We reviewed radiographs and CT scans of 38 total hip arthroplasties which had dislocated (36 posteriorly; 2 anteriorly) and compared the alignment of the prosthetic components with those of 14 uncomplicated arthroplasties. No difference was found between the alignment of the prosthetic components in the two groups. In the seven patients who had reoperations, the cause of dislocation diagnosed by CT was confirmed in only two cases (one retroversion of the cup and one protruding osteophyte). Muscular imbalance rather than malposition of the components was the major factor determining dislocation. CT allows accurate measurement of cup and neck
Concurrent hip and spine pathologies can alter the biomechanics of spinopelvic mobility in primary total hip arthroplasty (THA). This study examines how differences in pelvic orientation of patients with spine fusions can increase the risk of dislocation risk after THA. We identified 84 patients (97 THAs) between 1998 and 2015 who had undergone spinal fusion prior to primary THA. Patients were stratified into three groups depending on the length of lumbar fusion and whether or not the sacrum was involved. Mean age was 71 years (40 to 87) and 54 patients (56%) were female. The mean body mass index (BMI) was 30 kg/m2 (19 to 45). Mean follow-up was six years (2 to 17). Patients were 1:2 matched to patients with primary THAs without spine fusion. Hazard ratios (HR) were calculated.Aims
Patients and Methods
We measured the range of rotation in both hips of 397 normal children and in the unaffected hip of 135 children with unilateral congenital dislocation of the hip. Both groups were assessed for generalised joint laxity. Joint laxity was more common in normal children with an internally centred arc of hip rotation than in normal children with a neutral or an externally rotated arc. The children with congenitally dislocated hips had significantly more joint laxity than did the control group and significantly more of them had an internally centred arc of hip rotation. We suggest that the lax joint capsule fails to mould away the neonatal
From 1956 to 1965, congenital dislocation of the hip was treated in a standard manner in 191 cases. Reduction and plaster immobilisation was followed by a period in a Batchelor type plaster in full medial rotation. Femoral neck
Mechanical abnormalities of the patellofemoral joint are among the many causes that have been suggested for adolescent knee pain. This study seeks to identify these factors. Measurements of joint mobility and lower limb morphology were made on 446 pupils at a comprehensive school, 136 of whom had suffered knee pain in the previous year. The pupils with symptoms enjoyed sporting activities significantly more than their symptom-free contemporaries. Joint mobility, the Q-angle, genu valgum and
The results obtained in a consecutive series of thirty-seven Pemberton operations for congenital dislocation or subluxation of the hip are reported. Over the period under review, 1967 to 1973, it was the only type of acetabuloplasty employed at Winford. Unless the mandatory concentric reduction could be obtained with ease, preliminary open reduction was favoured, especially in cases of primary care. Femoral rotation osteotomy was added for marked
1. After exclusion of the well known causes of torsion such as congenital dislocation of the hip, Legg-Perthes' disease, cerebral palsy and congenital talipes equinovarus, examination of 1,320 nearly normal children disclosed an incidence of 13·6 per cent toeing-in or toeing-out. 2. There was a female preponderance of seven to three on presentation decreasing to four to three in uncorrected cases. 3. There was persisting upper femoral torsion of greater than 10 degrees in two-thirds of all cases of toeing-in whether corrected or uncorrected. 4. When correction of toeing-in occurred it took place between four and seven years of age, but mainly at five years. 5. There was a normal angle of
Children who present late with hip dislocation may require femoral osteotomy after reduction, to correct valgus and
The hip’s capsular ligaments passively restrain extreme range of movement (ROM) by wrapping around the native femoral head/neck. We determined the effect of hip resurfacing arthroplasty (HRA), dual-mobility total hip arthroplasty (DM-THA), conventional THA, and surgical approach on ligament function. Eight paired cadaveric hip joints were skeletonized but retained the hip capsule. Capsular ROM restraint during controlled internal rotation (IR) and external rotation (ER) was measured before and after HRA, DM-THA, and conventional THA, with a posterior (right hips) and anterior capsulotomy (left hips).Aims
Materials and Methods
We studied the stability of cemented all-polyethylene keeled glenoid components by radiostereometric analysis (RSA) in 16 shoulders which had received a total shoulder replacement. There were 14 women (one bilateral) and one man with a mean age of 64 years. The diagnosis was osteoarthritis in eight and rheumatoid arthritis in seven. Two of the shoulders were excluded from the RSA study because of loosening of the tantalum markers. Three tantalum markers were inserted in the glenoid socket, two in the coracoid process and two in the acromion. The polyethylene keeled glenoid component was marked with three to five tantalum markers. Conventional radiological and RSA examinations were carried out at five to seven days, at four months and at one and two years after operation. Radiolucent lines were found in all except three shoulders. Migration was most pronounced in the distal direction and exceeded 1 mm in four shoulders. In ten shoulders rotation exceeded 2° in one or more axes with retroversion/
We report the results of anterior soft-tissue release of the hip for fixed flexion deformity in 17 patients (31 hips) with juvenile chronic arthritis. The mean age at operation was 8 years 6 months. All the patients were reviewed at one and three years and 11 (21 hips) were available for review at five years. The results were good as regards early pain relief and improved mobility. At one year, the average fixed flexion deformity was reduced from 35 degrees to 9.5 degrees, and at three years it was 18 degrees. This degree of improvement was maintained in the hips followed for five years. At 5 to 12 years' follow-up (mean 6.7) seven patients (14 hips) have required no further surgery and have maintained an acceptable range of motion. We discuss the influence of surgery on radiographic changes and on femoral neck
To analyse the value and accuracy of preoperative planning for total hip replacement (THR) we digitised electronically and compared the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs. The correct type of prosthesis was planned in 98%; the agreement between planned and actually used components was 92% on the femoral side and 90% on the acetabular side. The mean (± SD) absolute difference between the planned and actual position of the centre of rotation of the hip was 2.5 ± 1.1 mm vertically and 4.4 ± 2.1 mm horizontally. On average, the inclination of the acetabular component differed by 7 ± 2° and
Studying the indications for revision total hip arthroplasty (THA) may enable surgeons to change their practice during the initial procedure, thereby reducing the need for revision surgery. The aim of this study was to identify and describe the potentially avoidable indications for revision THA within five years of the initial procedure. A retrospective review of 117 patients (73 women, 44 men; mean age 61.5 years (27 to 88)) who met the inclusion criteria was conducted. Three adult reconstruction surgeons independently reviewed the radiographs and medical records, and they classified the revision THAs into two categories: potentially avoidable and unavoidable. Baseline demographics, perioperative details, and quality outcomes up to the last follow-up were recorded.Aims
Patients and Methods
We made a clinical study of polyethylene wear in 240 hips of 187 patients having primary total hip arthroplasties from 1989 to 1990, using uncemented Osteonics components, with a head size of 26 mm. We excluded cups with
This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up.Aims
Patients and Methods
Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort. We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59).Aims
Methods