Advertisement for orthosearch.org.uk
Results 281 - 300 of 841
Results per page:
Bone & Joint 360
Vol. 10, Issue 1 | Pages 38 - 41
1 Feb 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 3 | Pages 490 - 500
1 Aug 1974
Fowles JV Kassab MT

Displaced extension supracondylar fractures of the elbow 1. One hundred and ten children were treated by reduction and stabilisation by two pins inserted laterally at an angle of 30 degrees to one another. 2. The complications before and after treatment included fifteen nerve lesions in thirteen patients. The ulnar nerve was involved on one occasion only. Solitary radial nerve injuries occurred with postero-medial displacement of the distal fragment, while median nerve and brachial artery injuries were associated with postero-lateral displacement. All the lesions recovered spontaneously. 3. There were no ischaemic complications after treatment, despite the ligation of one ruptured brachial artery. 4. The average stay in hospital was four days, compared with twenty days for thirty-two other patients treated in traction because of gross oedema. 5. Of eighty patients seen six months to five years after the fracture, seventy (or 87·5 per cent) had excellent or good results, seven patients with marked varus deformities had fair results, and two patients had poor results with very stiff elbows. Displaced flexion fractures 1. The clinical features, complications and treatment of seventeen cases are described. 2. There were no complications involving the median or radial nerves or the brachial artery, but three patients had a lesion of the ulnar nerve. 3. Nine children had closed reduction and fixation by two lateral percutaneous pins. 4. Reduction was difficult and the results poor compared with extension fractures. Closed reduction failed in one-third of the children, and the functional and cosmetic results were unsatisfactory in over half the patients reviewed


Bone & Joint 360
Vol. 10, Issue 2 | Pages 43 - 47
1 Apr 2021


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 4 | Pages 664 - 676
1 Nov 1969
Pahle JA Raunio P

A study has been made of fifty-six patients suffering from rheumatoid arthritis in whom sixty-nine wrists were fused. The purpose of the investigation was to evaluate to what extent the position of the fused wrist influenced the position of the fingers in the frontal plane. All sixty-nine wrists were followed up by radiographic examination controls, and thirty-seven of the wrists were also examined clinically. The mean period of observation after operation was seven years and ten months. The findings support the so-called "zigzag" theory based on the concept of carpus-metacarpus acting as Landsmeer's intercalated bone in a bi-articular system. When the wrists were fused in more than 5 degrees of radial deviation seventeen of twenty hands showed ulnar drift of the fingers on radiographic examination. Of the nine patients in this group examined clinically, all showed ulnar drift. A strong tendency to correction of the finger position is seen when the hands are pressed against the cassette. For this reason the clinical examination, during which the finger deviation was examined with the metacarpo-phalangeal joints in 30 degrees of flexion regularly revealed an ulnar deviation of 5 degrees more than that shown by radiographic examination. In eighteen wrists the fusion had been done in more than 5 degrees of ulnar deviation. Fourteen of these hands showed a resulting radial deviation of the fingers on radiographic examination. In a group of thirty-one wrists fused in neutral position (0 degrees±5 degrees) only six hands showed more than 5 degrees of finger deviation to either side. The condition of the metacarpo-phalangeal joints asjudged from radiographs did not seem to influence the deviation of the fingers either in direction or in degree. The direction of the deviation of the fingers was almost regularly the opposite to that of the fused wrist. Five hands showing no visible pathological changes in the metacarpo-phalangeal joints displayed finger drift


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 53 - 58
1 Jul 2021
Lawrie CM Bechtold D Schwabe M Clohisy JC

Aims

The direct anterior approach (DAA) for total hip arthroplasty (THA) has potential advantages over other approaches and is most commonly performed with the patient in the supine position. We describe a technique for DAA THA with the patient in the lateral decubitus position and report the early clinical and radiological outcomes, the characteristics of the learning curve, and perioperative complications.

Methods

All primary DAA THAs performed in the lateral position by a single surgeon over a four-year period from the surgeon’s first case using the technique were identified from a prospectively collected database. Modified Harris Hip Scores (mHHS) were collected to assess clinical outcome, and routine radiological analysis was performed. Retrospective review of the medical records identified perioperative complications, the characteristics of the learning curve, and revisions.


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 746 - 754
1 Apr 2021
Schnetzke M El Barbari J Schüler S Swartman B Keil H Vetter S Gruetzner PA Franke J

Aims

Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation.

Methods

A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 142 - 145
1 Jan 2010
Spencer SJ Holt G Clarke JV Mohammed A Leach WJ Roberts JLB

The humerus is a common site for skeletal metastases in the adult. Surgical stabilisation of such lesions is often necessary to relieve pain and restore function. These procedures are essentially palliative and should therefore provide effective relief from pain for the remainder of the patient’s life without the need for further surgical intervention. We report a retrospective analysis of 35 patients (37 nails) with symptomatic metastases in the shaft of the humerus which were treated by locked, antegrade nailing. There were 27 true fractures (73.0%) and ten painful deposits (27.0%). Relief from pain was excellent in four (11.4%), good in 29 (82.9%) and fair in two (5.7%) on discharge. Function was improved in all but one patient. One case of palsy of the radial nerve was noted. The mean postoperative survival was 7.1 months (0.2 to 45.5) which emphasises the poor prognosis in this group of patients. There were no failures of fixation and no case in which further surgery was required. Antegrade intramedullary nailing is an effective means of stabilising the humerus for the palliative treatment of metastases. It relieves pain and restores function to the upper limb with low attendant morbidity


Bone & Joint Open
Vol. 2, Issue 3 | Pages 141 - 149
1 Mar 2021
Saab M Chick G

Aims

The objective of this systematic review was to describe trapeziectomy outcomes and complications in the context of osteoarthritis of the base of the thumb after a five-year minimum follow-up.

Methods

Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were used to guide study design, and 267 full-text articles were assessed for eligibility. After exclusion criteria application, 22 studies were included, involving 728 patients and 823 trapeziectomies. Outcomes included pre- and postoperative clinical and radiological characteristics. Complications and revisions were recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1545 - 1550
1 Nov 2007
Koslowsky TC Mader K Dargel J Koebke J Hellmich M Pennig D

We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability. A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure. The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N. A significantly better quality of reduction was achieved using the FFS wires (Tukey’s post hoc tests, p < 0.001) than with the other devices with a mean step in the articular surface and the radial neck of 1.04 mm (. sd. 0.96) for the FFS, 4.25 mm (. sd. 1.29) for the miniplates, 2.21 mm (. sd. 1.06) for the miniscrews and 2.54 mm (. sd. 0.98) for the K-wires. The quality of reduction was similar for K-wires and miniscrews, but poor for miniplates. The ultimate failure load was similar for the FFS wires (parallel, 196.8 N (. sd. 46.8), perpendicular, 212.5 N (. sd. 25.6)), miniscrews (parallel, 211.8 N (. sd. 47.9), perpendicular, 208.0 N (. sd. 65.9)) and K-wires (parallel, 200.4 N (. sd. 54.5), perpendicular, 165.2 N (. sd. 37.9)), but significantly worse (Tukey’s post hoc tests, p < 0.001) for the miniplates (parallel, 101.6 N (. sd. 43.1), perpendicular, 122.7 N (. sd. 40.7)). There was a significant difference in the displacement at 50 N for the miniplate (parallel, 4.8 mm (. sd. 2.8), perpendicular, 4.8 mm (. sd. 1.7)) vs FFS (parallel, 2.1 mm (. sd. 0.8), perpendicular, 1.9 mm (. sd. 0.7)), miniscrews (parallel, 1.8 mm (. sd. 0.5), perpendicular, 2.3 mm (. sd. 0.8)) and K-wires (parallel, 2.2 mm (. sd. 1.8), perpendicular, 2.4 mm (. sd. 0.7; Tukey’s post hoc tests, p < 0.001)). The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1608 - 1617
1 Dec 2020
Castioni D Mercurio M Fanelli D Cosentino O Gasparini G Galasso O

Aims

The aim of this systematic review and meta-analysis is to evaluate differences in functional outcomes and complications between single- (SI) and double-incision (DI) techniques for the treatment of distal biceps tendon rupture.

Methods

A comprehensive search on PubMed, MEDLINE, Scopus, and Cochrane Central databases was conducted to identify studies reporting comparative results of the SI versus the DI approach. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was used for search strategy. Of 606 titles, 13 studies met the inclusion criteria; methodological quality was assessed with the Newcastle-Ottawa scale. Random- and fixed-effects models were used to find differences in outcomes between the two surgical approaches. The range of motion (ROM) and the Disabilities of the Arm, Shoulder and Hand (DASH) scores, as well as neurological and non-neurological complications, were assessed.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1416 - 1421
1 Oct 2010
Qureshi F Draviaraj KP Stanley D

Between September 1993 and September 1996, we performed 34 Kudo 5 total elbow replacements in 31 rheumatoid patients. All 22 surviving patients were reviewed at a mean of 11.9 years (10 to 14). Their mean age was 56 years (37 to 78) at the time of operation. All had Larsen grade IV or V rheumatoid changes on X-ray. Nine (three bilateral replacements and six unilateral) had died from unrelated causes. One who had died before ten years underwent revision for dislocation. Of the 22 total elbow replacements reviewed six had required revision, four for aseptic loosening (one humeral and three ulnar) and two for infection. Post-operatively, one patient had neuropraxia of the ulnar nerve and one of the radial nerve. Two patients had valgus tilting of the ulnar component. With revision as the endpoint, the mean survival time for the prosthesis was 11.3 years (95% confidence interval (10 to 13) and the estimated survival of the prosthesis at 12 years according to Kaplan-Meier survival analysis was 74% (95% confidence interval 0.53 to 0.91). Of the 16 surviving implants, ten were free from pain, four had mild pain and two moderate. The mean arc of flexion/extension of the elbow was 106° (65° to 130°) with pronation/supination of 90° (30° to 150°) with the joint at 90° of flexion. The mean Mayo elbow performance score was 82 (60 to 100) with five excellent, ten good and one fair result. Good long-term results can be expected using the Kudo 5 total elbow replacement in patients with rheumatoid disease, with a low incidence of loosening of the components


