Advertisement for orthosearch.org.uk
Results 281 - 300 of 694
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 453 - 454
1 May 1993
Proctor M Moore D Paterson J

We reviewed 68 fractures of the distal radius in children, all treated by primary manipulation and plaster immobilisation. Complete displacement of the fracture and failure to achieve a perfect reduction were both associated with a significant increase in the chance of redisplacement. We recommend the use of percutaneous Kirschner wires to maintain a satisfactory position in all cases in which a perfect reduction cannot be achieved


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 107 - 109
1 Jan 1995
Moens P Lammens J Molenaers G Fabry G

We describe a technique of femoral derotation osteotomy performed according to the Ilizarov principles of percutaneous corticotomy and fixation with a frame. We performed 24 femoral osteotomies in 16 patients, four with cerebral palsy and 12 with idiopathic femoral anteversion. All had rapid union and there were few complications. The advantages of the method include early ambulation, good control of rotation and axial alignment, and minimal scarring


Bone & Joint 360
Vol. 9, Issue 4 | Pages 41 - 44
1 Aug 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 458 - 460
1 May 1996
Haddad FS Prendergast CM Dorrell JH Platts AD

We present a patient with an arteriovenous fistula of the peroneal artery acquired after a left dome tibial osteotomy with midshaft fibular osteotomy. He had subsequently had a total knee replacement on that side. The arteriovenous malformation was only diagnosed when he represented with symptoms and signs of venous hypertension with sterile recurrent haemarthroses in the left knee. Percutaneous obliteration of the fistula, by a combination of coil embolisation and balloon occlusion, cured the symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 791 - 796
1 Sep 1995
Templeton P Graham H

During a six-year period we prospectively studied eight children who presented with supracondylar fractures of the humerus and of the forearm on the same side. They were treated by prompt closed reduction, percutaneous fixation with Kirschner wires, and appropriate management of neurovascular and soft-tissue injuries. The results were assessed clinically and radiographically at a minimum of 12 months after injury. According to a clinical scoring system they were acceptable in seven children and poor in one


Bone & Joint 360
Vol. 9, Issue 4 | Pages 26 - 30
1 Aug 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 886 - 888
1 Sep 1990
Pennig D Brug E

Posterior spinal instrumentation with the placement of intrapedicular implants has become an important technique. We have designed a hand-held target device to facilitate the open or percutaneous location and penetration of the thoracolumbar pedicles. A cylindrical pin guide incorporates two metal rings and can be moved under image intensifier control until the rings are superimposed to show correct alignment. The radiation dosage for the surgeon is minimal; the device allowed accurate placement of 106 consecutive pedicle screws


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1321 - 1324
1 Nov 2019
Kerr S Warwick D Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 651 - 656
1 Aug 1989
Jones C Dewar M Aichroth P Crawfurd E Emery R

Ten epiphyses in seven children underwent fixed-rate distraction of 0.25 mm twice daily in an attempt to achieve percutaneous leg lengthening by chondrodiatasis. The forces generated across the growth plate were recorded by means of strain gauges incorporated into the distractors. All epiphyses fractured before 33 days of lengthening. An average gain of 6.75 cm was achieved. Epiphyseal distraction at the lower femur produced many complications, but at the upper tibial epiphysis planned lengthening was achieved, with excellent bone production and few complications


Bone & Joint 360
Vol. 9, Issue 1 | Pages 35 - 39
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 612 - 614
1 Jul 1990
Majeed S

External fixation was used in 42 patients as the sole definitive treatment for their unstable pelvic fractures. At an average follow-up of 40 months, the anatomical outcome was related to the functional outcome using defined criteria. The functional results were better than the anatomical results. Function improved during the first 18 months and thereafter was stable. The stab and percutaneous techniques for pin insertion had lower rates of infection than the incisional technique. External fixation has a definite role in the treatment of unstable pelvic fractures. In contrast to internal fixation, this method has two major advantages: safety and simplicity


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 647 - 651
1 Jul 1996
Arens S Schlegel U Printzen G Ziegler WJ Perren SM Hansis M

Resistance to infection may be influenced by foreign bodies such as devices for fracture fixation. It is known that stainless steel and commercially-pure titanium have different biocompatibilities. We have investigated susceptibility to infection after a local bacterial challenge using standard 2.0 dynamic compression plates of either stainless steel or titanium in rabbit tibiae. After the wounds had been closed, various concentrations of a strain of Staphylococcus aureus were inoculated percutaneously. Under otherwise identical experimental conditions the rate of infection for steel plates (75%) was significantly higher than that for titanium plates (35%) (p < 0.05)


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 954 - 957
1 Sep 2004
Metaizeau J

Fractures of the femur are the most incapacitating fractures in children. Conservative treatment necessitates a long stay in hospital for traction and subsequent immobilisation in an uncomfortable cast. This treatment is not well tolerated, especially in adolescents. Moreover, near the end of growth, accurate reduction is necessary, as malunion is no longer correctable by growth. Stable elastic intramedullary nailing uses two flexible nails which are introduced percutaneously either through the lower metaphysis or the subtrochanteric area. This technique does not disturb the healing of the fracture. The elasticity of the device allows slight movement at the fracture site which favours union. Reduction and stabilisation are adequate and the operative risk is very low. A cast is not required, functional recovery is rapid and the patient is allowed to walk with crutches after seven to ten days according to the type of fracture. This technique is very efficient in adolescents and can be used after the age of seven years when conservative treatment is unsuccessful


