Advertisement for orthosearch.org.uk
Results 361 - 380 of 2263
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 92 - 95
1 Jan 2019
Harris IA Cuthbert A de Steiger R Lewis P Graves SE

Aims

Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or total hip arthroplasty (THA), with recent recommendations advising that THA be used in community-ambulant patients. This study aims to determine the association between the proportion of FNF treated with THA and year of surgery, day of the week, surgeon practice, and private versus public hospitals, adjusting for known confounders.

Patients and Methods

Data from 67 620 patients in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1999 to 2016 inclusive were used to generate unadjusted and adjusted analyses of the associations between patient, time, surgeon and institution factors, and the proportion of FNF treated with THA.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 55 - 62
1 Jan 2019
Rombach I Merritt N Shirkey BA Rees JL Cook JA Cooper C Carr AJ Beard DJ Gray AM

Aims

The aims of this study were to compare the use of resources, costs, and quality of life outcomes associated with subacromial decompression, arthroscopy only (placebo surgery), and no treatment for subacromial pain in the United Kingdom National Health Service (NHS), and to estimate their cost-effectiveness.

Patients and Methods

The use of resources, costs, and quality-adjusted life-years (QALYs) were assessed in the trial at six months and one year. Results were extrapolated to two years after randomization. Differences between treatment arms, based on the intention-to-treat principle, were adjusted for covariates and missing data were handled using multiple imputation. Incremental cost-effectiveness ratios were calculated, with uncertainty around the values estimated using bootstrapping.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 63 - 67
1 Jan 2019
Erickson BJ Ling D Wong A Eno JJ Dines JS Dines DM Gulotta LV

Aims

The number of rotator cuff repairs that are undertaken is increasing. Reverse shoulder arthroplasty (RSA) is the procedure of choice for patients with rotator cuff arthropathy. We sought to determine whether patients who underwent rotator cuff repair and subsequent RSA had different outcomes compared with a matched control group who underwent RSA without a previous rotator cuff repair.

Patients and Methods

All patients with a history of rotator cuff repair who underwent RSA between 2000 and 2015 with a minimum follow-up of two years were eligible for inclusion as the study group. Outcomes, including the American Shoulder and Elbow Surgeons (ASES) scores, were compared with a matched control group of patients who underwent RSA without having previously undergone rotator cuff repair.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 83 - 91
1 Jan 2019
Whitehouse MR Berstock JR Kelly MB Gregson CL Judge A Sayers A Chesser TJ

Aims

The aim of this study was to investigate the association between the type of operation used to treat a trochanteric fracture of the hip and 30-day mortality.

Patients and Methods

Data on 82 990 patients from the National Hip Fracture Database were analyzed using generalized linear models with incremental case-mix adjustment for patient, non-surgical and surgical characteristics, and socioeconomic factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 4 | Pages 498 - 503
1 May 2004
Wroblewski BM Siney PB Fleming PA

Since wear and loosening of the ultra-high-molecular-weight polyethylene cup are factors which limit the life of an arthroplasty we have attempted to identify factors associated with either low wear (0.02 mm/year or less) or high wear (0.2 mm/year or more). In a series of 1434 Charnley low-friction arthroplasties (1092 patients) 190 (13.2%) showed low wear while 149 (10.4%) showed high wear. We used chi-squared test to assess the significance of various factors. The significant factors of the low-wear group were female gender (p = 0.042), rheumatoid arthritis (p = 0.014), Charnley grade C (p = 0.03) and varus position of the stem (p = 0.003). The use of acetabular cement pressurisation (p = 0.07) and medialisation of the cup (p = 0.07) approached significance. In the high-wear group there was a predominance of men (p = 0.042) with osteoarthritis (p = 0.006) as the underlying hip pathology, and the stem in a valgus position (p = 0.023). Support of the cup by the rim of the acetabulum approached significance (p = 0.07). There was no statistical significance between the two groups for revision for aseptic loosening of the stem or fracture of the stem (p = 0.49). There was a highly significant difference (p < 0.0001) between the two groups for revision for wear and aseptic loosening of the cup, 5.3% compared with 39%. Changes in the cup geometry are probably sufficient to explain the increasing incidence of loosening and revisions with the increasing depth of penetration of the cup. There is much to be gained from the use of a low-wearing ceramic-ultra-high-molecular-weight combination. Tissue reaction to the polyethylene particles cannot be the cause of aseptic loosening of the stem


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1434 - 1441
1 Nov 2018
Blakeney WG Beaulieu Y Puliero B Lavigne M Roy A Massé V Vendittoli P

Aims

This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing.

Patients and Methods

Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 259 - 263
1 Mar 1998
Moore KD Goss K Anglen JO

We report a prospective, randomised, blinded clinical comparison of the use of indomethacin or radiation therapy for the prevention of heterotopic ossification (HO) in 75 adults who had open reduction and internal fixation of acetabular fractures through either a Kocher-Langenbeck, a combined ilioinguinal and Kocher-Langenbeck, or an extended iliofemoral approach. Indomethacin, 25 mg, was given three times daily for six weeks. Radiation with 800 cGy was delivered within three days of operation. Plain radiographs were reviewed and given Brooker classification scores by three independent observers who were unaware of the method of prophylaxis. One patient died from unrelated causes and two were lost to follow-up, leaving 72, 33 in the radiation group and 39 in the indomethacin group, available for evaluation at a mean of 12 months (6 to 48). There was no significant difference in the two groups in terms of age, gender, injury severity score, estimated blood loss, delay to surgery, head injury, presence of femoral head dislocation, or operating time, and no complications due to either method of treatment. The final extent of HO was already present by six weeks in all patients who were followed up. Three patients in the radiation group and five who received indomethacin developed HO of Brooker grade III. Two patients in the indomethacin group developed Brooker IV changes; both had failed to receive proper doses of the drug. Cochran-Armitage analysis showed no significant difference between the two treatment groups as regards the formation of HO. Indomethacin and single-dose radiation therapy are both safe and effective for the prevention of HO after operation for acetabular fractures. Radiation therapy is, however, approximately 200 times more expensive than indomethacin therapy at our institution and has other risks


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1592 - 1599
1 Dec 2018
Galea VP Connelly JW Shareghi B Kärrholm J Sköldenberg O Salemyr M Laursen MB Muratoglu O Bragdon C Malchau H

Aims

The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure.

Patients and Methods

A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1477 - 1481
1 Nov 2018
Larsen P Rathleff MS Østgaard SE Johansen MB Elsøe R

Aims

The aim of this study was to investigate the incidence of knee arthroplasty and arthroscopy following patellar fractures, and to compare this with an age- and gender-matched group without a prior patellar fracture.

Patients and Methods

A national matched cohort study based on the Danish National Patient Register including all citizens of Denmark (approximately 5.3 million) was undertaken. A total of 6096 patients who sustained a patellar fracture in Denmark between 1 January 1996 and 31 December 2000 were included. The median age of these patients was 50.6 years (interquartile range (IQR) 28.5 to 68.9); 49.1% were women. Patients were followed-up until 31 December 2015, with regard to treatment with knee arthroplasty and/or knee arthroscopy.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 372 - 377
1 Apr 2019
Zagra L Villa F Cappelletti L Gallazzi E Materazzi G De Vecchi E

Aims

Leucocyte esterase (LE) has been shown to be an accurate marker of prosthetic joint infection (PJI), and has been proposed as an alternative to frozen section (FS) histology for intraoperative diagnosis. In this study, the intraoperative assessment of LE was compared with FS histology for the diagnosis of prosthetic hip infection.

Patients and Methods

A total of 119 patients undergoing revision total hip arthroplasty (THA) between June 2015 and December 2017 were included in the study. There were 56 men and 63 women with a mean age of 66.2 years (27 to 88). Synovial fluid was collected before arthrotomy for the assessment of LE using enzymatic colourimetric strips. Between five and six samples were stained with haematoxylin and eosin for FS histology, and considered suggestive of infection when at least five polymorphonuclear leucocytes were found in five high-power fields.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 96 - 103
1 Jan 2019
Colo E Leenders LAM Rijnen WHC Schreurs BW Hannink G

Aims

The aim of this study was to analyze the effect of a lateral rim mesh on the survival of primary total hip arthroplasty (THA) in young patients, aged 50 years or younger.