Bone & Joint Open
Vol. 1, Issue 9 | Pages 576 - 584
18 Sep 2020
Sun Z Liu W Li J Fan C

Post-traumatic elbow stiffness is a disabling condition that remains challenging for upper limb surgeons. Open elbow arthrolysis is commonly used for the treatment of stiff elbow when conservative therapy has failed. Multiple questions commonly arise from surgeons who deal with this disease. These include whether the patient has post-traumatic stiff elbow, how to evaluate the problem, when surgery is appropriate, how to perform an excellent arthrolysis, what the optimal postoperative rehabilitation is, and how to prevent or reduce the incidence of complications. Following these questions, this review provides an update and overview of post-traumatic elbow stiffness with respect to the diagnosis, preoperative evaluation, arthrolysis strategies, postoperative rehabilitation, and prevention of complications, aiming to provide a complete diagnosis and treatment path.

Cite this article: Bone Joint Open 2020;1-9:576–584.


Bone & Joint 360
Vol. 10, Issue 2 | Pages 37 - 40
1 Apr 2021


Bone & Joint Research
Vol. 10, Issue 4 | Pages 269 - 276
1 Apr 2021
Matsubara N Nakasa T Ishikawa M Tamura T Adachi N

Aims

Meniscal injuries are common and often induce knee pain requiring surgical intervention. To develop effective strategies for meniscus regeneration, we hypothesized that a minced meniscus embedded in an atelocollagen gel, a firm gel-like material, may enhance meniscus regeneration through cell migration and proliferation in the gel. Hence, the objective of this study was to investigate cell migration and proliferation in atelocollagen gels seeded with autologous meniscus fragments in vitro and examine the therapeutic potential of this combination in an in vivo rabbit model of massive meniscus defect.

Methods

A total of 34 Japanese white rabbits (divided into defect and atelocollagen groups) were used to produce the massive meniscus defect model through a medial patellar approach. Cell migration and proliferation were evaluated using immunohistochemistry. Furthermore, histological evaluation of the sections was performed, and a modified Pauli’s scoring system was used for the quantitative evaluation of the regenerated meniscus.


Bone & Joint 360
Vol. 9, Issue 3 | Pages 26 - 29
1 Jun 2020


Bone & Joint 360
Vol. 10, Issue 2 | Pages 33 - 37
1 Apr 2021


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1405 - 1411
3 Oct 2020
Martynov I Klink T Slowik V Stich R Zimmermann P Engel C Lacher M Boehm R

Aims

This exploratory randomized controlled trial (RCT) aimed to determine the splint-related outcomes when using the novel biodegradable wood-composite splint (Woodcast) compared to standard synthetic fibreglass (Dynacast) for the immobilization of undisplaced upper limb fractures in children.

Methods

An exploratory RCT was performed at a tertiary paediatric referral hospital between 1 June 2018 and 30 September 2019. The intention-to-treat population consisted of 170 patients (mean age 8.42 years (SD 3.42); Woodcast (WCG), n = 84, 57 male (67.9%); Dynacast (DNG), n = 86, 58 male (67.4%)). Patients with undisplaced upper limb fractures were randomly assigned to WCG or DNG treatment groups. Primary outcome was the stress stability of the splint material, defined as absence of any deformations or fractures within the splint during study period. Secondary outcomes included patient satisfaction and medical staff opinion. Additionally, biomechanical and chemical analysis of the splint samples was carried out.


Bone & Joint 360
Vol. 9, Issue 4 | Pages 30 - 33
1 Aug 2020


Bone & Joint 360
Vol. 9, Issue 4 | Pages 26 - 30
1 Aug 2020


Bone & Joint Research
Vol. 9, Issue 7 | Pages 429 - 439
1 Jul 2020
Tahir M Chaudhry EA Zaffar Z Anwar K Mamoon MAH Ahmad M Jamali AR Mehboob G

Aims

We hypothesized that the wide-awake local anaesthesia with no tourniquet (WALANT) technique is cost-effective, easy to use, safe, and reproducible, with a low learning curve towards mastery, having a high patient satisfaction rate. Furthermore, WALANT would be a suitable alternative for the austere and developing nation environments where lack of funds and resources are a common issue.

Methods

This was a randomized control trial of 169 patients who required surgery for closed isolated distal radius fractures. The study was performed between March 2016 and April 2019 at a public sector level 1 trauma centre. General anaesthesia was used in 56 patients, Bier’s block in 58 patients, and WALANT in 55 patients. Data were collected on pre-, peri-, and postoperative parameters, clinical outcome, hospital costs, and patient satisfaction. One-way analysis of variance (ANOVA) was used with a p-value of 0.05 being significant.