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 734 - 737
1 Sep 1997
Guichet J Moller C Dautel G Lascombes P

Anteriorly displaced fractures of the wrist can be treated by the Kapandji technique of percutaneous intrafocal pinning with pins inserted through an anterior approach to give good reduction and stabilisation of the fracture. We have modified this technique by placing the pins through a posterior approach which decreases the risks of neurovascular damage. We have used this method to treat six children with distal radial fractures showing anterior displacement or instability. Good anterior stabilisation was achieved. The pins were removed at an average of eight weeks and the patients were then able to return to full activity. This simple technique can be used for unstable fractures after the failure of conservative treatment or in bilateral fractures in adolescents


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 307 - 309
1 Mar 1997
Macnicol MF Gupta MS

A technique for epiphysiodesis using a cannulated tubesaw has been developed to combine the precision of the original Phemister method with newer percutaneous methods. The approach is unilateral, and requires minimal access. Reinsertion of the removed core of bone reduces haemorrhage from the defect and augments arrest of the growth plate. In 35 patients treated by this method predicted discrepancies of 2 to 4.5 cm were reliably reduced to 0.7 ± 0.6 cm, with no serious complications. The timing of surgery is critical, and relies upon careful monitoring of the pattern of discrepancy over several years, using clinical and radiographic measurements. Undercorrection of the disparity in three patients was the direct result of late referral


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 413 - 425
1 Apr 2004
Edelson G Kelly I Vigder F Reis ND

Existing classifications of fractures of the head of the humerus are inadequate in terms of interobserver reliability and the predictability of the clinical outcome. From a combined study of 73 fracture specimens in museums and 84 CT-three-dimensional reconstructions in patients, we have devised a classification which appears to be more useful clinically. Common patterns of fracture and a plausible mechanism of injury were observed. In 3-D most proximal humeral fractures can be organised into five basic types. These correspond in some degree to the Codman/Neer classification, but differ significantly in regard to the more complex patterns of fracture. We observed a logical progression from simple to complex fractures. An interobserver reliability study was carried out which indicated the improved usefulness of this new 3-D concept in providing a common language among clinicians for classifying these injuries. When surgery is indicated, the 3-D concept is also invaluable in guiding the restitution of anatomy through either open or percutaneous means


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 391 - 395
1 May 1984
Panting A Lamb D Noble J Haw C

A review of 61 patients with dislocation of the lunate (some with and some without fracture of the scaphoid) showed that the majority had satisfactory results at an average follow-up of three and a half years. Most patients with a simple dislocation had a good or satisfactory result; radiological instability was noted in a quarter of the wrists but was not often associated with symptoms. Two-thirds of the patients with an associated fracture of the scaphoid had a good or satisfactory result. Immediate percutaneous wire fixation of the reduced scaphoid, whether it is fractured or not, is the best way of maintaining normal anatomical relationship while the ligaments and fracture heal; this may further improve the prognosis. In most cases extreme dorsiflexion of the wrist appeared to be the mechanism of injury


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 691 - 699
1 Jul 2003
Ali AM Burton M Hashmi M Saleh M

Fine-wire accepted as a minimally external fixation is invasive technique, which can provide better outcomes than traditional open methods in the management of complex fractures of the tibial plateau. Available fixators vary in their biomechanical stability, and we believe that a stable beam-loading system is essential for consistently good outcomes. We assessed, prospectively, the clinical, radiological and general health status of 20 of 21 consecutive patients with complex fractures of the tibial plateau who had been treated using a standard protocol, with percutaneous screw fixation and a neutralisation concept with a fine wire beam-loading fixator allowing early weight-bearing. Bony union was achieved in all patients, with 85% having good or excellent results. Full weight-bearing started during the first six weeks in 60% of patients. The general health status assessment correlated well with the knee scores and reflected a satisfactory outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 143 - 146
1 Jan 1991
de Jager L Hoffman E

We have reviewed 12 cases of fracture-separation of the distal humeral epiphysis, three of which were initially misdiagnosed as fractures of the lateral condyle and one as an elbow dislocation. Cubitus varus deformity is as common after this fracture-separation as it is following supracondylar fracture, and is most common in children under two years of age. Closed reduction and simple immobilisation is adequate for the older child, but we recommend for those under two years of age that closed reduction should be followed by percutaneous pinning, so that the carrying angle can be assessed immediately after reduction. If the elbow is then in varus the wires should be removed, reduction repeated and treatment by straight lateral traction used to maintain a valgus carrying angle


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 383 - 386
1 Aug 1978
Soltanpur A

The management of an anterior supracondylar fracture by closed reduction, traction, percutaneous pinning or open reduction is seldom satisfactory, especially for adults and the aged with a lesser ability to remodel and a slower functional recovery. A new, safe, and simple technique is described in which the condylar mass is pushed posteriorly along the axis of the forearm and the hand is rotated to full supination while the elbow is held in flexion to correct deformities. Fixation is divided into two parts: the circular cast around the upper arm provides a firm buttress onto which the lower fragment is reduced and then the arm is immobilised in a plaster which includes the wrist. Four cases of delayed, comminuted, compound fractures have been fully evaluated clinically and radiologically and the results assessed as good or excellent