Advertisement for orthosearch.org.uk
Results 261 - 280 of 3077
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 792 - 800
1 Jul 2022
Gustafsson K Kvist J Zhou C Eriksson M Rolfson O

Aims

The aim of this study was to estimate time to arthroplasty among patients with hip and knee osteoarthritis (OA), and to identify factors at enrolment to first-line intervention that are prognostic for progression to surgery.

Methods

In this longitudinal register-based observational study, we identified 72,069 patients with hip and knee OA in the Better Management of Patients with Osteoarthritis Register (BOA), who were referred for first-line OA intervention, between May 2008 and December 2016. Patients were followed until the first primary arthroplasty surgery before 31 December 2016, stratified into a hip and a knee OA cohort. Data were analyzed with Kaplan-Meier and multivariable-adjusted Cox regression.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 461 - 469
1 Apr 2019
Lädermann A Schwitzguebel AJ Edwards TB Godeneche A Favard L Walch G Sirveaux F Boileau P Gerber C

Aims. The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years. Patients and Methods. We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score. Results. From the original cohort, 29 shoulders (35%) were treated conservatively, 27 shoulders (32%) were revised by revision of the glenosphere, and 28 shoulders (33%) were converted to hemiarthroplasty. At last follow-up, conservative treatment and glenoid revision significantly improved AAE, total Constant score, and pain, while hemiarthroplasty did not improve range of movement or clinical scores. Multivariable analysis confirmed that conservative treatment and glenoid revision achieved similar improvements in pain (glenoid revision vs conservative, beta 0.44; p = 0.834) but that outcomes were significantly worse following hemiarthroplasty (beta -5.00; p = 0.029). Conclusion. When possible, glenoid loosening after RSA should first be treated conservatively, then by glenosphere revision if necessary, and last by salvage hemiarthroplasty. Cite this article: Bone Joint J 2019;101-B:461–469


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1625 - 1634
1 Dec 2016
Scott CEH Oliver WM MacDonald D Wade FA Moran M Breusch SJ

Aims. Risk of revision following total knee arthroplasty (TKA) is higher in patients under 55 years, but little data are reported regarding non-revision outcomes. This study aims to identify predictors of dissatisfaction in these patients. Patients and Methods. We prospectively assessed 177 TKAs (157 consecutive patients, 99 women, mean age 50 years; 17 to 54) from 2008 to 2013. Age, gender, implant, indication, body mass index (BMI), social deprivation, range of movement, Kellgren-Lawrence (KL) grade of osteoarthritis (OA) and prior knee surgery were recorded. Pre- and post-operative Oxford Knee Score (OKS) as well as Short Form-12 physical (PCS) and mental component scores were obtained. Post-operative range of movement, complications and satisfaction were measured at one year. Results . Overall, 44 patients with 44 TKAs (24.9%) under 55 years of age were unsure or dissatisfied with their knee. Significant predictors of dissatisfaction on univariate analysis included: KL grade 1/2 OA (59% dissatisfied), poor pre-operative OKS, complications, poor improvements in PCS and OKS and indication (primary OA 19% dissatisfied, previous meniscectomy 41%, multiply operated 42%, other surgery 29%, BMI > 40 kg/m. 2. 31%, post-traumatic OA 45%, and inflammatory arthropathy 5%). Poor pre-operative OKS, poor improvement in OKS and post-operative stiffness independently predicted dissatisfaction on multivariate analysis. Conclusion. Patients receiving TKA younger than 55 years old should be informed about the increased risks of dissatisfaction. Offering TKA in KL 1/2 is questionable, with a dissatisfaction rate of 59%. Cite this article: Bone Joint J 2016;98-B:1625–34


Bone & Joint Open
Vol. 3, Issue 8 | Pages 623 - 627
8 Aug 2022
Francis JL Battle JM Hardman J Anakwe RE

Aims

Fractures of the distal radius are common, and form a considerable proportion of the trauma workload. We conducted a study to examine the patterns of injury and treatment for adult patients presenting with distal radius fractures to a major trauma centre serving an urban population.

