Advertisement for orthosearch.org.uk
Results 441 - 460 of over 10000
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1431 - 1437
1 Nov 2009
Biring GS Kostamo T Garbuz DS Masri BA Duncan CP

We report the outcome at ten to 15 years of two-stage revision for hip infection in 99 patients using the Prostalac articulated hip spacer system. All the patients were contacted to determine their current functional and infection status using the Oxford-12, Short form-12, and Western Ontario and McMaster University Osteoarthritis Index questionnaires. A total of 11 of the 99 patients had a further infection, of whom seven responded to repeat surgery with no further sequelae. The mean interval between the stages was five months (1 to 36). We were able to review 48 living patients, with a mean age of 72 years (46 to 86), 34 (71%) of whom provided health-related quality-of-life outcome scores. The mean follow-up was 12 years (10 to 15). The long-term success rate was 89% and with additional surgery this rose to 96%. The mean global Western Ontario and McMaster University Osteoarthritis Index score was 80.6 (. sd. 18.3). The mean Oxford-12 score was 74.0 (. sd. 22.3), and the mean Short form-12 score was 53.1 (. sd. 9.4) (mental) and 33.5 (. sd. 13.5) (physical). The mean satisfaction score was 90.5 (. sd. 15.3). Two-stage revision for hip infection using a Prostalac interim spacer offers a predictable and lasting solution for patients with this difficult problem


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1545 - 1550
1 Nov 2007
Koslowsky TC Mader K Dargel J Koebke J Hellmich M Pennig D

We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability. A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure. The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N. A significantly better quality of reduction was achieved using the FFS wires (Tukey’s post hoc tests, p < 0.001) than with the other devices with a mean step in the articular surface and the radial neck of 1.04 mm (. sd. 0.96) for the FFS, 4.25 mm (. sd. 1.29) for the miniplates, 2.21 mm (. sd. 1.06) for the miniscrews and 2.54 mm (. sd. 0.98) for the K-wires. The quality of reduction was similar for K-wires and miniscrews, but poor for miniplates. The ultimate failure load was similar for the FFS wires (parallel, 196.8 N (. sd. 46.8), perpendicular, 212.5 N (. sd. 25.6)), miniscrews (parallel, 211.8 N (. sd. 47.9), perpendicular, 208.0 N (. sd. 65.9)) and K-wires (parallel, 200.4 N (. sd. 54.5), perpendicular, 165.2 N (. sd. 37.9)), but significantly worse (Tukey’s post hoc tests, p < 0.001) for the miniplates (parallel, 101.6 N (. sd. 43.1), perpendicular, 122.7 N (. sd. 40.7)). There was a significant difference in the displacement at 50 N for the miniplate (parallel, 4.8 mm (. sd. 2.8), perpendicular, 4.8 mm (. sd. 1.7)) vs FFS (parallel, 2.1 mm (. sd. 0.8), perpendicular, 1.9 mm (. sd. 0.7)), miniscrews (parallel, 1.8 mm (. sd. 0.5), perpendicular, 2.3 mm (. sd. 0.8)) and K-wires (parallel, 2.2 mm (. sd. 1.8), perpendicular, 2.4 mm (. sd. 0.7; Tukey’s post hoc tests, p < 0.001)). The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 581 - 585
1 May 2006
Oddy MJ Jones MJ Pendegrass CJ Pilling JR Wimhurst JA

In 20 patients undergoing hybrid total hip arthroplasty, the reproducibility and accuracy of templating using digital radiographs were assessed. Digital images were manipulated using either a ten-pence coin as a marker to scale for magnification, or two digital-line methods using computer software. On-screen images were templated with standard acetate templates and compared with templating performed on hard-copy digital prints. The digital-line methods were the least reliable and accuracy of sizing compared with the inserted prostheses varied between −1.6% and +10.2%. The hard-copy radiographs showed better reproducibility than the ten-pence coin method, but were less accurate with 3.7% undersizing. The ten-pence coin method was the most accurate, with no significant differences for offset or acetabulum, and undersizing of only 0.9%. On-screen templating of digital radiographs with standard acetate templates is accurate and reproducible if a radiopaque marker such as a ten-pence coin is included when the original radiograph is taken


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1113 - 1119
1 Aug 2012
Gjertsen J Lie SA Vinje T Engesæter LB Hallan G Matre K Furnes O

Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kaplan-Meier method and hazard rate ratios (HRR) for revision were calculated using Cox regression analyses. At five years the implant survival was 97% (95% confidence interval (CI) 97 to 97) for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties. Uncemented hemiarthroplasties had a 2.1 times increased risk of revision compared with cemented prostheses (95% confidence interval 1.7 to 2.6, p < 0.001). The increased risk was mainly caused by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening (HRR = 17), haematoma formation (HRR = 5.3), superficial infection (HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications, including intra-operative death, were reported for the cemented hemiarthroplasties. However, in a time-dependent analysis, the HRR for re-operation in both groups increased as follow-up increased. This study showed that the risk for revision was higher for uncemented than for cemented hemiarthroplasties


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1458 - 1462
1 Nov 2015
Langlois J Atlan F Scemama C Courpied JP Hamadouche M

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component. . We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components. . A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed. . After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (. sd. 0.108): in the annealed group it was 0.1382 mm/year (. sd. 0.129) (Mann–Whitney U test, p < 0.001). No complication specific to either material was recorded. These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component. Cite this article: Bone Joint J 2015;97-B:1458–62


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1107 - 1111
1 Aug 2010
Rees JL Dawson J Hand GCR Cooper C Judge A Price AJ Beard DJ Carr AJ

We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions. A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact rotator cuff, 22 for OA with a torn rotator cuff, and 31 for rheumatoid arthritis (RA), were followed up for between three and eight years. All the patients survived, with no revisions or dislocations and no significant radiological evidence of loosening. The mean new Oxford shoulder score (minimum/worst 0, maximum/best 48) improved significantly for all groups (p < 0.001), in the OA group with an intact rotator cuff from 21.4 to 38.8 (effect size 2.9), in the OA group with a torn rotator cuff from 13.3 to 27.2 (effect size 2.1) and in the RA group from 13.7 to 28.0 (effect size 3.1). By this assessment, and for the survival analysis, there was no significant difference between the groups. However, when ratings using the patient satisfaction questions were analysed, eight (29.6%) of the RA group were ‘disappointed’, compared with one (9.1%) of the OA group with cuff intact and one (7.7%) of the OA group with cuff torn. All patients in the OA group with cuff torn indicated that they would undergo the operation again, compared to ten (90.9%) in the OA group with cuff intact and 20 (76.9%) in the RA group. The use of revision rates alone does not fully represent outcome after hemiarthroplasty of the shoulder. Data from PROMs provides more information about change in pain and the ability to undertake activities and perform tasks. The additional use of satisfaction ratings shows that both the rates of revision surgery and PROMs need careful interpretation in the context of patient expectations


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 488 - 492
1 Apr 2012
Vijayan S Bartlett W Bentley G Carrington RWJ Skinner JA Pollock RC Alorjani M Briggs TWR

Matrix-induced autologous chondrocyte implantation (MACI) is an established technique used to treat osteochondral lesions in the knee. For larger osteochondral lesions (> 5 cm. 2. ) deeper than approximately 8 mm we have combined the use of two MACI membranes with impaction grafting of the subchondral bone. We report our results of 14 patients who underwent the ‘bilayer collagen membrane’ technique (BCMT) with a mean follow-up of 5.2 years (2 to 8). There were 12 men and two women with a mean age of 23.6 years (16 to 40). The mean size of the defect was 7.2 cm. 2. (5.2 to 12 cm. 2. ) and were located on the medial (ten) or lateral (four) femoral condyles. The mean modified Cincinnati knee score improved from 45.1 (22 to 70) pre-operatively to 82.8 (34 to 98) at the most recent review (p < 0.05). The visual analogue pain score improved from 7.3 (4 to 10) to 1.7 (0 to 6) (p < 0.05). Twelve patients were considered to have a good or excellent clinical outcome. One graft failed at six years. The BCMT resulted in excellent functional results and durable repair of large and deep osteochondral lesions without a high incidence of graft-related complications


