The off-loading characteristics of the cast-braces of 30 patients with fractures of the shaft of the femur have been investigated, during axial loading, using strain-gauge transducers. These were applied at the level of the fracture, where the cast was circumferentially split, and to the hinges of the brace at the knee. They measured the load transferred between the two portions of the thigh cast, and between the thigh cast as a whole and the below-knee cast; by subtraction from the total load on the limb, the skeletal force at the fracture level and at the knee could be calculated. In all patients there was an increase in the fracture load as union progressed which was thought to be due to physiological feedback mechanism from the fracture site. The load carried by the two portions of the thigh cast and by the thigh cast as a whole was proportionately high at first and stabilised at an average of 35 per cent of body weight.
1. Six cases of necrosis of articular cartilage complicating slipping of the upper femoral epiphysis are reviewed: histological examination in one case showed death of the superficial two-thirds of the articular cartilage, with survival of a layer of basal chondrocytes. In all six cases, after severe initial reduction of joint space as seen radiographically, there was gradual return of joint space, suggesting some regeneration of articular cartilage. The prognosis after cartilage necrosis is therefore not always so bad as has been supposed. 2. Various hypotheses concerning the cause of cartilage necrosis complicating slipped epiphysis are reviewed. The precise cause remains unknown, but there is substantial evidence against its being a consequence of ischaemia of the femoral head.
1. Thirteen cases of traumatic separation of the upper femoral epiphysis have been studied. Four were previously reported and nine new cases are analysed. 2. This is a rare injury occurring in young children and is due to severe violence. 3. Separation occurred at the epiphysial plate, and severe posterior displacement was frequent. The fracture line does not penetrate the epiphysis. 4. Premature fusion, avascular necrosis or non-union (individually or together) occurred in eleven of the thirteen patients. 5. Separation of the upper femoral epiphysis is a serious injury which is likely to lead to permanent deformity.
1. Avascular necrosis of the bony epiphysis or necrosis of the articular cartilage of the hip joint–without bony necrosis–can occur after a slipped upper femoral epiphysis. 2. In avascular necrosis of the bony epiphysis the prognosis depends upon the degree of revascularisation that occurs and upon survival of the articular cartilage. The articular cartilage can survive and a good functioning hip result especially if aided by mobilisation without weight bearing. 3. The prognosis after necrosis of the articular cartilage is poor. This complication occurs more often when conservative treatment is used. 4. A certain number of hips will show poor results no matter what treatment is used. 5. Nutrition of the articular cartilage is probably by the synovial fluid. 6. Strong traction may damage the soft-tissue structure of the hip joint. 7. It is not advisable to perform an osteotomy soon after a slip of the epiphysis. It is better to wait until good function is assured in the joint.
Primary uncemented femoral stems reported to the Norwegian arthroplasty register between 1987 and 2005 were included in this prospective observational study. There were 11 516 hips (9679 patients) and 14 different designs of stem. Kaplan-Meier survival probabilities and Cox regression were used to analyse the data. With aseptic loosening as the end-point, all currently used designs performed excellently with survival of 96% to 100% at ten years. With the end-point as stem revision for any cause, the long-term results of the different designs varied from poor to excellent, with survival at 15 years ranging between 29% and 97%. Follow-up for longer than seven years was needed to identify some of the poorly-performing designs. There were differences between the stems; the Corail, used in 5456 hips, was the most frequently used stem with a survival of 97% at 15 years. Male gender was associated with an increased risk of revision of × 1.3 (95% confidence interval 1.05 to 1.52), but age and diagnosis had no influence on the results. Overall, modern uncemented femoral stems performed well. Moderate differences in survival between well-performing stems should be interpreted with caution since the differences may be caused by factors other than the stem itself.
We studied 185 total hip replacements and related the identification of radiolucent lines (RLLs) at two years to the later development of lytic lesions and loosening. Linear polyethylene wear was also measured. RLLs appeared in 34 hips at a mean of 2.0 years after operation, and lytic lesions in ten hips at 5.7 years. Of 151 THRs without RLLs there was neither rapid migration nor loosening and only one developed a possible lytic lesion. Of 23 hips with non-progressive RLLs there was neither rapid migration nor loosening, but six developed a lytic lesion. By contrast, 11 THRs with progressive RLLs migrated rapidly and seven developed a lytic lesion. Six THRs with progressive RLLs failed. The wear rates were the same in all groups, although limited numbers were available for study. If the surgeon achieves secure initial fixation as shown by slow or no migration and no RLLs during the first two years, it is likely that no lytic lesions will develop by five years or aseptic loosening by ten years. If an imperfect, but adequate, interface is achieved, as shown by slow migration and non-progressive RLLs lytic lesions adjacent to the RLLs may develop by five years, but aseptic loosening will be unlikely at ten. Insecure initial fixation, as shown by more rapid migration and progressive RLLs at two years, is likely to lead to the formation of lytic lesions at five years and loosening at ten. The outcome after THR is therefore determined at the initial operation and may be predicted at two years. The presence of lytic lesions reflects soft tissue at the interface as shown by the RLLs which accompany and promote loosening but, in our study, did not cause it.
A leading problem with cementless hip replacement is thigh pain, probably due to some degree of loosening. This is most pronounced during activities such as stair climbing or getting up from a chair. Our study compares the immediate fixation of three stems in widespread clinical use, using a cadaver test simulation in which the femur was horizontal, and cyclic forces acted vertically downward on the prosthetic head with gradual increments of load. We implanted and tested 18 pairs of femurs, making analyses between stem types by right to left comparisons. We found no statistically significant differences in loosening between cementless AML and PCA prostheses, but cemented stems withstood greater loads than uncemented stems by a factor of five or more.
We studied cartilage degeneration in 45 canine acetabula after implantation of prostheses with articulating surfaces of low-temperature isotropic (LTI) pyrolytic carbon, cobalt-chromium-molybdenum alloy and titanium alloy for periods ranging from two weeks to 18 months. Gross specimens and histological sections were compared with the nonoperated (control) acetabulum of the same animal. Cartilage articulating with LTI pyrolytic carbon exhibited significantly lower levels of gross wear, fibrillation, eburnation, glycosaminoglycan loss, and subchondral bone change than with metallic surfaces. Survivorship analysis showed a 92% probability of survival for cartilage articulating with LTI pyrolytic carbon at 18 months, as compared to only a 20% probability of survival for cartilage articulating with either of the metallic alloys.
1. Two new cases of obstetrical separation of the upper femoral epiphysis are described. 2. Diagnosis in the first instance must be largely clinical, because radiological confirmation of the injury may be delayed. 3. The simple method of longitudinal traction is the treatment recommended. 4. It is notable that in our first case the ossification centre of the femoral head appeared at the exceptionally early age of fifteen days.
An experimental method is described which permits observations on the early stages of repair after acute displacement of the upper femoral epiphysis. Because the epiphysis is intra-articular, displacement brings about avascular necrosis which is slowly repaired by ingrowth of callus and blood vessels from the stump of the neck. As the bulk of the epiphysial plate remainsattached to the epiphysis, it acts as a barrier to successful revascularisation. Deliberate removal of the epiphysial cartilage allows earlier revascularisation. It is suggested that in clinical cases reduction be done through the epiphysial plate rather than through the neck, and that it be accompanied by curettage of the remaining part of the epiphysial plate from the under surface of the head.
Aims. Research on hip biomechanics has analyzed femoroacetabular contact pressures and forces in distinct hip conditions, with different procedures, and used diverse loading and testing conditions. The aim of this scoping review was to identify and summarize the available evidence in the literature for hip contact pressures and force in cadaver and in vivo studies, and how joint loading, labral status, and
Aims. Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a
Aims. Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered
The radiological features of the cement mantle around total hip replacements (THRs) have been used to assess aseptic loosening. In this case-control study we investigated the risk of failure of THR as predictable by a range of such features using data from patients recruited to the Trent Regional Arthroplasty Study (TRAS). An independent radiological assessment was undertaken on Charnley THRs with aseptic loosening within five years of surgery and on a control group from the TRAS database. Chi-squared tests were used to test the probability of obtaining the observed data by chance, and odds ratios were calculated to estimate the strength of association for different features. Several features were associated with a clinically important increase (>
twofold) in the risk of loosening, which was statistically significant for four features (p <
0.01). Inadequate cementation (Barrack C and D grades) was the most significant feature, with an estimated odds ratio of 9.5 (95% confidence interval 3.2 to 28.4, p <
0.0001) for failure.
Aims. Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. Methods. A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken. Results. Of 263 studies, 12 were included with a total of 3,861 TKAs. Meta-analysis of ten studies showed high rates of overall tibial or