We report a prospective study of the
We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with femoral revision
A case of osteogenesis imperfecta, presenting with bowed deformity of both forearm bones and dislocation of the radial head was treated by separate elongation of both bones
In 13 patients (18 fingers) we
Loosening is a serious problem in total arthroplasty and early detection of bone loss in the vicinity of an implant would help in its investigation. We present a method for the objective evaluation of bone adjacent to metallic implants in which a modified technique of quantitative computed tomography (QCT) is
Animal experiments are reported in which porous titanium plugs were
Using an osteotomy of the olecranon as a model of a transverse fracture in 22 cadaver elbows we determined the ability of three different types of suture and stainless steel wire to maintain reduction when
The management of carpal dislocation after a late diagnosis is difficult. Open reduction is the usual treatment but collapse of the carpus may be hard to overcome without extensive dissection and consequent damage to the blood supply, ligaments and articular cartilage. A technique of distraction by an external fixator followed by semi-closed reduction is described and its successful
We evaluated triple-phase bone scintigraphy in the differential diagnosis of peri-prosthetic infection in 46 patients with a total hip replacement or bipolar hemiarthroplasty who were due for revision surgery. There were 18 men and 28 women, with a mean age at operation of 64.6 years (28 to 81). We defined peri-prosthetic infection as an increased uptake of radioisotope in all the phases of triple-phase bone scintigraphy and validated these results against the histological and/or microbiology results in every case. The positive and negative predictive values for the presence of infection were 83% and 93%, respectively. The diagnostic sensitivity was 88% and the specificity was 90%. This study indicates that triple-phase bone scintigraphy is a useful tool in the detection of peri-prosthetic infection and offers a cost-effective method of screening.
We
We describe the
We
We have reviewed 13 operations on 11 patients
The Kodama-Yamamoto knee is an uncemented surface replacement which has been
The operative and anaesthesic technique for 44 patients undergoing posterior spinal fusion with Harrington rod instrumentation for idiopathic scoliosis is described. There were two groups of 21 and 23 patients, matched for diagnosis and status before operation. The management of both groups was similar but in one group anaesthesia with induced hypotension was employed,
We evaluated all cases involving the combined
We describe our early operative experience with a new pelvic reduction frame and the standard of reduction of fractures of the pelvic ring which we achieved in the first 35 consecutive patients, with 34 acute fractures and one nonunion. The pre-operative and immediate post-operative radiographs were measured,
We compared the long-term function of subscapularis after the Latarjet procedure
We present a series of 114 patients with microbiologically-proven chronically-infected total hip replacement, treated between 1991 and 2004 by a two-stage exchange procedure with antibiotic-loaded cement, but without the