Advertisement for orthosearch.org.uk
Results 21 - 40 of 731
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1170 - 1173
1 Nov 2000
Hübner U Schlicht W Outzen S Barthel M Halsband H

We compared the results of primary ultrasonographic examination of 163 children with 224 suspected fractures with the subsequent radiological findings. The aim was to assess the value of ultrasound in the diagnosis of fractures in children. We found a good correlation for fractures of the long bones of the upper and lower limbs. Ultrasound was most reliable for the detection of simple femoral and humeral diaphyseal fractures and fractures of the forearm. It was less dependable for compound injuries and fractures adjacent to joints, lesions of the small bones of the hand and foot, non-displaced epiphyseal fractures (Salter-Harris type 1) or those with a fracture line of less than 1mm. We were able to distinguish several types of fracture in which the use of ultrasound alone gave reliable information and further radiography was unnecessary. We discuss the advantages and disadvantages of skeletal ultrasonographic studies in children


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 984 - 988
1 Jul 2014
Pullinger M Southorn T Easton V Hutchinson R Smith RP Sanghrajka AP

Congenital Talipes Equinovarus (CTEV) is one of the most common congenital limb deformities. We reviewed the records of infants who had received treatment for structural CTEV between 1 January 2007 and 30 November 2012. This was cross-referenced with the prenatal scans of mothers over a corresponding period of time. We investigated the sensitivity, specificity, and positive and negative predictive values of the fetal anomaly scan for the detection of CTEV and explored whether the publication of Fetal Anomaly Screening Programme guidelines in 2010 affected the rate of detection. During the study period there were 95 532 prenatal scans and 34 373 live births at our hospital. A total of 37 fetuses with findings suggestive of CTEV were included in the study, of whom 30 were found to have structural CTEV at birth. The sensitivity of screening for CTEV was 71.4% and the positive predictive value was 81.1%. The negative predictive value and specificity were more than 99.5%. There was no significant difference between the rates of detection before and after publication of the guidelines (p = 0.5). We conclude that a prenatal fetal anomaly ultrasound screening diagnosis of CTEV has a good positive predictive value enabling prenatal counselling. The change in screening guidance has not affected the proportion of missed cases. This information will aid counselling parents about the effectiveness and accuracy of prenatal ultrasound in diagnosing CTEV. Cite this article: Bone Joint J 2014;96-B:984–8


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 494 - 502
1 Apr 2017
Simpson AHRW Keenan G Nayagam S Atkins RM Marsh D Clement ND

Aims. The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame. Results. There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042). Conclusion. LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. . Cite this article: Bone Joint J 2017;99-B:494–502


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1077 - 1082
1 Sep 2000
Shimazaki A Inui K Azuma Y Nishimura N Yamano Y

We investigated the effects of low-intensity pulsed ultrasound on distraction osteogenesis in a rabbit model. Callotasis of the right tibia was performed in 70 male Japanese white rabbits using mini-external fixators. In the first part of the study in 64 animals using normal distraction (waiting period seven days; distraction rate 0.5 mm/12 hours; distraction period ten days), we evaluated the distraction site by radiography, measurement of the bone mineral density (BMD), mechanical testing, and histology. In the second part in six rabbits using fast distraction (waiting period 0 days; distraction rate 1.5 mm/12 hours; distraction period seven days) the site was evaluated radiologically. Half of the animals (35) had received ultrasound to their right leg (30mW/cm. 2. ) for 20 minutes daily after ceasing distraction (ultrasound group), while rigid fixation only was maintained in the other half (control group). With normal distraction, the hard callus area, as shown by radiography, the BMD, and the findings on mechanical testing, were significantly greater in those receiving ultrasound than in the control group. Histological analysis showed no tissue damage attributable to exposure to ultrasound. With fast distraction, immature bone regeneration was observed radiologically in the control group, while bone maturation was achieved in the ultrasound group. We conclude that ultrasound can accelerate bone maturation in distraction osteogenesis in rabbits, even in states of poor callotasis


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1126 - 1130
1 Aug 2011
Thaler M Biedermann R Lair J Krismer M Landauer F

