Thirty-one patients with rheumatoid arthritis were reviewed after Shiers arthroplasty of the knee joint for which the main indication was intractable pain. Seven patients had the operation done to both knees. This review was done to assess the
We describe 129 patients with disabling instability of the knee due to deficiency of the anterior cruciate ligament. They were treated by replacement of the ligament with a Leeds-Keio prosthesis supplemented by an extra-articular MacIntosh lateral substitution reconstruction. After an average period of 71 months a satisfactory outcome was found in only 60% of knees. Nine had required revision because of recurrent instability and the pivot-shift sign had become positive in 40% of patients. In our opinion the
The consensus is that bipolar hemiarthroplasty (BHA) in allograft-prosthesis composite (APC) reconstruction of the proximal femur following primary tumour resection provides more stability than total hip arthroplasty (THA). However, no comparative study has been performed. In this study, we have compared the outcome and complication rates of these two methods. In a retrospective study, 57 patients who underwent APC reconstruction of proximal femur following the primary tumour resection, either using BHA (29) or THA (28), were included. Functional outcome was assessed using the Musculoskeletal Tumour Society (MSTS) scoring system and Harris Hip Score (HHS). Postoperative complications of the two techniques were also compared.Aims
Methods
We investigated the feasibility in the dog of using transfers of the distal ulna into the radius either as growth plate replacements or as accessory growth plates in the diaphysis. Preliminary work determined the most satisfactory method of skeletal fixation. The experimental study showed that transfers used as growth plate replacements grew at almost normal rates, uniting with the recipient bone in a mean of 7.1 weeks. Transfers into the diaphysis initially nearly doubled the growth rate of the radius, although in the
We describe the clinical and radiological results of 38 total hip replacements (THR) using the JRI Furlong hydroxyapatite-ceramic (HAC)-coated femoral component in patients younger than 50 years. The mean age at the time of operation was 42 years (22 to 49) and the mean length of follow-up was ten years (63 to 170 months). All patients receiving a Furlong HAC THR were entered into the study regardless of the primary pathology including patients who had undergone previous hip surgery. The mean Harris hip score improved from 44 before operation to 92 at the last postoperative review. After 12 years the cumulative surivival for the stem was 100% (95% confidence interval 89 to 100). No femoral component was revised. Our results show that the Furlong HAC implant gives excellent
Restoration of neutral alignment of the leg is an important factor affecting the
The
The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncemented metal-backed acetabular components. A total of 9113 primary uncemented acetabular components were implanted in 7937 patients between 1987 and 2007. These were included in a prospective, population-based observational study. All the implants were modular and metal-backed with ultra-high-molecular-weight polyethylene liners. The femoral heads were made of stainless steel, cobalt-chrome (CoCr) alloy or alumina ceramic. In all, seven different designs of acetabular component were evaluated by the Kaplan-Meier survivorship method and Cox regression analysis. Most acetabular components performed well up to seven years. When the endpoint was revision of the acetabular component because of aseptic loosening, the survival ranged between 87% and 100% at ten years. However, when the endpoint was revision for any reason, the survival estimates were 81% to 92% for the same implants at ten years. Aseptic loosening, wear, osteolysis and dislocation were the main reasons for the relatively poor overall performance of the acetabular components. Prostheses with alumina heads performed slightly better than those with stainless steel or CoCr alloy in subgroups. Whereas most acetabular components performed well at seven years, the survivorship declined with longer follow-up. Fixation was generally good. None of the metal-backed uncemented acetabular components with ultra-high-molecular-weight polyethylene liners in our study had satisfactory
We present the
We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were ≤ 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer). Cementless total knee replacement can achieve excellent
Eighty-four children suffering from Perthes' disease are reviewed. The policy of management for these patients was one by which 55 per cent of the cases had no active treatment and the remainder were treated by operation. Results of the series show an improvement over a previously reported series of untreated controls, particularly where clinical management had been possible throughout the disease process. The importance of early definitive treatment for Group 4 cases is stressed. It is concluded that in the early stages where "head-at-risk" signs are not present, treatment may be conservative. Should these signs develop later the
Revision hip arthroplasty in patients with massive acetabular bone deficiency has generally given poor
Of 23 children (35 feet) with cerebral palsy who had undergone a Grice extra-articular subtalar arthrodesis for a valgus hindfoot between 1976 and 1981, we reviewed 17 (26 feet), at a mean of 20 years (17 years 3 months to 22 years 4 months) after operation. Seven were quadriplegic, eight spastic diplegic, and two hemiplegic. They were all able to walk at the time of operation. Thirteen patients (20 feet) were pleased with the Grice procedure, 13 had no pain and 15 (23 feet) were still able to walk. The clinical results were satisfactory for most feet. Radiography showed that the results had been maintained over time but 14 feet developed a mean ankle valgus of 11° (6 to 18) with a compensatory hindfoot varus in 12 feet. No deformity of the talus or arthritis of adjacent joints was noted. The Grice procedure gives good
We treated 249 patients for ingrowing toenails in a prospective randomised study which compared wedge excision with segmental phenol cauterisation. Follow-up of 97% was at a minimum of 14 months. The analgesic requirement was significantly lower after phenol cauterisation (p less than 0.001), and significantly fewer patients needed to miss school or work (p = 0.001). Recurrence of ingrowth was seen in 16% after wedge excision and 9.6% after phenol cauterisation (not significant), but re-operation was significantly less frequent after phenol (p less than 0.01). Phenol cauterisation gives better short-term and
We have reviewed 54 hips in 46 patients from 2 to 14 years after a joint-preserving operation for idiopathic avascular necrosis of the femoral head. The choice between core decompression (17 hips), bone grafting (18), rotation osteotomy (15) or varus osteotomy (4) was determined by the stage and location of the area of necrosis. The overall success rate was unexpectedly low at 60%. Core decompression and bone grafting by our techniques gave poor
Aims. Approved by the Food and Drug Administration in 2004, the Phase
III Oxford Medial Partial Knee is used to treat anteromedial osteoarthritis
(AMOA) in patients with an intact anterior cruciate ligament. This
unicompartmental knee arthroplasty (UKA) is relatively new in the
United States, and therefore
The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or
A combined open and percutaneous operative technique has been devised for repair of tendo Achillis. This minimises postoperative scarring. We compared the
We evaluated the
We evaluated the