Advertisement for orthosearch.org.uk
Results 301 - 320 of 3752
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 1 | Pages 90 - 95
1 Feb 1971
McSweeny A

1. After exclusion of the well known causes of torsion such as congenital dislocation of the hip, Legg-Perthes' disease, cerebral palsy and congenital talipes equinovarus, examination of 1,320 nearly normal children disclosed an incidence of 13·6 per cent toeing-in or toeing-out. 2. There was a female preponderance of seven to three on presentation decreasing to four to three in uncorrected cases. 3. There was persisting upper femoral torsion of greater than 10 degrees in two-thirds of all cases of toeing-in whether corrected or uncorrected. 4. When correction of toeing-in occurred it took place between four and seven years of age, but mainly at five years. 5. There was a normal angle of anteversion in one-third of children whose toeing-in was not corrected. This suggests the possibility of acetabular maldirection. 6. Uncorrected torsional stresses may play a part in the later development of osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 679 - 683
1 Jul 2000
Gautier E Ganz K Krügel N Gill T Ganz R

The primary source for the blood supply of the head of the femur is the deep branch of the medial femoral circumflex artery (MFCA). In posterior approaches to the hip and pelvis the short external rotators are often divided. This can damage the deep branch and interfere with perfusion of the head. We describe the anatomy of the MFCA and its branches based on dissections of 24 cadaver hips after injection of neoprene-latex into the femoral or internal iliac arteries. The course of the deep branch of the MFCA was constant in its extracapsular segment. In all cases there was a trochanteric branch at the proximal border of quadratus femoris spreading on to the lateral aspect of the greater trochanter. This branch marks the level of the tendon of obturator externus, which is crossed posteriorly by the deep branch of the MFCA. As the deep branch travels superiorly, it crosses anterior to the conjoint tendon of gemellus inferior, obturator internus and gemellus superior. It then perforates the joint capsule at the level of gemellus superior. In its intracapsular segment it runs along the posterosuperior aspect of the neck of the femur dividing into two to four subsynovial retinacular vessels. We demonstrated that obturator externus protected the deep branch of the MFCA from being disrupted or stretched during dislocation of the hip in any direction after serial release of all other soft-tissue attachments of the proximal femur, including a complete circumferential capsulotomy. Precise knowledge of the extracapsular anatomy of the MFCA and its surrounding structures will help to avoid iatrogenic avascular necrosis of the head of the femur in reconstructive surgery of the hip and fixation of acetabular fractures through the posterior approach


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1002 - 1009
1 Aug 2018
Westerman RW Whitehouse SL Hubble MJW Timperley AJ Howell JR Wilson MJ

Aims

The aim of this study was to report the initial results of the Exeter V40 stem, which became available in 2000.

Patients and Methods

A total of 540 total hip arthroplasties (THAs) were performed in our unit using this stem between December 2000 and May 2002. Our routine protocol is to review patients postoperatively and at one, five, and ten years following surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 973 - 978
1 Nov 1996
Malkani AL Voor MJ Fee KA Bates CS

We have tested the axial and torsional stability of femoral components after revision arthroplasty in a cadaver model, using impacted morsellised cancellous graft and cement. Each one of six matched pairs of fresh frozen human femora had either a primary or a revision prosthesis cemented in place. For the ‘revision’ experiments, all cancellous bone was removed from the proximal femur which was then over-reamed to create a smooth-walled cortical shell. An MTS servohydraulic test frame was used to apply axial and torsional loads to each specimen through the prosthetic femoral heads with the femur submerged in isotonic saline solution at 37°C. The mean subsidence was 0.27 ± 0.17 mm for the primary and 0.52 ± 0.30 mm for the revision groups. The difference was statistically significant (p < 0.025), but the mean subsidence was < 1 mm in both groups. The mean maximum torque before failure was 42.9 ± 26.9 N-m for the primary and 34.8± 20.7 N-m for the revision groups. This difference was not statistically significant (p > 0.015). Based on our results we suggest that revision of the femoral component using morsellised cancellous graft followed by cementing with a collarless prosthesis with a polished tapered stem restores the integrity of the proximal femur and provides immediate stability of the implant


