The aim of this study was to record the incidence of post-traumatic
osteoarthritis (OA), the need for total hip arthroplasty (THA),
and patient-reported outcome measures (PROMS) after surgery for
a fracture of the acetabulum, in our centre. All patients who underwent surgery for an acetabular fracture
between 2004 and 2014 were included. Patients completed the 36-Item
Short Form Health Survey (SF-36) and the modified Harris Hip Score
(mHHS) questionnaires. A retrospective chart and radiographic review
was performed on all patients. CT scans were used to assess the classification
of the fracture and the quality of reduction.Aims
Patients and Methods
Injury to the sciatic nerve following closed manipulation of a dislocated total hip replacement is rare. We present such a case in an elderly patient with partial recovery following exploration and release of the nerve.
Modular or custom-made femoral components have been preferred
for total hip arthroplasty (THA) in patients with a history of Perthes’
disease because of the distortion in the anatomy of the proximal
femur. However, it has not been established whether a monobloc cementless
stem will fit the distorted proximal femur or whether the results
of the procedure are satisfactory in this group of patients. We reviewed 68 consecutive patients who had undergone THA for
childhood Perthes’ disease between June 2003 and December 2008.
There were 35 men and 33 women with a mean age of 48 years (16 to
73) at the time of index arthroplasty. Their mean body mass index
was 24.4 (18.3 to 32.9). Of the 68 hips, 32 were classified as Stulberg
class III and 36 as class IV. The mean pre-operative shortening
of the affected leg was 17.2 mm (5 to 34). The minimum follow-up
was five years (mean 8.5 years; 5.2 to 10).Aims
Patients and Methods
To evaluate the outcomes of cemented total hip arthroplasty (THA)
following a fracture of the acetabulum, with evaluation of risk
factors and comparison with a patient group with no history of fracture. Between 1992 and 2016, 49 patients (33 male) with mean age of
57 years (25 to 87) underwent cemented THA at a mean of 6.5 years
(0.1 to 25) following acetabular fracture. A total of 38 had undergone
surgical fixation and 11 had been treated non-operatively; 13 patients
died at a mean of 10.2 years after THA (0.6 to 19). Patients were
assessed pre-operatively, at one year and at final follow-up (mean
9.1 years, 0.5 to 23) using the Oxford Hip Score (OHS). Implant
survivorship was assessed. An age and gender-matched cohort of THAs
performed for non-traumatic osteoarthritis (OA) or avascular necrosis
(AVN) (n = 98) were used to compare complications and patient-reported outcome
measures (PROMs).Aims
Patients and Methods
The aim of this study was to evaluate the long-term clinical
and radiographic outcomes of the Birmingham Interlocking Pelvic
Osteotomy (BIPO). In this prospective study, we report the mid- to long-term clinical
outcomes of the first 100 consecutive patients (116 hips; 88 in
women, 28 in men) undergoing BIPO, reflecting the surgeon’s learning
curve. Failure was defined as conversion to hip arthroplasty. The
mean age at operation was 31 years (7 to 57). Three patients (three
hips) were lost to follow-up.Aims
Patients and Methods
Joint-preserving surgery of the hip (JPSH) has evolved considerably
and now includes a number of procedures, including arthroscopy,
surgical dislocation, and redirectional osteotomies of the femur
and acetabulum. There are a number of different factors which lead
to failure of JPSH. Consequently, it is of interest to assess the
various modes of failure in order to continue to identify best practice
and the indications for these procedures. Using a retrospective observational study design, we reviewed
1013 patients who had undergone JPSH by a single surgeon between
2005 and 2015. There were 509 men and 504 women with a mean age
of 39 years (16 to 78). Of the 1013 operations, 783 were arthroscopies,
122 surgical dislocations, and 108 peri-acetabular osteotomies (PAO).
We analysed the overall failure rates and modes of failure. Re-operations
were categorised into four groups: Mode 1 was arthritis progression
or organ failure leading to total hip arthroplasty (THA); Mode 2
was an Incorrect diagnosis/procedure; Mode 3 resulted from malcorrection
of femur (type A), acetabulum (type B), or labrum (type C) and Mode 4
resulted from an unintended consequence of the initial surgical
intervention.Aims
Patients and Methods
The purpose of our study is to summarise the current scientific
findings regarding the impact of obesity on total hip arthroplasty
(THA); specifically the influence of obesity on the timing of THA,
incidence of complications, and effect on clinical and functional
outcomes. We performed a systematic review that was compliant with the
Preferred Reporting Items for Systematic Reviews and Meta-Analyses
guidelines to identify prospective studies from the PubMed/Medline,
Embase, and Cochrane Library databases that evaluated primary THA
in obese (body mass index (BMI) ≥ 30 kg/m2) patients.Aims
Materials and Methods
Few studies dealing with chondrosarcoma of the pelvis are currently
available. Different data about the overall survival and prognostic
factors have been published but without a detailed analysis of surgery-related complications.
We aimed to analyse the outcome of a series of pelvic chondrosarcomas
treated at a single institution, with particular attention to the
prognostic factors. Based on a competing risk model, our objective
was to identify risk factors for the development of complications. In a retrospective single-centre study, 58 chondrosarcomas (26
patients alive, 32 patients dead) of the pelvis were reviewed. The
mean follow-up was 13 years (one week to 23.1 years).Aims
Patients and Methods
Peripheral nerve injury is an uncommon but serious
complication of hip surgery that can adversely affect the outcome.
Several studies have described the use of electromyography and intra-operative
sensory evoked potentials for early warning of nerve injury. We
assessed the results of multimodal intra-operative monitoring during
complex hip surgery. We retrospectively analysed data collected
between 2001 and 2010 from 69 patients who underwent complex hip
surgery by a single surgeon using multimodal intra-operative monitoring
from a total pool of 7894 patients who underwent hip surgery during
this period. In 24 (35%) procedures the surgeon was alerted to a
possible lesion to the sciatic and/or femoral nerve. Alerts were
observed most frequently during peri-acetabular osteotomy. The surgeon
adapted his approach based on interpretation of the neurophysiological changes.
From 69 monitored surgical procedures, there was only one true positive
case of post-operative nerve injury. There were no false positives
or false negatives, and the remaining 68 cases were all true negative.
The sensitivity for predicting post-operative nerve injury was 100%
and the specificity 100%. We conclude that it is possible and appropriate
to use this method during complex hip surgery and it is effective
for alerting the surgeon to the possibility of nerve injury.
Several studies have reported the rate of post-operative
mortality after the surgical treatment of a fracture of the hip,
but few data are available regarding the delayed morbidity. In this
prospective study, we identified 568 patients who underwent surgery
for a fracture of the hip and who were followed for one year. Multivariate
analysis was carried out to identify possible predictors of mortality
and morbidity. The 30-day, four-month and one-year rates of mortality
were 4.3%, 11.4%, and 18.8%, respectively. General complications
and pre-operative comorbidities represented the basic predictors
of mortality at any time interval (p <
0.01). In-hospital, four-month
and one-year general complications occurred in 29.4%, 18.6% and
6.7% of patients, respectively. After adjusting for confounding variables,
comorbidities and poor cognitive status determined the likelihood
of early and delayed general complications, respectively (p <
0.001). Operative delay was the main predictor of the length of
hospital stay (p <
0.001) and was directly related to in-hospital
(p = 0.017) and four-month complications (p = 0.008). Cite this article:
We report the outcome of 161 of 257 surgically fixed acetabular fractures. The operations were undertaken between 1989 and 1998 and the patients were followed for a minimum of ten years. Anthropometric data, fracture pattern, time to surgery, associated injuries, surgical approach, complications and outcome were recorded. Modified Merle D’Aubigné score and Matta radiological scoring systems were used as outcome measures. We observed simple fractures in 108 patients (42%) and associated fractures in 149 (58%). The result was excellent in 75 patients (47%), good in 41 (25%), fair in 12 (7%) and poor in 33 (20%). Poor prognostic factors included increasing age, delay to surgery, quality of reduction and some fracture patterns. Complications were common in the medium- to long-term and functional outcome was variable. The gold-standard treatment for displaced acetabular fractures remains open reduction and internal fixation performed in dedicated units by specialist surgeons as soon as possible.
Extendible endoprostheses have been available for more than 30
years and have become more sophisticated with time. The latest generation
is ‘non-invasive’ and can be lengthened with an external magnetic
force. Early results have shown a worryingly high rate of complications
such as infection. This study investigates the incidence of complications
and the need for further surgery in a cohort of patients with a
non-invasive growing endoprosthesis. Between 2003 and June 2014, 50 children (51 prostheses) had a
non-invasive growing prosthesis implanted for a primary bone sarcoma.
The minimum follow-up was 24 months for those who survived. Their
mean age was 10.4 years (6 to 14). The incidence of complications
and further surgery was documented.Aims
Patients and Methods
Pelvic discontinuity represents a rare but challenging
problem for orthopaedic surgeons. It is most commonly encountered
during revision total hip replacement, but can also result from
an iatrogentic acetabular fracture during hip replacement. The general
principles in management of pelvic discontinuity include restoration
of the continuity between the ilium and the ischium, typically with
some form of plating. Bone grafting is frequently required to restore
pelvic bone stock. The acetabular component is then impacted, typically
using an uncemented, trabecular metal component. Fixation with multiple
supplemental screws is performed. For larger defects, a so-called
‘cup–cage’ reconstruction, or a custom triflange implant may be
required. Pre-operative CT scanning can greatly assist in planning
and evaluating the remaining bone stock available for bony ingrowth.
Generally, good results have been reported for constructs that restore
stability to the pelvis and allow some form of biologic ingrowth. Cite this article:
Hip replacement is a very successful operation and the outcome is usually excellent. There are recognised complications that seem increasingly to give rise to litigation. This paper briefly examines some common scenarios where litigation may be pursued against hip surgeons. With appropriate record keeping, consenting and surgical care, the claim can be successfully defended if not avoided. We hope this short summary will help to highlight some common pitfalls. There is extensive literature available for detailed study.
To investigate the longevity of uncemented fixation of a femoral
component in total hip arthroplasty (THA) in patients with Dorr
type C proximal femoral morphology. A total of 350 consecutive uncemented THA in 320 patients were
performed between 1983 and 1987, by a single surgeon using the Taperloc
femoral component. The 63 patients (68 hips) with Dorr type C proximal
femoral morphology were the focus of this review. The mean age of
the patients was 69 years (24 to 88) and mean follow-up was 16.6
years (ten to 29). Survival analysis included eight patients (eight
hips) who died without undergoing revision surgery prior to obtaining
ten years follow-up. All 55 surviving patients (60 hips) were available
for clinical assessment and radiographic review. As a comparator
group, the survival and implant fixation in the remaining 282 THAs
(257 patients) with Dorr type A and B morphology were evaluated.
The mean age of these patients was 52 years (20 to 82).Aims
Patients and Methods
The October 2013 Hip &
Pelvis Roundup360 looks at: Young and impinging; Clothes, weather and femoral heads?; Go long, go cemented; Surgical repair of the abductors?; Aspirin for DVT prophylaxis?; Ceramic-on-polyethylene: a low-wear solution?; ALVAL and ASR™: the story continues….; Salvaging Legg-Calve-Perthes’ disease
Revision total hip arthroplasty (THA) is challenging
when there is severe loss of bone in the proximal femur. The purpose
of this study was to evaluate the clinical and radiographic outcomes
of revision THA in patients with severe proximal femoral bone loss
treated with a fluted, tapered, modular femoral component. Between
January 1998 and December 2004, 92 revision THAs were performed
in 92 patients using a single fluted, tapered, modular femoral stem
design. Pre-operative diagnoses included aseptic loosening, infection
and peri-prosthetic fracture. Bone loss was categorised pre-operatively
as Paprosky types III-IV, or Vancouver B3 in patients with a peri-prosthetic
fracture. The mean clinical follow-up was 6.4 years (2 to 12). A
total of 47 patients had peri-operative complications, 27 of whom
required further surgery. However, most of these further operations
involved retention of a well-fixed femoral stem, and 88/92 femoral
components (97%) remained Revision THA in patients with extensive proximal femoral bone
loss using the Link MP fluted, tapered, modular stem led to a high
rate of osseointegration of the stem at mid-term follow-up. Cite this article:
We evaluated an operative technique, described
by the Exeter Hip Unit, to assist accurate introduction of the femoral
component. We assessed whether it led to a reduction in the rate
of leg-length discrepancy after total hip arthroplasty (THA). A total of 100 patients undergoing THA were studied retrospectively;
50 were undertaken using the test method and 50 using conventional
methods as a control group. The groups were matched with respect
to patient demographics and the grade of surgeon. Three observers
measured the depth of placement of the femoral component on post-operative
radiographs and measured the length of the legs. There was a strong correlation between the depth of insertion
of the femoral component and the templated depth in the test group
(R = 0.92), suggesting accuracy of the technique. The mean leg-length
discrepancy was 5.1 mm (0.6 to 21.4) pre-operatively and 1.3 mm
(0.2 to 9.3) post-operatively. There was no difference between Consultants
and Registrars as primary surgeons. Agreement between the templated
and post-operative depth of insertion was associated with reduced
post-operative leg-length discrepancy. The intra-class coefficient
was R ≥ 0.88 for all measurements, indicating high observer agreement.
The post-operative leg-length discrepancy was significantly lower
in the test group (1.3 mm) compared with the control group (6.3
mm, p <
0.001). The Exeter technique is reproducible and leads to a lower incidence
of leg-length discrepancy after THA. Cite this article:
The October 2014 Hip &
Pelvis Roundup360 looks at: functional acetabular orientation; predicting re-admission following THR; metal ions and resurfacing; lipped liners increase stability; all anaesthetics equal in hip fracture surgery; revision hip surgery in very young patients; and uncemented hips.
Acetabular bone loss is a challenging problem
facing the revision total hip replacement surgeon. Reconstruction
of the acetabulum depends on the presence of anterosuperior and
posteroinferior pelvic column support for component fixation and
stability. The Paprosky classification is most commonly used when
determining the location and degree of acetabular bone loss. Augments
serve the function of either providing primary construct stability
or supplementary fixation. When a pelvic discontinuity is encountered we advocate the use
of an acetabular distraction technique with a jumbo cup and modular
porous metal acetabular augments for the treatment of severe acetabular
bone loss and associated chronic pelvic discontinuity. Cite this article: