The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1335 - 1340
1 Oct 2009
Kontakis GM Tosounidis TI Christoforakis Z Hadjipavlou AG

We reviewed the outcome of 28 patients who had been treated using the Aequalis fracture prosthesis for an acute fracture of the proximal humerus at a mean follow-up of 39.3 months (24 to 63). The mean age of the patients at the time of the fracture was 66.3 years (38 to 80). The mean Constant score was 68.2 (37 to 84) for the operated shoulder, which represented 89.5% of the mean score for the uninjured side (p < 0.001). The quality of the reconstruction as shown on the immediate post-operative radiographs was categorised into three types, anatomical, acceptable, and unacceptable, depending on the position of the tuberosities relative to the prosthetic head and the humeral shaft. Anatomical reconstruction was associated with a higher mean Constant score as well as higher mean values of anterior forward elevation, abduction and external rotation than the other types, but the differences were not statistically significant (p > 0.231). A total of 18 patients had active anterior elevation ≥150°. Their mean active abduction and external rotation were 163.6° and 31.3°, respectively. In seven of the 28 patients, the mean active anterior elevation, abduction and external rotation were 130.7°, 129.2° and 22.8°, respectively. In all, 12 patients were very satisfied with the results, 12 were satisfied, two were dissatisfied and two were disappointed; 26 reported no or only mild pain while only two had moderate pain. In five patients proximal migration of the humeral head was shown on the anteroposterior radiographs of the shoulder. No evidence of loosening was found in any prosthesis


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 842 - 848
1 Aug 2024
Kriechling P Whitefield R Makaram NS Brown IDM Mackenzie SP Robinson CM

Aims

Vascular compromise due to arterial injury is a rare but serious complication of a proximal humeral fracture. The aims of this study were to report its incidence in a large urban population, and to identify clinical and radiological factors which are associated with this complication. We also evaluated the results of the use of our protocol for the management of these injuries.

Methods

A total of 3,497 adult patients with a proximal humeral fracture were managed between January 2015 and December 2022 in a single tertiary trauma centre. Their mean age was 66.7 years (18 to 103) and 2,510 (72%) were female. We compared the demographic data, clinical features, and configuration of those whose fracture was complicated by vascular compromise with those of the remaining patients. The incidence of vascular compromise was calculated from national population data, and predictive factors for its occurrence were investigated using univariate analysis.


The Bone & Joint Journal
Vol. 106-B, Issue 11 | Pages 1348 - 1360
1 Nov 2024
Spek RWA Smith WJ Sverdlov M Broos S Zhao Y Liao Z Verjans JW Prijs J To M Åberg H Chiri W IJpma FFA Jadav B White J Bain GI Jutte PC van den Bekerom MPJ Jaarsma RL Doornberg JN

Aims

The purpose of this study was to develop a convolutional neural network (CNN) for fracture detection, classification, and identification of greater tuberosity displacement ≥ 1 cm, neck-shaft angle (NSA) ≤ 100°, shaft translation, and articular fracture involvement, on plain radiographs.

Methods

The CNN was trained and tested on radiographs sourced from 11 hospitals in Australia and externally validated on radiographs from the Netherlands. Each radiograph was paired with corresponding CT scans to serve as the reference standard based on dual independent evaluation by trained researchers and attending orthopaedic surgeons. Presence of a fracture, classification (non- to minimally displaced; two-part, multipart, and glenohumeral dislocation), and four characteristics were determined on 2D and 3D CT scans and subsequently allocated to each series of radiographs. Fracture characteristics included greater tuberosity displacement ≥ 1 cm, NSA ≤ 100°, shaft translation (0% to < 75%, 75% to 95%, > 95%), and the extent of articular involvement (0% to < 15%, 15% to 35%, or > 35%).


Bone & Joint Open
Vol. 5, Issue 10 | Pages 929 - 936
22 Oct 2024
Gutierrez-Naranjo JM Salazar LM Kanawade VA Abdel Fatah EE Mahfouz M Brady NW Dutta AK

Aims

This study aims to describe a new method that may be used as a supplement to evaluate humeral rotational alignment during intramedullary nail (IMN) insertion using the profile of the perpendicular peak of the greater tuberosity and its relation to the transepicondylar axis. We called this angle the greater tuberosity version angle (GTVA).

Methods

This study analyzed 506 cadaveric humeri of adult patients. All humeri were CT scanned using 0.625 × 0.625 × 0.625 mm cubic voxels. The images acquired were used to generate 3D surface models of the humerus. Next, 3D landmarks were automatically calculated on each 3D bone using custom-written C++ software. The anatomical landmarks analyzed were the transepicondylar axis, the humerus anatomical axis, and the peak of the perpendicular axis of the greater tuberosity. Lastly, the angle between the transepicondylar axis and the greater tuberosity axis was calculated and defined as the GTVA.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 702 - 705
1 Sep 1996
Kenan S Abdelwahab IF Hermann G Klein M Pastores G

We report a unique case of juxtacortical osteoblastoma of the humeral shaft, which simulated the appearance of an extraosseous extension of Gaucher-cell deposits. The tumour was treated successfully by curettage and bone grafting. We can find no previous report of this association between osteoblastoma and Gaucher’s disease


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 804 - 807
1 Sep 1993
Wright T Miller G Vander Griend R Wheeler D Dell P

Nine patients with nonunited humeral shaft fractures were treated by open reduction and internal fixation with an intramedullary fibular bone graft and a compression plate. Fixation of the screws was enhanced by passing them through the fibula as well as the two humeral cortices (quadricortical fixation). Eight of the nine fractures united at an average of 3.5 months. Tests on cadaver bones showed that quadricortical fixation was as strong as methylmethacrylate augmentation and significantly better than bicortical fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 238 - 240
1 May 1975
Campbell J Almond HGA Johnson R

An elderly woman presented with a pathological fracture of the right humerus. Progressive dissolution of the shaft of this bone took place over six months. No cause could be established and the patient refused biopsy. With only simple splintage for treatment the humeral shaft gradually reformed and re-ossified over a period of two years. The patient has been under review for four and a half years and no further pathology has come to light. The cause of the osteolysis remains obscure


Bone & Joint Research
Vol. 11, Issue 11 | Pages 814 - 825
14 Nov 2022
Ponkilainen V Kuitunen I Liukkonen R Vaajala M Reito A Uimonen M

Aims

The aim of this systematic review and meta-analysis was to gather epidemiological information on selected musculoskeletal injuries and to provide pooled injury-specific incidence rates.

Methods

PubMed (National Library of Medicine) and Scopus (Elsevier) databases were searched. Articles were eligible for inclusion if they reported incidence rate (or count with population at risk), contained data on adult population, and were written in English language. The number of cases and population at risk were collected, and the pooled incidence rates (per 100,000 person-years) with 95% confidence intervals (CIs) were calculated by using either a fixed or random effects model.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 755 - 757
1 Nov 1986
Worlock P

A simple method of radiological assessment has been used to measure the angle between the long axis of the humeral shaft and the growth plate of the capitellum (the Baumann angle). In the normal arm a significant relationship was found between the Baumann angle and the carrying angle. The Baumann angle was also measured after reduction of supracondylar fractures of the humerus and was found to correlate well with the final carrying angle measured at follow-up. There was no significant difference between the Baumann angle after reduction and that measured at follow-up; and it is suggested that this angle after reduction can be reliably used to predict accurately the final carrying angle


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 74 - 77
1 Jan 2003
Simonis RB Nuñez VA Khaleel A

Between 1993 and 2000 we treated 14 patients with nonunion of fractures of the distal humerus; 11 had already had previous fixation which had failed. The mean time to surgery was 21 months after injury. All the fractures were very low which made it difficult to obtain a firm hold of the small distal fragment. The problem of fixation was addressed by inserting a Coventry infant hip screw into the humeral condyles. The screw has a thread of wide diameter which gives excellent purchase on the small distal fragment. The condyles can then be compressed on to the humeral shaft using a 4.5 mm narrow tibial dynamic plate. Of these 14 difficult cases of nonunion, 12 progressed to union


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1403 - 1409
1 Oct 2010
Pape G Zeifang F Bruckner T Raiss P Rickert M Loew M

Fractures of the proximal humerus can lead to malalignment of the humeral head, necrosis and post-traumatic osteoarthritis. In such cases surface replacement might be a promising option. A total of 28 shoulders with glenohumeral arthritis subsequent to a fracture underwent surface replacement arthroplasty of the humeral head in patients with a mean age of 60 years (35 to 83). On the basis of the inclination of the impacted head, post-traumatic arthritis was divided into three types: type 1, an impacted fracture of the head in an anatomical position (seven cases); type 2, a valgus impacted fracture (13 cases); type 3, a varus impacted fracture (eight cases). The outcome was measured by means of the Constant score. According to the Boileau classification of the sequelae of fractures of the proximal humerus, all 28 patients had a final result of intra-capsular category 1. The mean Constant score for the 28 shoulders increased from 23.2 points (2 to 45) pre-operatively to 55.1 points (20 to 89) at a mean of 31 months (24 to 66) post-operatively. Valgus impacted fractures had significantly better results (p < 0.039). Surface replacement arthroplasty can provide good results for patients with post-traumatic osteoarthritis of the shoulder. Their use avoids post-operative complications of the humeral shaft, such as peri-prosthetic fractures. Further surgery can be undertaken more easily as the bone stock is preserved


Bone & Joint 360
Vol. 13, Issue 5 | Pages 34 - 37
1 Oct 2024

The October 2024 Shoulder & Elbow Roundup360 looks at: Proximal humeral fractures with vascular compromise; Outcomes and challenges of revision arthroscopic rotator cuff repair: a systematic review; Evaluating treatment effectiveness for lateral elbow tendinopathy: a systematic review and network meta-analysis; Tendon transfer techniques for irreparable subscapularis tears: a comparative review; Impact of subscapularis repair in reverse shoulder arthroplasty; Isolated subscapularis tears strongly linked to shoulder pseudoparesis; Nexel and Coonrad-Morrey total elbow arthroplasties show comparable revision rates in New Zealand study; 3D MRI matches 3D CT in assessing bone loss and shoulder morphology in dislocation cases.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 31 - 35
2 Aug 2024

The August 2024 Trauma Roundup360 looks at: Does topical vancomycin prevent fracture-related infections in closed fractures undergoing open reduction and internal fixation? A randomized controlled trial; Is postoperative splinting advantageous after upper limb fracture surgery?; Does suprapatellar nailing resolve knee pain?; Locking versus non-locking plate fixation in comminuted talar neck fractures: a biomechanical study using cadaveric specimens; Revolutionizing recovery metrics: PROMIS versus SMFA in orthopaedic trauma care; Dorsal hook plating of patella fractures: reliable fixation and satisfactory outcomes; The impact of obesity on subtrochanteric femur fracture outcomes; Low-dose NSAIDs (ketorolac) and cytokine modulation in orthopaedic polytrauma: a detailed analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 1 | Pages 105 - 111
1 Feb 1966
Klenerman L

1. It appears that fracture of the humeral shaft occurs more often in persons over fifty. This incidence corresponds with that found in a study carried out by the Pennsylvania Orthopaedic Society in 1959. 2. The middle third of the bone is the most vulnerable portion of the shaft, where transverse fracture and radial nerve palsy most commonly occur. 3. Most fractures of the shaft of the humerus are best treated by simple splintage. The degree of radiological deformity that can be accepted is far greater than in other long bones. In this group anterior bowing of 20 degrees or varus of 30 degrees was present before it became clinically obvious and even then the function of the limb was good. 4. Internal fixation is only occasionally indicated but operation on the middle third of the bone increased the chances of delayed union. 5. In the treatment of delayed union intramedullary fixation and the application of slivers of iliac bone is effective in stimulating the fracture to join


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 646 - 655
1 Jul 2024
Longo UG Gulotta LV De Salvatore S Lalli A Bandini B Giannarelli D Denaro V

Aims

Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures.

Methods

The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims

Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE.

Methods

This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates.


Bone & Joint 360
Vol. 11, Issue 2 | Pages 37 - 41
1 Apr 2022


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 213 - 221
1 Mar 2001
Levy O Copeland SA

Cementless surface replacement arthroplasty of the shoulder is designed to replace the damaged joint surfaces and restore normal anatomy with minimal resection of bone. We have used the Copeland shoulder arthroplasty for 14 years. Between 1986 and 2000, 285 surface replacement arthroplasties were implanted in our unit. The prosthesis has evolved during this time, but the principle of minimal bone resection has remained the same. Between 1990 and 1994, 103 Mark-2 prostheses were inserted into 94 patients (9 bilateral). The operations were carried out for the treatment of osteoarthritis, rheumatoid arthritis, avascular necrosis, instability arthropathy, post-traumatic arthropathy and cuff arthropathy. The mean follow-up was for 6.8 years (5 to 10). The best results were achieved in primary osteoarthritis, with Constant scores of 93.7% for total shoulder replacement and 73.5% for hemiarthroplasty. The poorest results were seen in patients with cuff arthropathy and post-traumatic arthropathy with adjusted Constant scores of 61.3% and 62.7%, respectively. Most patients (93.9%) considered their shoulder to be much better or better than before the operation. Of the 88 humeral implants available for radiological review, 61 (69.3%) showed no evidence of radiolucency, nor did 21 (35.6%) of the 59 glenoid prostheses. Three were definitely loose, and eight shoulders required revision (7.7%), two (1.9%) for primary loosening. The results of this series are comparable with those for stemmed prostheses with a similar follow-up and case mix. The cementless surface replacement arthroplasty diminishes the risk of complications involving the humeral shaft and periprosthetic fractures. Revision or arthrodesis can be undertaken easily since the bone stock has been maintained with no loss of length


Bone & Joint Open
Vol. 5, Issue 10 | Pages 818 - 824
2 Oct 2024
Moroder P Herbst E Pawelke J Lappen S Schulz E

Aims

The liner design is a key determinant of the constraint of a reverse total shoulder arthroplasty (rTSA). The aim of this study was to compare the degree of constraint of rTSA liners between different implant systems.

Methods

An implant company’s independent 3D shoulder arthroplasty planning software (mediCAD 3D shoulder v. 7.0, module v. 2.1.84.173.43) was used to determine the jump height of standard and constrained liners of different sizes (radius of curvature) of all available companies. The obtained parameters were used to calculate the stability ratio (degree of constraint) and angle of coverage (degree of glenosphere coverage by liner) of the different systems. Measurements were independently performed by two raters, and intraclass correlation coefficients were calculated to perform a reliability analysis. Additionally, measurements were compared with parameters provided by the companies themselves, when available, to ensure validity of the software-derived measurements.


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 83 - 90
1 Jan 2022
Batten TJ Gallacher S Evans JP Harding RJ Kitson J Smith CD Thomas WJ

Aims

The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up.

Methods

Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening.