The optimal management of intracapsular fractures of the femoral
neck in independently mobile patients remains open to debate. Successful
fixation obviates the limitations of arthroplasty for this group
of patients. However, with fixation failure rates as high as 30%,
the outcome of revision surgery to salvage total hip arthroplasty
(THA) must be considered. We carried out a systematic review to
compare the outcomes of salvage THA and primary THA for intracapsular
fractures of the femoral neck. We performed a Preferred Reporting Items for Systematic Reviews
and Meta-Analysis (PRISMA) compliant systematic review, using the
PubMed, EMBASE and Cochrane libraries databases. A meta-analysis
was performed where possible, and a narrative synthesis when a meta-analysis
was not possible.Aims
Patients and Methods
The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics. Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired student Objectives
Methods
Glenoid bone loss can be a challenging problem when revising
a shoulder arthroplasty. Precise pre-operative planning based on
plain radiographs or CT scans is essential. We have investigated
a new radiological classification system to describe the degree
of medialisation of the bony glenoid and that will indicate the
amount of bone potentially available for supporting a glenoid component.
It depends on the relationship between the most medial part of the
articular surface of the glenoid with the base of the coracoid process
and the spinoglenoid notch: it classifies the degree of bone loss
into three types. It also attempts to predict the type of glenoid reconstruction
that may be possible (impaction bone grafting, structural grafting
or simple non-augmented arthroplasty) and gives guidance about whether
a pre-operative CT scan is indicated. Inter-method reliability between plain radiographs and CT scans
was assessed retrospectively by three independent observers using
data from 39 randomly selected patients. Inter-observer reliability and test-retest reliability was tested
on the same cohort using Cohen's kappa statistics. Correlation of
the type of glenoid with the Constant score and its pain component
was analysed using the Kruskal-Wallis method on data from 128 patients.
Anatomical studies of the scapula were reviewed to explain the findings.Aims
Patients and Methods
Single event multilevel surgery (SEMLS) has been shown to improve
gait in children with cerebral palsy (CP). However, there is limited
evidence regarding long-term outcomes and factors influencing them. In total 39 children (17 females and 22 males; mean age at SEMLS
ten years four months, standard deviation 37 months) with bilateral
CP (20 Gross Motor Function Classification System (GMFCS) level
II and 19 GMFCS level III) treated with SEMLS were included. Children
were evaluated using gait analysis and the Gait Deviation Index
(GDI) before SEMLS and one, two to three, five and at least ten
years after SEMLS. A linear mixed model was used to estimate the
effect of age at the surgery, GMFCS and follow-up period on GDI. Aims
Methods
There is evidence that high levels of physical
activity following arthroplasty of the hip or knee can lead to early revision.
However, the term ‘highly active’ is not well defined. A validated ankle accelerometer was used to quantify activity
in 13 patients, who had undergone a total of 20 arthroplasties of
the lower limbs and who had active lifestyles. The assessments were
taken at a mean of 8.7 years post-operatively (1.8 to 15.8). The mean gait cycles per day was 8273 (5964 to 12 557), which
extrapolates to 3.0 million cycles per year (cpy) (2.2 to 4.6).
The mean percentage of time spent in high activity mode was 4.3%,
or about one hour per day. The mean percentage of cycles in high
activity was 40%. Based on these data, we propose the following definitions of
high activity: >
3 million cpy; one hour per day in high activity
mode; 40% of cycles in high activity mode. Extrapolating the sample of activity over the time since operation,
the mean cycles per arthroplasty was 25.2 million, with a maximum
of 44.1 million. No joint has been revised, or shows evidence of
impending failure. Cite this article:
We aimed to assess the comparability of data in joint replacement
registries and identify ways of improving the comparisons between
registries and the overall monitoring of joint replacement surgery. We conducted a review of registries that are full members of
the International Society of Arthroplasty Registries with publicly
available annual reports in English. Of the six registries which
were included, we compared the reporting of: mean age, definitions
for revision and re-operation, reasons for revision, the approach
to analysing revisions, and patient-reported outcome measures (PROMs)
for primary and revision total hip arthroplasty (THA) and hip resurfacing
arthroplasty (HRA).Aims
Materials and Methods
The purpose of this study was to evaluate the
effect of various non-operative modalities of treatment (transcutaneous
electrical nerve stimulation (TENS); neuromuscular electrical stimulation
(NMES); insoles and bracing) on the pain of osteoarthritis (OA)
of the knee. We conducted a systematic review according to the Preferred Reporting
Items for Systematic Reviews and Meta-Analyses guidelines to identify
the therapeutic options which are commonly adopted for the management
of osteoarthritis (OA) of the knee. The outcome measurement tools used in the different studies were
the visual analogue scale and The Western Ontario and McMaster Universities
Arthritis Index pain index: all pain scores were converted to a
100-point scale. A total of 30 studies met our inclusion criteria: 13 on insoles,
seven on TENS, six on NMES, and four on bracing. The standardised
mean difference (SMD) in pain after treatment with TENS was 1.796,
which represented a significant reduction in pain. The significant
overall effect estimate for NMES on pain was similar to that of
TENS, with a SMD of 1.924. The overall effect estimate of insoles
on pain was a SMD of 0.992. The overall effect of bracing showed
a significant reduction in pain of 1.34. Overall, all four non-operative modalities of treatment were
found to have a significant effect on the reduction of pain in OA
of the knee. This study shows that non-operative physical modalities of treatment
are of benefit when treating OA of the knee. However, much of the
literature reviewed evaluates studies with follow-up of less than
six months: future work should aim to evaluate patients with longer
follow-up. Cite this article:
Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of ‘proven’ cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes. This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.Background
Design
We compared the ceiling effects of two patient-rating
scores, the Disability of the Arm, Shoulder and Hand (DASH) and
Patient-Rated Wrist Evaluation (PRWE), and a physician-rating score,
the Modified Mayo Wrist Score (MMWS) in assessing the outcome of
surgical treatment of an unstable distal radial fracture. A total
of 77 women with a mean age of 64.2 years (50 to 88) who underwent
fixation using a volar locking plate for an unstable distal radial fracture
between 2011 and 2013 were enrolled in this study. All completed
the DASH and PRWE questionnaires one year post-operatively and were
assessed using the MMWS by the senior author. The ceiling effects
in the outcome data assessed for each score were estimated. The data assessed with both patient-rating scores, the DASH and
PRWE, showed substantial ceiling effects, whereas the data assessed
with MMWS showed no ceiling effect. Researchers should be aware of a possible ceiling effect in the
assessment of the outcome of the surgical treatment of distal radial
fractures using patient-rating scores. It could also increase the
likelihood of a type II error. Cite this article:
Current studies on the additional benefit of using computed tomography
(CT) in order to evaluate the surgeons’ agreement on treatment plans
for fracture are inconsistent. This inconsistency can be explained
by a methodological phenomenon called ‘spectrum bias’, defined as
the bias inherent when investigators choose a population lacking
therapeutic uncertainty for evaluation. The aim of the study is
to determine the influence of spectrum bias on the intra-observer
agreement of treatment plans for fractures of the distal radius. Four surgeons evaluated 51 patients with displaced fractures
of the distal radius at four time points: T1 and T2: conventional
radiographs; T3 and T4: radiographs and additional CT scan (radiograph
and CT). Choice of treatment plan (operative or non-operative) and
therapeutic certainty (five-point scale: very uncertain to very
certain) were rated. To determine the influence of spectrum bias,
the intra-observer agreement was analysed, using Kappa statistics,
for each degree of therapeutic certainty. Objectives
Methods
Currently, there is little information about the need for peri-operative
blood transfusion in patients undergoing shoulder arthroplasty. The purpose of this study was to identify the rate of transfusion
and its predisposing factors, and to establish a blood conservation
strategy. We identified all patients who had undergone shoulder arthroplasty
at our hospital between 1 January 2011 and 31 December 2013. The
rate of transfusion was determined from the patient’s records. While
there were exceptions, patients typically underwent transfusion
if they had a level of haemoglobin of <
7.5 g/dl if asymptomatic,
<
9.0 g/dl if they had a significant cardiac history or symptoms
of dizziness or light headedness. Multivariable regression analysis was undertaken to identify
predictors of transfusion. High- and low-risk cohorts for transfusion
were identified from a receiver operating characteristic (ROC) curve.Aims
Methods
Between 2005 and 2012, 50 patients (23 female, 27 male) with
nonunion of the humeral shaft were included in this retrospective
study. The mean age was 51.3 years (14 to 88). The patients had
a mean of 1.5 prior operations ( All patients were assessed according to a specific risk score
in order to devise an optimal and individual therapy plan consistent
with the Diamond Concept. In 32 cases (64%), a change in the osteosynthesis
to an angular stable locking compression plate was performed. According
to the individual risk an additional bone graft and/or bone morphogenetic
protein-7 (BMP-7) were applied. A successful consolidation of the nonunion was observed in 37
cases (80.4%) with a median healing time of six months (IQR 6).