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 432 - 438
1 May 1994
Freeman M Plante-Bordeneuve P

The vertical migration of four configurations of a proximal femoral prosthesis, followed for up to nine years, was measured on standard radiographs. The same implant was used without cement (group 1) and with cement (group 2). The migration of both groups was linear from six months onwards. The mean migration rate and the incidence of late aseptic loosening were both greater in group 1. Survival analysis of the two groups, however, showed no statistically significant difference. In both groups, hips later destined for revision migrated more rapidly from the initial postoperative period onwards, than did the remainder. A threshold migration of 1.2 mm/year during the first two years after implantation detected hips likely to fail with a specificity of 86% and a sensitivity of 78%. This 'migration test' was applied to the results in two further groups of patients in which a modified femoral prosthesis had been implanted without hydroxyapatite coating (group 3) and with hydroxyapatite coating (group 4). The test distinguished between the four groups and suggested that at least two fixation procedures should be abandoned. We conclude that vertical migration measured on standard radiographs in the first two years after implantation can be used to predict late aseptic loosening. New prosthetic configurations should be evaluated by migration measurements before their general release. Our observations support the view that one cause of late aseptic loosening is imperfect initial fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 649 - 654
1 May 2006
Gupta A Meswania J Pollock R Cannon SR Briggs TWR Taylor S Blunn G

We report our early experience with the use of a non-invasive distal femoral expandable endoprosthesis in seven skeletally immature patients with osteosarcoma of the distal femur. The patients had a mean age of 12.1 years (9 to 15) at the time of surgery. The prosthesis was lengthened at appropriate intervals in outpatient clinics, without anaesthesia, using the principle of electromagnetic induction. The patients were functionally evaluated using the Musculoskeletal Tumour Society scoring system. The mean follow-up was 20.2 months (14 to 30). The prostheses were lengthened by a mean of 25 mm (4.25 to 55) and maintained a mean knee flexion of 110° (100° to 120°). The mean Musculoskeletal Tumour Society score was 68% (11 to 29). Complications developed in two patients; one developed a flexion deformity of 25° at the knee joint, which was subsequently overcome and one died of disseminated disease. The early results from patients treated with this device have been encouraging. The implant avoids multiple surgical procedures, general anaesthesia and assists in maintaining leg-length equality


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 676 - 682
1 May 2009
Østbyhaug PO Klaksvik J Romundstad P Aamodt A

Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12 pairs of human cadaver femora. A hip simulator reproduced the physiological loads on the proximal femur in single-leg stance and stair-climbing. The cortical strains were measured before and after the insertion of the stems. Significantly higher strain shielding was seen in Gruen zones 7, 6, 5, 3 and 2 after the insertion of the anatomical stem compared with the customised stem. For the anatomical stem, the hoop strains on the femur also indicated that the load was transferred to the cortical bone at the lower metaphyseal or upper diaphyseal part of the proximal femur. The customised stem induced a strain pattern more similar to that of the intact femur than the standard, anatomical stem


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 962 - 970
1 Jul 2007
Albert C Patil S Frei H Masri B Duncan C Oxland T Fernlund G

This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting. Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured. Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration/micromotion, and valgus/varus migration were significantly higher in the no-pressure group than in that subjected to pressure. These motion components correlated negatively with the mean area of cement and its contact with the endosteum. The presence of cement at the endosteum appears to play an important role in the initial stability of the implant following impaction allografting


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 974 - 978
1 Sep 2004
Thomas SR Shukla D Latham PD

Cemented titanium stems in hip arthroplasty are associated with proximal cement-stem debonding and early failure. This was well publicised with the 3M Capital hip. However, corrosion in this setting has been reported with only one stem design and is less widely accepted. We present a series of 12 cemented titanium Furlong Straight Stems which required revision at a mean of 78 months for thigh pain. At revision the stems were severely corroded in a pattern which was typical of crevice corrosion. Symptoms were eliminated after revision to an all-stainless steel femoral prosthesis of the same design. We discuss the likely causes for the corrosion. The combination of a titanium stem and cement appears to facilitate crevice corrosion