Methods

We undertook a retrospective cohort study to identify all patients treated at our major trauma centre for a distal radius fracture between 1 June 2018 and 1 May 2021. We reviewed the medical records and imaging for each patient to examine patterns of injury and treatment. We undertook a binomial logistic regression to produce a predictive model for operative fixation or inpatient admission.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims. The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients. Patients and Methods. We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH). Results. The mean forward elevation in the LP and FA groups was 125.3° (. sd. 21.4) and 148.9° (. sd. 19.8), respectively (p = 0.042), while other clinical factors showed no statistically significant differences between the groups. The changes in NSA and HHH immediately after the operation and at final follow-up were significantly better in the FA group than in the LP group (p = 0.015 and p = 0.021, respectively). Conclusion. For comminuted proximal humeral fractures in osteoporotic patients, locking plate fixation with a fibular strut allograft shows satisfactory short-term results with respect to humeral head support and maintenance of reduction, and may reduce the incidence of complications associated with fixation using a locking plate alone. Cite this article: Bone Joint J 2019;101-B:260–265


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 622 - 627
1 May 2016
Donaldson JR Tudor F Gollish J

Aims. The aim of this study was to examine the results of revision total knee arthroplasty (TKA) undertaken for stiffness in the absence of sepsis or loosening. Patients and Methods. We present the results of revision surgery for stiff TKA in 48 cases (35 (72.9%) women and 13 (27.1%) men). The mean age at revision surgery was 65.5 years (42 to 83). All surgeries were performed by a single surgeon. Stiffness was defined as an arc of flexion of < 70° or a flexion contracture of > 15°. The changes in the range of movement (ROM) and the Western Ontario and McMasters Osteoarthritis index scores (WOMAC) were recorded. Results. At a mean follow up of 59.9 months (12 to 272) there was a mean improvement in arc of movement of 45.0°. Mean flexion improved from 54.4° (5° to 100°) to 90° (10° to 125°) (p <  0.05) and the mean flexion contracture decreased from 12.0° (0° to 45°) to 3.5° (0° to 25°) (p < 0.05). The mean WOMAC scores improved for pain, stiffness and function. In patients with extreme stiffness we describe a novel technique, which we have called the ‘sloppy’ revision. This entails downsizing the polyethylene insert by 4 mm and using a more constrained liner to retain stability. Conclusion. To our knowledge, this is the largest series of revision surgeries for stiffness reported in the literature where infection and loosening have been excluded. . Take home message: Whilst revision surgery is technically demanding, improvements in ROM and outcome can be achieved, particularly when the revision is within two years of the primary surgery. Cite this article: Bone Joint J 2016;98-B:622–7


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 77 - 83
1 Jul 2019
James EW Blevins JL Gausden EB Turcan S Denova TA Satalich JR Ranawat AS Warren RF Ranawat AS

Aims. Anterior cruciate ligament (ACL) and multiligament knee (MLK) injuries increase the risk of development of knee osteoarthritis and eventual need for total knee arthroplasty (TKA). There are limited data regarding implant use and outcomes in these patients. The aim of this study was to compare the use of constrained implants and outcomes among patients undergoing TKA with a history of prior knee ligament reconstruction (PKLR) versus a matched cohort of patients undergoing TKA with no history of PKLR. Patients and Methods. Patients with a history of ACL or MLK reconstruction who underwent TKA between 2007 and 2017 were identified in a single-institution registry. There were 223 patients who met inclusion criteria (188 ACL reconstruction patients, 35 MLK reconstruction patients). A matched cohort, also of 223 patients, was identified based on patient age, body mass index (BMI), sex, and year of surgery. There were 144 male patients and 79 female patients in both cohorts. Mean age at the time of TKA was 57.2 years (31 to 88). Mean BMI was 29.7 kg/m. 2. (19.5 to 55.7). Results. There was a significantly higher use of constrained implants among patients with PKLR (76 of 223, 34.1%) compared with the control group (40 of 223, 17.9%; p < 0.001). Subgroup analysis showed a higher use of constrained implants among patients with prior MLK reconstruction (21 of 35, 60.0%) compared with ACL reconstruction (55 of 188, 29.3%; p < 0.001). Removal of hardware was performed in 69.5% of patients with PKLR. Mean operative time (p < 0.001) and tourniquet time (p < 0.001) were longer in patients with PKLR compared with controls. There were no significant differences in rates of deep vein thrombosis, pulmonary embolism, infection, transfusion, postoperative knee range of movement (ROM), or need for revision surgery. There was no significant difference in preoperative or postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR) scores between groups. Conclusion. Results of this study suggest a history of PKLR results in increased use of constrained implants but no difference in postoperative knee ROM, patient-reported outcomes, or incidence of revision surgery. Cite this article: Bone Joint J 2019;101-B(7 Supple C):77–83