Younger patients showed significantly better consolidation. Four
patients were lost to follow-up. Revision was necessary in a total
of eight (16%) cases. In the initial treatment, intramedullary nailing
was most common. Methods
Results
Clinical studies of patients with bone sarcomas have been challenged
by insufficient numbers at individual centres to draw valid conclusions.
Our objective was to assess the feasibility of conducting a definitive
multi-centre randomised controlled trial (RCT) to determine whether
a five-day regimen of post-operative antibiotics, in comparison
to a
24-hour regimen, decreases surgical site infections in patients
undergoing endoprosthetic reconstruction for lower extremity primary
bone tumours. We performed a pilot international multi-centre RCT. We used
central randomisation to conceal treatment allocation and sham antibiotics
to blind participants, surgeons, and data collectors. We determined
feasibility by measuring patient enrolment, completeness of follow-up,
and protocol deviations for the antibiotic regimens. Objective
Methods
The August 2015 Children’s orthopaedics Roundup360 looks at: Learning the Pavlik; MRI and patellar instability; Cerebral palsy and hip dysplasia; ‘Pick your poison’: elastic nailing under the spotlight; Club feet and surgery; Donor site morbidity in vascularised fibular grafting; Cartilage biochemistry with hip dysplasia; SUFE and hip decompression: a good option?
Adverse reaction to wear and corrosion debris
is a cause for concern in total hip arthroplasty (THA). Modular junctions
are a potential source of such wear products and are associated
with secondary pseudotumour formation. We present a consecutive series of 17 patients treated at our
unit for this complication following metal-on-highly cross-linked
polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as
infection, and present the aggregate laboratory results and pathological
findings in this series. The clinical presentation was pain, swelling or instability.
Solid, cystic and mixed soft-tissue lesions were noted on imaging
and confirmed intra-operatively. Corrosion at the head–neck junction
was noted in all cases. No bacteria were isolated on multiple pre-
and intra-operative samples yet the mean erythrocyte sedimentation
rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and
stromal polymorphonuclear cell counts were noted in nine cases. Adverse soft–tissue reactions can occur in MoP THA owing to corrosion
products released from the head–neck junction. The diagnosis should
be carefully considered when investigating pain after THA. This
may avoid the misdiagnosis of periprosthetic infection with an unidentified
organism and mitigate the unnecessary management of these cases
with complete single- or two-stage exchange. Cite this article:
In this study we quantified and characterised
the return of functional mobility following open tibial fracture
using the Hamlyn Mobility Score. A total of 20 patients who had
undergone reconstruction following this fracture were reviewed at
three-month intervals for one year. An ear-worn movement sensor
was used to assess their mobility and gait. The Hamlyn Mobility
Score and its constituent kinematic features were calculated longitudinally,
allowing analysis of mobility during recovery and between patients
with varying grades of fracture. The mean score improved throughout
the study period. Patients with more severe fractures recovered
at a slower rate; those with a grade I Gustilo-Anderson fracture
completing most of their recovery within three months, those with
a grade II fracture within six months and those with a grade III
fracture within nine months. Analysis of gait showed that the quality of walking continued
to improve up to 12 months post-operatively, whereas the capacity
to walk, as measured by the six-minute walking test, plateaued after
six months. Late complications occurred in two patients, in whom the trajectory
of recovery deviated by >
0.5 standard deviations below that of
the remaining patients. This is the first objective, longitudinal
assessment of functional recovery in patients with an open tibial
fracture, providing some clarification of the differences in prognosis
and recovery associated with different grades of fracture. Cite this article:
Tribocorrosion at the head–neck taper interface
– so-called ‘taperosis’ – may be a source of metal ions and particulate
debris in metal-on-polyethylene total hip arthroplasty (THA). We examined the effect of femoral head length on fretting and
corrosion in retrieved head–neck tapers Head length was observed to affect fretting (p = 0.03), with
28 mm + 8 mm femoral heads showing greater total fretting scores
than all other head lengths. The central zone of the femoral head
bore taper was subject to increased fretting damage (p = 0.01),
regardless of head length or stem offset. High-offset femoral stems
were associated with greater total fretting of the bore taper (p
= 0.04). Increased fretting damage is seen with longer head lengths and
high-offset femoral stems, and occurs within a central concentric
zone of the femoral head bore taper. Further investigation is required
to determine the effect of increased head size, and variations in
head–neck taper design. Cite this article:
Only limited data are available regarding the
infiltration of local anaesthetic for total hip arthroplasty (THA),
and no studies were performed for THA using the anterior approach. In this prospective, randomised placebo-controlled study we investigated
the effect of both standard and reverse infiltration of local anaesthetic
in combination with the anterior approach for THA. The primary endpoint
was the mean numeric rating score for pain four hours post-operatively.