Patients and Methods

We compared a study group of 235 patients (257 hips) who received a primary THA with the use of impaction bone grafting (IBG) with an additional lateral rim mesh with a group of 306 patients (343 hips) who received IBG in the absence of a lateral rim mesh during the same period from 1988 to 2015. In the mesh group, there were 74 male and 183 female patients, with a mean age of 35 years (13 to 50). In the no-mesh group, there were 173 male and 170 female patients, with a mean age of 38 years (12.6 to 50). Cox regression analyses were performed to study the effect of a lateral rim mesh on acetabular component survival. Kaplan–Meier analyses with 95% confidence intervals (CIs) were performed to estimate the survival of the acetabular implant.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 447 - 453
1 Apr 2019
Sanders FRK Backes M Dingemans SA Hoogendoorn JM Schep NWL Vermeulen J Goslings JC Schepers T

Aims

The aim of this study was to evaluate the functional outcome in patients undergoing implant removal (IR) after fracture fixation below the level of the knee.

Patients and Methods

All adult patients (18 to 75 years) undergoing IR after fracture fixation below the level of the knee between November 2014 and September 2016 were included as part of the WIFI (Wound Infections Following Implant Removal Below the Knee) trial, performed in 17 teaching hospitals and two university hospitals in The Netherlands. In this multicentre prospective cohort, the primary outcome was the difference in functional status before and after IR, measured by the Lower Extremity Functional Scale (LEFS), with a minimal clinically important difference of nine points.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 34 - 40
1 Jan 2019
Kraus Schmitz J Lindgren V Janarv P Forssblad M Stålman A

Aims

The aim of this study was to investigate the incidence, risk factors, and outcome of venous thromboembolism (VTE) following anterior cruciate ligament (ACL) reconstruction in a nationwide cohort.

Patients and Methods

All ACL reconstructions, primary and revision, that were recorded in the Swedish Knee Ligament Register (SKLR) between 2006 and 2013 were linked with data from the Swedish National Board of Health and Welfare. The incidence of VTE was determined by entries between the day of surgery until 90 days postoperatively based on diagnosis codes and the prescription of anticoagulants. Risk factors, outcome, and the use of thromboprophylaxis were analyzed. Descriptive statistics with multivariate analysis were used to describe the findings.


Bone & Joint Research
Vol. 7, Issue 10 | Pages 570 - 579
1 Oct 2018
Kallala R Harris WE Ibrahim M Dipane M McPherson E

Aims

Calcium sulphate has traditionally been used as a filler of dead space arising during surgery. Various complications have been described following the use of Stimulan bio-absorbable calcium sulphate beads. This study is a prospective observational study to assess the safety profile of these beads when used in revision arthroplasty, comparing the complication rates with those reported in the literature.

Methods

A total of 755 patients who underwent 456 revision total knee arthroplasties (TKA) and 299 revision total hip arthroplasties (THA), with a mean follow-up of 35 months (0 to 78) were included in the study.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1565 - 1571
1 Dec 2018
Kristensen TB Dybvik E Furnes O Engesæter LB Gjertsen J

Aims

The aim of this large registry-based study was to compare mid-term survival rates of cemented femoral stems of different designs used in hemiarthroplasty for a fracture of the femoral neck.

Patients and Methods

From the Norwegian Hip Fracture Register (NHFR), 20 532 primary cemented bipolar hemiarthroplasties, which were undertaken in patients aged > 70 years with a femoral neck fracture between 2005 and 2016, were included. Polished tapered stems (n = 12 065) (Exeter and CPT), straight stems (n = 5545) (Charnley, Charnley Modular, and Spectron EF), and anatomical stems (n = 2922) (Lubinus SP2) were included. The survival of the implant with any reoperation as the endpoint was calculated using the Kaplan–Meier method and hazard ratios (HRs), and the different indications for reoperation were calculated using Cox regression analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 40 - 47
1 Jul 2019
Sporer S MacLean L Burger A Moric M

Aims

Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone.

