Aims. Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques. Methods. Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S. 4. ). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads. Results. Experimental pull-out strengths were excellently correlated to the µFE pull-out stiffness of the ROI (R. 2. > 0.87) and FV (R. 2. > 0.84) models. No significant difference due to screw design was observed. Cement augmentation increased pull-out stiffness by up to 94% and 48% for L and R screws, respectively, but only increased bending stiffness by up to 6.9% and 1.5%, respectively. Cementing involving only one screw tip resulted in lower stiffness increases in all tested screw designs and loading cases. The stiffening effect of cement augmentation on pull-out and bending stiffness was strongly and negatively correlated to local bone density around the screw (correlation coefficient (R) = -0.95). Conclusion. This combined experimental, µCT and µFE study showed that regional analyses may be sufficient to
Aims. The early mortality in patients with hip fractures from bony metastases is unknown. The objectives of this study were to quantify 30- and 90-day mortality in patients with proximal femoral metastases, and to create a mortality prediction tool based on biomarkers associated with early death. Methods. This was a retrospective cohort study of consecutive patients referred to the orthopaedic department at a UK trauma centre with a proximal femoral metastasis (PFM) over a seven-year period (2010 to 2016). The study group were compared to a matched control group of non-metastatic hip fractures. Minimum follow-up was one year. Results. There was a 90-day mortality of 46% in patients with metastatic hip fractures versus 12% in controls (89/195 and 24/192, respectively; p < 0.001). Mean time to surgery was longer in symptomatic metastases versus complete fractures (9.5 days (SD 19.8) and 3.4 days (SD 11.4), respectively; p < 0.05). Albumin, urea, and corrected calcium were all independent
Aims. In computer simulations, the shape of the range of motion (ROM) of a stem with a cylindrical neck design will be a perfect cone. However, many modern stems have rectangular/oval-shaped necks. We hypothesized that the rectangular/oval stem neck will affect the shape of the ROM and the prosthetic impingement. Methods. Total hip arthroplasty (THA) motion while standing and sitting was simulated using a MATLAB model (one stem with a cylindrical neck and one stem with a rectangular neck). The primary
Aims. Fungal and mycobacterial periprosthetic joint infections (PJI) are rare events. Clinicians are wary of missing these diagnoses, often leading to the routine ordering of fungal and mycobacterial cultures on periprosthetic specimens. Our goal was to examine the utility of these cultures and explore a modern bacterial culture technique using bacterial blood culture bottles (BCBs) as an alternative. Methods. We performed a retrospective review of patients diagnosed with hip or knee PJI between 1 January 2010 and 31 December 2019, at the Mayo Clinic in Rochester, Minnesota, USA. We included patients aged 18 years or older who had fungal, mycobacterial, or both cultures performed together with bacterial cultures. Cases with positive fungal or mycobacterial cultures were reviewed using the electronic medical record to classify the microbiological findings as representing true infection or not. Results. There were 2,067 episodes of PJI diagnosed within the study period. A total of 3,629 fungal cultures and 2,923 mycobacterial cultures were performed, with at least one of these performed in 56% of episodes (n = 1,157). Test positivity rates of fungal and mycobacterial cultures were 5% (n = 179) and 1.2% (n = 34), respectively. After a comprehensive review, there were 40 true fungal and eight true mycobacterial PJIs. BCB were 90% sensitive in diagnosing true fungal PJI and 100% sensitive in detecting rapidly growing mycobacteria (RGM). Fungal stains were performed in 27 true fungal PJI but were only positive in four episodes (14.8% sensitivity). None of the mycobacterial stains was positive. Conclusion. Routine fungal and mycobacterial stains and cultures should not be performed as they have little clinical utility in the diagnosis of PJI and are associated with significant costs. Candida species and RGM are readily recovered using BCB. More research is needed to