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 455 - 460
1 Apr 2007
Sugano N Nishii T Miki H Yoshikawa H Sato Y Tamura S

We have developed a CT-based navigation system using infrared light-emitting diode markers and an optical camera. We used this system to perform cementless total hip replacement using a ceramic-on-ceramic bearing couple in 53 patients (60 hips) between 1998 and 2001. We reviewed 52 patients (59 hips) at a mean of six years (5 to 8) postoperatively. The mid-term results of total hip replacement using navigation were compared with those of 91 patients (111 hips) who underwent this procedure using the same implants, during the same period, without navigation. There were no significant differences in age, gender, diagnosis, height, weight, body mass index, or pre-operative clinical score between the two groups. The operation time was significantly longer where navigation was used, but there was no significant difference in blood loss or navigation-related complications. With navigation, the acetabular components were placed within the safe zone defined by Lewinnek, while without, 31 of the 111 components were placed outside this zone. There was no significant difference in the Merle d’Aubigne and Postel hip score at the final follow-up. However, hips treated without navigation had a higher rate of dislocation. Revision was performed in two cases undertaken without navigation, one for aseptic acetabular loosening and one for fracture of a ceramic liner, both of which showed evidence of neck impingement on the liner. A further five cases undertaken without navigation showed erosion of the posterior aspect of the neck of the femoral component on the lateral radiographs. These seven impingement-related mechanical problems correlated with malorientation of the acetabular component. There were no such mechanical problems in the navigated group. We conclude that CT-based navigation increased the precision of orientation of the acetabular component and control of limb length in total hip replacement, without navigation-related complications. It also reduced the rate of dislocation and mechanical problems related to impingement


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 361 - 366
1 Mar 2009
Kovoor CC Padmanabhan V Bhaskar D George VV Viswanath S

We present the results of ankle fusion using the Ilizarov technique for bone loss around the ankle in 20 patients. All except one had sustained post-traumatic bone loss. Infection was present in 17. The mean age was 33.1 years (7 to 71). The mean size of the defect was 3.98 cm (1.5 to 12) and associated limb shortening before the index procedure varied from 1 cm to 5 cm. The mean time in the external fixator was 335 days (42 to 870). Tibiotalar fusion was performed in 19 patients and tibiocalcaneal fusion in one. Associated problems included diabetes in one patient, pelvic and urethral injury in one, visual injury in one patient and ipsilateral tibial fracture in five. At the final mean follow-up of 51.55 months (24 to 121) fusion had been achieved in 19 of 20 patients. A total of 16 patients were able to return to work. The results were graded as good in 11 patients, fair in six and poor in three. The mean external fixation index was 8.8 days/mm (0 to 30). One patient with diabetes developed severe infection which required early removal of the fixator. Refractures occurred in three patients, two of which were at the site of fusion and one at a previous tibial shaft fracture site. Equinus deformity of the ankle fusion occurred after a further fracture in one patient. There were two patients with residual forefoot equinus, and one developed late valgus at the fusion site. Poor consolidation of the regenerated bone in two patients was treated by bone grafting in one and by bone and fibular strut grafting in the other. Residual soft-tissue infection was still present in two patients


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1690 - 1694
1 Dec 2010
Scoccianti G Campanacci DA Beltrami G Caldora P Capanna R

Several techniques have been described to reconstruct a mobile wrist joint after resection of the distal radius for tumour. We reviewed our experience of using an osteo-articular allograft to do this in 17 patients with a mean follow-up of 58.9 months (28 to 119). The mean range of movement at the wrist was 56° flexion, 58° extension, 84° supination and 80° pronation. The mean ISOLS-MSTS score was 86% (63% to 97%) and the mean patient-rated wrist evaluation score was 16.5 (3 to 34). There was no local recurrence or distant metastases. The procedure failed in one patient with a fracture of the graft and an arthrodesis was finally required. Union was achieved at the host-graft interface in all except two cases. No patient reported more than modest non-disabling pain and six reported no pain at all. Radiographs showed early degenerative changes at the radiocarpal joint in every patient. A functional pain-free wrist can be restored with an osteo-articular allograft after resection of the distal radius for bone tumour, thereby avoiding the donor site morbidity associated with an autograft. These results may deteriorate with time


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 889 - 892
1 Jul 2008
Al-Shawi A Badge R Bunker T

We have examined the accuracy of 143 consecutive ultrasound scans of patients who subsequently underwent shoulder arthroscopy for rotator-cuff disease. All the scans and subsequent surgery were performed by an orthopaedic surgeon using a portable ultrasound scanner in a one-stop clinic. There were 78 full thickness tears which we confirmed by surgery or MRI. Three moderate-size tears were assessed as partial-thickness at ultrasound scan (false negative) giving a sensitivity of 96.2%. One partially torn and two intact cuffs were over-diagnosed as small full-thickness tears by ultrasound scan (false positive) giving a specificity of 95.4%. This gave a positive predictive value of 96.2% and a negative predictive value of 95.4%. Estimation of tear size was more accurate for large and massive tears at 96.5% than for moderate (88.8%) and small tears (91.6%). These results are equivalent to those obtained by several studies undertaken by experienced radiologists. We conclude that ultrasound imaging of the shoulder performed by a sufficiently-trained orthopaedic surgeon is a reliable time-saving practice to identify rotator-cuff integrity


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1519 - 1521
1 Nov 2007
Khunda A Stirrat AN Dunlop P

The proximal humerus internal locking system is an internal fixation device consisting of a low-profile plate and locking screws, which is used for the fixation of three- and four-part fractures of the proximal humerus. We describe a case in which the screws cut out of the humeral head causing injury to the axillary artery necessitating urgent removal of the implant


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 37 - 43
1 Jan 2009
Hassaballa M Mehendale S Poniatowski S Kalantzis G Smith E Learmonth ID

Loss of bone stock is a major problem in revision surgery of the hip. Impaction bone grafting of the femur is frequently used when dealing with deficient bone stock. In this retrospective study a consecutive series of 68 patients (69 hips) who had revision of a hip replacement with femoral impaction grafting were reviewed. Irradiated bone allograft was used in all hips. Radiological measurement of subsidence of the stem, incorporation of the graft and remodelling was carried out and showed incorporation of the graft in 26 of 69 hips (38%). However, there was no evidence of trabecular remodelling. Moderate subsidence of 5 mm to 10 mm occurred in ten hips (14.5%), and massive subsidence of > 10 mm in five (7.2%). The results of this study are less favourable than those of others describing studies of revision of the femoral stem using impaction bone grafting. The absence of the characteristic changes of graft remodelling noted in other series raises the question as to whether irradiated bone graft may be a significant factor influencing the post-operative outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1041 - 1045
1 Sep 2001
Hutchinson RJ Betts RP Donnan LT Saleh M

Relapsed congenital talipes equinovarus is difficult to assess and treat. Pedobarography provides dynamic measurement of the pressures under the foot, and may be used in the assessment of these patients both before and after operation. Our findings showed a statistically significant difference in the distribution of pressure across the foot after treatment by the Ilizarov technique


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 258 - 263
1 Feb 2008
Parratte S Kilian P Pauly V Champsaur P Argenson JA

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration. Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2°; p < 0.001 and 19.25° with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2°, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane. Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1063 - 1069
1 Aug 2015
Pilge H Holzapfel BM Rechl H Prodinger PM Lampe R Saur U Eisenhart-Rothe R Gollwitzer H

The aim of this study was to analyse the gait pattern, muscle force and functional outcome of patients who had undergone replacement of the proximal tibia for tumour and alloplastic reconstruction of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide local excision of a primary sarcoma of the proximal tibia, proximal tibial replacement and reconstruction of the extensor mechanism using the patellar-loop technique in 18 patients. Of these, nine were available for evaluation after a mean of 11.6 years (0.5 to 21.6). The strength of the knee extensors was measured using an Isobex machine and gait analysis was undertaken in our gait assessment laboratory. Functional outcome was assessed using the American Knee Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time, flexion heel strike, maximal flexion loading response and total sagittal plane excursion. The mean maximum active flexion was 91° (30° to 110°). The overall mean extensor lag was 1° (0° to 5°). The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that in the non-operated leg (p < 0.001). The mean functional scores were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional score). In summary, the results show that reconstruction of the extensor mechanism using this technique gives good biomechanical and functional results. The patients’ gait pattern is close to normal, except for a somewhat stiff knee gait pattern. The strength of the extensor mechanism is reduced, but sufficient for walking. . Cite this article: Bone Joint J 2015;97-B:1063–9


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1442 - 1448
1 Oct 2010
Thompson N Stebbins J Seniorou M Wainwright AM Newham DJ Theologis TN

This study compares the initial outcomes of minimally invasive techniques for single-event multi-level surgery with conventional single-event multi-level surgery. The minimally invasive techniques included derotation osteotomies using closed corticotomy and fixation with titanium elastic nails and percutaneous lengthening of muscles where possible. A prospective cohort study of two matched groups was undertaken. Ten children with diplegic cerebral palsy with a mean age of ten years six months (7.11 to 13.9) had multi-level minimally invasive surgery and were matched for ambulatory level and compared with ten children with a mean age of 11 years four months (7.9 to 14.4) who had conventional single-event multi-level surgery. Gait kinematics, the Gillette Gait Index, isometric muscle strength and gross motor function were assessed before and 12 months after operation. The minimally invasive group had significantly reduced operation time and blood loss with a significantly improved time to mobilisation. There were no complications intra-operatively or during hospitalisation in either group. There was significant improvement in gait kinematics and the Gillette Gait Index in both groups with no difference between them. There was a trend to improved muscle strength in the multi-level group. There was no significant difference in gross motor function between the groups. We consider that minimally invasive single-event multi-level surgery can be achieved safely and effectively with significant advantages over conventional techniques in children with diplegic cerebral palsy


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 54 - 55
1 Jan 1999
Wroblewski BM Siney PD Fleming PA

We report the results of our continued review of 14 hip arthroplasties using alumina ceramic femoral heads with cross-linked polyethylene cups. There have been no complications and a very low rate of penetration. This was 0.02 mm per year after an initial ‘bedding-in’ period of two years. There has been no change in the mean rate between our earlier study at six years and the current results at 10 to 11 years. The use of these bearing surfaces appears to reduce the potential amount of polyethylene debris and may provide the next logical stage in the development of the Charnley low-friction arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1122 - 1129
1 Aug 2007
Watanabe K Tsuchiya H Sakurakichi K Tomita K

The feasibility of bone transport with bone substitute and the factors which are essential for a successful bone transport are unknown. We studied six groups of 12 Japanese white rabbits. Groups A to D received cylindrical autologous bone segments and groups E and F hydroxyapatite prostheses. The periosteum was preserved in group A so that its segments had a blood supply, cells, proteins and scaffold. Group B had no blood supply. Group C had proteins and scaffold and group D had only scaffold. Group E received hydroxyapatite loaded with recombinant human bone morphogenetic protein-2 and group F had hydroxyapatite alone. Distraction osteogenesis occurred in groups A to C and E which had osteo-conductive transport segments loaded with osteo-inductive proteins. We conclude that scaffold and proteins are essential for successful bone transport, and that bone substitute can be used to regenerate bone


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 574 - 577
1 Jul 1990
Atar D Grant A Silver L Lehman W Strongwater A

Primary skin closure after the surgical correction of severe club-foot may be difficult. We describe the use of a tissue expander to provide sufficient skin, and review some aspects of the use of the method