Patients and Methods

A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 75 - 82
1 Jan 2019
Kim J Lee SY Jung JH Kim SW Oh J Park MS Chang H Kim T

Aims

The aim of this study was to evaluate the outcome of spinal instrumentation in haemodialyzed patients with native pyogenic spondylodiscitis. Spinal instrumentation in these patients can be dangerous due to rates of complications and mortality, and biofilm formation on the instrumentation.

Patients and Methods

A total of 134 haemodialyzed patients aged more than 50 years who underwent surgical treatment for pyogenic spondylodiscitis were included in the study. Their mean age was 66.4 years (50 to 83); 66 were male (49.3%) and 68 were female (50.7%). They were divided into two groups according to whether spinal instrumentation was used or not. Propensity score matching was used to attenuate the potential selection bias. The outcome of treatment was compared between these two groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 590 - 595
1 Jul 1997
Espehaug B Engesaeter LB Vollset SE Havelin LI Langeland N

We have assessed the effect of different regimes of antibiotic prophylaxis on the survival of total hip implants, comparing antibiotics administered both systemically and in the bone cement, systemically only, in the bone cement only and with no antibiotics given. We studied 10 905 primary cemented total hip replacements, performed for osteoarthritis of the hip and reported to the Norwegian arthroplasty register between 1987 and 1995. Cox-estimated failure-rate ratios (FRR) are presented with adjustment for gender, age, the brand of cement, the prosthesis, the type of operating theatre and the operating time. For revisions performed for infection (39 operations), the lowest rate of revision was found among patients receiving antibiotic-containing cement plus systemic antibiotics (n = 5804). The revision rate for the 4586 patients receiving systemic antibiotics only was 4.3 times greater (95% CI 1.7 to 11.0, p = 0.001); in 239 with antibiotics in the bone cement only it was 6.3 times greater (CI 1.6 to 25.0, p = 0.003); and in the 276 who did not receive antibiotics it was by 11.5 times greater (CI 2.1 to 63.0, p = 0.002). Adjustment for the total amount of systemic antibiotic administered did not change the results. We also observed an increased revision rate for aseptic loosening (109 operations) comparing the systemic-only (FRR = 1.8, CI 1.1 to 2.9, p = 0.01) and the cement-only regimes (FRR = 2.6, CI 1.2 to 5.9, p = 0.02) with the combined dosage. Our findings show that systemic antibiotics combined with antibiotic-containing bone cement led to fewer revisions than the other methods


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1633 - 1639
1 Dec 2018
Zhao Z Yan T Guo W Yang R Tang X Yang Y

Aims

We retrospectively report our experience of managing 30 patients with a primary malignant tumour of the distal tibia; 25 were treated by limb salvage surgery and five by amputation. We compared the clinical outcomes of following the use of different methods of reconstruction.

Patients and Methods

There were 19 male and 11 female patients. The mean age of the patients was 19 years (6 to 59) and the mean follow-up was 5.1 years (1.25 to 12.58). Massive allograft was used in 11 patients, and autograft was used in 14 patients. The time to union, the survival time of the reconstruction, complication rate, and functional outcomes following the different surgical techniques were compared. The overall patient survival was also recorded.


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1310 - 1319
1 Oct 2018
Langton DJ Wells SR Joyce TJ Bowsher JG Deehan D Green S Nargol AVF Holland JP

Aims

There are limited published data detailing the volumetric material loss from tapers of conventional metal-on-polyethylene (MoP) total hip arthroplasties (THAs). Our aim was to address this by comparing the taper wear rates measured in an explanted cohort of the widely used Exeter THA with those measured in a group of metal-on-metal (MoM) THAs.

Patients and Methods

We examined an existing retrieval database to identify all Exeter V40 and Universal MoP THAs. Volumetric wear analysis of the taper surfaces was conducted using previously validated methodology. These values were compared with those obtained from a series of MoM THAs using non-parametric statistical methodology. A number of patient and device variables were accounted for using multiple regression modelling.