Aims. The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model. Methods. A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m. 2. (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy. Results. Height had a relatively strong correlation with implant size (femoral component anteroposterior (AP) Pearson correlation coefficient (ρ) = 0.73, p < 0.001; tibial component mediolateral (ML) ρ = 0.77, p < 0.001). Weight had a moderately strong correlation with implant size, (femoral component AP ρ = 0.46, p < 0.001; tibial ML ρ = 0.48, p < 0.001). There was a significant linear correlation with height, weight, and sex with implant size (femoral component R. 2. = 0.607, p < 0.001; tibial R. 2. = 0.695, p < 0.001). The Bayesian model showed high accuracy in
Aims. Spinopelvic mobility plays an important role in functional acetabular component position following total hip arthroplasty (THA). The primary aim of this study was to determine if spinopelvic hypermobility persists or resolves following THA. Our second aim was to identify patient demographic or radiological factors associated with hypermobility and resolution of hypermobility after THA. Methods. This study investigated patients with preoperative posterior hypermobility, defined as a change in sacral slope (SS) from standing to sitting (ΔSS. stand-sit. ) ≥ 30°. Radiological spinopelvic parameters, including SS, pelvic incidence (PI), lumbar lordosis (LL), PI-LL mismatch, anterior pelvic plane tilt (APPt), and spinopelvic tilt (SPT), were measured on preoperative imaging, and at
six weeks and a minimum of
one year postoperatively. The severity of bilateral hip osteoarthritis (OA) was graded using Kellgren-Lawrence criteria. Results. A total of 136 patients were identified as having preoperative spinopelvic hypermobility. At one year after THA, 95% (129/136) of patients were no longer categorized as hypermobile on standing and sitting radiographs (ΔSS. stand-sit. < 30°). Mean ΔSS. stand-sit. decreased from 36.4° (SD 5.1°) at baseline to 21.4° (SD 6.6°) at one year (p < 0.001). Mean SS. seated. increased from baseline (11.4° (SD 8.8°)) to one year after THA by 11.5° (SD 7.4°) (p < 0.001), which correlates to an 8.5° (SD 5.5°) mean decrease in seated functional cup anteversion. Contralateral hip OA was the only radiological
Aims. Stemless humeral implants have been developed to overcome stem-related complications in total shoulder arthroplasty (TSA). However, stemless implant designs may hypothetically result in less stable initial fixation, potentially affecting long-term survival. The aim of this study is to investigate early fixation and migration patterns of the stemless humeral component of the Simpliciti Shoulder System and to evaluate clinical outcomes. Methods. In this prospective cohort study, radiostereometric analysis (RSA) radiographs were obtained in 24 patients at one day, six weeks, six months, one year, and two years postoperatively. Migration was calculated using model-based RSA. Clinical outcomes were evaluated using the visual analogue scale (VAS), the Oxford Shoulder Score (OSS), the Constant-Murley Score (CMS), and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Results. At two years, median translation along the x-, y-, and z-axis was -0.12 mm (interquartile range (IQR) -0.18 to 0.02), -0.17 mm (IQR -0.27 to -0.09), and 0.09 mm (IQR 0.02 to 0.31). Median rotation around the x-, y-, and z-axis was 0.12° (IQR -0.50 to 0.57), -0.98° (IQR -1.83 to 1.23), and 0.09° (IQR -0.76 to 0.30). Overall, 20 prostheses stabilized within 12 months postoperatively. Four prostheses showed continuous migration between 12 and 24 months. At two-year follow-up, with the exception of one revised prosthesis, all clinical scores improved significantly (median VAS difference at rest: -3.0 (IQR -1.5 to -6.0); OSS 22.0 (IQR 15.0 to 25.0); CMS 29.5 (IQR 15.0 to 35.75); and DASH -30.0 (IQR -20.6 to -41.67) (all p < 0.001)) with the exception of one revised prosthesis. Conclusion. In conclusion, we found that 20 out of 24 implants stabilized within 12 months postoperatively. The significance of continuous migration in four implants is unclear and future research on the
Aims. Patients who sustain neck of femur fractures are at high risk of malnutrition. Our intention was to assess to what extent malnutrition was associated with worse patient outcomes. Methods. A total of 1,199 patients with femoral neck fractures presented to a large UK teaching hospital over a three-year period. All patients had nutritional assessments performed using the Malnutrition Universal Screening Tool (MUST). Malnutrition risk was compared to mortality, length of hospital stay, and discharge destination using logistic regression. Adjustments were made for covariates to identify whether malnutrition risk independently affected these outcomes. Results. Inpatient mortality was 5.2% (35/678) in the group at low risk of malnutrition, 11.3% (46/408) in the medium-risk group, and 17.7% (20/113) in the high-risk group. Multivariate analysis showed each categorical increase in malnutrition risk independently
Aims. Circular RNA (circRNA) S-phase cyclin A-associated protein in the endoplasmic reticulum (ER) (circSCAPER, ID: hsa_circ_0104595) has been found to be highly expressed in osteoarthritis (OA) patients and has been associated with the severity of OA. Hence, the role and mechanisms underlying circSCAPER in OA were investigated in this study. Methods. In vitro cultured human normal chondrocyte C28/I2 was exposed to interleukin (IL)-1β to mimic the microenvironment of OA. The expression of circSCAPER, microRNA (miR)-140-3p, and enhancer of zeste homolog 2 (EZH2) was detected using quantitative real-time polymerase chain reaction and Western blot assays. The extracellular matrix (ECM) degradation, proliferation, and apoptosis of chondrocytes were determined using Western blot, cell counting kit-8, and flow cytometry assays. Targeted relationships were
Aims. To analyze the potential role of synovial fluid peptidase activity as a measure of disease burden and
Aims. The last decade has seen a marked increase in surgical rib fracture fixation (SRF). The evidence to support this comes largely from retrospective cohorts, and adjusting for the effect of other injuries sustained at the same time is challenging. This study aims to assess the impact of SRF after blunt chest trauma using national prospective registry data, while controlling for other comorbidities and injuries. Methods. A ten-year extract from the Trauma Audit and Research Network formed the study sample. Patients who underwent SRF were compared with those who received supportive care alone. The analysis was performed first for the entire eligible cohort, and then for patients with a serious (thoracic Abbreviated Injury Scale (AIS) ≥ 3) or minor (thoracic AIS < 3) chest injury without significant polytrauma. Multivariable logistic regression was performed to identify
Aims. It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was
Aims. Functional rehabilitation has become an increasingly popular treatment for Achilles tendon rupture (ATR), providing comparably low re-rupture rates to surgery, while avoiding risks of surgical complications. Limited evidence exists on whether gap size should affect patient selection for this treatment option. The aim of this study was to assess if size of gap between ruptured tendon ends affects patient-reported outcome following ATR treated with functional rehabilitation. Methods. Analysis of prospectively collected data on all 131 patients diagnosed with ATR at Royal Berkshire Hospital, UK, from August 2016 to January 2019 and managed non-operatively was performed. Diagnosis was confirmed on all patients by dynamic ultrasound scanning and gap size measured with ankle in full plantarflexion. Functional rehabilitation using an established protocol was the preferred treatment. All non-operatively treated patients with completed Achilles Tendon Rupture Scores (ATRS) at a minimum of 12 months following injury were included. Results. In all, 82 patients with completed ATRS were included in the analysis. Their mean age was 51 years (standard deviation (SD) 14). The mean ATRS was 76 (SD 19) at a mean follow-up of 20 months (SD 11) following injury. Gap inversely affected ATRS with a Pearson’s correlation of -0.30 (p = 0.008). Mean ATRS was lower with gaps > 5 mm compared with ≤ 5 mm (73 (SD 21) vs 82 (SD 16); p = 0.031). Mean ATRS was lowest (70 (SD 23)) with gaps > 10 mm, with significant differences in perceived strength and pain. The overall re-rupture rate was two out of 131 (1.5%). Conclusion. Increasing gap size
Aims. Monocyte-lymphocyte ratio (MLR) or neutrophil-lymphocyte ratio (NLR) are useful for diagnosing periprosthetic joint infection (PJI), but their diagnostic values are unclear for screening fixation-related infection (FRI) in patients for whom conversion total hip arthroplasty (THA) is planned after failed internal fixation for femoral neck fracture. Methods. We retrospectively included 340 patients who underwent conversion THA after internal fixation for femoral neck fracture from January 2008 to September 2020. Those patients constituted two groups: noninfected patients and patients diagnosed with FRI according to the 2013 International Consensus Meeting Criteria. Receiver operating characteristic (ROC) curves were used to determine maximum sensitivity and specificity of these two preoperative ratios. The diagnostic performance of the two ratios combined with preoperative CRP or ESR was also evaluated. Results. The numbers of patients with and without FRI were 19 (5.6%) and 321 (94.4%), respectively. Areas under the ROC curve for diagnosing FRI were 0.763 for MLR, 0.686 for NLR, 0.905 for CRP, and 0.769 for ESR. Based on the Youden index, the optimal
Aims. We aim to objectively assess the impact of COVID-19 on mean total operative cases for all indicative procedures (as outlined by the Joint Committee on Surgical Training (JCST)) experienced by orthopaedic trainees in the deanery of the Republic of Ireland. Subjective experiences were reported for each trainee using questionnaires. Methods. During the first four weeks of the nationwide lockdown due to COVID-19, the objective impact of the pandemic on each trainee’s surgical caseload exposure was assessed using data from individual trainee logbook profiles in the deanery of the Republic of Ireland. Independent
Aims. Calprotectin (CLP) is produced in neutrophils and monocytes and released into body fluids as a result of inflammation or infection. The aim of this study was to evaluate the utility of blood and synovial CLP in the diagnosis of chronic periprosthetic joint infection (PJI). Methods. Blood and synovial fluid samples were collected prospectively from 195 patients undergoing primary or revision hip and knee arthroplasty. Patients were divided into five groups: 1) primary total hip and knee arthroplasty performed due to idiopathic osteoarthritis (OA; n = 60); 2) revision hip and knee arthroplasty performed due to aseptic failure of the implant (AR-TJR; n = 40); 3) patients with a confirmed diagnosis of chronic PJI awaiting surgery (n = 45); 4) patients who have finished the first stage of the PJI treatment with the use of cemented spacer and were qualified for replantation procedure (SR-TJR; n = 25), and 5) patients with rheumatoid arthritis undergoing primary total hip and knee arthroplasty (RA; n = 25). CLP concentrations were measured quantitatively in the blood and synovial fluid using an immunoturbidimetric assay. Additionally, blood and synovial CRP, blood interleukin-6 (IL-6), and ESR were measured, and a leucocyte esterase (LE) strip test was performed. Results. Patients with PJI had higher CLP concentrations than those undergoing aseptic revision in blood (median PJI 2.14 mg/l (interquartile range (IQR) 1.37 to 3.56) vs AR-TJR 0.66 mg/l (IQR 0.3 to 0.83); p < 0.001) and synovial fluid samples (median PJI 20.46 mg/l (IQR 14.3 to 22.36) vs AR-TJR 0.7 mg/l (IQR 0.41 to 0.95); p < 0.001). With a cut-off value of 1.0 mg/l, blood CLP showed a sensitivity, specificity, positive
Aims. The aim of this study was to determine the long-term mortality rate, and to identify factors associated with this, following primary and revision knee arthroplasty (KA). Methods. Data from the Scottish Arthroplasty Project (1998 to 2019) were retrospectively analyzed. Patient mortality data were linked from the National Records of Scotland. Analyses were performed separately for the primary and revised KA cohorts. The standardized mortality ratio (SMR) with 95% confidence intervals (CIs) was calculated for the population at risk. Multivariable Cox proportional hazards were used to identify
Objectives. Unicompartmental knee arthroplasty (UKA) is an alternative to total knee arthroplasty with isolated medial or lateral compartment osteoarthritis. However, polyethylene wear can significantly reduce the lifespan of UKA. Different bearing designs and materials for UKA have been developed to change the rate of polyethylene wear. Therefore, the objective of this study is to investigate the effect of insert conformity and material on the
Aims. The primary aim was to assess the independent influence of coronavirus disease (COVID-19) on 30-day mortality for patients with a hip fracture. The secondary aims were to determine whether: 1) there were clinical
Aims. Currently, periprosthetic fractures are excluded from the American Society for Bone and Mineral Research (ASBMR) definition of atypical femoral fracture (AFFs). This study aims to report on a series of periprosthetic femoral fractures (PFFs) that otherwise meet the criteria for AFFs. Secondary aims were to identify