Advertisement for orthosearch.org.uk
Results 21 - 40 of 79
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 952 - 960
1 Jul 2016
Muderis MA Tetsworth K Khemka A Wilmot S Bosley B Lord SJ Glatt V

Aims. This study describes the Osseointegration Group of Australia’s Accelerated Protocol two-stage strategy (OGAAP-1) for the osseointegrated reconstruction of amputated limbs. Patients and Methods. We report clinical outcomes in 50 unilateral trans-femoral amputees with a mean age of 49.4 years (24 to 73), with a minimum one-year follow-up. Outcome measures included the Questionnaire for persons with a Trans-Femoral Amputation, the health assessment questionnaire Short-Form-36 Health Survey, the Amputation Mobility Predictor scores presented as K-levels, 6 Minute Walk Test and timed up and go tests. Adverse events included soft-tissue problems, infection, fractures and failure of the implant. Results. Our results demonstrated statistically significant improvements in all five outcome measures. A total of 27 patients experienced adverse events but at the conclusion of the study, all 50 were walking on osseointegrated prostheses. Conclusion. These results demonstrate that osseointegrated prostheses are a suitable alternative to socket-fit devices for amputees experiencing socket-related discomfort and that our strategy offers more rapid progress to walking than other similar protocols. Cite this article: Bone Joint J 2016;98-B:952–60


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 649 - 653
1 May 2015
Hawi N Kendoff D Citak M Gehrke T Haasper C

Knee arthrodesis is a potential salvage procedure for limb preservation after failure of total knee arthroplasty (TKA) due to infection. In this study, we evaluated the outcome of single-stage knee arthrodesis using an intramedullary cemented coupled nail without bone-on-bone fusion after failed and infected TKA with extensor mechanism deficiency. Between 2002 and 2012, 27 patients (ten female, 17 male; mean age 68.8 years; 52 to 87) were treated with septic single-stage exchange. Mean follow-up duration was 67.1months (24 to 143, n = 27) (minimum follow-up 24 months) and for patients with a minimum follow-up of five years 104.9 (65 to 143,; n = 13). A subjective patient evaluation (Short Form (SF)-36) was obtained, in addition to the Visual Analogue Scale (VAS). The mean VAS score was 1.44 (SD 1.48). At final follow-up, four patients had recurrent infections after arthrodesis (14.8%). Of these, three patients were treated with a one-stage arthrodesis nail exchange; one of the three patients had an aseptic loosening with a third single-stage exchange, and one patient underwent knee amputation for uncontrolled sepsis at 108 months. All patients, including the amputee, indicated that they would choose arthrodesis again. Data indicate that a single-stage knee arthrodesis offers an acceptable salvage procedure after failed and infected TKA. Cite this article: Bone Joint J 2015;97-B:649–53


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 251 - 254
1 Mar 1988
Millstein S McCowan S Hunter G

A retrospective study of 260 industrial amputees was undertaken to determine the long-term functional results of partial foot amputations following trauma. Follow-up ranged from 1 to 68 years with a mean of 16 years. Of 113 partial foot amputees (118 amputations) who had retained their original amputation, the functional end-results were 43% good, 38% fair and 19% poor. Lisfranc and Chopart amputations were better than those at transmetatarsal or digital levels. Of 260 initial amputations 49 (19%) were revised to a Syme's or a below-knee amputation


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 3 | Pages 482 - 487
1 Aug 1969
Baker GCW Stableforth PG

1. All traceable Syme amputees attending the Edinburgh limb centre have been seen and reviewed. They number sixty-seven. Forty had amputations twenty-five or more years before. 2. There are seventy-one surviving stumps. One has failed. 3. Records of all the below-knee amputees reveal five further failures of Syme stumps. The causes of failure are discussed. 4. Problems in the Syme stump are rare after the first year. The early difficulties are discussed. 5. We conclude that a patient with Syme's amputation can expect his stump to give a lifetime of service


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 269 - 272
1 Feb 2011
Wansbrough G Boyne N Pollard CW

We present a patient who underwent delayed sub-periosteal hemipelvectomy for control of infection and to enable soft-tissue cover after trauma. At four months after amputation, clinical examination and radiographs demonstrated almost complete re-ossification of the hemipelvis. This has allowed the patient to regain sitting balance and to use a walking prosthesis designed for patients following disarticulation of the hip. After 14 months from injury, no perineal hernia has developed, and no dysfunction of pelvic organs is attributable to heterotopic bone formation or adhesions. The patient’s mobility with a prosthesis is similar to that expected of a through-hip amputee


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 552 - 560
1 Nov 1978
Herberts P Almstrom C Caine K

A control system for a multifunctional hand prosthesis, which requires a minimum of training for the amputee, has been developed. The great advantage of the pattern recognition technique in making it possible to control as many as six prosthetic movements has prompted this study. The development of a complete miniaturised system has allowed a clinical trial on four patients. Two different tests have been employed to evaluate this system: an objective computer test and a test representing activities of daily living (ADL test). The computer test shows that a high rate of correct recognition is obtained immediately after the prosthesis is applied to the amputee. The ADL test shows that forearm rotation, and flexion and extension of the wrist are used in most activities, indicating that few compensatory movements are performed. It is suggested that this control system is feasible and that long periods of training are unnecessary


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 417 - 420
1 Nov 1977
Ransford A Hughes S

Twenty patients with complete brachial plexus lesions were reviewed approximately nine and a half years after injury. Thirteen were amputees and seven had received no surgical treatment. Amputation did not alleviate pain and a prosthesis was frequently of no greater use of the patient than the useless limb it replaced: only two of the thirteen amputees were true prosthetic users and they both had dominant limb involvement, the rest adapting easily to being one-handed. Initial treatment should therefore be conservative, with intensive rehabilitation and retraining. It is recommended that amputation should not be considered until a year after injury and only if the flail limb causes repulsion, prevents sporting activities or if the patient has difficulty in converting to the non-dominant limb. In no instance should smputation be done for relief of pain


The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 799 - 799
1 Nov 1962

At the time of publication sixty-three additional patients have been fitted with the patellar tendon bearing prosthesis. Twenty of these were new amputees, and forty-three were old amputees who had previously worn a conventional limb. Of this group, nine were considered failures. The contra-indications for fitting now include: 1) coincident knee derangement such as cruciate or collateral ligament laxity (the trauma that causes the amputation often produces knee injuries as well; in this event the side irons of the conventional prosthesis help to support the knee); 2) scars in the popliteal fossa, such as those produced by exploration of the popliteal vessels; 3) marked variation in stump size such as in rapidly growing children or obese people; and 4) labourers obliged to work on rough ground, which places additional strain on the knee


Bone & Joint Open
Vol. 4, Issue 11 | Pages 817 - 824
1 Nov 2023
Filis P Varvarousis D Ntritsos G Dimopoulos D Filis N Giannakeas N Korompilias A Ploumis A

Aims

The standard of surgical treatment for lower limb neoplasms had been characterized by highly interventional techniques, leading to severe kinetic impairment of the patients and incidences of phantom pain. Rotationplasty had arisen as a potent limb salvage treatment option for young cancer patients with lower limb bone tumours, but its impact on the gait through comparative studies still remains unclear several years after the introduction of the procedure. The aim of this study is to assess the effect of rotationplasty on gait parameters measured by gait analysis compared to healthy individuals.

Methods

The MEDLINE, Scopus, and Cochrane databases were systematically searched without time restriction until 10 January 2022 for eligible studies. Gait parameters measured by gait analysis were the outcomes of interest.


Aims. The Intraosseous Transcutaneous Amputation Prosthesis (ITAP) may improve quality of life for amputees by avoiding soft-tissue complications associated with socket prostheses and by improving sensory feedback and function. It relies on the formation of a seal between the soft tissues and the implant and currently has a flange with drilled holes to promote dermal attachment. Despite this, infection remains a significant risk. This study explored alternative strategies to enhance soft-tissue integration. Materials and Methods. The effect of ITAP pins with a fully porous titanium alloy flange with interconnected pores on soft-tissue integration was investigated. The flanges were coated with fibronectin-functionalised hydroxyapatite and silver coatings, which have been shown to have an antibacterial effect, while also promoting viable fibroblast growth in vitro. The ITAP pins were implanted along the length of ovine tibias, and histological assessment was undertaken four weeks post-operatively. Results. The porous titanium alloy flange reduced epithelial downgrowth and increased soft-tissue integration compared with the current drilled flange. The addition of coatings did not enhance these effects. Conclusion. These results indicate that a fully porous titanium alloy flange has the potential to increase the soft-tissue seal around ITAP and reduce susceptibility to infection compared with the current design. Cite this article: Bone Joint J 2017;99-B:393–400


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 21 - 28
1 Jan 2023
Ndlovu S Naqshband M Masunda S Ndlovu K Chettiar K Anugraha A

Aims

Clinical management of open fractures is challenging and frequently requires complex reconstruction procedures. The Gustilo-Anderson classification lacks uniform interpretation, has poor interobserver reliability, and fails to account for injuries to musculotendinous units and bone. The Ganga Hospital Open Injury Severity Score (GHOISS) was designed to address these concerns. The major aim of this review was to ascertain the evidence available on accuracy of the GHOISS in predicting successful limb salvage in patients with mangled limbs.