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1182 - 1186
1 Sep 2018
Werner BS Chaoui J Walch G

Aims. Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods. Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results. Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion. Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6


Bone & Joint Research
Vol. 11, Issue 8 | Pages 585 - 593
1 Aug 2022
Graham SM Jalal MMK Lalloo DG Hamish R. W. Simpson A

Aims

A number of anti-retroviral therapies (ART) have been implicated in potentially contributing to HIV-associated bone disease. The aim of this study was to evaluate the effect of combination ART on the fracture healing process.

Methods

A total of 16 adult male Wistar rats were randomly divided into two groups (n = eight each): Group 1 was given a combination of Tenfovir 30 mg, Lamivudine 30 mg, and Efavirenz 60 mg per day orally, whereas Group 2 was used as a control. After one week of medication preload, all rats underwent a standardized surgical procedure of mid-shaft tibial osteotomy fixed by intramedullary nail with no gap at the fracture site. Progress in fracture healing was monitored regularly for eight weeks. Further evaluations were carried out after euthanasia by micro-CT, mechanically and histologically. Two blinded orthopaedic surgeons used the Radiological Union Scoring system for the Tibia (RUST) to determine fracture healing.


Bone & Joint Research
Vol. 8, Issue 1 | Pages 19 - 31
1 Jan 2019
Li M Zhang C Yang Y

Objectives. Many in vitro studies have investigated the mechanism by which mechanical signals are transduced into biological signals that regulate bone homeostasis via periodontal ligament fibroblasts during orthodontic treatment, but the results have not been systematically reviewed. This review aims to do this, considering the parameters of various in vitro mechanical loading approaches and their effects on osteogenic and osteoclastogenic properties of periodontal ligament fibroblasts. Methods. Specific keywords were used to search electronic databases (EMBASE, PubMed, and Web of Science) for English-language literature published between 1995 and 2017. Results. A total of 26 studies from the 555 articles obtained via the database search were ultimately included, and four main types of biomechanical approach were identified. Compressive force is characterized by static and continuous application, whereas tensile force is mainly cyclic. Only nine studies investigated the mechanisms by which periodontal ligament fibroblasts transduce mechanical stimulus. The studies provided evidence from in vitro mechanical loading regimens that periodontal ligament fibroblasts play a unique and dominant role in the regulation of bone remodelling during orthodontic tooth movement. Conclusion. Evidence from the reviewed studies described the characteristics of periodontal ligament fibroblasts exposed to mechanical force. This is expected to benefit subsequent research into periodontal ligament fibroblasts and to provide indirectly evidence-based insights regarding orthodontic treatment. Further studies should be performed to explore the effects of static tension on cytomechanical properties, better techniques for static compressive force loading, and deeper analysis of underlying regulatory systems. Cite this article: M. Li, C. Zhang, Y. Yang. Effects of mechanical forces on osteogenesis and osteoclastogenesis in human periodontal ligament fibroblasts: A systematic review of in vitro studies. Bone Joint Res 2019;8:19–31. DOI: 10.1302/2046-3758.81.BJR-2018-0060.R1


Bone & Joint Research
Vol. 11, Issue 8 | Pages 594 - 607
17 Aug 2022
Zhou Y Li J Xu F Ji E Wang C Pan Z

Aims

Osteoarthritis (OA) is a common degenerative joint disease characterized by chronic inflammatory articular cartilage degradation. Long noncoding RNAs (lncRNAs) have been previously indicated to play an important role in inflammation-related diseases. Herein, the current study set out to explore the involvement of lncRNA H19 in OA.

Methods

Firstly, OA mouse models and interleukin (IL)-1β-induced mouse chondrocytes were established. Expression patterns of IL-38 were determined in the synovial fluid and cartilage tissues from OA patients. Furthermore, the targeting relationship between lncRNA H19, tumour protein p53 (TP53), and IL-38 was determined by means of dual-luciferase reporter gene, chromatin immunoprecipitation, and RNA immunoprecipitation assays. Subsequent to gain- and loss-of-function assays, the levels of cartilage damage and proinflammatory factors were further detected using safranin O-fast green staining and enzyme-linked immunosorbent assay (ELISA) in vivo, respectively, while chondrocyte apoptosis was measured using Terminal deoxynucleotidyl transferase dUTP Nick-End Labeling (TUNEL) in vitro.


Bone & Joint 360
Vol. 11, Issue 4 | Pages 21 - 25
1 Aug 2022


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 60 - 63
1 Jan 2016
Ko LM Hozack WJ

Dual mobility cups have two points of articulation, one between the shell and the polyethylene (external bearing) and one between the polyethylene and the femoral head (internal bearing). Movement occurs at the inner bearing; the outer bearing only moves at extremes of movement. Dislocation after total hip arthroplasty (THA) is a cause of much morbidity and its treatment has significant cost implications. Dual mobility cups provide an increased range of movement and a may reduce the risk of dislocation. . This paper reviews the use of these cups in THA, particularly where stability is an issue. Dual mobility cups may be of benefit in primary THA in patients at a high risk of dislocation, such as those who are older with increased comorbidities and a higher American Association of Anesthesiology grade and those with a neuromuscular disease. They may be used at revision surgery where the risk of dislocation is high, such as in patients with many prior dislocations, or those with abductor deficiency. They may also be used in THA for displaced fractures of the femoral neck, which has a notoriously high rate of dislocation. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):60–3


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 59 - 65
1 Jan 2019
Katchky AM Jones CW Walter WL Shimmin AJ

Aims. Between 15% and 20% of patients remain dissatisfied following total knee arthroplasty (TKA). The SAIPH knee system (MatOrtho, Surrey, United Kingdom) is a medial ball and socket TKA that has been designed to replicate native knee kinematics in order to maximize the range of movement, stability, and function. This system is being progressively introduced in a stepwise fashion, with this study reporting the mid-term clinical and radiological outcomes. Patients and Methods. A retrospective review was undertaken of the first 100 consecutive patients with five-year follow-up following SAIPH TKA performed by the senior authors. The data that were collected included the demographics of the patients, clinical findings, the rate of intraoperative ligamentous release, patient-reported outcome measures (PROMS), radiological assessment, complications, and all-cause revision. Revision data were cross-checked with a national registry. Results. A total of 100 TKAs in 92 patients were included. Three patients died (three TKAs) and a further two TKAs were revised. Of the remaining 95 TKAs, five-year follow-up data were available for 81 TKAs (85%) in 87 patients. There were significant improvements in all PROMs and high satisfaction. The mean ROM at final follow-up was from 0° (full extension) to 124° flexion. There were seven major complications (7%): one infection, two deep vein thromboses, one cerebrovascular event, and two patients with stiffness requiring a manipulation under anaesthesia. Two patients required a lateral retinacular release to optimize patellar tracking in valgus knees; no additional ligament releases were performed in any patient. Radiological analysis demonstrated no evidence of implant-related complications. Conclusion. These results demonstrate satisfactory clinical and radiological outcomes at five years following a medial ball and socket TKA. The complication and revision rates are consistent with those previously reported for patients undergoing TKA. These results demonstrate the safety and efficacy of the SAIPH Knee TKA system and support its wider use


Bone & Joint Research
Vol. 11, Issue 7 | Pages 503 - 512
25 Jul 2022
Wu Y Shao Y Xie D Pan J Chen H Yao J Liang J Ke H Cai D Zeng C

Aims

To verify whether secretory leucocyte protease inhibitor (SLPI) can promote early tendon-to-bone healing after anterior cruciate ligament (ACL) reconstruction.