Between 1978 and 1997 all newborns in the Austrian province of Tyrol were reviewed regarding hip dysplasia and related surgery. This involved a mean of 8257 births per year (7766 to 8858). Two observation periods were determined: 1978 to 1982 (clinical examination alone) and 1993 to 1997 (clinical examination and universal ultrasound screening). A retrospective analysis compared the number and cost of interventions due to hip dysplasia in three patient age groups: A, 0 to < 1.5 years; B, ≥ 1.5 to < 15 years; and C, ≥ 15 to < 35 years. In group A, there was a decrease in hip reductions from a mean of 25.2 (. sd. 2.8) to 7.0 (. sd. 1.4) cases per year. In group B, operative procedures decreased from a mean of 17.8 (. sd. 3.5) to 2.6 (. sd. 1.3) per year. There was a 75.9% decrease in the total number of interventions for groups A and B. An increase of €57 000 in the overall cost per year for the second period (1993 to 1997) was seen, mainly due to the screening programme. However, there was a marked reduction in costs of all surgical and non-surgical treatments for dysplastic hips from €410 000 (1978 to 1982) to €117 000 (1993 to 1997). We believe the small proportional increase in costs of the universal ultrasound screening programme is justifiable as it was associated with a reduction in the number of non-surgical and surgical interventions. We therefore recommend universal hip ultrasound screening for neonates


Bone & Joint Research
Vol. 5, Issue 11 | Pages 538 - 543
1 Nov 2016
Weeks BK Hirsch R Nogueira RC Beck BR

Objectives. The aim of the current study was to assess whether calcaneal broadband ultrasound attenuation (BUA) can predict whole body and regional dual-energy x-ray absorptiometry (DXA)-derived bone mass in healthy, Australian children and adolescents at different stages of maturity. Methods. A total of 389 boys and girls across a wide age range (four to 18 years) volunteered to participate. The estimated age of peak height velocity (APHV) was used to classify children into pre-, peri-, and post-APHV groups. BUA was measured at the non-dominant heel with quantitative ultrasonometry (QUS) (Lunar Achilles Insight, GE), while bone mineral density (BMD) and bone mineral content (BMC) were examined at the femoral neck, lumbar spine and whole body (DXA, XR-800, Norland). Associations between BUA and DXA-derived measures were examined with Pearson correlations and linear regression. Participants were additionally ranked in quartiles for QUS and DXA measures in order to determine agreement in rankings. Results. For the whole sample, BUA predicted 29% of the study population variance in whole body BMC and BMD, 23% to 24% of the study population variance in lumbar spine BMC and BMD, and 21% to 24% of the variance in femoral neck BMC and BMD (p < 0.001). BUA predictions were strongest for the most mature participants (pre-APHV R. 2. = 0.03 to 0.19; peri-APHV R. 2. = 0.05 to 0.17; post-APHV R. 2. = 0.18 to 0.28) and marginally stronger for girls (R. 2. = 0.25-0.32, p < 0.001) than for boys (R. 2. = 0.21-0.27, p < 0.001). Agreement in quartile rankings between QUS and DXA measures of bone mass was generally poor (27.3% to 38.2%). Conclusion. Calcaneal BUA has a weak to moderate relationship with DXA measurements of bone mass in children, and has a tendency to misclassify children on the basis of quartile rankings. Cite this article: B. K. Weeks, R. Hirsch, R. C. Nogueira, B. R. Beck. Is calcaneal broadband ultrasound attenuation a valid index of dual-energy x-ray absorptiometry-derived bone mass in children? Bone Joint Res 2016;5:538–543. DOI: 10.1302/2046-3758.511.BJR-2016-0116.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 636 - 640
1 Jul 1996
Terjesen T Holen KJ Tegnander A

We have followed the natural progress of newborn infants in whom ultrasound examination showed abnormalities in hips which appeared to be clinically normal. Over six years we saw 306 such children out of 9952 examined (31 per 1000 live births). The examination was repeated at two to three months and those who still showed an abnormality were followed up further. At four to five months a standard radiograph was obtained, and treatment began if this and another ultrasound scan were both abnormal. At this stage, 291 infants had normal hips. In the 15 infants with abnormal hips there was no pronounced deterioration, none developed a frank dislocation, and all became normal after treatment in an abduction splint. Newborn infants with abnormal and suspicious ultrasound findings who are normal on clinical examination do not need treatment from birth; most of these hips will settle spontaneously. Treatment can be postponed until the age of four to five months unless clinical instability develops or ultrasound shows dislocation. The criteria for treatment should be based on measurements by both ultrasound and radiography: both should show an abnormality before intervention is considered necessary


