The purpose of this study was to compare the clinical, radiological, and patient-reported outcome measures (PROMs) in the first 100 consecutive patients undergoing total hip arthroplasty (THA) via a direct superior approach (DSA) with a matched group of patients undergoing THA by the same surgeon, using a posterolateral approach (PLA). This was a retrospective single surgeon study comparing the first 100 consecutive DSA THA patients with a matched group of patients using a standard PLA. Case notes were examined for patient demographics, length of hospital stay, operating time, intra- and postoperative complications, pain score, satisfaction score, and Oxford Hip Score (OHS). Leg length discrepancy and component positioning were measured from postoperative plain radiographs.Aims
Methods
Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP. We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement.Aims
Methods
Malreduction of the syndesmosis has been reported in up to 52% of patients after fixation of ankle fractures. Multiple radiological parameters are used to define malreduction; there has been limited investigation of the accuracy of these measurements in differentiating malreduction from inherent anatomical asymmetry. The purpose of this study was to identify the prevalence of positive malreduction standards within the syndesmosis of native, uninjured ankles. Three observers reviewed 213 bilateral lower limb CT scans of uninjured ankles. Multiple measurements were recorded on the axial CT 1 cm above the plafond: anterior syndesmotic distance; posterior syndesmotic distance; central syndesmotic distance; fibular rotation; and sagittal fibular translation. Previously studied malreduction standards were evaluated on bilateral CT, including differences in: anterior, central and posterior syndesmotic distance; mean syndesmotic distance; fibular rotation; sagittal translational distance; and syndesmotic area. Unilateral CT was used to compare the anterior to posterior syndesmotic distances.Aims
Methods
Existing literature indicates that inferiorly inclined glenoid baseplates following reverse total shoulder arthroplasty (RSA) produce better outcomes compared to superiorly inclined baseplates. We aim to compare clinical outcomes for RSAs with superiorly and neutrally/inferiorly inclined lateralized glenospheres. We retrospectively reviewed 154 consecutive patients undergoing RSA between July 2015 and July 2017 by one single-fellowship trained surgeon (AJ). Two raters (KAM and MVS) independently measured glenoid inclination in preoperative and minimum two year follow-up radiographs (anteroposterior/Grashey) using the RSA angle. Inclination was then compared to patient-reported outcomes, range of motion (ROM), and independently assessed degree of scapular notching and staging of heterotopic ossification at two year follow-up.Aims
Methods
Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An in vitro wear simulator study showed that E1 reduced polyethylene wear. However there is no published information regarding in vivo wear. Previous reports suggest that newly introduced materials which reduce in vitro polyethylene wear do not necessarily reduce in vivo polyethylene wear. To assist in the evaluation of the newly introduced material before widespread use, we established an in vivo polyethylene wear particle analysis for TKA. The aim of this study was to compare in vivo polyethylene wear particle generation between E1 and conventional polyethylene (ArCom) in TKA. A total of 34 knees undergoing TKA (17 each with ArCom or E1) were investigated. Except for the polyethylene insert material, the prostheses used for both groups were identical. Synovial fluid was obtained at a mean of 3.4 years (SD 1.3) postoperatively. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined by scanning electron microscopy.Aims
Methods
Patient-reported outcome measures (PROMs) are being used increasingly in total knee arthroplasty (TKA). We conducted a systematic review aimed at identifying psychometrically sound PROMs by appraising their measurement properties. Studies concerning the development and/or evaluation of the measurement properties of PROMs used in a TKA population were systematically retrieved via PubMed, Web of Science, Embase, and Scopus. Ratings for methodological quality and measurement properties were conducted according to updated COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) methodology. Of the 155 articles on 34 instruments included, nine PROMs met the minimum requirements for psychometric validation and can be recommended to use as measures of TKA outcome: Oxford Knee Score (OKS); OKS–Activity and Participation Questionnaire (OKS-APQ); 12-item short form Knee Injury and Osteoarthritis Outcome (KOOS-12); KOOS Physical function Short form (KOOS-PS); Western Ontario and McMaster Universities Arthritis Index-Total Knee Replacement function short form (WOMAC-TKR); Lower Extremity Functional Scale (LEFS); Forgotten Joint Score (FJS); Patient’s Knee Implant Performance (PKIP); and University of California Los Angeles (UCLA) activity score. The pain and function subscales in WOMAC, as well as the pain, function, and quality of life subscales in KOOS, were validated psychometrically as standalone subscales instead of as whole instruments. However, none of the included PROMs have been validated for all measurement properties. Thus, further studies are still warranted to evaluate those PROMs. Use of the other 25 scales and subscales should be tempered until further studies validate their measurement properties. Cite this article:
The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm3 cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate.Aims
Methods
The aim of this study was to assess the effectiveness of perioperative essential amino acid (EAA) supplementation to prevent rectus femoris muscle atrophy and facilitate early recovery of function after total knee arthroplasty (TKA). The study involved 60 patients who underwent unilateral TKA for primary knee osteo-arthritis (OA). This was a double-blind, placebo-controlled, randomized control trial with patients randomly allocated to two groups, 30 patients each: the essential amino acid supplementation (9 g daily) and placebo (lactose powder, 9 g daily) groups. Supplementation and placebo were provided from one week before to two weeks after surgery. The area of the rectus femoris muscle were measured by ultrasound imaging one month before surgery and one, two, three, and four weeks postoperatively. The serum albumin level, a visual analogue knee pain score, and mobility were also measured at each time point. The time to recovery of activities of daily living (ADLs) was recorded. Postoperative nutrition and physiotherapy were identical in both groups.Aims
Methods
It remains controversial whether patellofemoral joint pathology is a contraindication to lateral unicompartmental knee arthroplasty (UKA). This study aimed to evaluate the effect of preoperative radiological degenerative changes and alignment on patient-reported outcome scores (PROMs) after lateral UKA. Secondarily, the influence of lateral UKA on the alignment of the patellofemoral joint was studied. A consecutive series of patients who underwent robotic arm-assisted fixed-bearing lateral UKA with at least two-year follow-up were retrospectively reviewed. Radiological evaluation was conducted to obtain a Kellgren Lawrence (KL) grade, an Altman score, and alignment measurements for each knee. Postoperative PROMs were assessed using the Kujala (Anterior Knee Pain Scale) score, Knee Injury and Osteoarthritis Outcome Score Joint Replacement (KOOS JR), and satisfaction levels.Aims
Methods
The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and radiological outcomes following THA using fully hydroxyapatite (HA)-coated femoral components. We retrospectively reviewed records of 183 primary uncemented THAs. Femoral morphology, including Dorr classification, canal bone ratio (CBR), canal flare index (CFI), and canal-calcar ratio (CCR), were calculated on preoperative radiographs. The canal fill ratio (CFR) was calculated at different levels relative to the lesser trochanter (LT) using immediate postoperative radiographs: P1, 2 cm above LT; P2, at LT; P3, 2 cm below LT; and D1, 7 cm below LT. At two years, radiological femoral component osseointegration was evaluated using the Engh score, and hip function using the Postel Merle d’Aubigné (PMA) and Oxford Hip Score (OHS).Aims
Methods
The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension gaps, mediolateral soft-tissue laxity, fixed flexion deformity (FFD), and limb alignment during posterior-stabilized (PS) total knee arthroplasty (TKA). This prospective study included 110 patients with symptomatic osteoarthritis of the knee undergoing primary robot-assisted PS TKA. All operations were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess gaps before and after PCL resection in extension and 90° knee flexion. Measurements were made after excision of the anterior cruciate ligament and prior to bone resection. There were 54 men (49.1%) and 56 women (50.9%) with a mean age of 68 years (Aims
Patients and Methods
The aim of this study was to evaluate the outcomes of a salvage procedure using a 95° angled blade plate for failed osteosynthesis of atypical subtrochanteric femoral fractures associated with the long-term use of bisphosphonates. These were compared with those for failed osteosynthesis of subtrochanteric fractures not associated with bisphosphonate treatment. Between October 2008 and July 2016, 14 patients with failed osteosynthesis of an atypical subtrochanteric femoral fracture were treated with a blade plate (atypical group). Their mean age was 67.8 years (60 to 74); all were female. During the same period, 21 patients with failed osteosynthesis of a typical subtrochanteric fracture underwent restabilization using a blade plate (typical group). Outcome variables included the time of union, postoperative complications, Harris Hip Score, and Sanders functional rating scale.Aims
Patients and Methods
The objective of this study was to assess the association between whole body sagittal balance and risk of falls in elderly patients who have sought treatment for back pain. Balanced spinal sagittal alignment is known to be important for the prevention of falls. However, spinal sagittal imbalance can be markedly compensated by the lower extremities, and whole body sagittal balance including the lower extremities should be assessed to evaluate actual imbalances related to falls. Patients over 70 years old who visited an outpatient clinic for back pain treatment and underwent a standing whole-body radiograph were enrolled. Falls were prospectively assessed for 12 months using a monthly fall diary, and patients were divided into fallers and non-fallers according to the history of falls. Radiological parameters from whole-body radiographs and clinical data were compared between the two groups.Objectives
Methods
In this study we used subject-specific finite
element analysis to investigate the mechanical effects of rotational acetabular
osteotomy (RAO) on the hip joint and analysed the correlation between
various radiological measurements and mechanical stress in the hip
joint. We evaluated 13 hips in 12 patients (two men and ten women, mean
age at surgery 32.0 years; 19 to 46) with developmental dysplasia
of the hip (DDH) who were treated by RAO. Subject-specific finite element models were constructed from
CT data. The centre–edge (CE) angle, acetabular head index (AHI),
acetabular angle and acetabular roof angle (ARA) were measured on
anteroposterior pelvic radiographs taken before and after RAO. The
relationship between equivalent stress in the hip joint and radiological measurements
was analysed. The equivalent stress in the acetabulum decreased from 4.1 MPa
(2.7 to 6.5) pre-operatively to 2.8 MPa (1.8 to 3.6) post-operatively
(p <
0.01). There was a moderate correlation between equivalent
stress in the acetabulum and the radiological measurements: CE angle
(R = –0.645, p <
0.01); AHI (R = –0.603, p <
0.01); acetabular
angle (R = 0.484, p = 0.02); and ARA (R = 0.572, p <
0.01). The equivalent stress in the acetabulum of patients with DDH
decreased after RAO. Correction of the CE angle, AHI and ARA was
considered to be important in reducing the mechanical stress in
the hip joint. Cite this article:
Version of the femoral stem is an important factor
influencing the risk of dislocation after total hip replacement (THR)
as well as the position of the acetabular component. However, there
is no radiological method of measuring stem anteversion described
in the literature. We propose a radiological method to measure stem
version and have assessed its reliability and validity. In 36 patients
who underwent THR, a hip radiograph and CT scan were taken to measure
stem anteversion. The radiograph was a modified Budin view. This
is taken as a posteroanterior radiograph in the sitting position
with 90° hip flexion and 90° knee flexion and 30° hip abduction.
The angle between the stem-neck axis and the posterior intercondylar
line was measured by three independent examiners. The intra- and
interobserver reliabilities of each measurement were examined. The
radiological measurements were compared with the CT measurements
to evaluate their validity. The mean radiological measurement was
13.36° ( Cite this article:
A small proportion of children with Gartland
type III supracondylar humeral fracture (SCHF) experience troubling limited
or delayed recovery after operative treatment. We hypothesised that
the fracture level relative to the isthmus of the humerus would
affect the outcome. We retrospectively reviewed 230 children who underwent closed
reduction and percutaneous pinning (CRPP) for their Gartland type
III SCHFs between March 2003 and December 2012. There were 144 boys
and 86 girls, with the mean age of six years (1.1 to 15.2). The
clinico-radiological characteristics and surgical outcomes (recovery
of the elbow range of movement, post-operative angulation, and the
final Flynn grade) were recorded. Multivariate analysis was employed
to identify prognostic factors that influenced outcome, including
fracture level. Multivariate analysis revealed that a fracture below
the humeral isthmus was significantly associated with poor prognosis
in terms of the range of elbow movement (p <
0.001), angulation
(p = 0.001) and Flynn grade (p = 0.003). Age over ten years was also
a poor prognostic factor for recovery of the range of elbow movement (p
= 0.027). This is the first study demonstrating a subclassification system
of Gartland III fractures with prognostic significance. This will
guide surgeons in peri-operative planning and counselling as well
as directing future research aimed at improving outcomes. Cite this article:
We studied the intra- and interobserver reliability of measurements of the position of the components after total knee replacement (TKR) using a combination of radiographs and axial two-dimensional (2D) and three-dimensional (3D) reconstructed CT images to identify which method is best for this purpose. A total of 30 knees after primary TKR were assessed by two independent observers (an orthopaedic surgeon and a radiologist) using radiographs and CT scans. Plain radiographs were highly reliable at measuring the tibial slope, but showed wide variability for all other measurements; 2D-CT also showed wide variability. 3D-CT was highly reliable, even when measuring rotation of the femoral components, and significantly better than 2D-CT. Interobserver variability in the measurements on radiographs were good (intraclass correlation coefficient (ICC) 0.65 to 0.82), but rotational measurements on 2D-CT were poor (ICC 0.29). On 3D-CT they were near perfect (ICC 0.89 to 0.99), and significantly more reliable than 2D-CT (p <
0.001). 3D-reconstructed images are sufficiently reliable to enable reporting of the position and orientation of the components. Rotational measurements in particular should be performed on 3D-reconstructed CT images. When faced with a poorly functioning TKR with concerns over component positioning, we recommend 3D-CT as the investigation of choice.