This study sought to determine the medium-term patient-reported and radiographic outcomes in patients undergoing surgery for hallux valgus. A total of 118 patients (162 feet) underwent surgery for hallux valgus between January 2008 and June 2009. The Manchester-Oxford Foot Questionnaire (MOXFQ), a validated tool for the assessment of outcome after surgery for hallux valgus, was used and patient satisfaction was sought. The medical records and radiographs were reviewed retrospectively. At a mean of 5.2 years (4.7 to 6.0) post-operatively, the median combined MOXFQ score was 7.8 (IQR:0 to 32.8). The median domain scores for pain, walking/standing, and social interaction were 10 (IQR: 0 to 45), 0 (IQR: 0 to 32.1) and 6.3 (IQR: 0 to 25) respectively. A total of 119 procedures (73.9%, in 90 patients) were reported as satisfactory but only 53 feet (32.7%, in 43 patients) were completely asymptomatic. The mean (SD) correction of hallux valgus, intermetatarsal, and distal metatarsal articular angles was 18.5° (8.8°), 5.7° (3.3°), and 16.6° (8.8°), respectively. Multivariable regression analysis identified that an American Association of Anesthesiologists grade of > 1 (Incident Rate Ratio (IRR) = 1.67, p-value = 0.011) and recurrent deformity (IRR = 1.77, p-value = 0.003) were associated with significantly worse MOXFQ scores. No correlation was found between the severity of deformity, the type, or degree of surgical correction and the outcome. When using a validated outcome score for the assessment of outcome after surgery for hallux valgus, the long-term results are worse than expected when compared with the short- and mid-term outcomes, with 25.9% of patients dissatisfied at a mean follow-up of 5.2 years.
Cite this article:
The aim of this retrospective cohort study was to identify any difference in femoral offset as measured on pre-operative anteroposterior (AP) radiographs of the pelvis, AP radiographs of the hip and corresponding CT scans in a consecutive series of 100 patients with primary end-stage osteoarthritis of the hip (43 men and 57 women with a mean age of 61 years (45 to 74) and a mean body mass index of 28 kg/m2 (20 to 45)).
Patients were positioned according to a standardised protocol to achieve reproducible projection and all images were calibrated. Inter- and intra-observer reliability was evaluated and agreement between methods was assessed using Bland-Altman plots.
In the entire cohort, the mean femoral offset was 39.0 mm (95% confidence interval (CI) 37.4 to 40.6) on radiographs of the pelvis, 44.0 mm (95% CI 42.4 to 45.6) on radiographs of the hip and 44.7 mm (95% CI 43.5 to 45.9) on CT scans. AP radiographs of the pelvis underestimated femoral offset by 13% when compared with CT (p < 0.001). No difference in mean femoral offset was seen between AP radiographs of the hip and CT (p = 0.191).
Our results suggest that femoral offset is significantly underestimated on AP radiographs of the pelvis but can be reliably and accurately assessed on AP radiographs of the hip in patients with primary end-stage hip osteoarthritis.
We, therefore, recommend that additional AP radiographs of the hip are obtained routinely for the pre-operative assessment of femoral offset when templating before total hip replacement.
We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed.
At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.
Nanotechnology is the study, production and controlled manipulation of materials with a grain size < 100 nm. At this level, the laws of classical mechanics fall away and those of quantum mechanics take over, resulting in unique behaviour of matter in terms of melting point, conductivity and reactivity. Additionally, and likely more significant, as grain size decreases, the ratio of surface area to volume drastically increases, allowing for greater interaction between implants and the surrounding cellular environment. This favourable increase in surface area plays an important role in mesenchymal cell differentiation and ultimately bone–implant interactions.
Basic science and translational research have revealed important potential applications for nanotechnology in orthopaedic surgery, particularly with regard to improving the interaction between implants and host bone. Nanophase materials more closely match the architecture of native trabecular bone, thereby greatly improving the osseo-integration of orthopaedic implants. Nanophase-coated prostheses can also reduce bacterial adhesion more than conventionally surfaced prostheses. Nanophase selenium has shown great promise when used for tumour reconstructions, as has nanophase silver in the management of traumatic wounds. Nanophase silver may significantly improve healing of peripheral nerve injuries, and nanophase gold has powerful anti-inflammatory effects on tendon inflammation.
Considerable advances must be made in our understanding of the potential health risks of production, implantation and wear patterns of nanophase devices before they are approved for clinical use. Their potential, however, is considerable, and is likely to benefit us all in the future.
Cite this article:
We conducted a meta-analysis, including randomised controlled trials (RCTs) and cohort studies, to examine the effect of patient-specific instruments (PSI) on radiological outcomes after total knee replacement (TKR) including: mechanical axis alignment and malalignment of the femoral and tibial components in the coronal, sagittal and axial planes, at a threshold of > 3º from neutral. Relative risks (RR) for malalignment were determined for all studies and for RCTs and cohort studies separately.
Of 325 studies initially identified, 16 met the eligibility criteria,
including eight RCTs and eight cohort studies. There was no significant
difference in the likelihood of mechanical axis malalignment with
PSI
We conclude that PSI does not improve the accuracy of alignment of the components in TKR compared with conventional instrumentation.
Cite this article:
The aim of this study was to investigate the effect of training on the arthroscopic performance of a group of medical students and to determine whether all students could be trained to competence. Thirty-three medical students with no previous experience of arthroscopy were randomised to a ‘Trained’ or an ‘Untrained’ cohort. They were required to carry out 30 episodes of two simulated arthroscopic tasks (one shoulder and one knee). The primary outcome variable was task success at each episode. Individuals achieved competence when their learning curve stabilised. The secondary outcome was technical dexterity, assessed objectively using a validated motion analysis system. Six subjects in the ‘Untrained’ cohort failed to achieve competence in the shoulder task, compared with one in the ‘Trained’ cohort. During the knee task, two subjects in each cohort failed to achieve competence. Based on the objective motion analysis parameters, the ‘Trained’ cohort performed better on the shoulder task (p < 0.05) but there was no significant difference for the knee task (p > 0.05).
Although
A new anterior intrapelvic approach for the surgical
management of displaced acetabular fractures involving predominantly
the anterior column and the quadrilateral plate is described. In
order to establish five ‘windows’ for instrumentation, the extraperitoneal
space is entered along the lateral border of the rectus abdominis
muscle. This is the so-called ‘Pararectus’ approach. The feasibility
of safe dissection and optimal instrumentation of the pelvis was
assessed in five cadavers (ten hemipelves) before implementation
in a series of 20 patients with a mean age of 59 years (17 to 90),
of whom 17 were male. The clinical evaluation was undertaken between
December 2009 and December 2010. The quality of reduction was assessed
with post-operative CT scans and the occurrence of intra-operative
complications was noted.
In the treatment of acetabular fractures predominantly involving the anterior column and the quadrilateral plate, the Pararectus approach allowed anatomical restoration with minimal morbidity related to the surgical access.
Introduction
Wear of polyethylene inserts plays an important role in failure
of total knee replacement and can be monitored
Method
Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision.
Damage to the cartilage of the distal radioulnar joint frequently leads to pain and limitation of movement, therefore repair of this joint cartilage would be highly desirable. The purpose of this study was to investigate the fixation of scaffold in cartilage defects of this joint as part of matrix-assisted regenerative autologous cartilage techniques. Two techniques of fixation of collagen scaffolds, one involving fibrin glue alone and one with fibrin glue and sutures, were compared in artificially created cartilage defects of the distal radioulnar joint in a human cadaver. After being subjected to continuous passive rotation, the methods of fixation were evaluated for cover of the defect and pull out force.
No statistically significant differences were found between the
two techniques for either cover of the defect or integrity of the
scaffold. However, a significantly increased mean pull out force
was found for the combined procedure, 0.665 N (0.150 to 1.160)
This suggests that although successful fixation of a collagen type I/III scaffold in a distal radioulnar joint cartilage defect is feasible with both forms of fixation, fixation with glue and sutures is preferable.
Cite this article:
Large-head metal-on-metal total hip replacement has a failure rate of almost 8% at five years, three times the revision rate of conventional hip replacement. Unexplained pain remains a feature of this type of arthroplasty.
All designs of the femoral component of large-head metal-on-metal total hip replacements share a unique characteristic: a subtended angle of 120° defining the proportion of a sphere that the head represents. Using MRI, we measured the contact area of the iliopsoas tendon on the femoral head in sagittal reconstruction of 20 hips of patients with symptomatic femoroacetabular impingement. We also measured the articular extent of the femoral head on 40 normal hips and ten with cam-type deformities. Finally, we performed virtual hip resurfacing on normal and cam-type hips, avoiding overhang of the metal rim inferomedially.
The articular surface of the femoral head has a subtended angle of 120° anteriorly and posteriorly, but only 100° medially. Virtual surgery in a normally shaped femoral head showed a 20° skirt of metal protruding medially where iliopsoas articulates.
The excessive extent of the large-diameter femoral components may cause iliopsoas impingement independently of the acetabular component. This may be the cause of postoperative pain with these implants.
Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°).
Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001).
This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs.
Cite this article:
Cubitus varus is the most frequent complication following the treatment of supracondylar humeral fractures in children. We investigated data from publications reporting on the surgical management of cubitus varus found in electronic searches of Ovid/MEDLINE and Cochrane Library databases. In 894 children from 40 included studies, the mean age at initial injury was 5.7 years (3 to 8.6) and 9.8 years (4 to 15.7) at the time of secondary correction. The four osteotomy techniques were classified as lateral closing wedge, dome, complex (multiplanar) and distraction osteogenesis. A mean angular correction of 27.6º (18.5° to 37.0°) was achieved across all classes of osteotomy. The meta-analytical summary estimate for overall rate of good to excellent results was 87.8% (95% CI 84.4 to 91.2). No technique was shown to significantly affect the surgical outcome, and the risk of complications across all osteotomy classes was 14.5% (95% CI 10.6 to 18.5). Nerve palsies occurred in 2.53% of cases (95% CI 1.4 to 3.6), although 78.4% were transient. No one technique was found to be statistically safer or more effective than any other.
Cite this article:
Antegrade nailing of proximal humeral fractures
using a straight nail can damage the bony insertion of the supraspinatus
tendon and may lead to varus failure of the construct. In order
to establish the ideal anatomical landmarks for insertion of the
nail and their clinical relevance we analysed CT scans of bilateral
proximal humeri in 200 patients (mean age 45.1 years (
We therefore emphasise the need for ‘fastidious’ pre-operative planning to minimise this risk.
Cite this article:
There is great variability in acetabular component
orientation following hip replacement. The aims of this study were
to compare the component orientation at impaction with the orientation
measured on post-operative radiographs and identify factors that
influence the difference between the two. A total of 67 hip replacements
(52 total hip replacements and 15 hip resurfacings) were prospectively
studied. Intra-operatively, the orientation of the acetabular component
after impaction relative to the operating table was measured using
a validated stereo-photogrammetry protocol. Post-operatively, the
radiographic orientation was measured; the mean inclination/anteversion
was 43° (
This study demonstrated that in order to achieve a specific radiographic
orientation target, surgeons should implant the acetabular component
5° less inclined and 8° more anteverted than their target. Great
variability (2
Cite this article:
Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the
In this
The results from this
Objective
The main object of this study was to use a geometric morphometric approach to quantify the left-right symmetry of talus bones.
Methods
Analysis was carried out using CT scan images of 11 pairs of intact tali. Two important geometric parameters, volume and surface area, were quantified for left and right talus bones. The geometric shape variations between the right and left talus bones were also measured using deviation analysis. Furthermore, location of asymmetry in the geometric shapes were identified.