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 452 - 455
1 May 1989
Nunn D Freeman M Tanner K Bonfield W

Torsional instability of femoral components has not received much attention, and is difficult to detect in conventional radiographs. To test this we designed a system to apply a load in an anteroposterior direction to the head of a femoral component, implanted into a cadaveric femur. Rotation within the bone was measured, using a purpose built transducer, with and without preservation of the neck, with and without cement, and with longitudinal ridges but no cement. The results show that torsional instability may be a problem in uncemented replacement. Preservation of the femoral neck and the use of a ridged prosthesis increases resistance to rotation. Rotational movements occurring in vivo during such activities as climbing stairs and rising from the seated position may contribute to mechanical loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 261 - 264
1 Mar 2003
Hosalkar HS Jones S Chowdhury M Hartley J Hill RA

We review the results of a modified quadricepsplasty in five children who developed stiffness of the knee after femoral lengthening for congenital short femur using an Ilizarov external fixator which spanned the knee. All had a full range of movement of the knee before lengthening was undertaken. Unifocal lengthening was carried out in the distal metaphysiodiaphyseal region of the distal femur with a mean gain of 6.5 cm. The mean percentage lengthening was 24%. At the end of one year after removal of the Ilizarov frame and despite intensive physiotherapy all patients had stiffness. Physiotherapy was continued after the quadricepsplasty and, at the latest follow-up (mean 27 months), the mean active flexion was 102° (80 to 130). The gain in movement ranged from 50° to 100°. One patient had a superficial wound infection which settled after a course of oral antibiotics. None developed an increased extension lag after surgery and all were very satisfied with the results. Quadricepsplasty is a useful procedure for stiffness of the knee after femoral lengthening which has not responded to physiotherapy


The Journal of Bone & Joint Surgery British Volume
Vol. 42-B, Issue 2 | Pages 273 - 279
1 May 1960
Rennie AM

1. Epiphysial tilt commonly precedes slipping. 2. This tilt is due to a diminished or arrested growth from compression of the back of the epiphysial plate. 3. The stresses on the upper end of the femur are such that the upper femoral epiphysial plate is peculiarly liable to compression. 4. A primary abnormality of the cartilage of the epiphysial plate renders it susceptible to the effect of compression. 5. Because this abnormality is diffuse, deformities due to a similar pathology may be found elsewhere, notably in the spine


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 305 - 312
1 Jun 1982
Steinbrink K Engelbrecht E Fenelon G

The use of a total femoral prosthesis can offer a realistic alternative to amputation or disarticulation. The limited indications for such a prosthesis in the surgical management of primary bone tumours and pathological fractures still exist. In this specialised clinic there is an increased need to replace the entire femur where repeated procedures have failed, from loss of bone stock with infection or because of non-union in the presence of a prosthesis. Over the past eight years, four basic models have been developed. The most recent designs allow for the preservation of non-involved bone or for stable support where there is complete acetabular destruction


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 557 - 563
1 Aug 1985
Campanacci M Cervellati C Donati U

The size and shape of the patella make it suitable for the partial replacement of a femoral or tibial condyle resected for tumour, or destroyed by trauma. It can provide a good articular surface and may give satisfactory knee function. Nineteen cases of patellar grafts are presented, with follow-up from two to nine years. Good consolidation of the graft and fair stability of the joint were obtained; the range of movement was 90 degrees or more in 79% of cases. In contrast with an allograft of a femoral or tibial condyle, the technique described does not need an allograft bank, has a lower risk of infection, and allows better and quicker consolidation and revascularisation of the grafts, as well as a better range of movement at the knee, probably because of the lack of fibrosis from immunological reaction. Merle d'Aubigne's technique, using a patellar graft with a vascular muscle pedicle, is useful only for some cases, requires a longer period of immobilisation and weakens the extensor apparatus. Our series shows that consolidation and revascularisation of a patellar graft can occur in the absence of a pedicle


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 385 - 389
1 May 1992
Barrack R Mulroy R Harris W