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 846 - 851
1 Sep 1999
Holen KJ Tegnander A Eik-Nes SH Terjesen T

We have evaluated the effect of the use of ultrasound in determining the initiation of treatment in neonatal instability of the hip. A total of 99 newborn infants (1.5% of all live births) with neonatal hip instability did not have treatment from birth, but were re-examined at eight to 15 days. In the 31 who had persisting clinical instability and ultrasound abnormality, treatment was then started with a Frejka pillow. The hips in the remaining 68 infants showed spontaneous clinical stabilisation and improvement of the ultrasound findings. Treatment was therefore withheld. There was a marked trend towards normal development in mildly unstable hips, whereas no hips with severe instability did so spontaneously. Further follow-up showed normal development in all the hips which had been treated, and in all except five of the 68 untreated infants. These five infants showed persistent hip dysplasia on both ultrasound and radiological examination at four to five months of age. Treatment with an abduction splint was then started and their hips developed normally. Ultrasound is very useful in deciding on treatment if the examiners have adequate experience with the method. Its use substantially reduces the rate of treatment. Spontaneous resolution occurred in more than half of the unstable hips. Since five of the untreated infants developed hip dysplasia a strict follow-up is essential to identify and treat these cases


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 406 - 412
1 May 1985
Clarke N Harcke H McHugh P Lee M Borns P MacEwen G

A technique of examining the infant hip joint with real-time ultrasound is described. Since the cartilaginous femoral head is clearly imaged by ultrasound, anatomical structures and their relationships can be accurately determined. Dislocated hips are easily detected and subluxations also can be visualized. We report our experience with 131 examinations in 104 patients, comprising 259 single hip studies. Of 83 patients who were previously untreated, there were 178 hip studies with three false-negative and four false-positive ultrasound results. No dislocations were missed. Twenty-seven patients who were already being treated were examined to assess hip location, comprising a total of 81 hip studies. In some cases the patients were examined while in an abduction device, cast, or Pavlik harness. In one case a dislocation was not detected. The method of examination using real-time ultrasound is considered to be reliable, accurate, and a useful adjunct to radiography. The advantages are that it is non-invasive, portable, and involves no exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 876 - 880
1 Aug 2000
Tillett RL Fisk NM Murphy K Hunt DM

Congenital talipes equinovarus is a common anomaly which can now be diagnosed prenatally on a routine ultrasound scan at 20 weeks of gestation. Prenatal counselling is increasingly offered to parents with affected fetuses, but it is difficult to counsel parents if there is a chance that the fetus may not have talipes. Our study correlates the prenatal ultrasound findings of 14 infants diagnosed as having unilateral or bilateral talipes during their routine 20-week ultrasound scan with their clinical findings at birth and the treatment received. No feet diagnosed as talipes on the ultrasound scan were completely normal at birth and therefore there were no true false-positive results. One foot graded as normal at 20 weeks was found to have a mild grade-1 talipes at birth, but did not require treatment other than simple stretches. A total of 32% of feet required no treatment and so could be considered functional false-positive results on the scan. Serial casting was required by 13% of feet and surgical treatment by 55%. The severity of the talipes is difficult to establish before birth. A number of patients are likely to need surgical treatment, but a proportion will have talipes so mildly that no treatment will be required. In counselling parents at 20 weeks, orthopaedic surgeons need to know whether or not there is a small chance that the ultrasound diagnosis could be wrong and also that the talipes may be so mild that the foot will not require treatment


Bone & Joint Research
Vol. 5, Issue 2 | Pages 26 - 32
1 Feb 2016
Wendling A Mar D Wischmeier N Anderson D McIff T

Objectives. The objective of this study was to determine if combining variations in mixing technique of antibiotic-impregnated polymethylmethacrylate (PMMA) cement with low frequency ultrasound (LFUS) improves antibiotic elution during the initial high phase (Phase I) and subsequent low phase (Phase II) while not diminishing mechanical strength. Methods. Three batches of vancomycin-loaded PMMA were prepared with different mixing techniques: a standard technique; a delayed technique; and a control without antibiotic. Daily elution samples were analysed using flow injection analysis (FIA). Beginning in Phase II, samples from each mix group were selected randomly to undergo either five, 15, 45, or 0 minutes of LFUS treatment. Elution amounts between LFUS treatments were analysed. Following Phase II, compression testing was done to quantify strength. A-priorit-tests and univariate ANOVAs were used to compare elution and mechanical test results between the two mix groups and the control group. Results. The delayed technique showed a significant increase in elution on day one compared with the standard mix technique (p < 0.001). The transition point from Phase I to Phase II occurred on day ten. LFUS treatments significantly increased elution amounts for all groups above control. Delayed technique resulted in significantly higher elution amounts for the five-minute- (p = 0.004) and 45-minute- (p < 0.001) duration groups compared with standard technique. Additionally, the correlations between LFUS duration and total elution amount for both mix techniques were significant (p = 0.03). Both antibiotic-impregnated groups exhibited a significant decrease in offset yield stress compared with the control group (p < 0.001), however, their lower 95% confidence intervals were all above the 70 MPa limit defined by International Standards Organization (ISO) 5833-2 reference standard for acrylic bone cement. Conclusion. The combination of a delayed mix technique with LFUS treatments provides a reasonable means for increasing both short- and long-term antibiotic elution without affecting mechanical strength. Cite this article: Dr. T. McIff. Combination of modified mixing technique and low frequency ultrasound to control the elution profile of vancomycin-loaded acrylic bone cement. Bone Joint Res 2016;5:26–32. doi: 10.1302/2046-3758.52.2000412


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 237 - 239
1 Mar 1989
Lausten G Jorgensen F Boesen J

Anteversion of the femoral neck of 30 unpaired dry bones was measured directly, by ultrasound, and by computerised tomography. The angles measured directly corresponded well with the angles found by CT scan, but there was poor correlation between these and the angles measured by ultrasound. At present ultrasound seems to be unsuitable for the measurement of anteversion of the femoral neck


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 79 - 82
1 Jan 1993
Howard C Einhorn M Dagan R Nyska M

We reviewed the ultrasound findings in 59 children suspected of having bone infection. Twenty-nine were eventually proved to have acute haematogenous osteomyelitis and 26 of these showed characteristic ultrasound findings. Such changes were rare in 30 patients with other clinically similar conditions. Ultrasound examination was also able to detect the presence of subperiosteal pus and thus indicate the need for surgical treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 2 | Pages 197 - 201
1 Mar 1990
Engesaeter L Wilson D Nag D Benson M

One-hundred newborn children at high risk of hip instability were prospectively assessed clinically and by ultrasound. The decision to treat was based only on the clinical examination. At the age of three months all the children were evaluated clinically and with an anteroposterior radiograph of the pelvis. None of the standard ultrasound measurements of acetabular depth and femoral head cover correlated with the outcome at three months. Dynamic assessment of stability was the only ultrasound technique that had a significant relation with outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 9 - 12
1 Jan 1989
Clarke N Clegg J Al-Chalabi A

Of 4,617 babies born in Coventry in 1986, a total of 448 (9.7%) had either clinical abnormality of the hip or at risk factors for CDH. All were examined by ultrasound, but only 17 required treatment (3.7 per 1,000); in five of these no clinical abnormality had been detected. An additional 81 babies had ultrasound abnormalities but did not require treatment, despite the fact that ultrasound at first showed major hip displacement in 17 of them. Three late cases of CDH have presented among the babies born in 1986, but not examined by ultrasound. This incidence of late CDH is unchanged compared with the previous nine years, although ultrasound had detected covert displacement in a number of hips


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 534 - 538
1 Jul 1994
Marks D Clegg J al-Chalabi A

We have undertaken routine ultrasound screening for neonatal hip instability in Coventry since June 1989. Of the 14,050 babies scanned during the first three years, 847 (6%) had ultrasound abnormalities. A grading system, based on the percentage of femoral head coverage, is presented. The proportion of abnormal hips decreased gradually so that by nine weeks, 90% had normal ultrasound appearances. Abnormality was more common in babies with a family history of CDH and in breech presentations. All babies with clinically abnormal hips had an abnormal first ultrasound examination. Five babies not diagnosed by clinical examination and with no risk factors had abnormal ultrasound appearances and were subsequently found to have clinically abnormal hips. Routine ultrasound screening has detected cases which would otherwise have presented late


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 549 - 553
1 Jul 1990
Bickerstaff D Neal L Booth A Brennan P Bell M

We made a prospective study of 111 children with acute hip pain to assess whether ultrasound can replace traditional radiography. An effusion was diagnosed in 71% by ultrasound but in only 15% by radiography. This effusion persisted for a mean of nine days; symptoms lasted for five days. Two patients found to have Perthes' disease had longer-lasting effusion and symptoms. Patients without an effusion had no obvious cause for their pain, so the pressure of an effusion from a transient synovitis does not account for all patients with irritable hips. Patients with an effusion persisting for over 24 days (the mean + 2 s.d. of our series) had more symptoms, a significantly larger effusion and greater limitation of movement. They may be more at risk for avascular necrosis. We found that radiographic examination influenced the immediate management of only two patients, those with Perthes' disease. We therefore propose a protocol of management for irritable hip, using ultrasonography at the first presentation of certain categories of patients. This would reduce the number of early radiographs by 75%


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 252 - 255
1 Mar 1989
Suzuki S Yamamuro T Shikata J Shimizu K Iida H

Ultrasound can be used to outline the spinous processes and the laminae, and thus to measure axial rotation. Using our own technique, we measured vertebral rotation in 47 patients with idiopathic scoliosis. There was a strong linear relationship between the Cobb angle and the rotation of the apical vertebra in untreated patients, but this relationship was lost in patients who had had brace treatment. Vertebral rotation can easily be measured by ultrasound. This is a harmless and fairly rapid investigation which can be used at routine follow-up examination of patients with idiopathic scoliosis


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 117 - 120
1 Jan 2003
van Douveren FQMP Pruijs HEH Sakkers RJB Nievelstein RAJ Beek FJA

In this prospective study of 18 hips we compared the efficacy of ultrasound with CT in determining the position of the femoral head in a spica cast after closed or open reduction in children with developmental dysplasia of the hip. Ultrasound was performed through the perineal opening of the cast. With a transinguinal approach, the superior ramus of the pubis, the acetabulum, the femoral head and the femoral neck can be depicted in one plane. The CT and ultrasound images were blinded and reviewed by two of the authors. Ultrasound was inconclusive in the first two reductions since the perineal opening was too small to see all the landmarks in one plane. In the following 16 reductions the landmarks were well defined and interpretation of the CT and ultrasound was similar. The perineal opening in the spica cast should be made in such a way that the ultrasound probe can be positioned in the groin so that the landmarks can be shown in one plane


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 7 | Pages 999 - 1005
1 Sep 2003
Sharp RJ Wade CM Hennessy MS Saxby TS

We investigated 29 cases, diagnosed clinically as having Morton’s neuroma, who had undergone MRI and ultrasound before a neurectomy. The accuracy with which pre-operative clinical assessment, ultrasound and MRI had correctly diagnosed the presence of a neuroma were compared with one another based on the histology and the clinical outcome. Clinical assessment was the most sensitive and specific modality. The accuracy of the ultrasound and MRI was similar and dependent on size. Ultrasound was especially inaccurate for small lesions. There was no correlation between the size of the lesion and either the pre-operative pain score or the change in pain score following surgery. Reliance on single modality imaging would have led to inaccurate diagnosis in 18 cases and would have only benefited one patient. Even imaging with both modalities failed to meet the predictive values attained by clinical assessment. There is no requirement for ultrasound or MRI in patients who are thought to have a Morton’s neuroma. Small lesions, < 6 mm in size, are equally able to cause symptoms as larger lesions. Neurectomy provides an excellent clinical outcome in most cases