Advertisement for orthosearch.org.uk
Results 221 - 240 of 3752
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 265 - 272
1 Mar 2003
Pirpiris M Trivett A Baker R Rodda J Nattrass GR Graham HK

We describe the results of a prospective study of 28 children with spastic diplegia and in-toed gait, who had bilateral femoral derotation osteotomies undertaken at either the proximal intertrochanteric or the distal supracondylar level of the femur. Preoperative clinical evaluation and three-dimensional movement analysis determined any additional soft-tissue surgery. Distal osteotomy was faster with significantly lower blood loss than proximal osteotomy. The children in the distal group achieved independent walking earlier than those in the proximal group (6.9 ± 1.3 v 10.7 ± 1.7 weeks; p < 0.001). Transverse plane kinematics demonstrated clinically significant improvements in rotation of the hip and the foot progression angle in both groups. Correction of rotation of the hip was from 17 ± 11° internal to 3 ± 9.5° external in the proximal group and from 9 ± 14° internal to 4 ± 12.4° external in the distal group. Correction of the foot progression angle was from a mean of 10.0 ± 17.3° internal to 13.0 ± 11.8° external in the proximal group (p < 0.001) compared with a mean of 7.0 ± 19.4° internal to 10.0 ± 12.2° external in the distal group (p < 0.001). Femoral derotation osteotomy at both levels gives comparable excellent correction of rotation of the hip and foot progression angles in children with spastic diplegia


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 830 - 836
1 Aug 2000
Haddad FS Garbuz DS Masri BA Duncan CP

There are few medium- and long-term data on the outcome of the use of proximal femoral structural allografts in revision hip arthroplasty. This is a study of a consecutive series of 40 proximal femoral allografts performed for failed total hip replacements using the same technique with a minimum follow-up of five years (mean 8.8 years; range 5 to 11.5 years). In all cases the stem was cemented into both the allograft and the host femur. The proximal femur of the host was resected in 37 cases. There were four early revisions (10%), two for infection, one for nonunion of the allograft-host junction, and one for allograft resorption noted at the time of revision of a failed acetabular reconstruction. Junctional nonunion was seen in three patients (8%), two of whom were managed successfully by bone grafting, and bone grafting and plating respectively. Instability was observed in four (10%). Trochanteric nonunion was seen in 18 patients (46%) and trochanteric escape in ten of these (27%). The mean Harris hip score improved from 39 to 79. Severe resorption involving the full thickness of the allograft was seen in seven patients (17.5%). This progressed rapidly and silently, but has yet to cause failure of any of the reconstructions. Profound resorption of the allograft may be related to a combination of factors, including a slow form of immune rejection, stress shielding and resorption due to mechanical disuse with solid cemented distal fixation, and the absence of any masking or protective effect which may be provided by the retention of the bivalved host bone as a vascularised onlay autograft. Although continued surveillance is warranted, the very good medium-term clinical results justify the continued use of structural allografts for failed total hip replacements with severe loss of proximal femoral bone


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1000 - 1004
1 Aug 2008
Wraighte PJ Howard PW

Femoral impaction bone allografting has been developed as a means of restoring bone stock in revision total hip replacement. We report the results of 75 consecutive patients (75 hips) with a mean age of 68 years (35 to 87) who underwent impaction grafting using the Exeter collarless, polished, tapered femoral stem between 1992 and 1998. The mean follow-up period was 10.5 years (6.3 to 14.1). The median pre-operative bone defect score was 3 (interquartile range (IQR) 2 to 3) using the Endo-Klinik classification. The median subsidence at one year post-operatively was 2 mm (IQR 1 to 3). At the final review the median Harris hip score was 80.6 (IQR 67.6 to 88.9) and the median subsidence 2 mm (IQR 1 to 4). Incorporation of the allograft into trabecular bone and secondary remodelling were noted radiologically at the final follow-up in 87% (393 of 452 zones) and 40% (181 of 452 zones), respectively. Subsidence of the Exeter stem correlated with the pre-operative Endo-Klinik bone loss score (p = 0.037). The degree of subsidence at one year had a strong association with long-term subsidence (p < 0.001). There was a significant correlation between previous revision surgery and a poor Harris Hip score (p = 0.028), and those who had undergone previous revision surgery for infection had a higher risk of complications (p = 0.048). Survivorship at 10.5 years with any further femoral operation as the end-point was 92% (95% confidence interval 82 to 97)


