We describe the application of a non-invasive extendible endoprosthetic replacement in skeletally-mature patients undergoing revision for failed joint replacement with resultant limb-length inequality after malignant or non-malignant disease. This prosthesis was developed for tumour surgery in skeletally-immature patients but has now been adapted for use in revision procedures to reconstruct the joint or facilitate an arthrodesis, replace bony defects and allow limb length to be restored gradually in the post-operative period. We record the short-term results in nine patients who have had this procedure after multiple previous reconstructive operations. In six, the initial reconstruction had been performed with either allograft or endoprosthetic replacement for neoplastic disease and in three for non-neoplastic disease. The essential components of the prosthesis are a magnetic disc, a gearbox and a drive screw which allows painless lengthening of the prosthesis using the principle of electromagnetic induction. The mean age of the patients was 37 years (18 to 68) with a mean follow-up of 34 months (12 to 62). They had previously undergone a mean of six (2 to 14) open procedures on the affected limb before revision with the non-invasive extendible endoprosthesis. The mean length gained was 56 mm (19 to 107) requiring a mean of nine (3 to 20) lengthening episodes performed in the outpatient department. There was one case of recurrent infection after revision of a previously infected implant and one fracture of the prosthesis after a fall. No amputations were performed. Planned exchange of the prosthesis was required in three patients after attainment of the maximum lengthening capacity of the implant. There was no failure of the lengthening mechanism. The Mean Musculoskeletal Tumour Society rating score was 22 of 30 available points (18 to 28). The use of a non-invasive extendible endoprosthesis in this manner provided patients with good
In a prospective study, 204 consecutive patients with displaced Colles' fractures had closed reduction then plaster immobilisation. Three different positions of the wrist in plaster were randomly allocated: palmar flexion, neutral and dorsiflexion. The results in the three groups were compared. Fractures immobilised with the wrist in dorsiflexion showed the lowest incidence of redisplacement, especially of dorsal tilt, and had the best early
We performed a prospective, randomised trial on 120 patients with redisplaced fractures of the distal radius comparing four methods of treatment. The four treatment groups, each containing 30 patients, were remanipulation and plaster, open reduction and bone grafting, and closed external fixation with and without mobilisation of the wrist at three weeks. The radiological results showed improvement in angulation of the distal radius for the open reduction and bone grafting group.
A retrospective study of 23 acetabular fractures in patients up to 17 years of age is presented, with an average follow-up of eight years. Good or excellent
In a prospective, randomised, multicentre study, 112 patients (99 men and 13 women, aged between 21 and 63 years) with acute, complete rupture of tendo Achillis were allocated either to surgical treatment followed by early functional rehabilitation, using a brace, or to non-surgical treatment, with plaster splintage for eight weeks. The period of follow-up was for two years. Evaluation was undertaken by independent observers and comprised interviews, clinical measurements, isokinetic muscle performance tests, heel-raise tests and an overall outcome score. The rate of rerupture was 20.8% after non-surgical and 1.7% after surgical treatment (p <
0.001). Surgical and non-surgical treatment produced equally good
We carried out a randomised, prospective, multicentre clinical trial of the treatment of Colles’ fractures. A total of 339 patients was placed into two groups, those with minimally displaced fractures not requiring manipulation (151 patients) and those with displaced fractures which needed manipulation (188 patients). Treatment was by either a conventional Colles’ plaster cast (a control group) or with a prefabricated functional brace (the Aberdeen Colles’ fracture brace). Similar results were obtained in both groups with regard to the reduction and to pain scores but the brace provided better grip strength in the early stages of treatment. This was statistically significant after five weeks for both manipulated and non-manipulated fractures. At the tenth day the results were statistically significant only in manipulated fractures. There was no significant difference in the functional outcome between the two treatment groups. However, younger patients and those with less initial displacement had better
We describe a method of audit of a type of total knee replacement, including some details of the organisational difficulties of administering multicentre studies, and draw attention to how this can be done using industrial funding without prejudicing the study. This is a prospective record of 1439 patients who had an Insall-Burstein II (IBII) prosthesis implanted between 1990 and 1994. The data were collected using the American Knee Society scoring system. A method of storing radiographs digitally at low cost is also described. The results emphasise the need for the long-term collection of data on commonly used devices implanted by a cross-section of surgeons. We conclude that for most patients the IBII cemented, posteriorly stabilised, cruciate-substituting prosthesis will relieve pain and give excellent
Over a 16-year period, 135 custom-made distal femoral prostheses, based on a fully constrained Stanmore-type knee replacement, were used in the treatment of primary malignant or aggressive benign tumours. Survivorship analysis showed a cumulative success rate of 72% at five years and 64% at seven years. Intact prostheses in 91% of the surviving patients gave good or excellent
The results are presented of 47 compression arthrodeses of the ankle performed for osteoarthritis in 44 patients. In 26 cases the transverse anterior incision of Charnley had been used and in 21 cases medial and lateral incisions with division of the malleoli. Complications included infection (19%), non-union (14.9%) and malposition requiring a further procedure (8.5%). Three patients (6.4%) eventually had an amputation. Clinical assessment using a standard grading method showed that the
A new technique for the treatment of displaced fractures of the proximal humerus is described. Twelve fractures in 11 patients were managed by transcutaneous reduction using a Steinmann pin, and external fixation with a Hoffmann-type neutralising bar connected to two half-pins in the humeral head and three half-pins in the shaft. The pins were removed after four weeks. Two patients sustained redisplacement after a further injury, but in the others reduction was maintained. Two cases of pin-track infection resolved after antibiotics, but delayed union resulted. There were no neurovascular injuries and at follow-up of 6 to 12 months no refractures had been seen. The early
A randomised, prospective study was carried out on 60 patients with unstable fractures of the distal radius to compare bridging with non-bridging external fixation using pins placed in the distal fragment of the radius. The radiological results showed significant improvement in the non-bridging group at all stages of review. In particular, normal volar tilt and carpal alignment were regained and maintained. The
1. Open osteotomy near the tuberosity of the radius to enable correction of fixed supination deformity of the forearm in children is an alternative to Blount's closed osteoclasis of both bones. 2. In five out of six cases with residual obstetrical palsy substantial correction of the deformity was maintained. 3. The cosmetic result was impressive, especially in girls, but an improved function was also observed. If the hand is paralysed, correction of supination facilitates reconstruction. 4. Complications such as angulation, displacement, delayed union and synostosis of the proximal radius and ulna did not affect the final results. 5. With the method described a more or less permanent "blocking" of rotatory movement in the forearm was observed but this did not seem to impair the
1 . Thirty-six patients with complete irrecoverable brachial plexus lesions have been studied. 2. Function has been compared after 1) arthrodesis of the shoulder with amputation through the arm, 2) so-called reconstructive procedures, and 3) no operative treatment. 3. The results of reconstructive operations have been so disappointing that we believe that this type of treatment should be abandoned. 4. Amputation-arthrodesis offers a better
1. Nine out of ten patients who undergo McMurray osteotomy may expect lasting relief of pain. Seventy-five per cent should have a satisfactory
From 1987 to 1993 we treated 33 patients with 29 phalangeal and seven metacarpal fractures by external fixation using a mini-Hoffmann device. There were 27 open and 25 comminuted fractures. In 12 patients one or more tendons was involved. The mean follow-up was 4.4 years. Complications occurred in ten fractures; two required repositioning of the fixator. All the fractures healed. The
We evaluated the long-term results of 109 tibial plateau fractures, 61 treated by skeletal traction and early knee movement and 48 treated by surgery, at an average follow-up of 70 months. The
Ten patients underwent endoprosthetic replacement of the distal humerus for bone tumours over a period of 30 years. There were eight primary and two secondary tumours in four men and six women with a mean age of 47.5 years (15 to 76). The mean follow-up was eight years (9 months to 31 years). Four patients required further surgery, three having revision for aseptic loosening; two of these and one other later needing a rebushing. There were no cases of postoperative nerve palsy, infection, local recurrence or mechanical failure of the implant. Four patients died from their disease, all with the prosthesis functioning satisfactorily. At follow-up the mean flexion deformity of the elbow was 15° (0 to 35) and the mean range of flexion was 115° (110 to 135). The
We have reviewed 32 patients who sustained a substantial knee ligament injury during adolescence when their knee epiphyses were open. They were all treated non-operatively and re-examined and evaluated in detail after an average of eight years. There were 25 Grade II partial tears and seven Grade III complete tears. After Grade II injuries the
We have reviewed 42 of 52 consecutive patients at an average of 14 years after a tenodesis based on Evans' operation performed for chronic lateral instability of the ankle. Only 21 patients (50%) had satisfactory long-term
1 . A series of 166 fractures and fracture-dislocations of the dorso-lumbar spine has been reviewed. 2. A new method of classifying these injuries is suggested. 3. A type of fracture with lateral wedging, previously unidentified, which has certain distinctive clinical and anatomical features is described. 4. The factors responsible for redisplacement are discussed and it is considered that in most cases this is predictable from the outset. 5. At the present time orthodox treatment is based on the assumption that a perfect anatomical result is indispensable to a perfect