Advertisement for orthosearch.org.uk
Results 21 - 40 of 520
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 44-B, Issue 4 | Pages 937 - 943
1 Nov 1962
Klenerman L

The history of surgery is to a large extent written around the record of its technical advances. A pneumatic tourniquet is a humble instrument, when compared with many of the more complicated mechanical devices in the modern operation theatre. Nevertheless, it has played a significant role in making possible the precise operations of present-day orthopaedics. Simple tool though the tourniquet may be, its application carries many potential dangers, and it should only he entrusted to skilled hands


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 2 | Pages 178 - 183
1 May 1979
Patterson S Klenerman L

Experiments have been carried out on rhesus monkeys to determine the effect of the application of a pneumatic tourniquet on the ultrastructure of the muscles of the lower limb. Tourniquets were applied for periods lasting between one and five hours. The changes in the muscle lying immediately under the cuff of the tourniquet were more marked than those observed in muscle distal to the cuff. Three hours appears to be close to the limit of the time that a muscle can resist the sustained compression of a tourniquet


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 3 | Pages 385 - 388
1 Aug 1980
Klenerman L Biswas M Hulands G Rhodes A

The effect of the application of a tourniquet to a limb and the release of the accumulated metabolites have been investigated with reference to the acid-base level in the blood from the limb and in the right atrium. Investigations have been carried out experimentally in rhesus monkeys and observations have been made on patients undergoing reconstructive operations on the knee. The acidotic blood from the ischaemic limb produces little systemic effect. The limb recovers in approximately 40 minutes after a tourniquet has been in place for four hours. Three hours is recommended as a reasonable upper limit for the safe application of a pneumatic tourniquet


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 4 | Pages 625 - 628
1 Aug 1986
Newman R Muirhead A

An unusually wide pneumatic tourniquet has recently become available; we provide a simple formula for its use with a low but effective inflation pressure. A prospective, randomised and controlled trial in 600 lower limb and 150 upper limb operations is reported. The wide tourniquet (12.5 cm) was as effective at low pressure as was a conventional tourniquet (9 cm) inflated to significantly higher pressures. Fewer patients suffered from painful paraesthesiae after operation using the broad, low-pressure tourniquet


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 2 | Pages 250 - 253
1 Mar 1995
Abdel-Salam A Eyres K

The effects of using a tourniquet during total knee arthroplasty were studied in 80 patients randomly allocated to two groups, either with or without a tourniquet. The groups were similar in mean age, gender, preoperative knee score and radiographic grading and the patients were all operated on by the same surgeon using one type of prosthesis. There was no significant difference between the two groups in operating time or total blood loss but postoperative pain was less in the patients in whom a tourniquet had not been used. They achieved straight-leg raising and knee flexion earlier and had fewer superficial wound infections and deep-vein thromboses. Total knee arthroplasty can be safely performed without the use of the tourniquet with the benefit that several adverse effects associated with its use can be avoided


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 244 - 245
1 Feb 2007
Haene RA Loeffler M

An 11-week-old infant presented with swelling and discoloration of the left second toe because of hair thread tourniquet syndrome. This was treated by urgent surgical release of the constricting band, with a successful outcome. The authors stress the importance of recognising this rare condition and of prompt, complete, surgical release


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 86 - 87
1 Jan 1991
Salam A Eyres K Cleary J el-Sayed H

Sixty closed fractures of the tibia were treated by open reduction and internal fixation with plates and screws. Half the operations were performed with a thigh tourniquet and half without. In the tourniquet group, there were six cases with erythema and induration of the wound; in the other group there were no such complications. Despite negative bacterial cultures, superficial infection of the inflamed wounds was suspected. It is suggested that a tourniquet may predispose tissues to infection, and its use is not recommended during operations for internal fixation of the tibia


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 434 - 440
1 May 1984
Newman R

A model of tourniquet ischaemia was developed in the hind limb of the rat, and the metabolic changes that occurred in the calf muscles were monitored by the non-invasive technique of phosphorus-31 nuclear magnetic resonance spectroscopy. During ischaemia the intramyocellular pH became acidic as the level of phosphocreatine declined and that of inorganic phosphate rose. Phosphocreatine was no longer detectable after approximately 2 hours and ATP was depleted after approximately 3.5 hours. Metabolic recovery was rapid (1 hour) if ATP was present when the tourniquet was released but was prolonged (3 or more hours) if ATP was depleted. Hourly release of the tourniquet for 10 minutes ensured the maintenance of ATP and rapid metabolic recovery. Release for intervals of only 5 minutes did not have the same protective effect and in fact worsened tissue pH during the period of tourniquet ischaemia. Heparin and corticosteroids were without effect during and after periods of tourniquet ischaemia


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 265 - 268
1 Mar 1997
Barwell J Anderson G Hassan A Rawlings I

We studied the effects of the timing of tourniquet release in 88 patients randomly allocated for release after wound closure and bandaging (group A), or before the quadriceps layer had been closed allowing control of bleeding before suture (group B). The groups were similar in mean age, weight, gender, preoperative knee score, radiographic grading, and prosthesis implanted. Patients in group B had less postoperative pain, achieved earlier straight-leg raising, and had fewer wound complications. Five patients in group A had to return to theatre, three for manipulation under anaesthesia, one for secondary closure of wound dehiscence, and one for drainage of a haematoma. The last patient later developed a deep infection, which was treated by a two-stage revision. There were no significant differences between the two groups in operating time, or the decrease in haemoglobin concentration at 48 hours postoperatively. Some of the adverse effects of the use of a tourniquet for knee surgery can be significantly reduced by early tourniquet release, with haemostasis before the quadriceps mechanism and the wound are closed


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 32 - 35
1 Jan 1993
Richardson J Roberts A Robertson J John P Sweeney G

Cephamandole levels in serum and drain fluid were measured in 32 knee replacement operations to determine the benefit of an intravenous dose of antibiotic at the time of tourniquet deflation. Concentrations of cephamandole in drain fluid were directly proportional to the serum concentration at the time of tourniquet release. A 'tourniquet-release' dose of antibiotic increased drain fluid concentration threefold


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 805 - 806
1 May 2021
Magan AA Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 322 - 324
1 Mar 1988
Bannister G Auchincloss J Johnson D Newman J

Antibiotic levels in bone and fat were measured in patients undergoing knee replacement to determine the time that should elapse between intravenous injection and tourniquet inflation. The tissue levels increased progressively with time, and there was wide variation in absorption rate between patients and between the two cephalosporins assessed. Five minutes should probably be left between systemic injection and inflation of the tourniquet, though two minutes may be long enough for drugs which are rapidly absorbed


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 828 - 829
1 May 2021
Ahmed I Chawla A Underwood M Price AJ Metcalfe A Hutchinson CE Warwick J Seers K Parsons H Wall PDH


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 1 | Pages 97 - 99
1 Jan 1987
Luk K Pun W

We report a case in which compartment syndrome and tourniquet paralysis occurred simultaneously. This is a previously unreported combination which presents a diagnostic problem. We recommend that electrophysiological studies and continuous monitoring of compartment pressures should be used to minimise morbidity in high-risk cases


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 932 - 933
1 Sep 1999
AGU O BAHER D HAMILTON G


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 932 - 932
1 Sep 1999
EYRES KS SHARPE I ABDEL-SALAM A


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 934 - 934
1 Sep 1999
ÖMEROĞLU H SEBER S


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 164 - 164
1 Jan 1992
Edwards A


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 869 - 869
1 Sep 1991
McMaster M


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 4 | Pages 374 - 375
1 Aug 1983
Klenerman L