Methods

In vitro: the mobility of the rat bone mesenchymal stem cells (BMSCs) treated with SLPI was evaluated by scratch assay. Then the expression levels of osteogenic differentiation-related genes were analyzed by real-time quantitative PCR (qPCR) to determine the osteogenic effect of SLPI on BMSCs. In vivo: a rat model of ACL reconstruction was used to verify the effect of SLPI on tendon-to-bone healing. All the animals of the SLPI group and the negative control (NC) group were euthanized for histological evaluation, micro-CT scanning, and biomechanical testing.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 565 - 572
1 May 2019
Teeter MG Marsh JD Howard JL Yuan X Vasarhelyi EM McCalden RW Naudie DDR

Aims. The purpose of the present study was to compare patient-specific instrumentation (PSI) and conventional surgical instrumentation (CSI) for total knee arthroplasty (TKA) in terms of early implant migration, alignment, surgical resources, patient outcomes, and costs. . Patients and Methods. The study was a prospective, randomized controlled trial of 50 patients undergoing TKA. There were 25 patients in each of the PSI and CSI groups. There were 12 male patients in the PSI group and seven male patients in the CSI group. The patients had a mean age of 69.0 years (. sd. 8.4) in the PSI group and 69.4 years (. sd. 8.4) in the CSI group. All patients received the same TKA implant. Intraoperative surgical resources and any surgical waste generated were recorded. Patients underwent radiostereometric analysis (RSA) studies to measure femoral and tibial component migration over two years. Outcome measures were recorded pre- and postoperatively. Overall costs were calculated for each group. Results. There were no differences (p > 0.05) in any measurement of migration at two years for either the tibial or femoral components. Movement between one and two years was < 0.2 mm, indicating stable fixation. There were no differences in coronal or sagittal alignment between the two groups. The PSI group took a mean 6.1 minutes longer (p = 0.04) and used a mean 3.4 less trays (p < 0.0001). Total waste generated was similar (10 kg) between the two groups. The PSI group cost a mean CAD$1787 more per case (p < 0.01). Conclusion. RSA criteria suggest that both groups will have revision rates of approximately 3% at five years. The advantages of PSI were minimal or absent for surgical resources used and waste eliminated, and for meeting target alignment, yet had significantly greater costs. Therefore, we conclude that PSI may not offer any advantage over CSI for routine primary TKA cases. Cite this article: Bone Joint J 2019;101-B:565–572


Bone & Joint Open
Vol. 3, Issue 5 | Pages 359 - 366
1 May 2022
Sadekar V Watts AT Moulder E Souroullas P Hadland Y Barron E Muir R Sharma HK

Aims

The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors.

Methods

We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture.


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 715 - 723
1 Jun 2019
Jayakumar P Teunis T Williams M Lamb SE Ring D Gwilym S

Aims. The purpose of this study was to identify factors associated with limitations in function, measured by patient-reported outcome measures (PROMs), six to nine months after a proximal humeral fracture, from a range of demographic, injury, psychological, and social variables measured within a week and two to four weeks after injury. Patients and Methods. We enrolled 177 adult patients who sustained an isolated proximal humeral fracture into the study and invited them to complete PROMs at their initial outpatient visit within one week of injury, between two and four weeks, and between six to nine months after injury. There were 128 women and 49 men; the mean age was 66 years (. sd. 16; 18 to 95). In all, 173 patients completed the final assessment. Bivariate analysis was performed followed by multivariable regression analysis accounting for multicollinearity using partial R. 2. , correlation matrices, and variable inflation factor. Results. Many variables within a week of injury and between two and four weeks after injury correlated with six- to nine-month PROMs in bivariate analysis. Kinesiophobia measured within a week of injury (Tampa Scale for Kinesiophobia-11: partial R. 2. = 0.14; p = 0.000) and self-efficacy measured between two and four weeks (Pain Self-efficacy Questionnaire-2: partial R. 2. = 0.266; p < 0.001) were the strongest predictors of limitations (measured by Patient Reported Outcome Measurement Information System Upper Extremity Physical Function Computer Adaptive Test (PROMIS UE)) at six to nine months in multivariable analysis. Similar findings were observed with other types of PROM. Regression models accounted for a substantial amount of variance in all PROMs at both timepoints (e.g. 66% of the overall variance within one week, and 70% within two to four weeks for PROMIS UE at six to nine months). . Conclusion. Recovery from a proximal humeral fracture appears to be enhanced by overcoming fears of movement or reinjury within a week after injury and greater self-efficacy (developing resilience and more effective coping strategies) within a month. Such factors are modifiable using enhanced communication skills and cognitive behavioural treatments. These findings could be a catalyst for the routine assessment and treatment of psychological and social factors in the management of patients with fractures. Cite this article: Bone Joint J 2019;101-B:715–723


Bone & Joint Research
Vol. 7, Issue 12 | Pages 639 - 649
1 Dec 2018
MacLeod AR Serrancoli G Fregly BJ Toms AD Gill HS

Objectives. Opening wedge high tibial osteotomy (HTO) is an established surgical procedure for the treatment of early-stage knee arthritis. Other than infection, the majority of complications are related to mechanical factors – in particular, stimulation of healing at the osteotomy site. This study used finite element (FE) analysis to investigate the effect of plate design and bridging span on interfragmentary movement (IFM) and the influence of fracture healing on plate stress and potential failure. Materials and Methods. A 10° opening wedge HTO was created in a composite tibia. Imaging and strain gauge data were used to create and validate FE models. Models of an intact tibia and a tibia implanted with a custom HTO plate using two different bridging spans were validated against experimental data. Physiological muscle forces and different stages of osteotomy gap healing simulating up to six weeks postoperatively were then incorporated. Predictions of plate stress and IFM for the custom plate were compared against predictions for an industry standard plate (TomoFix). Results. For both plate types, long spans increased IFM but did not substantially alter peak plate stress. The custom plate increased axial and shear IFM values by up to 24% and 47%, respectively, compared with the TomoFix. In all cases, a callus stiffness of 528 MPa was required to reduce plate stress below the fatigue strength of titanium alloy. Conclusion. We demonstrate that larger bridging spans in opening wedge HTO increase IFM without substantially increasing plate stress. The results indicate, however, that callus healing is required to prevent fatigue failure. Cite this article: A. R. MacLeod, G. Serrancoli, B. J. Fregly, A. D. Toms, H. S. Gill. The effect of plate design, bridging span, and fracture healing on the performance of high tibial osteotomy plates: An experimental and finite element study. Bone Joint Res 2018;7:639–649. DOI: 10.1302/2046-3758.712.BJR-2018-0035.R1


Bone & Joint Research
Vol. 11, Issue 7 | Pages 465 - 476
13 Jul 2022
Li MCM Chow SK Wong RMY Chen B Cheng JCY Qin L Cheung W

Aims

There is an increasing concern of osteoporotic fractures in the ageing population. Low-magnitude high-frequency vibration (LMHFV) was shown to significantly enhance osteoporotic fracture healing through alteration of osteocyte lacuno-canalicular network (LCN). Dentin matrix protein 1 (DMP1) in osteocytes is known to be responsible for maintaining the LCN and mineralization. This study aimed to investigate the role of osteocyte-specific DMP1 during osteoporotic fracture healing augmented by LMHFV.

Methods

A metaphyseal fracture was created in the distal femur of ovariectomy-induced osteoporotic Sprague Dawley rats. Rats were randomized to five different groups: 1) DMP1 knockdown (KD), 2) DMP1 KD + vibration (VT), 3) Scramble + VT, 4) VT, and 5) control (CT), where KD was performed by injection of short hairpin RNA (shRNA) into marrow cavity; vibration treatment was conducted at 35 Hz, 0.3 g; 20 minutes/day, five days/week). Assessments included radiography, micro-CT, dynamic histomorphometry and immunohistochemistry on DMP1, sclerostin, E11, and fibroblast growth factor 23 (FGF23). In vitro, murine long bone osteocyte-Y4 (MLO-Y4) osteocyte-like cells were randomized as in vivo groupings. DMP1 KD was performed by transfecting cells with shRNA plasmid. Assessments included immunocytochemistry on osteocyte-specific markers as above, and mineralized nodule staining.