To assess the effect of improved methods of femoral cementing on the loosening rates in young patients, we reviewed 50 'second-generation' cemented hip arthroplasties in 44 patients aged 50 years or less. The femoral stems were all collared and rectangular in cross-section with rounded corners. The cement was delivered by a gun into a medullary canal occluded distally with a cement plug. A clinical and radiographic review was undertaken at an average of 12 years (10 to 14.8) and no patient was lost to follow-up. No femoral component was revised for aseptic loosening, and only one stem was definitely loose by radiographic criteria. By contrast, 11 patients had undergone revision for symptomatic aseptic loosening of the acetabular component and 11 more had radiographic signs of acetabular loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 406 - 408
1 May 1992
Nordsletten L Holm I Steen H Folleras G Bjerkreim I

We performed bilateral femoral shortening operations on 15 skeletally mature patients (11 women and four men). Their mean height pre-operatively was 193.5 cm and they were shortened by 5 to 9 cm. We used a subtrochanteric Z-osteotomy with an AO condylar plate in 11 patients, and mid-diaphyseal osteotomy with an intramedullary locking nail in four. After an average follow-up of 8.1 years, isokinetic muscle testing showed that muscle strength was reduced bilaterally in five patients. The strength ratio between hamstrings and quadriceps muscles was normal in all those treated by subtrochanteric shortening; in those shortened at the mid-shaft the quadriceps was relatively weaker. The result was rated as excellent by 11 patients, very good by three, and good by one


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 975 - 978
1 Nov 1997
Bar-On E Sagiv S Porat S

We report the outcome of 19 children aged 5.2 to 13.2 years with 20 fractures of the femoral shaft requiring surgery, who were randomly assigned to have external fixation (EF) or flexible intramedullary nailing (FIN) (10 fractures each). The duration of the operation averaged 56 minutes for the EF group with 1.4 minutes of fluoroscopy, compared with 74 minutes and 2.6 minutes, respectively, for the FIN group. The early postoperative course was similar, but the EF group showed much more callus formation. The time to full weight-bearing, full range of movement and return to school were all shorter in the FIN group. The FIN complications included one transitory foot drop and two cases of bursitis at an insertion site. In the EF group there was one refracture, one rotatory malunion requiring remanipulation and two pin-track infections. At an average follow-up of 14 months two patients in the EF group had mild pain, four had quadriceps wasting, one had leg-length discrepancy of over 1 cm, four had malalignment of over 5°, and one had limited hip rotation. In the FIN group, one patient had mild pain and one had quadriceps wasting; there were no length discrepancies, malalignment or limitation of movement. Parents of the FIN group were more satisfied. We recommend the use of flexible intramedullary nailing for fractures of the femoral shaft which require surgery, and reserve external fixation for open or severely comminuted fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 863 - 866
1 Jun 2005
Nagarajah K Aslam N McLardy Smith P McNally M

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 660 - 661
1 Jul 1991
Knudsen C Grobler G Close R

We describe a simple method of inserting the distal screws in a locked femoral nail. The method requires no aiming device and no assistant. The only equipment needed is a 3 mm Kirschner wire and an air drill


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 454 - 460
1 Mar 2010
Baleani M Bialoblocka-Juszczyk E Engels GE Viceconti M

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue tests, and were examined for porosity. Pre-heating the stem alone significantly increased the mean temperature values measured within the mantle (+14.2°C) (p < 0.001) and reduced the mean curing time (−1.5 min) (p < 0.001). The addition of vacuum mixing modulated the mean rise in the temperature of polymerisation to 11°C and reduced the mean duration of the process by one minute and 50 seconds (p = 0.01 and p < 0.001, respectively). In all cases, the maximum temperature values measured in the mould simulating the femur were < 50°C. The mixing technique and pre-heating the stem slightly increased the static mechanical strength of bone cement. However, the fatigue life of the cement was improved by both vacuum mixing and pre-heating the stem, but was most marked (+ 280°C) when these methods were combined. Pre-heating the stem appears to be an effective way of improving the quality of the cement mantle, which might enhance the long-term performance of bone cement, especially when combined with vacuum mixing