In addition, we recorded the length of hospital stay, the operating
time, the destination of the patient at discharge, the use of pain
medication, the occurrence of side effects and pain scores at various
times post-operatively. Between November 2012 and January 2014, 75 patients were included
in the study. They were randomised into three groups: standard infiltration
of local anaesthetic, reversed infiltration of local anaesthetic,
and placebo. There was no difference in mean numeric rating score
for pain four hours post-operatively (p = 0.87). There were significantly
more side effects at one and eight hours post-operatively in the
placebo group (p = 0.02; p = 0.03), but this did not influence the
mobilisation of the patients. There were no differences in all other
outcomes between the groups. We found no clinically relevant effect when the infiltration
of local anaesthetic with ropivacaine and epinephrine was used in
a multimodal pain protocol for THA using the anterior approach. Cite this article:
We report the clinical and radiographic outcomes
of 208 consecutive femoral revision arthroplasties performed in 202
patients (119 women, 83 men) between March 1991 and December 2007
using the X-change Femoral Revision System, fresh-frozen morcellised
allograft and a cemented polished Exeter stem. All patients were
followed prospectively. The mean age of the patients at revision
was 65 years (30 to 86). At final review in December 2013 a total
of 130 patients with 135 reconstructions (64.9%) were alive and
had a non re-revised femoral component after a mean follow-up of
10.6 years (4.7 to 20.9). One patient was lost to follow-up at six
years, and their data were included up to this point.
Re-operation for any reason was performed in 33 hips (15.9%), in
13 of which the femoral component was re-revised (6.3%). The mean
pre-operative Harris hip score was 52 (19 to 95) (n = 73) and improved
to 80 (22 to 100) (n = 161) by the last follow-up. Kaplan–Meier
survival with femoral re-revision for any reason as the endpoint
was 94.9% (95% confidence intervals (CI) 90.2 to 97.4) at ten years;
with femoral re-revision for aseptic loosening as the endpoint it was
99.4% (95% CI 95.7 to 99.9); with femoral re-operation for any reason
as the endpoint it was 84.5% (95% CI 78.3 to 89.1); and with subsidence ≥ 5
mm it was 87.3% (95% CI 80.5 to 91.8). Femoral revision with the
use of impaction allograft bone grafting and a cemented polished
stem results in a satisfying survival rate at a mean of ten years’ follow-up. Cite this article:
We define the long-term outcomes and rates of
further operative intervention following displaced Bennett’s fractures
treated with Kirschner (K-) wire fixation between 1996 and 2009.
We retrospectively identified 143 patients (127 men and 16 women)
with a mean age at the time of injury of 33.2 years (18 to 75).
Electronic records were examined and patients were invited to complete
the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire
in addition to a satisfaction questionnaire. The time since injury
was a mean of 11.5 years (3.4 to 18.5). In total 11 patients had
died, one had developed dementia and 12 patients were lost to follow-up.
This left 119 patients available for recruitment. Of these, 57 did
not respond, leaving a study group of 62 patients. Patients reported
excellent functional outcomes and high levels of satisfaction at
follow-up. Median satisfaction was 94% (interquartile range 91.5
to 97.5) and the mean DASH score was 3.0 (0 to 38). None of the patients
had undergone salvage procedures and none of the responders had
changed occupation or sporting activities. Long-term patient reported
outcomes following displaced Bennett’s fractures treated by closed
reduction and K-wire fixation show excellent functional results
and a high level of patient satisfaction. The rate of infection
is low and similar to other surgical procedures with percutaneous
K-wires. Cite this article: