Advertisement for orthosearch.org.uk
Results 21 - 40 of 41
Results per page:
Bone & Joint Research
Vol. 5, Issue 9 | Pages 436 - 441
1 Sep 2016
Pinsornsak P Naratrikun K Kanitnate S Sangkomkamhang T

Objectives

The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee.

Methods

Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis was evaluated using the joint space width and Kellgren-Lawrence (KL) radiographic classification. The t-test was used for statistical analysis.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 628 - 633
1 May 2016
Heijens E Kornherr P Meister C

Aims

In patients undergoing medial opening wedge high tibial osteotomy (MOWHTO), soft tissue opening on the medial side of the knee is difficult to predict. When the load bearing axis is corrected beyond a certain point, the knee joint tilts open on the medial side. We therefore hypothesised that there is a tipping point and defined this as the coronal hypomochlion.

Patients and Methods

In this prospective study of 150 navigated MOWHTOs (144 consecutive patients), data were collected before surgery and at three months post-operatively. In order to calculate the hypomochlion, we compared the respective changes to the joint line convergence angle (JLCA) with the post-operative axis of the leg. The change to the medial proximal tibial angle accounts for only about 80% of the change to the femorotibial angle; 20% of the correction can therefore be attributed to non-osseous, soft-tissue changes.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 9 - 13
1 Jun 2014
Waterson HB Philips JRA Mandalia VI Toms AD

Mechanical alignment has been a fundamental tenet of total knee arthroplasty (TKA) since modern knee replacement surgery was developed in the 1970s. The objective of mechanical alignment was to infer the greatest biomechanical advantage to the implant to prevent early loosening and failure. Over the last 40 years a great deal of innovation in TKA technology has been focusing on how to more accurately achieve mechanical alignment. Recently the concept of mechanical alignment has been challenged, and other alignment philosophies are being explored with the intention of trying to improve patient outcomes following TKA.

This article examines the evolution of the mechanical alignment concept and whether there are any viable alternatives.


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1132 - 1139
1 Sep 2017
Williams N Challoumas D Ketteridge D Cundy PJ Eastwood DM

The mucopolysaccharidoses (MPS) are a group of inherited lysosomal storage disorders with clinical manifestations relevant to the orthopaedic surgeon. Our aim was to review the recent advances in their management and the implications for surgical practice.

The current literature about MPSs is summarised, emphasising orthopaedic complications and their management.

Recent advances in the diagnosis and management of MPSs include the recognition of slowly progressive, late presenting subtypes, developments in life-prolonging systemic treatment and potentially new indications for surgical treatment. The outcomes of surgery in these patients are not yet validated and some procedures have a high rate of complications which differ from those in patients who do not have a MPS.

The diagnosis of a MPS should be considered in adolescents or young adults with a previously unrecognised dysplasia of the hip. Surgeons treating patients with a MPS should report their experience and studies should include the assessment of function and quality of life to guide treatment.

Cite this article: Bone Joint J 2017;99-B:1132–9


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 643 - 648
1 May 2013
Wang J Hsu C Huang C Lin P Chen W

Structural allografts may be used to manage uncontained bone defects in revision total knee replacement (TKR). However, the availability of cadaver grafts is limited in some areas of Asia. The aim of this study was to evaluate the mid-term outcome of the use of femoral head allografts for the reconstruction of uncontained defects in revision TKR, focusing on complications related to the graft.

We retrospectively reviewed 28 patients (30 TKRs) with Anderson Orthopaedic Research Institute (AORI) type 3 bone defects, who underwent revision using femoral head allografts and stemmed components. The mean number of femoral heads used was 1.7 (1 to 3). The allograft–host junctions were packed with cancellous autograft.

At a mean follow-up of 76 months (38 to 136) the mean American Knee Society knee score improved from 37.2 (17 to 60) pre-operatively to 90 (83 to 100) (p < 0.001). The mean function score improved from 26.5 (0 to 50) pre-operatively to 81 (60 to 100) (p < 0.001). All the grafts healed to the host bone. The mean time to healing of the graft was 6.6 months (4 to 16). There have been no complications of collapse of the graft, nonunion, infection or implant loosening. No revision surgery was required.

The use of femoral head allografts in conjunction with a stemmed component and autogenous bone graft in revision TKR in patients with uncontained bone defects resulted in a high rate of healing of the graft with minimal complications and a satisfactory outcome. Longer follow-up is needed to observe the evolution of the graft.

Cite this article: Bone Joint J 2013;95-B:643–8.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 471 - 476
1 Apr 2007
Kim Y Kim J Yoon S

Bilateral sequential total knee replacement was carried out under one anaesthetic in 100 patients. One knee was replaced using a CT-free computer-assisted navigation system and the other conventionally without navigation. The two methods were compared for accuracy of orientation and alignment of the components. There were 85 women and 15 men with a mean age of 67.6 years (54 to 83). Radiological and CT imaging was carried out to determine the alignment of the components. The mean follow-up was 2.3 years (2 to 3).

The operating and tourniquet times were significantly longer in the navigation group (p < 0.001). There were no significant pre- or post-operative differences between the knee scores of the two groups (p = 0.288 and p = 0.429, respectively). The results of imaging and the number of outliers for all radiological parameters were not statistically different (p = 0.109 to p = 0.920).

In this series computer-assisted navigated total knee replacement did not result in more accurate orientation and alignment of the components than that achieved by conventional total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1288 - 1291
1 Sep 2012
Sanghrajka AP Hill RA Murnaghan CF Simpson AHRW Bellemore MC

We describe three cases of infantile tibia vara resulting from an atraumatic slip of the proximal tibial epiphysis upon the metaphysis. There appears to be an association between this condition and severe obesity. Radiologically, the condition is characterised by a dome-shaped metaphysis, an open growth plate and disruption of the continuity between the lateral borders of the epiphysis and metaphysis, with inferomedial translation of the proximal tibial epiphysis. All patients were treated by realignment of the proximal tibia by distraction osteogenesis with an external circulator fixator, and it is suggested that this is the optimal method for correction of this complex deformity. There are differences in the radiological features and management between conventional infantile Blount’s disease and this ‘slipped upper tibial epiphysis’ variant.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 10 | Pages 1324 - 1328
1 Oct 2007
Chang CB Han I Kim SJ Seong SC Kim TK

We investigated the association between the radiological findings and the symptoms arising from the patellofemoral joint in advanced osteoarthritis (OA) of the knee. Four radiological features, joint space narrowing, osteophyte formation, translation of the patella and focal attrition were assessed in 151 consecutive osteoarthritic knees in 107 patients undergoing total knee replacement. The symptoms which were assessed included anterior knee pain which was scored, the ability to rise from a chair and climb stairs, and quadriceps weakness.

Among the radiological features, only patellar translation and obliteration of the joint space had a statistically significant association with anterior knee pain (odds ratio (OR) 4.85; 95% confidence interval (CI) 1.83 to 12.88 and OR 11.23; 95% CI 2.44 to 51.62) respectively. Patellar translation had a statistically significant association with difficulty in rising from a chair (OR 9.06; 95% CI 1.75 to 45.11). Other radiological features, including osteophytes, joint space narrowing, and focal attrition had no significant association.

Our study indicates that the radiological findings of patellar translation and significant loss of cartilage are predictive of patellofemoral symptoms and functional limitation in advanced OA of the knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 188 - 197
1 Feb 2006
Cobb J Henckel J Gomes P Harris S Jakopec M Rodriguez F Barrett A Davies B

We performed a prospective, randomised controlled trial of unicompartmental knee arthroplasty comparing the performance of the Acrobot system with conventional surgery. A total of 27 patients (28 knees) awaiting unicompartmental knee arthroplasty were randomly allocated to have the operation performed conventionally or with the assistance of the Acrobot. The primary outcome measurement was the angle of tibiofemoral alignment in the coronal plane, measured by CT. Other secondary parameters were evaluated and are reported. All of the Acrobot group had tibiofemoral alignment in the coronal plane within 2° of the planned position, while only 40% of the conventional group achieved this level of accuracy. While the operations took longer, no adverse effects were noted, and there was a trend towards improvement in performance with increasing accuracy based on the Western Ontario and McMaster Universities Osteoarthritis Index and American Knee Society scores at six weeks and three months. The Acrobot device allows the surgeon to reproduce a pre-operative plan more reliably than is possible using conventional techniques which may have clinical advantages


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 292 - 299
1 Mar 2015
Karthik K Colegate-Stone T Dasgupta P Tavakkolizadeh A Sinha J

The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.

Cite this article: Bone Joint J 2015; 97-B:292–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1549 - 1556
1 Dec 2006
McDermott ID Amis AA

The menisci of the knee have an important role in load-bearing and shock absorption within the joint. They may also function as secondary stabilisers, have a proprioceptive role, and aid the lubrication and nutrition of the articular cartilage. Complete or partial loss of a meniscus can have damaging effects on a knee, leading to serious long-term sequelae.

This paper reviews the consequences of meniscectomy and summarises the body of evidence in the literature regarding those factors most relevant to long-term outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1296 - 1299
1 Oct 2011
Lang JE Mannava S Floyd AJ Goddard MS Smith BP Mofidi A M. Seyler T Jinnah RH

Robots have been used in surgery since the late 1980s. Orthopaedic surgery began to incorporate robotic technology in 1992, with the introduction of ROBODOC, for the planning and performance of total hip replacement. The use of robotic systems has subsequently increased, with promising short-term radiological outcomes when compared with traditional orthopaedic procedures. Robotic systems can be classified into two categories: autonomous and haptic (or surgeon-guided). Passive surgery systems, which represent a third type of technology, have also been adopted recently by orthopaedic surgeons.

While autonomous systems have fallen out of favour, tactile systems with technological improvements have become widely used. Specifically, the use of tactile and passive robotic systems in unicompartmental knee replacement (UKR) has addressed some of the historical mechanisms of failure of non-robotic UKR. These systems assist with increasing the accuracy of the alignment of the components and produce more consistent ligament balance. Short-term improvements in clinical and radiological outcomes have increased the popularity of robot-assisted UKR.

Robot-assisted orthopaedic surgery has the potential for improving surgical outcomes. We discuss the different types of robotic systems available for use in orthopaedics and consider the indication, contraindications and limitations of these technologies.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 436 - 444
1 Apr 2013
Scott CEH Nutton RW Biant LC

The lateral compartment is predominantly affected in approximately 10% of patients with osteoarthritis of the knee. The anatomy, kinematics and loading during movement differ considerably between medial and lateral compartments of the knee. This in the main explains the relative protection of the lateral compartment compared with the medial compartment in the development of osteoarthritis. The aetiology of lateral compartment osteoarthritis can be idiopathic, usually affecting the femur, or secondary to trauma commonly affecting the tibia. Surgical management of lateral compartment osteoarthritis can include osteotomy, unicompartmental knee replacement and total knee replacement. This review discusses the biomechanics, pathogenesis and development of lateral compartment osteoarthritis and its management.

Cite this article: Bone Joint J 2013;95-B:436–44.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 273 - 276
1 Feb 2010
Ballal MS Bruce CE Nayagam S

A total of 25 children (37 legs and 51 segments) with coronal plane deformities around the knee were treated with the extraperiosteal application of a flexible two-hole plate and screws. The mean age was 11.6 years (5.5 to 14.9), the median angle of deformity treated was 8.3° and mean time for correction was 16.1 months (7 to 37.3). There was a mean rate of correction of 0.7° per month in the femur (0.3° to 1.5°), 0.5° per month in the tibia (0.1° to 0.9°) and 1.2° per month (0.1° to 2.2°) if femur and tibia were treated concurrently. Correction was faster if the child was under 10 years of age (p = 0.05). The patients were reviewed between six and 32 months after plate removal. One child had a rebound deformity but no permanent physeal tethers were encountered.

The guided growth technique, as performed using a flexible titanium plate, is simple and safe for treating periarticular deformities of the leg.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 12 - 18
1 Jan 2011
Eastwood DM Sanghrajka AP

Guiding growth by harnessing the ability of growing bone to undergo plastic deformation is one of the oldest orthopaedic principles. Correction of deformity remains a major part of the workload for paediatric orthopaedic surgeons and recently, along with developments in limb reconstruction and computer-directed frame correction, there has been renewed interest in surgical methods of physeal manipulation or ‘guided growth’. Manipulating natural bone growth to correct a deformity is appealing, as it allows gradual correction by non- or minimally invasive methods.

This paper reviews the techniques employed for guided growth in current orthopaedic practice, including the basic science and recent advances underlying mechanical physeal manipulation of both healthy and pathological physes.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 857 - 862
1 Jul 2014
Abdel MP Oussedik S Parratte S Lustig S Haddad FS

Substantial healthcare resources have been devoted to computer navigation and patient-specific instrumentation systems that improve the reproducibility with which neutral mechanical alignment can be achieved following total knee replacement (TKR). This choice of alignment is based on the long-held tenet that the alignment of the limb post-operatively should be within 3° of a neutral mechanical axis. Several recent studies have demonstrated no significant difference in survivorship when comparing well aligned versus malaligned TKRs. Our aim was to review the anatomical alignment of the knee, the historical and contemporary data on a neutral mechanical axis in TKR, and the feasibility of kinematically-aligned TKRs.

Review of the literature suggests that a neutral mechanical axis remains the optimal guide to alignment.

Cite this article: Bone Joint J 2014;96-B:857–62.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1304 - 1310
1 Oct 2008
Kim T Lee D Bin S

We carried out a prospective study to assess the clinical outcome, complications and survival of the NexGen Legacy posterior-stabilised-Flex total knee replacement (TKR) in a consecutive series of 278 knees between May 2003 and February 2005. Mean follow-up for 259 TKRs (98.2%) was 3.8 years (3.0 to 4.8). Annual follow-up showed improvement in the Knee Society scores (paired t-test, p < 0.05). At the last follow-up, the mean maximum flexion was 135° (110° to 150°). Two knees showed radiolucent lines, but revision was not required because the patients were asymptomatic. Revision was required in one case because of infection, but there were no prosthesis-related revisions. There were no other complications. The estimated survival rate at four years with revision for any reason and prosthesis-related problems was 99.6% and 100%, respectively.

This relatively large study indicates that the legacy posterior stabilised-Flex design provides excellent short-term outcome but warrants ongoing evaluation to confirm the long-term durability and functioning of the implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 9 | Pages 1222 - 1224
1 Sep 2005
Sheng P Jämsen E Lehto MUK Konttinen YT Pajamäki J Halonen P

We report a consecutive series of 16 revision total knee arthroplasties using the Total Condylar III system in 14 patients with inflammatory arthritis which were performed between 1994 and 2000. There were 11 women and three men with a mean age of 59 years (36 to 78). The patients were followed up for 74 months (44 to 122).

The mean pre-operative Knee Society score of 37 points (0 to 77) improved to 88 (61 to 100) at follow-up (t-test, p < 0.001) indicating very good overall results. The mean range of flexion improved from 62° (0° to 120°) to 98° (0° to 145°) (t-test, p < 0.05) allowing the patients to stand from a sitting position. The mean Knee Society pain score improved from 22 (10 to 45) to 44 (20 to 50) (t-test, p < 0.05). No knee had definite loosening, although five showed asymptomatic radiolucent lines. Complications were seen in three cases, comprising patellar pain, patellar fracture and infection.

These results suggest that the Total Condylar III system can be used successfully in revision total knee arthroplasty in inflammatory arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1081 - 1084
1 Aug 2005
Han I Chang CB Lee S Lee MC Seong SC Kim TK

We sought to determine the degree of correlation between the condition of the patellar articular cartilage and patellofemoral symptoms and function in osteoarthritic patients undergoing total knee arthroplasty. The depth of the osteoarthritic lesion, as graded by the Outerbridge classification and its size and location were assessed to determine the condition of the patellar cartilage in 80 consecutive osteoarthritic knees undergoing total knee arthroplasty. The association between the condition of the cartilage and patellofemoral symptoms and function was investigated by correlation analysis.

The depth and size of the lesion had a significant but weak correlation with anterior knee pain (r = −0.300 and −0.289; p = 0.007 and 0.009, respectively), whereas location had no significant association (p > 0.05). None had a significant association with patellofemoral functional parameters (chair-rising, stair-climbing, and quadriceps power) (p > 0.05).

Our study indicates that patellofemoral symptoms and function are not completely determined by the condition of the cartilage. Caution should be taken when the symptoms and functional limitations are attributed to a lesion in the patellofemoral joint in making a decision regarding patellar resurfacing in total knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 141 - 146
1 Nov 2012
Minas T

Hyaline articular cartilage has been known to be a troublesome tissue to repair once damaged. Since the introduction of autologous chondrocyte implantation (ACI) in 1994, a renewed interest in the field of cartilage repair with new repair techniques and the hope for products that are regenerative have blossomed. This article reviews the basic science structure and function of articular cartilage, and techniques that are presently available to effect repair and their expected outcomes.