The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 828 - 829
1 May 2021
Ahmed I Chawla A Underwood M Price AJ Metcalfe A Hutchinson CE Warwick J Seers K Parsons H Wall PDH


Bone & Joint Open
Vol. 2, Issue 2 | Pages 111 - 118
8 Feb 2021
Pettit M Shukla S Zhang J Sunil Kumar KH Khanduja V

Aims

The ongoing COVID-19 pandemic has disrupted and delayed medical and surgical examinations where attendance is required in person. Our article aims to outline the validity of online assessment, the range of benefits to both candidate and assessor, and the challenges to its implementation. In addition, we propose pragmatic suggestions for its introduction into medical assessment.

Methods

We reviewed the literature concerning the present status of online medical and surgical assessment to establish the perceived benefits, limitations, and potential problems with this method of assessment.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1088 - 1095
1 Jun 2021
Banger M Doonan J Rowe P Jones B MacLean A Blyth MJB

Aims

Unicompartmental knee arthroplasty (UKA) is a bone-preserving treatment option for osteoarthritis localized to a single compartment in the knee. The success of the procedure is sensitive to patient selection and alignment errors. Robotic arm-assisted UKA provides technological assistance to intraoperative bony resection accuracy, which is thought to improve ligament balancing. This paper presents the five-year outcomes of a comparison between manual and robotically assisted UKAs.

Methods

The trial design was a prospective, randomized, parallel, single-centre study comparing surgical alignment in patients undergoing UKA for the treatment of medial compartment osteoarthritis (ISRCTN77119437). Participants underwent surgery using either robotic arm-assisted surgery or conventional manual instrumentation. The primary outcome measure (surgical accuracy) has previously been reported, and, along with secondary outcomes, were collected at one-, two-, and five-year timepoints. Analysis of five-year results and longitudinal analysis for all timepoints was performed to compare the two groups.


Bone & Joint 360
Vol. 10, Issue 1 | Pages 24 - 28
1 Feb 2021


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 137 - 144
1 Jun 2021
Lachiewicz PF Steele JR Wellman SS

Aims

To establish our early clinical results of a new total knee arthroplasty (TKA) tibial component introduced in 2013 and compare it to other designs in use at our hospital during the same period.

Methods

This is a retrospective study of 166 (154 patients) consecutive cemented, fixed bearing, posterior-stabilized (PS) TKAs (ATTUNE) at one hospital performed by five surgeons. These were compared with a reference cohort of 511 knees (470 patients) of other designs (seven manufacturers) performed at the same hospital by the same surgeons. There were no significant differences in age, sex, BMI, or follow-up times between the two cohorts. The primary outcome was revision performed or pending.


Bone & Joint Research
Vol. 10, Issue 3 | Pages 166 - 173
1 Mar 2021
Kazezian Z Yu X Ramette M Macdonald W Bull AMJ

Aims

In recent conflicts, most injuries to the limbs are due to blasts resulting in a large number of lower limb amputations. These lead to heterotopic ossification (HO), phantom limb pain (PLP), and functional deficit. The mechanism of blast loading produces a combined fracture and amputation. Therefore, to study these conditions, in vivo models that replicate this combined effect are required. The aim of this study is to develop a preclinical model of blast-induced lower limb amputation.

Methods

Cadaveric Sprague-Dawley rats’ left hindlimbs were exposed to blast waves of 7 to 13 bar burst pressures and 7.76 ms to 12.68 ms positive duration using a shock tube. Radiographs and dissection were used to identify the injuries.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 59 - 66
1 Jun 2021
Abhari S Hsing TM Malkani MM Smith AF Smith LS Mont MA Malkani AL

Aims

Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment.

Methods

A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 809 - 812
1 May 2021
Farhan-Alanie MM Trompeter AJ Wall PDH Costa ML

The use of tourniquets in lower limb trauma surgery to control bleeding and improve the surgical field is a long established practice. In this article, we review the evidence relating to harms and benefits of tourniquet use in lower limb fracture fixation surgery and report the results of a survey on current tourniquet practice among trauma surgeons in the UK.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 7 - 10
1 Apr 2012
Field RE Shimmin A Cattani L

The need to demonstrate probity and fair market competition has increased scrutiny of the relationships between orthopaedic surgeons and the industry that supplies them with their tools and devices. Investigations and judgements from the US Department of Justice and the introduction of the AdvaMed and Eucomed codes have defined new boundaries for interactions between these groups. This article summarises the current interplay between orthopaedic surgeons and industry, and provides recommendations for the future


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 213 - 221
1 Feb 2021
Morgenstern M Kuehl R Zalavras CG McNally M Zimmerli W Burch MA Vandendriessche T Obremskey WT Verhofstad MHJ Metsemakers WJ

Aims

The principle strategies of fracture-related infection (FRI) treatment are debridement, antimicrobial therapy, and implant retention (DAIR) or debridement, antimicrobial therapy, and implant removal/exchange. Increasing the period between fracture fixation and FRI revision surgery is believed to be associated with higher failure rates after DAIR. However, a clear time-related cut-off has never been scientifically defined. This systematic review analyzed the influence of the interval between fracture fixation and FRI revision surgery on success rates after DAIR.

Methods

A systematic literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, in PubMed (including MEDLINE), Embase, and Web of Science Core Collection, investigating the outcome after DAIR procedures of long bone FRIs in clinical studies published until January 2020.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 397 - 403
1 May 1988
Amis A

This study aimed to compare the holding strength of various commercially-available anchorage devices for artificial ligaments, so that surgeons might make a reasoned choice. Tensile tests to failure were performed on screws, bollards, toggles and staples which had been implanted into cadaveric bones. The holding strength of all devices correlated significantly with the local thickness of cortical bone, so it is recommended that anchorages should be placed away from the joint line, into diaphyseal bone if possible. A new trans-cortical grommet was developed which, when used around an AO screw, had significantly greater holding strength than the other devices


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1009 - 1020
1 Jun 2021
Ng N Gaston P Simpson PM Macpherson GJ Patton JT Clement ND

Aims

The aims of this systematic review were to assess the learning curve of semi-active robotic arm-assisted total hip arthroplasty (rTHA), and to compare the accuracy, patient-reported functional outcomes, complications, and survivorship between rTHA and manual total hip arthroplasty (mTHA).

Methods

Searches of PubMed, Medline, and Google Scholar were performed in April 2020 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “hip”, and “arthroplasty”. The criteria for inclusion were published clinical research articles reporting the learning curve for rTHA (robotic arm-assisted only) and those comparing the implantation accuracy, functional outcomes, survivorship, or complications with mTHA.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 407 - 410
1 Mar 2013
Legg AJ Hamer AJ

We have recently shown that waste heat from forced-air warming blankets can increase the temperature and concentration of airborne particles over the surgical site. The mechanism for the increased concentration of particles and their site of origin remained unclear. We therefore attempted to visualise the airflow in theatre over a simulated total knee replacement using neutral-buoyancy helium bubbles. Particles were created using a Rocket PS23 smoke machine positioned below the operating table, a potential area of contamination. The same theatre set-up, warming devices and controls were used as in our previous study. This demonstrated that waste heat from the poorly insulated forced-air warming blanket increased the air temperature on the surgical side of the drape by > 5°C. This created convection currents that rose against the downward unidirectional airflow, causing turbulence over the patient. The convection currents increased the particle concentration 1000-fold (2 174 000 particles/m. 3. for forced-air warming vs 1000 particles/m. 3. for radiant warming and 2000 particles/m. 3. for the control) by drawing potentially contaminated particles from below the operating table into the surgical site. Cite this article: Bone Joint J 2013;95-B:407–10


Bone & Joint 360
Vol. 9, Issue 6 | Pages 18 - 21
1 Dec 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 62 - 67
1 Jan 2003
Price AJ Rees JL Beard D Juszczak E Carter S White S de Steiger R Dodd CAF Gibbons M McLardy-Smith P Goodfellow JW Murray DW

Before proceeding to longer-term studies, we have studied the early clinical results of a new mobile-bearing total knee prosthesis in comparison with an established fixed-bearing device. Patients requiring bilateral knee replacement consented to have their operations under one anaesthetic using one of each prosthesis. They also agreed to accept the random choice of knee (right or left) and to remain ignorant as to which side had which implant. Outcomes were measured using the American Knee Society Score (AKSS), the Oxford Knee Score (OKS), and determination of the range of movement and pain scores before and at one year after operation. Preoperatively, there was no systematic difference between the right and left knees. One patient died in the perioperative period and one mobile-bearing prosthesis required early revision for dislocation of the meniscal component. At one year the mean AKSS, OKS and pain scores for the new device were slightly better (p < 0.025) than those for the fixed-bearing device. There was no difference in the range of movement. We believe that this is the first controlled, blinded trial to compare early function of a new knee prosthesis with that of a standard implant. It demonstrates a small but significant clinical advantage for the mobile-bearing design


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 405 - 410
1 Feb 2021
Leo DG Perry DC Abdullah B Jones H

Aims

The reduction in mobility due to hip diseases in children is likely to affect their physical activity (PA) levels. Physical inactivity negatively influences quality of life and health. Our aim was to objectively measure PA in children with hip disease, and correlate it with the Patient-Reported Outcomes Measurement Information System (PROMIS) Mobility Score.

Methods

A total of 28 children (12 boys and 16 girls) with hip disease aged between 8and 17 years (mean 12 (SD 3)) were studied between December 2018 and July 2019. Children completed the PROMIS Paediatric Item Bank v. 2.0 – Mobility Short Form 8a and wore a hip accelerometer (ActiGraph) for seven consecutive days. Sedentary time (ST), light PA (LPA), moderate to vigorous PA (MVPA), and vigorous PA were calculated from the accelerometers' data. The PROMIS Mobility score was classified as normal, mild, and moderate functions, based on the PROMIS cut scores on the physical function metric. A one-way analysis of covariance (ANCOVA) was used to assess differences among mobility (normal; mild; moderate) and measured PA and relationships between these variables were assessed using bivariate Pearson correlations.


Bone & Joint Open
Vol. 2, Issue 3 | Pages 150 - 163
1 Mar 2021
Flett L Adamson J Barron E Brealey S Corbacho B Costa ML Gedney G Giotakis N Hewitt C Hugill-Jones J Hukins D Keding A McDaid C Mitchell A Northgraves M O'Carroll G Parker A Scantlebury A Stobbart L Torgerson D Turner E Welch C Sharma H

Aims

A pilon fracture is a severe ankle joint injury caused by high-energy trauma, typically affecting men of working age. Although relatively uncommon (5% to 7% of all tibial fractures), this injury causes among the worst functional and health outcomes of any skeletal injury, with a high risk of serious complications and long-term disability, and with devastating consequences on patients’ quality of life and financial prospects. Robust evidence to guide treatment is currently lacking. This study aims to evaluate the clinical and cost-effectiveness of two surgical interventions that are most commonly used to treat pilon fractures.

Methods

A randomized controlled trial (RCT) of 334 adult patients diagnosed with a closed type C pilon fracture will be conducted. Internal locking plate fixation will be compared with external frame fixation. The primary outcome and endpoint will be the Disability Rating Index (a patient self-reported assessment of physical disability) at 12 months. This will also be measured at baseline, three, six, and 24 months after randomization. Secondary outcomes include the Olerud and Molander Ankle Score (OMAS), the five-level EuroQol five-dimenison score (EQ-5D-5L), complications (including bone healing), resource use, work impact, and patient treatment preference. The acceptability of the treatments and study design to patients and health care professionals will be explored through qualitative methods.


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 398 - 404
1 Feb 2021
Christ AB Fujiwara T Yakoub MA Healey JH

Aims

We have evaluated the survivorship, outcomes, and failures of an interlocking, reconstruction-mode stem-sideplate implant used to preserve the native hip joint and achieve proximal fixation when there is little residual femur during large endoprosthetic reconstruction of the distal femur.

Methods

A total of 14 patients underwent primary or revision reconstruction of a large femoral defect with a short remaining proximal femur using an interlocking, reconstruction-mode stem-sideplate for fixation after oncological distal femoral and diaphyseal resections. The implant was attached to a standard endoprosthetic reconstruction system. The implant was attached to a standard endoprosthetic reconstruction system. None of the femoral revisions were amenable to standard cemented or uncemented stem fixation. Patient and disease characteristics, surgical history, final ambulatory status, and Musculoskeletal Tumor Society (MSTS) score were recorded. The percentage of proximal femur remaining was calculated from follow-up radiographs.


Aims

Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures.

Methods

We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 23 - 26
1 Nov 2014
Cooper HJ Della Valle CJ

Dislocation remains among the most common complications of, and reasons for, revision of both primary and revision total hip replacements (THR). Hence, there is great interest in maximising stability to prevent this complication. Head size has been recognised to have a strong influence on the risk of dislocation post-operatively. As femoral head size increases, stability is augmented, secondary to an increase in impingement-free range of movement. Larger head sizes also greatly increase the ‘jump distance’ required for the head to dislocate in an appropriately positioned cup. Level-one studies support the use of larger diameter heads as they decrease the risk of dislocation following primary and revision THR. Highly cross-linked polyethylene has allowed us to increase femoral head size, without a marked increase in wear. However, the thin polyethylene liners necessary to accommodate larger heads may increase the risk of liner fracture and larger heads have also been implicated in causing soft-tissue impingement resulting in groin pain. Larger diameter heads also impart larger forces on the femoral trunnion, which may contribute to corrosion, metal release, and adverse local tissue reactions. Alternative large bearings including large ceramic heads and dual mobility bearings may mitigate some of these risks, and several of these devices have been used with clinical success. Cite this article: Bone Joint J 2014;96-B(11 Suppl A):23–6