Results
Numerical results showed that talus bones are bilaterally symmetrical in nature, and the difference between the surface area of the left and right talus bones was less than 7.5%. Similarly, the difference in the volume of both bones was less than 7.5%. Results of the three-dimensional (3D) deviation analyses demonstrated the mean deviation between left and right talus bones were in the range of -0.74 mm to 0.62 mm. It was observed that in eight of 11 subjects, the deviation in symmetry occurred in regions that are clinically less important during talus surgery.
The augmentation of fixation with bone cement
is increasingly being used in the treatment of severe osteoporotic fractures.
We investigated the influence of bone quality on the mechanics of
augmentation of plate fixation in a distal femoral fracture model
(AO 33 A3 type). Eight osteoporotic and eight non-osteoporotic femoral
models were randomly assigned to either an augmented or a non-augmented
group. Fixation was performed using a locking compression plate.
In the augmented group additionally 1 ml of bone cement was injected
into the screw hole before insertion of the screw. Biomechanical
testing was performed in axial sinusoidal loading. Augmentation significantly
reduced the cut-out distance in the osteoporotic models by about
67% (non-augmented mean 0.30 mm (
Cite this article:
The December 2013 Spine Roundup360 looks at: Just how common is lumbar spinal stenosis?; How much will they bleed?; C5 palsy associated with stenosis; Atlanto-axial dislocations revisited; 3D predictors of progression in scoliosis; No difference in outcomes by surgical approach for fusion; Cervical balance changes after thoracolumbar surgery; and spinal surgeons first in space.
Between July 2000 and April 2004, 19 patients with bilateral spastic cerebral palsy who required an assistive device to walk had combined lengthening-transfer of the medial hamstrings as part of multilevel surgery. A standardised physical examination, measurement of the Functional Mobility Scale score and video or instrumented gait analysis were performed pre- and post-operatively. Static parameters (popliteal angle, flexion deformity of the knee) and sagittal knee kinematic parameters (knee flexion at initial contact, minimum knee flexion during stance, mean knee flexion during stance) were recorded. The mean length of follow-up was 25 months (14 to 45).
Statistically significant improvements in static and dynamic outcome parameters were found, corresponding to improvements in gait and functional mobility as determined by the Functional Mobility Scale. Mild hyperextension of the knee during gait developed in two patients and was controlled by adjustment of their ankle-foot orthosis. Residual flexion deformity > 10° occurred in both knees of one patient and was treated by anterior distal femoral physeal stapling. Two children also showed an improvement of one level in the Gross Motor Function Classification System.
Young adults with hip pain secondary to femoroacetabular impingement (FAI) are rapidly being recognised as an important cohort of orthopaedic patients. Interest in FAI has intensified over the last decade since its recognition as a precursor to arthritis of the hip and the number of publications related to the topic has increased exponentially in the last decade. Although not all patients with abnormal hip morphology develop osteoarthritis (OA), those with FAI-related joint damage rapidly develop premature OA. There are no explicit diagnostic criteria or definitive indications for surgical intervention in FAI. Surgery for symptomatic FAI appears to be most effective in younger individuals who have not yet developed irreversible OA. The difficulty in predicting prognosis in FAI means that avoiding unnecessary surgery in asymptomatic individuals, while undertaking intervention in those that are likely to develop premature OA poses a considerable dilemma. FAI treatment in the past has focused on open procedures that carry a potential risk of complications.
Recent developments in hip arthroscopy have facilitated a minimally invasive approach to the management of FAI with few complications in expert hands. Acetabular labral preservation and repair appears to provide superior results when compared with debridement alone. Arthroscopic correction of structural abnormalities is increasingly becoming the standard treatment for FAI, however there is a paucity of high-level evidence comparing open and arthroscopic techniques in patients with similar FAI morphology and degree of associated articular cartilage damage. Further research is needed to develop an understanding of the natural course of FAI, the definitive indications for surgery and the long-term outcomes.
Cite this article: