Advertisement for orthosearch.org.uk
Results 301 - 320 of 507
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 605 - 613
1 Jul 1992
Amis A Camburn M Kempson S Radford W Stead A

We excised the anterior cruciate ligament from the left stifle of 24 sheep and replaced it by a polyester fibre implant routed 'over the top' of the femoral condyle and fixed, using grommets and screws. All the joints were sound, and the animals moved normally until they were killed at six, 12 and 24 months after operation. We found that the implants were always covered by host tissue, which matured into bundles with a histological appearance similar to the natural ligament. The implants were joined to the bones by organised fibrous tissue and there was no anchorage loosening. There was no synovitis, but the operated joints showed progressive cartilage degeneration. The reconstructed joints became less stable immediately after operation, but regained normal stability as the neoligaments developed. The neoligaments lost strength with time, despite tissue ingrowth. The good functional, biomechanical, and histological results justify clinical trials of this type of implant


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 5 | Pages 572 - 578
1 Dec 1982
Evans C Mears D Stanitski C

Ferrography is a technique for analysing wear by means of the magnetic separation of wear particles. To evaluate its application in human joints, the results of the ferrographic analysis of saline washings of symptomatic human knees were compared with the results of the arthroscopic examination of the same knees. Ferrography was found to be an extremely sensitive monitor of articular erosion, with a resolution far greater than that of arthroscopy. This was particularly apparent with knees suffering from a torn anterior cruciate ligament: arthroscopy detected no damage to the cartilaginous surfaces whereas ferrography detected a substantial level of "microdamage". The spectrum of wear particles showed qualitative and quantitative alterations depending upon the condition of the knee. Ferrography thus holds much promise as a potential differential diagnostic technique of great sensitivity, with particular relevance to the very early changes which precede clinical symptoms. Study of wear particles is also justified by evidence indicating an active role in the pathophysiological progression of arthritis


Bone & Joint 360
Vol. 9, Issue 2 | Pages 18 - 19
1 Apr 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 818 - 821
1 Sep 1993
Mody B Howard L Harding M Parmar H Learmonth D

We treated 39 knees with chronic deficiency of the anterior cruciate ligament by reconstruction using the ABC carbon and polyester prosthetic ligament; 31 (79.5%) were reviewed at an average follow-up of 34 months. There had been four complete failures requiring revision. The remaining 27 were studied in detail. On the Lysholm rating, only 11 knees (41%) had good results with a score of over 76. The mean anterior drawer movement was reduced from 7.6 mm before operation to 5.8 mm at review. The mean difference from the opposite uninjured knee was 3.9 mm before operation, 1 mm (in 21 patients) at mean follow-up of 7.4 months and 2.5 mm (in 27 patients) at 34 months, indicating progressive loss of effect. In our opinion the results are unsatisfactory: we do not recommend the use of this prosthetic ligament


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 915 - 920
1 Sep 1999
Sckell A Leunig M Fraitzl CR Ganz R Ballmer FT

Free patellar tendon grafts used for the intra-articular replacement of ruptured anterior cruciate ligaments (ACL) lack perfusion at the time of implantation. The central core of the graft undergoes a process of ischaemic necrosis which may result in failure. Early reperfusion of the graft may diminish the extent of this process. We assessed the role of peritendinous connective tissue in the revascularisation of the patellar tendon graft from the day of implantation up to 24 days in a murine model using intravital microscopy. The peritendinous connective-tissue envelope of the graft was either completely removed, partially removed or not stripped before implantation into dorsal skinfold chambers of recipient mice. Initial revascularisation of the grafts with preserved peritendinous connective tissues began after two days. The process was delayed by five to six times in completely stripped patellar tendons (p < 0.05). Only grafts with preserved connective tissues showed high viability whereas those which were completely stripped appeared to be subvital. The presence of peritendinous connective tissues accelerates the revascularisation of free patellar tendon grafts


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 94 - 101
1 Feb 1976
McDevitt C Muir H

Biochemical changes in the articular cartilage of the knees of mature dogs, one with natural and four with surgically induced osteoarthritis, have been investigated. The four dogs were killed three, six, nine and forty-eight weeks after division of the right anterior cruciate ligament, the left knees serving as controls. The cartilage of the joints operated on was thicker and more hydrated than the control cartilage; the proteoglycans were more easily extracted and had higher galactosamine/glucosamine molar ratios. The proportion of proteoglycans firmly associated with collagen, and hence not extractable, diminished before fibrillation was demonstrable by indian ink staining of the surface. These biochemical changes were present throughout the entire cartilage of the joints operated on of the dogs killed more than three weeks later, and of the dog with natural osteoarthritis. The results suggest that in response to altered mechanical stresses the chondrocytes synthesise proteoglycans that contain more chondroitin sulphate relative to keratin sulphate than normally, as in immature articular cartilage


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 632 - 637
1 May 2020
Gonzalez LJ Hildebrandt K Carlock K Konda SR Egol KA

Aims

Tibial plateau fractures are serious injuries about the knee that have the potential to affect patients’ long-term function. To our knowledge, this is the first study to use patient-reported outcomes (PROs) with a musculoskeletal focus to assess the long-term outcome, as compared to a short-term outcome baseline, of tibial plateau fractures treated using modern techniques.

Methods

In total, 102 patients who sustained a displaced tibial plateau fracture and underwent operative repair by one of three orthopaedic traumatologists at a large, academic medical centre and had a minimum of five-year follow-up were identified. Breakdown of patients by Schatzker classification is as follows: two (1.9%) Schatzker I, 54 (50.9%) Schatzker II, two (1.9%) Schatzker III, 13 (12.3%) Schatzker IV, nine (8.5%) Schatzker V, and 26 (24.5%) Schatzker VI. Follow-up data obtained included: Visual Analogue Scale (VAS) or Numeric Rating Scale (NRS) pain scores, Short Musculoskeletal Functional Assessment (SMFA), and knee range of movement (ROM). Data at latest follow-up were then compared to 12-month data using a paired t-test.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 49 - 58
1 Jun 2020
Mullaji A

Aims

The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA).

Methods

A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other.


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 1 | Pages 24 - 35
1 Feb 1977
McDevitt C Gilbertson E Muir H

An experimental model of osteoarthritis resulting from laxity of the joint was induced in eighteen mature dogs (at least two years old) by sectioning the anterior cruciate ligament of the right knee (stifle) with a stab incision, the left knee providing a control. A sham operation was also performed in three other dogs, in which a stab incision was made but the ligament left intact. The dogs were killed at various intervals from one to forty-eight weeks later. Morphological changes in bone, cartilage, synovial membrane and joint capsule were examined in all the joints and biochemical changes in the cartilage of three dogs killed after two, eight, and sixteen weeks. All the changes resulting from the operation progressed with time and became indistinguishable from those found in three dogs with natural osteoarthritis of the knee. There were no changes in the joints which had sham operations. As the time of onset is known, this experimental model in a larger species enables a study to be made of the biochemical as well as the morphological changes in the early stages of osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 983 - 989
1 Nov 1998
Murray DW Goodfellow JW O’Connor JJ

Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by unicompartmental arthroplasty using fully congruous mobile polyethylene bearings. At review, 34 knees were in patients who had died and 109 were in those who were still living. The mean elapsed time since operation was 7.6 years (maximum 13.8). We established the status of all but one knee. There had been five revision operations giving a cumulative prosthetic survival rate at ten years (33 knees at risk) of 98% (95% CI 93% to 100%). Considering the knee lost to follow-up as a failure, the ‘worst-case’ survival rate was 97%. No failures were due to polyethylene wear or aseptic loosening of the tibial component. One bearing which dislocated at four years was reduced by closed manipulation. The ten-year survival rate is the best of those reported for unicompartmental arthroplasty and not significantly different from the best rates for total knee replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 428 - 436
1 Apr 2001
Lovász G Park SH Ebramzadeh E Benya PD Llinás A Bellyei Á Luck JV Sarmiento A

To investigate the effect of instability on the remodelling of a minor articular surface offset, we created a 0.5 mm coronal step-off of the medial femoral condyle in 12 New Zealand white rabbits and transected the anterior cruciate ligament (ACL). A control group of 12 rabbits had only ACL resection and the opposite knee was used as the non-operated control. The osteoarthritic changes at 6, 12 and 24 weeks after surgery were evaluated histologically. In addition, changes in the immunological detection of 3-B-3(-) and 7-D-4 chondroitin-6-sulphate epitopes were determined because of the previous association of such changes with repair of cartilage and early osteoarthritis. In the instability/step-off group there was rapidly progressing focal degeneration of cartilage on the high side of the defect, not seen in previous step-off studies in stable knees. The rest of the femoral condyles and the tibial plateaux of the instability/step-off group had moderate osteoarthritis similar to that of the instability group. 3-B-3(-) was detectable in the early and the intermediate stages of osteoarthritis but no staining was seen in the severely damaged cartilage zones. Immunoreactivity with 7-D-4 increased as degeneration progressed. Our findings have shown that even a minor surface offset may induce rapid degeneration of cartilage when the stability of the knee is compromised


Bone & Joint 360
Vol. 8, Issue 3 | Pages 18 - 19
1 Jun 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 41 - 48
1 Jan 1993
O'Connor J

A computer-based model of the knee was used to study forces in the cruciate ligaments induced by co-contraction of the extensor and flexor muscles, in the absence of external loads. Ligament forces are required whenever the components of the muscle forces parallel to the tibial plateau do not balance. When the extending effect of quadriceps exactly balances the flexing effect of hamstrings, the horizontal components of the two muscle forces also balance only at the critical flexion angle of 22 degrees. The calculations show that co-contraction of the quadriceps and hamstring muscles loads the anterior cruciate ligament from full extension to 22 degrees of flexion and loads the posterior cruciate at higher flexion angles. In these two regions of flexion, the forward pull of the patellar tendon on the tibia is, respectively, greater than or less than the backward pull of hamstrings. Simultaneous quadriceps and gastrocnemius contraction loads the anterior cruciate over the entire flexion range. Simultaneous contraction of all three muscle groups can unload the cruciate ligaments entirely at flexion angles above 22 degrees. These results may help the design of rational regimes of rehabilitation after ligament injury or repair


Bone & Joint 360
Vol. 9, Issue 2 | Pages 39 - 43
1 Apr 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 288 - 294
1 Mar 1998
Webb JM Corry IS Clingeleffer AJ Pinczewski LA

We treated 90 patients with an isolated injury to the anterior cruciate ligament (ACL) by reconstruction using a patellar tendon autograft and interference screw fixation. Of these, 82 (91%) were available for review at 24 months. Two grafts and two contralateral ACLs had ruptured during sport and there was one case of atraumatic graft resorption. Using the assessment of the International Knee Documentation Committee (IKDC), 86% of the remaining patients were normal or nearly normal. The median Lysholm knee score was 95/100 and 84% of patients were participating in moderate to strenuous activity. All had grade-0 or grade-1 Lachman, pivot-shift and anterior-drawer tests. Measurement with the KT1000 arthrometer gave a side-to-side difference of < 3 mm of anterior tibial displacement in 90%. Sixty-six radiographs were IKDC grade A and one was grade B. Pain on kneeling was present in 31% and graft site pain in 44%. At 24 months after operation all patients had excellent knee stability, a high rate of return to sport and minimal radiological evidence of degenerative change. Our series therefore represents a basis for comparison of results using other techniques and after more severe injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 1072 - 1076
1 Sep 2004
Tien Y Chih T Lin JC Ju C Lin S

The healing of a hamstring graft to bone is the weak link in the reconstruction of a cruciate ligament using this donor material. We therefore investigated the augmentation of healing at the tendon-bone interface using calcium-phosphate cement (CPC). We performed semitendinosus autograft reconstructions of the anterior cruciate ligament on both knees of 22 New Zealand white rabbits. The interface between the grafted tendon and the bone tunnel for one knee was filled with CPC. Six rabbits were killed at the end of the first and second post-operative weeks in order to evaluate the biomechanical changes. Two rabbits were then killed sequentially at the end of weeks 1, 3, 6, 12 and 24 after operation and tissue removed for serial histological observation. Histological examination showed that the use of CPC produced early, diffuse and massive bone ingrowth. By contrast, in the non-CPC group of rabbits only a thin layer of new bone was seen. Mechanical pull-out testing at one week showed that the mean maximal tensile strength was 6.505 ± 1.333 N for the CPC group and 2.048 ± 0.950 N for the non-CPC group. At two weeks the values were 11.491 ± 2.865 N and 5.452 ± 3.955 N, respectively. Our findings indicate that CPC is a potentially promising material in clinical practice as regards its ability to reinforce the fixation of the tendon attachment to bone and to augment the overall effectiveness of tendon healing to bone


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 232 - 235
1 Mar 1995
Liu S Kabo J Osti L

We measured the initial fixation strength of a new graft, bone-hamstring-bone (BHB), for reconstruction of the anterior cruciate ligament (ACL) in 79 porcine knees and compared it with that of the normal porcine ACL and of the bone-patellar tendon-bone (BPB) graft. All specimens were subjected to ultimate load to failure and cyclic loading tests to assess the amount of graft slippage. The ultimate load to failure for the intact ACL was 1266 +/- 250 N, for the BPB graft 663 +/- 192 N and for the BHB graft 354 +/- 92 N (p < 0.01). After cycling to 235 N (the maximum load for all groups without failure) the average residual displacements after removal of the load for the ACL, BPB and BHB grafts were 0.031 +/- 0.013 cm, 0.078 +/- 0.033 cm, and 0.322 +/- 0.222 cm, respectively (p < 0.01). For the BHB graft the load to failure was less and the amount of graft slippage was more than for the BPB graft. Neither form of reconstruction was as strong as the intact ACL


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 276 - 279
1 Mar 2020
Oussedik S Abdel MP Victor J Pagnano MW Haddad FS

Dissatisfaction following total knee arthroplasty is a well-documented phenomenon. Although many factors have been implicated, including modifiable and nonmodifiable patient factors, emphasis over the past decade has been on implant alignment and stability as both a cause of, and a solution to, this problem. Several alignment targets have evolved with a proliferation of techniques following the introduction of computer and robotic-assisted surgery. Mechanical alignment targets may achieve mechanically-sound alignment while ignoring the soft tissue envelope; kinematic alignment respects the soft tissue envelope while ignoring the mechanical environment. Functional alignment is proposed as a hybrid technique to allow mechanically-sound, soft tissue-friendly alignment targets to be identified and achieved.

Cite this article: Bone Joint J 2020;102-B(3):276–279.


Bone & Joint 360
Vol. 8, Issue 2 | Pages 2 - 8
1 Apr 2019
Shivji F Bryson D Nicolaou N Ali F


Bone & Joint 360
Vol. 9, Issue 1 | Pages 24 - 25
1 Feb 2020