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1435 - 1441
1 Oct 2010
Bischel OE Böhm PM

Endoprosthetic reconstruction following resection of 31 tumours of the proximal femur in 30 patients was performed using a Wagner SL femoral revision stem. The mean follow-up was 25.6 months (0.6 to 130.0). Of the 28 patients with a metastasis, 27 died within a mean follow-up period of 18.1 months (0.6 to 56.3) after the operation, and the remaining patient was excluded from the study 44.4 months post-operatively when the stem was removed. The two patients with primary bone tumours were still alive at the latest follow-up of 81.0 and 130.0 months, respectively. One stem only was removed for suspected low-grade infection 44.4 months post-operatively. The worst-case survival rate with removal of the stem for any cause and/or loss to follow-up was 80.0% (95% confidence interval 44.9 to 100) at 130.0 months. The mean Karnofsky index increased from 44.2% (20% to 70%) pre-operatively to 59.7% (0% to 100%) post-operatively, and the mean Merle d’Aubigné score improved from 4.5 (0 to 15) to 12.0 (0 to 18). The mean post-operative Musculoskeletal Tumour Society score was 62.4% (3.3% to 100%). The Wagner SL femoral revision stem offers an alternative to special tumour prostheses for the treatment of primary and secondary tumours of the proximal femur. The mid-term results are very promising, but long-term experience is necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 922 - 923
1 Nov 1995
Haddad F Williams R

We randomised 50 patients with extracapsular fractures of the femoral neck to receive either a bupivacaine femoral nerve block or systemic analgesia alone. A femoral nerve block was found to be an easy and effective procedure which significantly reduced perioperative analgesic requirements and postoperative morbidity


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 952 - 958
1 Sep 2000
Morrey BF Adams RA Kessler M

Between 1985 and 1993, 146 patients (162 hips) had total hip replacement (THR) using a conservative uncemented femoral component. The mean age of the patients was 50.8 years and the mean follow-up was 6.2 years (2 to 13). One patient was lost to follow-up, one died within two years of surgery and one had a revision procedure after a fracture sustained in a road-traffic accident. For the remaining 159, Kaplan-Meier survival analysis was calculated for the incidence of revision because of mechanical loosening or osteolysis. Survival without mechanical loosening at both five and ten years was 98.2%. Survival without osteolysis was 99% at five and 91% at ten years. The Harris hip score improved from a mean of 66.3 before to 90.4 at follow-up. Of particular note is the lack of thigh pain in this group. Radiological analysis showed that 139 stems (88%) had no measurable subsidence, 8 (5%) had less than 2 mm and 12 (7%) had more than 2 mm. Two of the eight and one of the 12 were revised for mechanical loosening. Nine hips were revised for late loosening associated with osteolysis. No reaming of the femoral canal was associated with statistically significant less blood loss compared with a comparable control group of uncemented implants (p < 0.0001). Our study suggests that using a conservative femoral implant does not protect against wear debris but the reliable mechanical stability (98.2%) makes this an attractive design of implant particularly for young patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 107 - 108
1 Jan 2007
Robinson KP Carroll FA Bull MJ McClelland M Stockley I

We report a case of local compression-induced transient femoral nerve palsy in a 46-year-old man. He had previously undergone surgical release of the soft tissues anterior to both hip joints because of contractures following spinal injury. An MRI scan confirmed a synovial cyst originating from the left hip joint, lying adjacent to the femoral nerve. The cyst expanded on standing, causing a transient femoral nerve palsy. The symptoms resolved after excision of the cyst


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 982 - 986
1 Nov 1999
Ritter MA Zhou H Keating CM Keating EM Faris PM Meding JB Berend ME

We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral alignment. The mean follow-up was for 11.7 years. Femoral loosening was demonstrable radiologically in 15 hips (8.1%), ten (5.4%) of which were revised during the period of follow-up. Only when the first postoperative radiograph showed a thin cement mantle in Gruen zone 5 was there a significant association with failure of the femoral component. There were 12 loose acetabular components (6.5%), nine (4.8%) of which were revised. When the initial radiograph after operation showed radiolucency in DeLee and Charnley zone 1, the incidence of acetabular loosening was 28.21%. If such radiolucency was not present, the incidence of acetabular loosening was only 0.69%. Our findings emphasise the importance of careful cementing


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 556 - 560
1 May 2002
Nötzli HP Wyss TF Stoecklin CH Schmid MR Treiber K Hodler J

Impingement by prominence at the femoral head-neck junction on the anterior acetabular rim may cause early osteoarthritis. Our aim was to develop a simple method to describe concavity at this junction, and then to test it by its ability to distinguish quantitatively a group of patients with clinical evidence of impingement from asymptomatic individuals who had normal hips on examination. MR scans of 39 patients with groin pain, decreased internal rotation and a positive impingement test were compared with those of 35 asymptomatic control subjects. The waist of the femoral head-neck junction was identified on tilted axial MR scans passing through the centre of the head. The anterior margin of the waist of the femoral neck was defined and measured by an angle (α). In addition, the width of the femoral head-neck junction was measured at two sites. Repeated measurements showed good reproducibility among four observers. The angle α averaged 74.0° for the patients and 42.0° for the control group (p < 0.001). Significant differences were also found between the patient and control groups for the scaled width of the femoral neck at both sites. Using standardised MRI, the symptomatic hips of patients who have impingement have significantly less concavity at the femoral head-neck junction than do normal hips. This test may be of value in patients with loss of internal rotation for which a cause is not found


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1388 - 1393
1 Oct 2009
Aird JJ Hogg A Rollinson P

In 1937 Blount described a series of 28 patients with ‘Tibia vara’. Since then, a number of deformities in the tibia and the femur have been described in association with this condition. We analysed 14 children with Blount’s disease who were entered into a cross-sectional study. Their mean age was 10 (2 to 18). They underwent a clinical assessment of the rotational profile of their legs and a CT assessment of the angle of anteversion of their hips (femoral version). We compared our results to previously published controls. A statistically significant increase in femoral anteversion was noted in the affected legs, with on average the femurs in patients with Blount’s disease being 26° more anteverted than those in previously published controls. We believe this to be a previously unrecognised component of Blount’s disease, and that the marked intoeing seen in the disease may be partly caused by internal femoral version, in addition to the well-recognised internal tibial version


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 461 - 461
1 Apr 2001
FURLONG R


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1124 - 1129
1 Aug 2014
Segaren N Abdul-Jabar HB Hashemi-Nejad A

Proximal femoral varus osteotomy improves the biomechanics of the hip and can stimulate normal acetabular development in a dysplastic hip. Medial closing wedge osteotomy remains the most popular technique, but is associated with shortening of the ipsilateral femur. We produced a trigonometric formula which may be used pre-operatively to predict the resultant leg length discrepancy (LLD). We retrospectively examined the influence of the choice of angle in a closing wedge femoral osteotomy on LLD in 120 patients (135 osteotomies, 53% male, mean age six years, (3 to 21), 96% caucasian) over a 15-year period (1998 to 2013). A total of 16 of these patients were excluded due to under or over varus correction. The patients were divided into three age groups: paediatric (< 10 years), adolescent (10 to 16 years) and adult (> 16 years). When using the same saw blades as in this series, the results indicated that for each 10° of angle of resection the resultant LLD equates approximately to multiples of 4 mm, 8 mm and 12 mm in the three age groups, respectively. Statistical testing of the 59 patients who had a complete set of pre- and post-operative standing long leg radiographs, revealed a Pearson’s correlation coefficient for predicted versus radiologically observed shortening when using a wedge of either 10° or 20° of 0.93 (p <  0.001). The 95% limits of agreement from the Bland–Altman analysis for this subgroup were –3.5 mm to +3.3 mm. It has been accepted that a 10 mm discrepancy is clinically acceptable. This study identified a geometric model that provided satisfactory accuracy when using specific saw blades of known thicknesses for this formula to be used in clinical practice. Cite this article: Bone Joint J 2014;96-B:1124–9


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 610 - 614
1 Aug 1989
Sponseller P Desai S Millis M

We studied the pattern of proximal femoral growth after severe Perthes' disease (Catterall grade III or IV) by retrospective analysis of serial radiographs in 52 hips (46 patients). Our aim was to determine the relationship between proximal femoral growth abnormalities and metaphyseal cysts, epiphyseal extrusion, physeal narrowing, and extensive epiphyseal necrosis. The average follow-up after treatment was 9.8 years (range 4 to 16 years), and 37 of the hips were followed to skeletal maturity. Slowing of proximal femoral growth was common: symmetrical abnormality was seen in 26 hips and asymmetrical abnormality in nine. However, definite premature closure of the proximal femoral physis was seen in only three hips. Abnormality seemed to be due to altered growth velocity rather than to bar formation in most cases. Metaphyseal cysts, epiphyseal extrusion and physeal narrowing during the active stage of the disease, alone or in combination, were found to be neither sensitive nor specific predictors of the subsequent growth pattern


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 450 - 453
1 Nov 1980
Loudon Charnley J

A method is described of measuring radiological subsidence of a femoral prosthesis in relation to the femur after total hip arthroplasty. The method depends on measuring the distance from the tip of the femoral prosthesis to a fixed point in the bone. Subsidence after the use of a conventional design of femoral stem is compared with that after the use of a stem with a dorsal flange (Cobra). A significant reduction in the incidence and amount of subsidence was found when using the dorsal flange. There was also a notable absence of transverse fractures involving the cement near the tip of the stem, which occurred in 26 per cent of the cases using a conventional prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 607 - 613
1 May 2002
Martelli S Pinskerova V

We report a study of the shapes of the tibial and femoral articular surfaces in sagittal, frontal and coronal planes which was performed on cadaver knees using two techniques, MRI and computer interpolation of sections of the articular surfaces acquired by a three-dimensional digitiser. The findings using MRI, confirmed in a previous study by dissection, were the same as those using the digitiser. Thus both methods appear to be valid anatomical tools. The tibial and femoral articular surfaces can be divided into anterior segments, contacting from 0° to 20 ± 10° of flexion, and posterior segments, contacting from 20 ± 10° to 120° of flexion. The medial and lateral compartments are asymmetrical, particularly anteriorly. Posteromedially, the femur is spherical and is located in a conforming, but partly deficient, tibial socket. Posterolaterally, it is circular only in the sagittal section and the tibia is flat centrally, sloping downwards both anteriorly and posteriorly to receive the meniscal horns. Anteromedially, the femur is convex with a sagittal radius larger than that posteriorly, while the tibia is flat sloping upwards and forwards. Anterolaterally, both the femoral and tibial surfaces are largely deficient. These shapes suggest that medially the femur can rotate on the tibia through three axes intersecting in the middle of the femoral sphere, but that the sphere can only translate anteroposteriorly and even then to a limited extent. Laterally, the femur can freely translate anteroposteriorly, but can only rotate around a transverse axis for that part of the arc, i.e., near extension, during which it comes into contact with the tibia through its flattened distal/medial surface as against its spherical posterior surface


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 349 - 355
1 Mar 2010
Babis GC Sakellariou VI O’Connor MI Hanssen AD Sim FH

We report the use of an allograft prosthetic composite for reconstruction of the skeletal defect in complex revision total hip replacement for severe proximal femoral bone loss. Between 1986 and 1999, 72 patients (20 men, 52 women) with a mean age of 59.9 years (38 to 78) underwent reconstruction using this technique. At a mean follow-up of 12 years (8 to 20) 57 patients were alive, 14 had died and one was lost to follow-up. Further revision was performed in 19 hips at a mean of 44.5 months (11 to 153) post-operatively. Causes of failure were aseptic loosening in four, allograft resorption in three, allograft nonunion in two, allograft fracture in four, fracture of the stem in one, and deep infection in five. The survivorship of the allograft-prosthesis composite at ten years was 69.0% (95% confidence interval 67.7 to 70.3) with 26 patients remaining at risk. Survivorship was statistically significantly affected by the severity of the pre-operative bone loss (Paprosky type IV; p = 0.019), the number of previous hip revisions exceeding two (p = 0.047), and the length of the allograft used (p = 0.005)


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 143 - 147
1 Jan 1999
Aamodt A Kvistad KA Andersen E Lund-Larsen J Eine J Benum P Husby OS

CT and advanced computer-aided design techniques offer the means for designing customised femoral stems. Our aim was to determine the Hounsfield (HU) value of the bone at the corticocancellous interface, as part of the criteria for the design algorithm. We obtained transverse CT images from eight human cadaver femora. The proximal femoral canal was rasped until contact with dense cortical bone was achieved. The femora were cut into several sections corresponding to the slice positions of the CT images. After obtaining a computerised image of the anatomical sections using a scanner, the inner cortical contour was outlined and transferred to the corresponding CT image. The pixels beneath this contour represent the CT density of the bone remaining after surgical rasping. Contours were generated automatically at nine HU levels from 300 to 1100 and the mean distance between the transferred contour and each of the HU-generated contours was computed. The contour generated along the 600-HU pixels was closest to the inner cortical contour of the rasped femur and therefore 600 HU seem to be the CT density of the corticocancellous interface in the proximal part of cadaver femora. Generally, femoral bone with a CT density beyond 600 HU is not removable by conventional reamers. Thus, we recommend the 600 HU threshold as one of several criteria for the design of custom femoral implants from CT data


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 652 - 654
1 Jul 2000
Tornetta P Tiburzi D

Retrograde femoral nailing is gaining in popularity. We report a prospective, randomised comparison of antegrade and retrograde procedures in 68 patients with 69 fractures of the femoral shaft. All nails were inserted after appropriate reaming. There was no difference in operating time, blood loss, technical complications, size of nail or reamer, or transfusion requirements. There were more problems of length and rotation using a retrograde technique on a radiolucent table than with an antegrade approach on a fracture table. All fractures in both groups healed and there was no difference in the time taken to achieve union. Although retrograde nailing is a promising technique the skills required need practice. A longer period of follow-up is necessary to determine whether there are long-term problems in the knee after such surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1372 - 1379
1 Oct 2008
Robin J Graham HK Selber P Dobson F Smith K Baker R

There is much debate about the nature and extent of deformities in the proximal femur in children with cerebral palsy. Most authorities accept that increased femoral anteversion is common, but its incidence, severity and clinical significance are less clear. Coxa valga is more controversial and many authorities state that it is a radiological artefact rather than a true deformity. We measured femoral anteversion clinically and the neck-shaft angle radiologically in 292 children with cerebral palsy. This represented 78% of a large, population-based cohort of children with cerebral palsy which included all motor types, topographical distributions and functional levels as determined by the gross motor function classification system. The mean femoral neck anteversion was 36.5° (11° to 67.5°) and the mean neck-shaft angle 147.5° (130° to 178°). These were both increased compared with values in normally developing children. The mean femoral neck anteversion was 30.4° (11° to 50°) at gross motor function classification system level I, 35.5° (8° to 65°) at level II and then plateaued at approximately 40.0° (25° to 67.5°) at levels III, IV and V. The mean neck-shaft angle increased in a step-wise manner from 135.9° (130° to 145°) at gross motor function classification system level I to 163.0° (151° to 178°) at level V. The migration percentage increased in a similar pattern and was closely related to femoral deformity. Based on these findings we believe that displacement of the hip in patients with cerebral palsy can be explained mainly by the abnormal shape of the proximal femur, as a result of delayed walking, limited walking or inability to walk. This has clinical implications for the management of hip displacement in children with cerebral palsy


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 955 - 961
1 Jul 2009
Simpson AHWR Shalaby H Keenan G

Femoral lengthening using the Intramedullary Skeletal Kinetic Distractor is a new technique. However, with intramedullary distraction the surgeon has less control over the lengthening process. Therefore, 33 femora lengthened with this device were assessed to evaluate the effect of operative variables under the surgeon’s control on the course of lengthening. The desired lengthening was achieved in 32 of 33 limbs. Problems encountered included difficulty in achieving length in eight femora (24%) and uncontrolled lengthening in seven (21%). Uncontrolled lengthening was more likely if the osteotomy was placed with less than 80 mm of the thick portion of the nail in the distal fragment (p = 0.052), and a failure to lengthen was more likely if there was over 125 mm in the distal fragment (p = 0.008). The latter problem was reduced with over-reaming by 2.5 mm to 3 mm. Previous intramedullary nailing also predisposed to uncontrolled lengthening (p = 0.042), and these patients required less reaming. Using the Intramedullary Skeletal Kinetic Distractor, good outcomes were obtained; problems were minimised by optimising the position of the osteotomy and the amount of over-reaming performed