1 Jul 1997
Heim M Wershavski M Zwas S Siev-Ner I Nadvorna H Azaria M

The use of silicone inner sockets, with or without the incorporation of shuttle locks, has greatly improved the function of artificial limbs. They cushion and protect the stump and provide a means for prosthetic suspension, allowing more comfortable use, especially in patients with ischaemic stumps. They also allow greater movement at the proximal joint


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 448 - 451
1 May 1998
Tanaka M Nakahara S Tanizaki M

We report a patient who developed an aortic pseudoaneurysm in the L3–L4 disc space after lumbar disc surgery. The diagnosis was made by MRI and aortography, and repair using a prosthetic graft and anterior fusion was successful. We discuss the predisposing factors, the clinical picture and management of vascular injuries during disc excision


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 573 - 579
1 May 2020
Krueger DR Guenther K Deml MC Perka C

Aims

We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed.

Methods

All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 634 - 638
1 May 2010
Savarino L Tigani D Greco M Baldini N Giunti A

We investigated the role of ion release in the assessment of fixation of the implant after total knee replacement and hypothesised that ion monitoring could be a useful parameter in the diagnosis of prosthetic loosening. We enrolled 59 patients with unilateral procedures and measured their serum aluminium, titanium, chromium and cobalt ion levels, blinded to the clinical and radiological outcome which was considered to be the reference standard. The cut-off levels for detection of the ions were obtained by measuring the levels in 41 healthy blood donors who had no implants. Based on the clinical and radiological evaluation the patients were divided into two groups with either stable (n = 24) or loosened (n = 35) implants. A significant increase in the mean level of Cr ions was seen in the group with failed implants (p = 0.001). The diagnostic accuracy was 71% providing strong evidence of failure when the level of Cr ions exceeded the cut-off value. The possibility of distinguishing loosening from other causes of failure was demonstrated by the higher diagnostic accuracy of 83%, when considering only patients with failure attributable to loosening. Measurement of the serum level of Cr ions may be of value for detecting failure due to loosening when the diagnosis is in doubt. The other metal ions studies did not have any diagnostic value


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 91 - 96
1 Jun 2019
Smith A Denehy K Ong KL Lau E Hagan D Malkani A

Aims

Cephalomedullary nails (CMNs) are commonly used for the treatment of intertrochanteric hip fractures. Total hip arthroplasty (THA) may be used as a salvage procedure when fixation fails in these patients. The aim of this study was to analyze the complications of THA following failed intertrochanteric hip fracture fixation using a CMN.

Patients and Methods

Patients who underwent THA were identified from the 5% subset of Medicare Parts A/B between 2002 and 2015. A subgroup involving those with an intertrochanteric fracture that was treated using a CMN during the previous five years was identified and compared with the remaining patients who underwent THA. The length of stay (LOS) was compared using both univariate and multivariate analysis. The incidence of infection, dislocation, revision, and re-admission was compared between the two groups, using multivariate analysis adjusted for demographic, hospital, and clinical factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 169 - 170
1 Jan 1991
Sooriakumaran S Landham T

The Klippel-Trenaunay Syndrome is a triad of congenital anomalies characterized by a vascular naevus, varicose veins and hypertrophy of soft tissue and bone. A number of patients affected with this rare syndrome need amputation. In this paper the systemic problems, stump complications and prosthetic difficulties of four amputees with Klippel-Trenaunay syndrome are outlined. The period of follow-up ranged from 10 to 24 years after amputation


Bone & Joint Research
Vol. 9, Issue 5 | Pages 202 - 210
1 May 2020
Trotter AJ Dean R Whitehouse CE Mikalsen J Hill C Brunton-Sim R Kay GL Shakokani M Durst AZE Wain J McNamara I O’Grady J

Aims

This pilot study tested the performance of a rapid assay for diagnosing prosthetic joint infection (PJI), which measures synovial fluid calprotectin from total hip and knee revision patients.

Methods

A convenience series of 69 synovial fluid samples from revision patients at the Norfolk and Norwich University Hospital were collected intraoperatively (52 hips, 17 knees) and frozen. Synovial fluid calprotectin was measured retrospectively using a new commercially available lateral flow assay for PJI diagnosis (Lyfstone AS) and compared to International Consensus Meeting (ICM) 2018 criteria and clinical case review (ICM-CR) gold standards.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 463 - 469
1 Apr 2020
Qin L Hu N Li X Chen Y Wang J Huang W

Aims

Prosthetic joint infection (PJI) remains a major clinical challenge. Neutrophil CD64 index, Fc-gamma receptor 1 (FcγR1), plays an important role in mediating inflammation of bacterial infections and therefore could be a valuable biomarker for PJI. The aim of this study is to compare the neutrophil CD64 index in synovial and blood diagnostic ability with the standard clinical tests for discrimination PJI and aseptic implant failure.

Methods

A total of 50 patients undergoing revision hip and knee arthroplasty were enrolled into a prospective study. According to Musculoskeletal Infection Society (MSIS) criteria, 25 patients were classified as infected and 25 as not infected. In all patients, neutrophil CD64 index and percentage of polymorphonuclear neutrophils (PMN%) in synovial fluid, serum CRP, ESR, and serum CD64 index levels were measured preoperatively. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were analyzed for each biomarker.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 715 - 720
1 Sep 1991
Cooke T Scudamore R Bryant J Sorbie C Siu D Fisher B

A method is described which provides standardised reproducible radiographic images of the lower limb. Anteroposterior and lateral radiographs are digitised and processed by computer to provide graphic/numeric displays of angles and linear measurements, relating the centre points of the hip, knee, and ankle. Two cases illustrate how surgical planning is facilitated when standardised data are available. These data confirm the close relationship between postoperative limb alignment and positioning of prosthetic elements


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 434 - 441
1 Apr 2020
Hamilton DF Burnett R Patton JT MacPherson GJ Simpson AHRW Howie CR Gaston P

Aims

There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes.

Methods

A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints.


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 1 | Pages 144 - 147
1 Feb 1974
Hall AJ

1. A case of late infection about a total knee prosthesis secondary to urinary tract infection is described, indicating that haematogenous spread of infection to a prosthetic joint can occur. 2. The prophylactic use of antibiotics to cover surgical and dental treatment and the energetic treatment of intercurrent infection are urged for patients with artificial joints. 3. Any conservative treatment of established infection in such cases should include complete excision of all necrotic material from the joint


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 640 - 644
1 Jul 1995
Li P Jones N Gregg P

The early diagnosis of aseptic loosening of a total hip replacement by plain radiography, scintigraphy and arthrography has been shown to be unreliable. It has been suggested that it may be possible to distinguish between a secure and a loose prosthesis using a vibration technique. We have assessed the use of this technique in vitro using models of early and late loosening. Late loosening with an unstable prosthesis can be reliably detected by vibration analysis, but this method was shown to have a very poor diagnostic sensitivity in early loosening when there is no obvious prosthetic instability


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 377 - 380
1 May 1991
Macnicol M Penny I Sheppard L

We report the two- to four-year results following the insertion of the Leeds-Keio prosthetic ligament for chronic anterior cruciate deficiency. Virtually all the 20 patients were less disabled by instability, but objective results were good or excellent in only two-thirds and under anaesthesia the pivot shift sign was still positive in half. Arthroscopic and histological assessment in 16 patients failed to show the development of a functional neoligament, and the common appearance of a synovitic reaction to polyester particles gave concern


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 569 - 573
1 Nov 1983
Torode I Gillespie R

The operative technique for combined fusion of the knee and rotationplasty of the limb in the management of congenital deficiency of the femur is presented. The technique described allows earlier definitive prosthetic fitting of a child with proximal femoral deficiency; it has reduced the number of operative procedures needed to obtain the optimal function from that deficient limb; and it has enabled these procedures to be performed at an earlier age. The technique differs from those previously described and represents a significant improvement in management of the patient with femoral deficiency


Bone & Joint 360
Vol. 8, Issue 4 | Pages 29 - 32
1 Aug 2019


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 331 - 339
1 Mar 2019
McEwen P Balendra G Doma K

Aims

The results of kinematic total knee arthroplasty (KTKA) have been reported in terms of limb and component alignment parameters but not in terms of gap laxities and differentials. In kinematic alignment (KA), balance should reflect the asymmetrical balance of the normal knee, not the classic rectangular flexion and extension gaps sought with gap-balanced mechanical axis total knee arthroplasty (MATKA). This paper aims to address the following questions: 1) what factors determine coronal joint congruence as measured on standing radiographs?; 2) is flexion gap asymmetry produced with KA?; 3) does lateral flexion gap laxity affect outcomes?; 4) is lateral flexion gap laxity associated with lateral extension gap laxity?; and 5) can consistent ligament balance be produced without releases?

Patients and Methods

A total of 192 KTKAs completed by a single surgeon using a computer-assisted technique were followed for a mean of 3.5 years (2 to 5). There were 116 male patients (60%) and 76 female patients (40%) with a mean age of 65 years (48 to 88). Outcome measures included intraoperative gap laxity measurements and component positions, as well as joint angles from postoperative three-foot standing radiographs. Patient-reported outcome measures (PROMs) were analyzed in terms of alignment and balance: EuroQol (EQ)-5D visual analogue scale (VAS), Knee Injury and Osteoarthritis Outcome Score (KOOS), KOOS Joint Replacement (JR), and Oxford Knee Score (OKS).


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 402 - 405
1 May 1985
Olerud S Karlstrom G

Six patients with recurrent dislocation after total hip replacement have been treated by fixing an additional sector to the acetabular component. Muscle imbalance or unsatisfactory positioning of the prosthetic components (or both) had caused the dislocations in five patients. In the sixth, a schizophrenic, the dislocations were due to the positions in which the patient placed his limb. At operation a sector was cut from another acetabular prosthesis and screwed on to the previously inserted acetabular component in such a position as to prevent further dislocation. This method has been successful and seems a simple alternative to exchange arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 186 - 188
1 Mar 1989
Chen S Badrinath K Pell L Mitchell K

We aimed to find out whether the Hastings bipolar prosthesis moved in a bipolar fashion after its use for displaced fractures of the femoral neck. In 65 patients non-weight-bearing movement was assessed radiographically and compared with an earlier study of the Monk prosthesis. In 70% of patients, the only movement was between the acetabulum and the prosthetic shell, the prosthesis behaving as if it were unipolar. This did not change with time, but there was a slight improvement in the range of movement, particularly in flexion. The absence of movement between the outer shell and the metal head is most probably due to the design of the prosthesis and makes this prosthesis unsuitable for use in osteoarthritic hips


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 770 - 771
1 Nov 1988
Pring D Marks L Angel J

Management of the failed total knee replacement is a formidable problem. In a 13-year period, 24 patients with above knee amputation following unsuccessful knee replacement were referred for prosthetic limb fitting. Adequate data was available for 23 patients. At review (or at the time of death), an average of 48.6 months after amputation, only seven of the 23 patients were regular daily walkers, although 10 patients had managed to walk for more than two years; 20 of the 23 used a wheelchair for some part of the day and 12 were confined to a wheelchair


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1362 - 1369
1 Nov 2019
Giannicola G Calella P Bigazzi P Mantovani A Spinello P Cinotti G

Aims

The aim of this study was to analyze the results of two radiocapitellar prostheses in a large case series followed prospectively, with medium-term follow-up.

Patients and Methods

A total of 31 patients with a mean age of 54 years (27 to 73) were analyzed; nine had primary osteoarthritis (OA) and 17 had post-traumatic OA, three had capitellar osteonecrosis, and two had a fracture. Overall, 17 Lateral Resurfacing Elbow (LRE) and 14 Uni-Elbow Radio-Capitellum Implant (UNI-E) arthroplasties were performed. Pre- and postoperative assessment involved the Mayo Elbow Performance Score (MEPS), the Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score, and the modified American Shoulder Elbow Surgeons (m-ASES) score.