We have investigated whether improvements in design have altered the outcome for patients undergoing endoprosthetic replacement of the proximal tibia following resection of a tumour. Survival of the implant and ‘servicing’ procedures have been documented using a prospective database. A total of 194 patients underwent a proximal tibial replacement, with 95 having a fixed-hinge design and 99 a rotating-hinge with a hydroxyapatite collar; their median age was 21.5 years (10 to 74). At a mean follow-up of 14.7 years (5 to 29), 115 patients remain alive. The risk of revision for any reason in the fixed-hinge group was 32% at five years, 61% at ten years and 75% at 15 and 20 years, and in the rotating-hinge group 12% at five years, 25% at ten years and 30% at 15 years. Aseptic loosening was the most common reason for revision in the fixed-hinge knees, fracture of the implant in the early design of rotating hinges and infection in the current version. The risk of revision for aseptic loosening in the fixed-hinge knees was 46% at ten years. This was reduced to 3% in the rotating-hinge knee with a hydroxyapatite collar. The cemented, rotating hinge design currently offers the best chance of long-term survival of the prosthesis.
Coronal plane fractures of the posterior femoral
condyle, also known as Hoffa fractures, are rare. Lateral fractures are
three times more common than medial fractures, although the reason
for this is not clear. The exact mechanism of injury is likely to
be a vertical shear force on the posterior femoral condyle with
varying degrees of knee flexion. These fractures are commonly associated
with high-energy trauma and are a diagnostic and surgical challenge. Hoffa
fractures are often associated with inter- or supracondylar distal
femoral fractures and CT scans are useful in delineating the coronal
shear component, which can easily be missed. There are few recommendations
in the literature regarding the surgical approach and methods of
fixation that may be used for this injury. Non-operative treatment
has been associated with poor outcomes. The goals of treatment are
anatomical reduction of the articular surface with rigid, stable
fixation to allow early mobilisation in order to restore function.
A surgical approach that allows access to the posterior aspect of
the femoral condyle is described and the use of postero-anterior
lag screws with or without an additional buttress plate for fixation
of these difficult fractures. Cite this article:
Achieving deep flexion after total knee replacement remains a challenge. In this study we compared the soft-tissue tension and tibiofemoral force in a mobile-bearing posterior cruciate ligament-sacrificing total knee replacement, using equal flexion and extension gaps, and with the gaps increased by 2 mm each. The tests were conducted during passive movement in five cadaver knees, and measurements of strain were made simultaneously in the collateral ligaments. The tibiofemoral force was measured using a customised mini-force plate in the tibial tray. Measurements of collateral ligament strain were not very sensitive to changes in the gap ratio, but tibiofemoral force measurements were. Tibiofemoral force was decreased by a mean of 40% (
Intra-operative, peri-articular injection of
local anaesthesia is an increasingly popular way of controlling
pain following total knee replacement. The evidence from this study suggests that it is safe to use
peri-articular injection in combination with auto-transfusion of
blood from peri-articular drains during knee replacement surgery.
Neurogenic heterotopic ossification (NHO) is
a disorder of aberrant bone formation affecting one in five patients sustaining
a spinal cord injury or traumatic brain injury. Ectopic bone forms
around joints in characteristic patterns, causing pain and limiting
movement especially around the hip and elbow. Clinical sequelae
of neurogenic heterotopic ossification include urinary tract infection,
pressure injuries, pneumonia and poor hygiene, making early diagnosis
and treatment clinically compelling. However, diagnosis remains
difficult with more investigation needed. Our pathophysiological
understanding stems from mechanisms of basic bone formation enhanced
by evidence of systemic influences from circulating humor factors
and perhaps neurological ones. This increasing understanding guides
our implementation of current prophylaxis and treatment including
the use of non-steroidal anti-inflammatory drugs, bisphosphonates,
radiation therapy and surgery and, importantly, should direct future, more
effective ones.
Abnormal sagittal kinematics after total knee replacement (TKR) can adversely affect functional outcome. Two important determinants of knee kinematics are component geometry and the presence or absence of a posterior-stabilising mechanism (cam-post). We investigated the influence of these variables by comparing the kinematics of a TKR with a polyradial femur with a single radius design, both with and without a cam-post mechanism. We assessed 55 patients, subdivided into four groups, who had undergone a TKR one year earlier by using an established fluoroscopy protocol in order to examine their kinematics
Patients with skeletal dysplasia are prone to
developing advanced osteoarthritis of the knee requiring total knee replacement
(TKR) at a younger age than the general population. TKR in this
unique group of patients is a technically demanding procedure owing
to the deformity, flexion contracture, generalised hypotonia and ligamentous
laxity. We retrospectively reviewed the outcome of 11 TKRs performed
in eight patients with skeletal dysplasia at our institution using
the Stanmore Modular Individualised Lower Extremity System (SMILES)
custom-made rotating-hinge TKR. There were three men and five women
with mean age of 57 years (41 to 79). Patients were followed clinically
and radiologically for a mean of seven years (3 to 11.5). The mean
Knee Society clinical and function scores improved from 24 (14 to
36) and 20 (5 to 40) pre-operatively, respectively, to 68 (28 to
80) and 50 (22 to 74), respectively, at final follow-up. Four complications
were recorded, including a patellar fracture following a fall, a
tibial peri-prosthetic fracture, persistent anterior knee pain,
and aseptic loosening of a femoral component requiring revision.
Our results demonstrate that custom primary rotating-hinge TKR in
patients with skeletal dysplasia is effective at relieving pain,
with a satisfactory range of movement and improved function. It compensates
for bony deformity and ligament deficiency and reduces the likelihood
of corrective osteotomy. Patellofemoral joint complications are
frequent and functional outcome is worse than with primary TKR in
the general population.
This review considers the surgical treatment
of displaced fractures involving the knee in elderly, osteoporotic patients.
The goals of treatment include pain control, early mobilisation,
avoidance of complications and minimising the need for further surgery.
Open reduction and internal fixation (ORIF) frequently results in
loss of reduction, which can result in post-traumatic arthritis
and the occasional conversion to total knee replacement (TKR). TKR
after failed internal fixation is challenging, with modest functional
outcomes and high complication rates. TKR undertaken as treatment
of the initial fracture has better results to late TKR, but does
not match the outcome of primary TKR without complications. Given
the relatively infrequent need for late TKR following failed fixation,
ORIF is the preferred management for most cases. Early TKR can be
considered for those patients with pre-existing arthritis, bicondylar
femoral fractures, those who would be unable to comply with weight-bearing restrictions,
or where a single definitive procedure is required.
We retrospectively reviewed the records of 1150
computer-assisted total knee replacements and analysed the clinical
and radiological outcomes of 45 knees that had arthritis with a
pre-operative recurvatum deformity. The mean pre-operative hyperextension
deformity of 11° (6° to 15°), as measured by navigation at the start
of the operation, improved to a mean flexion deformity of 3.1° (0°
to 7°) post-operatively. A total of 41 knees (91%) were managed
using inserts ≤ 12.5 mm thick, and none had mediolateral laxity
>
2 mm from a mechanical axis of 0° at the end of the surgery. At
a mean follow-up of 26.4 months (13 to 48) there was significant
improvement in the mean Knee Society, Oxford knee and Western Ontario
and McMaster Universities Osteoarthritis Index scores compared with
the pre-operative values. The mean knee flexion improved from 105°
(80° to 125°) pre-operatively to 131° (120° to 145°), and none of
the limbs had recurrent recurvatum. These early results show that total knee replacement using computer
navigation and an algorithmic approach for arthritic knees with
a recurvatum deformity can give excellent radiological and functional
outcomes without recurrent deformity.
We report the long-term results of the management
of neglected chronically infected total knee replacements with a
two-stage re-implantation protocol. In 18 of 34 patients (53%) a
resistant organism was isolated. All cases were treated by the same
surgical team in a specialist centre and had a mean follow-up of
12.1 years (10 to 14). They were evaluated clinically and radiologically
using the Knee Society Score (KSS) and the American Knee Society Roentgenographic
scoring system, respectively. One patient died after eight years
from an unrelated cause and two were lost to follow-up. Three patients
(8.8%) developed a recurrent infection for which further surgery
was required. The infection was eradicated successfully in 31 patients
(91.1%). There was one case of aseptic loosening after 13 years.
We found a significant improvement in the KSS at final follow-up
(p <
0.001).
The efficacy of circumpatellar electrocautery in reducing the incidence of post-operative anterior knee pain is unknown. We conducted a single-centre, outcome-assessor and patient-blinded, parallel-group, randomised, controlled trial to compare circumpatellar electrocautery with no electrocautery in total knee replacement in the absence of patellar resurfacing. Patients requiring knee replacement for primary osteoarthritis were randomly assigned circumpatellar electrocautery (intervention group) or no electrocautery (control group). The primary outcome measure was the incidence of anterior knee pain. A secondary measure was the standardised clinical and patient-reported outcomes determined by the American Knee Society scores and the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index. A total of 131 knees received circumpatellar electrocautery and 131 had no electrocautery. The overall incidence of anterior knee pain at follow-up at one year was 26% (20% to 31%), with 19% (12% to 26%) in the intervention group and 32% (24% to 40%) in the control group (p = 0.02). The relative risk reduction from electrocautery was 40% (9% to 61%) and the number needed to treat was 7.7 (4.3 to 41.4). The intervention group had a better mean total WOMAC score at follow-up at one year compared with the control group (16.3 (0 to 77.7) Our study suggests that in the absence of patellar resurfacing electrocautery around the margin of the patella improves the outcome of total knee replacement.
This annotation considers the place of extra-articular
reconstruction in the treatment of anterior cruciate ligament (ACL)
deficiency. Extra-articular reconstruction has been employed over
the last century to address ACL deficiency. However, the technique
has not gained favour, primarily due to residual instability and
the subsequent development of degenerative changes in the lateral
compartment of the knee. Thus intra-articular reconstruction has
become the technique of choice. However, intra-articular reconstruction
does not restore normal knee kinematics. Some authors have recommended
extra-articular reconstruction in conjunction with an intra-articular
technique. The anatomy and biomechanics of the anterolateral structures
of the knee remain largely undetermined. Further studies to establish
the structure and function of the anterolateral structures may lead
to more anatomical extra-articular reconstruction techniques that
supplement intra-articular reconstruction. This might reduce residual
pivot shift after an intra-articular reconstruction and thus improve
the post-operative kinematics of the knee.
In this case report a four-year-old girl with ulnar dimelia is described. She had six digits without mirror symmetry in her right hand. The first pre-axial digit was excised and true pollicisation performed for the second pre-axial digit. The arterial anatomy was abnormal but there was not symmetrical development of the arterial tree.
The lateral subvastus approach combined with an osteotomy of the tibial tubercle is a recognised, but rarely used approach for total knee replacement (TKR). A total of 32 patients undergoing primary TKR was randomised into two groups, in one of which the lateral subvastus approach combined with a tibial tubercle osteotomy and in the other the medial parapatellar approach were used. The patients were assessed radiologically and clinically using measurement of the range of movement, a visual analogue patient satisfaction score, the Western Ontario McMasters University Osteoarthritis Index and the American Knee Society score. Four patients were lost to the complete follow-up at two years. At two years there were no significant differences between the groups in any of the parameters for clinical outcome. In the lateral approach group there was one complication due to displacement of the tibial tubercle osteotomy and two osteotomies took more than six months to unite. In the medial approach group, one patient had a partial tear of the quadriceps. There was a significantly greater incidence of lateral patellar subluxation in the medial approach group (3 of 12) compared with the lateral approach group (0 of 16) (p = 0.034), but without any apparent clinical detriment. We conclude that the lateral approach with tibial tubercle osteotomy is a safe technique with an outcome comparable with that of the medial parapatellar approach for TKR, but the increased surgical time and its specific complications do not support its routine use. It would seem to be more appropriate to reserve this technique for patients in whom problems with patellar tracking are anticipated.
This conversation represents an attempt by several
arthroplasty surgeons to critique several abstracts presented over
the last year as well as to use them as a jumping off point for trying
to figure out where they fit in into our current understanding of
multiple issues in modern hip and knee arthroplasty.