Methods

We searched electronic data bases including PubMed, CENTRAL, EMBASE, CINAHL, Scopus, and Web of Science to identify studies that employed the GHOISS risk tool in managing complex limb injuries published from April 2006, when the score was introduced, until April 2021. Primary outcome was the measured sensitivity and specificity of the GHOISS risk tool for predicting amputation at a specified threshold score. Secondary outcomes included length of stay, need for plastic surgery, deep infection rate, time to fracture union, and functional outcome measures. Diagnostic test accuracy meta-analysis was performed using a random effects bivariate binomial model.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 539 - 550
21 Jul 2023
Banducci E Al Muderis M Lu W Bested SR

Aims

Safety concerns surrounding osseointegration are a significant barrier to replacing socket prosthesis as the standard of care following limb amputation. While implanted osseointegrated prostheses traditionally occur in two stages, a one-stage approach has emerged. Currently, there is no existing comparison of the outcomes of these different approaches. To address safety concerns, this study sought to determine whether a one-stage osseointegration procedure is associated with fewer adverse events than the two-staged approach.

Methods

A comprehensive electronic search and quantitative data analysis from eligible studies were performed. Inclusion criteria were adults with a limb amputation managed with a one- or two-stage osseointegration procedure with follow-up reporting of complications.


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 669 - 679
1 Jul 2024
Schnetz M Maluki R Ewald L Klug A Hoffmann R Gramlich Y

Aims

In cases of severe periprosthetic joint infection (PJI) of the knee, salvage procedures such as knee arthrodesis (KA) or above-knee amputation (AKA) must be considered. As both treatments result in limitations in quality of life (QoL), we aimed to compare outcomes and factors influencing complication rates, mortality, and mobility.

Methods

Patients with PJI of the knee and subsequent KA or AKA between June 2011 and May 2021 were included. Demographic data, comorbidities, and patient history were analyzed. Functional outcomes and QoL were prospectively assessed in both groups with additional treatment-specific scores after AKA. Outcomes, complications, and mortality were evaluated.


Bone & Joint Research
Vol. 11, Issue 6 | Pages 409 - 412
22 Jun 2022
Tsang SJ Ferreira N Simpson AHRW


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 177 - 182
1 Jan 2022
Hartley LJ AlAqeel M Kurisunkal VJ Evans S

Aims

Current literature suggests that survival outcomes and local recurrence rates of primary soft-tissue sarcoma diagnosed in the very elderly age range, (over 90 years), are comparable with those in patients diagnosed under the age of 75 years. Our aim is to quantify these outcomes with a view to rationalizing management and follow-up for very elderly patients.

Methods

Retrospective access to our prospectively maintained oncology database yielded a cohort of 48 patients across 23 years with a median follow-up of 12 months (0 to 78) and mean age at diagnosis of 92 years (90 to 99). Overall, 42 of 48 of 48 patients (87.5%) were managed surgically with either limb salvage or amputation.


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 3 | Pages 421 - 424
1 Aug 1965
Popov B

1. A bio-electrically controlled limb for forearm amputees is described. 2. The technique of its use and its advantages are listed


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 168 - 176
1 Jan 2022
Spence S Doonan J Farhan-Alanie OM Chan CD Tong D Cho HS Sahu MA Traub F Gupta S

Aims

The modified Glasgow Prognostic Score (mGPS) uses preoperative CRP and albumin to calculate a score from 0 to 2 (2 being associated with poor outcomes). mGPS is validated in multiple carcinomas. To date, its use in soft-tissue sarcoma (STS) is limited, with only small cohorts reporting that increased mGPS scores correlates with decreased survival in STS patients.

Methods

This retrospective multicentre cohort study identified 493 STS patients using clinical databases from six collaborating hospitals in three countries. Centres performed a retrospective data collection for patient demographics, preoperative blood results (CRP and albumin levels and neutrophil, leucocyte, and platelets counts), and oncological outcomes (disease-free survival, local, or metastatic recurrence) with a minimum of two years' follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 169 - 170
1 Jan 1991
Sooriakumaran S Landham T

The Klippel-Trenaunay Syndrome is a triad of congenital anomalies characterized by a vascular naevus, varicose veins and hypertrophy of soft tissue and bone. A number of patients affected with this rare syndrome need amputation. In this paper the systemic problems, stump complications and prosthetic difficulties of four amputees with Klippel-Trenaunay syndrome are outlined. The period of follow-up ranged from 10 to 24 years after amputation


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 2 | Pages 217 - 219
1 May 1975
Fulford GE Cairns TP

Quadrilateral shaped brims made of high-density polyethylene have been used with satisfactory results on more than 120 patients who needed ischial-bearing long leg calipers. At first the fitting technique was the same as that used for thigh amputees. Subsequently it has been possible to fit most patients from a range of pre-formed brims. The properties of high-density polyethylene allow the caliper side irons to be riveted directly to the brim which, with the use of ready-made brims, allows a patient to be fitted rapidly with a comfortable and effective caliper


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 385 - 388
1 May 1991
Garst R

Little has been published about the Krukenberg operation, which has been regarded as primarily indicated for the blind patient with bilateral hand amputations. Of the 35 Krukenberg cineplasty operations I have performed in the last 36 years, only two have been on blind patients. The operation provides forearm amputees with pincers which allow them to perform tasks without a prosthesis, but does not preclude the use of any type of aid. The author's operative procedure is described and the results illustrate its practical application for most patients