £89 322 per QALY within the first
12 months of treatment. Sensitivity analyses were undertaken to
assess the ICER of locking-plate fixation compared with K-wires.
These were greater than £30 000. Compared with locking-plate fixation, K-wire fixation is a ‘cost
saving’ intervention, with similar health benefits. Cite this article:
In a global environment of rising costs and limited funds, robotic and computer-assisted orthopaedic technologies could provide the means to drive a necessary revolution in arthroplasty productivity. Robots have been used to operate on humans for 20 years, but the adoption of the technology has lagged behind that of the manufacturing industry. The use of robots in surgery should enable cost savings by reducing instrumentation and inventories, and improving accuracy. Despite these benefits, the orthopaedic community has been resistant to change. If the ergonomics and economics are right, robotic technology just might transform the provision of joint replacement.
Dysplasia of the hip, hypotonia, osteopenia,
ligamentous laxity, and mental retardation increase the complexity
of performing and managing patients with Down syndrome who require
total hip replacement (THR). We identified 14 patients (six males,
eight females, 21 hips) with Down syndrome and degenerative disease
of the hip who underwent THR, with a minimum follow-up of two years
from 1969 to 2009. In seven patients, bilateral THRs were performed
while the rest had unilateral THRs. The mean clinical follow-up
was 5.8 years (standard deviation ( Cite this article:
Moderate to severe hallux valgus is conventionally
treated by proximal metatarsal osteotomy. Several recent studies
have shown that the indications for distal metatarsal osteotomy
with a distal soft-tissue procedure could be extended to include
moderate to severe hallux valgus. The purpose of this prospective randomised controlled trial was
to compare the outcome of proximal and distal Chevron osteotomy
in patients undergoing simultaneous bilateral correction of moderate
to severe hallux valgus. The original study cohort consisted of 50 female patients (100
feet). Of these, four (8 feet) were excluded for lack of adequate
follow-up, leaving 46 female patients (92 feet) in the study. The
mean age of the patients was 53.8 years (30.1 to 62.1) and the mean
duration of follow-up 40.2 months (24.1 to 80.5). After randomisation,
patients underwent a proximal Chevron osteotomy on one foot and
a distal Chevron osteotomy on the other. At follow-up, the American Orthopedic Foot and Ankle Society
(AOFAS) hallux metatarsophalangeal interphalangeal (MTP-IP) score,
patient satisfaction, post-operative complications, hallux valgus
angle, first-second intermetatarsal angle, and tibial sesamoid position
were similar in each group. Both procedures gave similar good clinical
and radiological outcomes. This study suggests that distal Chevron osteotomy with a distal
soft-tissue procedure is as effective and reliable a means of correcting
moderate to severe hallux valgus as proximal Chevron osteotomy with
a distal soft-tissue procedure. Cite this article:
The use of robots in orthopaedic surgery is an
emerging field that is gaining momentum. It has the potential for significant
improvements in surgical planning, accuracy of component implantation
and patient safety. Advocates of robot-assisted systems describe
better patient outcomes through improved pre-operative planning
and enhanced execution of surgery. However, costs, limited availability,
a lack of evidence regarding the efficiency and safety of such systems
and an absence of long-term high-impact studies have restricted
the widespread implementation of these systems. We have reviewed
the literature on the efficacy, safety and current understanding of
the use of robotics in orthopaedics. Cite this article:
We report the clinical and radiographic outcomes
of 208 consecutive femoral revision arthroplasties performed in 202
patients (119 women, 83 men) between March 1991 and December 2007
using the X-change Femoral Revision System, fresh-frozen morcellised
allograft and a cemented polished Exeter stem. All patients were
followed prospectively. The mean age of the patients at revision
was 65 years (30 to 86). At final review in December 2013 a total
of 130 patients with 135 reconstructions (64.9%) were alive and
had a non re-revised femoral component after a mean follow-up of
10.6 years (4.7 to 20.9). One patient was lost to follow-up at six
years, and their data were included up to this point.
Re-operation for any reason was performed in 33 hips (15.9%), in
13 of which the femoral component was re-revised (6.3%). The mean
pre-operative Harris hip score was 52 (19 to 95) (n = 73) and improved
to 80 (22 to 100) (n = 161) by the last follow-up. Kaplan–Meier
survival with femoral re-revision for any reason as the endpoint
was 94.9% (95% confidence intervals (CI) 90.2 to 97.4) at ten years;
with femoral re-revision for aseptic loosening as the endpoint it was
99.4% (95% CI 95.7 to 99.9); with femoral re-operation for any reason
as the endpoint it was 84.5% (95% CI 78.3 to 89.1); and with subsidence ≥ 5
mm it was 87.3% (95% CI 80.5 to 91.8). Femoral revision with the
use of impaction allograft bone grafting and a cemented polished
stem results in a satisfying survival rate at a mean of ten years’ follow-up. Cite this article:
Revision total hip replacement (THR) for young
patients is challenging because of technical complexity and the potential
need for subsequent further revisions. We have assessed the survivorship,
functional outcome and complications of this procedure in patients
aged <
50 years through a large longitudinal series with consistent treatment
algorithms. Of 132 consecutive patients (181 hips) who underwent
revision THR, 102 patients (151 hips) with a mean age of 43 years
(22 to 50) were reviewed at a mean follow-up of 11 years (2 to 26)
post-operatively. We attempted to restore bone stock with allograft
where indicated. Using further revision for any reason as an end point,
the survival of the acetabular component was 71% ( This overall perspective on the mid- to long-term results is
valuable when advising young patients on the prospects of revision
surgery at the time of primary replacement. Cite this article:
The aim of this study was to investigate the
incidence of dysplasia in the ‘normal’ contralateral hip in patients
with unilateral developmental dislocation of the hip (DDH) and to
evaluate the long-term prognosis of such hips. A total of 48 patients
(40 girls and eight boys) were treated for late-detected unilateral
DDH between 1958 and 1962. After preliminary skin traction, closed
reduction was achieved at a mean age of 17.8 months (4 to 65) in
all except one patient who needed open reduction. In 25 patients
early derotation femoral osteotomy of the contralateral hip had been
undertaken within three years of reduction, and later surgery in
ten patients. Radiographs taken during childhood and adulthood were
reviewed. The mean age of the patients was 50.9 years (43 to 55)
at the time of the latest radiological review. In all, eight patients (17%) developed dysplasia of the contralateral
hip, defined as a centre-edge (CE) angle <
20° during childhood
or at skeletal maturity. Six of these patients underwent surgery
to improve cover of the femoral head; the dysplasia improved in
two after varus femoral osteotomy and in two after an acetabular
shelf operation. During long-term follow-up the dysplasia deteriorated
to subluxation in two patients (CE angles 4° and 5°, respectively)
who both developed osteoarthritis (OA), and one of these underwent
total hip replacement at the age of 49 years. In conclusion, the long-term prognosis for the contralateral
hip was relatively good, as OA occurred in only two hips (4%) at
a mean follow-up of 50 years. Regular review of the ‘normal’ side
is indicated, and corrective surgery should be undertaken in those
who develop subluxation. Cite this article:
Dislocation is a common and well-studied complication after total hip replacement. However, subluxation, which we define as a clinically recognised episode of incomplete movement of the femoral head outside the acetabulum with spontaneous reduction, has not been studied previously. Out of a total of 2521 hip replacements performed over 12 years by one surgeon, 30 patients experienced subluxations which occurred in 31 arthroplasties. Data were collected prospectively with a minimum follow-up of two years. Subluxation occurred significantly more frequently after revision than after primary hip replacement, and resolved in 19 of 31 cases (61.3%). In six of the 31 hips (19.4%) the patient subsequently dislocated the affected hip, and in six hips (19.4%) intermittent subluxation continued. Four patients had a revision operation for instability, three for recurrent dislocation and one for recurrent subluxation. Clinical and radiological comparisons with a matched group of stable total hips showed no correlation with demographic or radiological parameters. Patients with subluxing hips reported significantly more concern that their hip would dislocate, more often changed their behaviour to prevent instability and had lower postoperative Harris hip scores than patients with stable replacements.
The December 2013 Children’s orthopaedics Roundup360 looks at: Long term-changes in hip morphology following osteotomy; Arthrogrypotic wrist contractures are surgically amenable; Paediatric femoral lengthening over a nail; Current management of paediatric supracondylar fractures; MRI perfusion index predictive of Perthes’ progression; Abduction bracing effective in residual acetabular deformity; Hurler syndrome in the spotlight; and the Pavlik works for femoral fractures too!
Down’s syndrome is associated with a number of
musculoskeletal abnormalities, some of which predispose patients
to early symptomatic arthritis of the hip. The purpose of the present
study was to review the general and hip-specific factors potentially
compromising total hip replacement (THR) in patients with Down’s
syndrome, as well as to summarise both the surgical techniques that
may anticipate the potential adverse impact of these factors and
the clinical results reported to date. A search of the literature
was performed, and the findings further informed by the authors’
clinical experience, as well as that of the hip replacement in Down
Syndrome study group. The general factors identified include a high
incidence of ligamentous laxity, as well as associated muscle hypotonia
and gait abnormalities. Hip-specific factors include: a high incidence
of hip dysplasia, as well as a number of other acetabular, femoral
and combined femoroacetabular anatomical variations. Four studies
encompassing 42 hips, which reported the clinical outcomes of THR
in patients with Down’s syndrome, were identified. All patients
were successfully treated with standard acetabular and femoral components.
The use of supplementary acetabular screw fixation to enhance component
stability was frequently reported. The use of constrained liners
to treat intra-operative instability occurred in eight hips. Survival
rates of between 81% and 100% at a mean follow-up of 105 months
(6 to 292) are encouraging. Overall, while THR in patients with
Down’s syndrome does present some unique challenges, the overall
clinical results are good, providing these patients with reliable
pain relief and good function. Cite this article:
The August 2013 Children’s orthopaedics Roundup360 looks at: a multilevel approach to equinus gait; whether screening leads to needless intervention; salvage of subcapital slipped epiphysis; growing prostheses for children’s oncology; flexible nailing revisited; ultrasound and the pink pulseless hand; and slipping forearm fractures.