This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant.Aims
Methods
As there is little information on the factors that influence fracture union following
We reviewed 63 patients with fractures of the distal tibial metaphysis, with or without minimally displaced extension into the ankle joint. The fractures had been caused by two distinct mechanisms, either a direct bending force or a twisting injury. This influenced the pattern of the fracture and its time to union. All fractures were managed by statically locked
The case reports of four patients with breakage of the
1. A method of hip fusion with the aid of a straight
Fractures of the femur are the most incapacitating fractures in children. Conservative treatment necessitates a long stay in hospital for traction and subsequent immobilisation in an uncomfortable cast. This treatment is not well tolerated, especially in adolescents. Moreover, near the end of growth, accurate reduction is necessary, as malunion is no longer correctable by growth. Stable elastic
We describe a patient with fractures of both bones of the forearm in whom flexible
We made a prospective study of 208 patients with tibial fractures treated by reamed
There is concern about the incidence and serious nature of infection after
We report the use of elastic stable
We used 15 pairs of femora from fresh human cadavers to study the effects of the size and location of the entry hole for an
Exchange nailing for failure of union after primary
We have studied the medium- and long-term effects of femoral
In two hospitals, 115 consecutive open femoral shaft fractures were treated by meticulous wound excision and early locked (97) or unlocked (18)
In a consecutive series of 498 patients with 528 fractures of the femur treated by conventional interlocking
We randomised prospectively 44 patients with fractures of the shaft of the humerus to open reduction and internal fixation by either an
We report a prospective study of 26 cases of fracture of the distal third of the femur treated with the Derby
We measured the changes during operation in seven markers of coagulation in a prospective series of 84 patients with fractures of the tibia or femur who were undergoing reamed
Ten patients with humeral shaft fractures and no clinical or radiographic signs of healing after at least six weeks' immobilisation were treated by flexible