Aims. The COVID-19 pandemic led to a national suspension of “non-urgent” elective hip and knee arthroplasty. The study aims to measure the effect of the COVID-19 pandemic on total hip arthroplasty (THA) and
Aims. Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in
Aims. The Coronal Plane Alignment of the Knee (CPAK) classification is a simple and comprehensive system for predicting pre-arthritic knee alignment. However, when the CPAK classification is applied in the Asian population, which is characterized by more varus and wider distribution in lower limb alignment, modifications in the boundaries of arithmetic hip-knee-ankle angle (aHKA) and joint line obliquity (JLO) should be considered. The purposes of this study were as follows: first, to propose a modified CPAK classification based on the actual joint line obliquity (aJLO) and wider range of aHKA in the Asian population; second, to test this classification in a cohort of Asians with healthy knees; third, to propose individualized alignment targets for different CPAK types in kinematically aligned (KA)
We studied the effects of the timing of tourniquet release in 88 patients randomly allocated for release after wound closure and bandaging (group A), or before the quadriceps layer had been closed allowing control of bleeding before suture (group B). The groups were similar in mean age, weight, gender, preoperative knee score, radiographic grading, and prosthesis implanted. Patients in group B had less postoperative pain, achieved earlier straight-leg raising, and had fewer wound complications. Five patients in group A had to return to theatre, three for manipulation under anaesthesia, one for secondary closure of wound dehiscence, and one for drainage of a haematoma. The last patient later developed a deep infection, which was treated by a two-stage revision. There were no significant differences between the two groups in operating time, or the decrease in haemoglobin concentration at 48 hours postoperatively. Some of the adverse effects of the use of a tourniquet for knee surgery can be significantly reduced by early tourniquet release, with haemostasis before the quadriceps mechanism and the wound are closed.
Aims. The purpose of this study was to assess
We report a prospective case-controlled study which compared the outcome of knee replacement in seriously deformed and slightly deformed knees. There were 51 knees with varus or valgus deformity greater than 20 degrees matched for age, gender, disease, type of prosthesis and time of operation with a control group in which the alignment of the leg was within 5 degrees of normal. The clinical outcome at a mean 5.5 years was similar in the two groups. Some deformity persisted in 14 patients in the first group, 13 of whom were initially in valgus. These patients had a significantly poorer mean clinical outcome. Lateral dislocation or subluxation of the patella was found in four knees, all of which had had valgus deformity of 30 degrees or more.
We review 210 Stanmore knee replacements in 163 patients to assess the survival of the prostheses and the long-term results. The annual rate of failure reached a maximum of 4.6% in the fourth year after operation; thereafter it declined to reach zero by the eighth year. Between two and eight years after operation, 66.3% of the surviving knees were completely free of pain and 30.2% had mild retropatellar pain. Fixed flexion deformities present before operation were completely corrected in 73% of the knees, and varus or valgus deformities were invariably corrected. Stability was always restored to unstable knees and 80.8% of knees flexed to 90 degrees or more after replacement. Aseptic loosening (8.1%), prosthetic infection (4.3%) and femoral fracture (2.9%) led to 8.5% of the prostheses being revised or removed over eight years. Modifications in prosthetic design and operative techniques have been introduced to minimise such complications in the future.
Aims. The optimum type of antibiotics and their administration route for treating Gram-negative (GN) periprosthetic joint infection (PJI) remain controversial. This study aimed to determine the GN bacterial species and antibacterial resistance rates related to clinical GN-PJI, and to determine the efficacy and safety of intra-articular (IA) antibiotic injection after one-stage revision in a GN pathogen-induced PJI rat model of
The Bisurface knee prosthesis (BP) has a posterior stabilising cam (ball-and-socket joint) in the mid-posterior region of the femorotibial joint in an attempt to improve the range of movement. Based on an in vitro weight-bearing study contact areas of the Insall/Burstein 2 (IB2) and the BP knee were compared using pressure-sensitive films. The stability afforded by the cam was evaluated by means of dislocation distances in the vertical and horizontal planes. Significant adverse anterior translation in mid-flexion was not observed with the BP knee since the cam was effective above 60° of flexion. At flexion of 60° or more, the total contact areas were larger, as the cam represented a weight-bearing surface. The dislocation distances for the BP knee compared favourably with those for the IB2 knee. We conclude that the cam of the BP knee allows good movement, stability and wear.
Aims. The patient-acceptable symptom state (PASS) is a level of wellbeing, which is measured by the patient. The aim of this study was to determine if the proportion of patients who achieved an acceptable level of function (PASS) after medial unicompartmental knee arthroplasty (UKA) was different based on the status of the anterior cruciate ligament (ACL) at the time of surgery. Methods. A total of 114 patients who underwent UKA for isolated medial osteoarthritis (OA) of the knee were included in the study. Their mean age was 65 years (SD 10). No patient underwent a bilateral procedure. Those who had undergone ACL reconstruction during the previous five years were excluded. The Knee injury Osteoarthritis Outcome Score Activities of Daily Living (KOOS ADL) function score was used as the primary outcome measure with a PASS of 87.5, as described for
Aims. The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted
We reviewed 1567 elective knee replacements performed between 1980 and 1990, using either the Total Condylar prosthesis with an all-plastic tibial component, or the Kinematic prosthesis which has a metal tibial tray. The ten-year probability of survival was 92.1% for the Total Condylar design and 87.9% for the Kinematic. The difference was mainly due to 16 revisions required in the Kinematic series for fracture of the metal base-plate. This was the most common cause of aseptic failure in this group. These fractures were strongly associated with a preoperative varus deformity (hazard ratio (HR) 8.8) and there was a slightly increased risk in males (HR 1.9) and in osteoarthritic knees (HR 1.8). In the nine fractures which occurred within four years of primary implantation (group 1), failure to correct adequately a preoperative varus deformity and the use of a bone graft to correct such a deformity were both strongly associated with fracture (HR 13.9 and 15.8, respectively). In eight fractures which occurred more than five years after primary replacement (group 2) we could detect no significant risk factors. Early complications occurred in two patients after the 16 revision procedures for tray fracture. One had a deep infection and the other refracture of the tray.
Aims. This study aimed to compare the effect of antibiotic-loaded bone cement (ALBC) versus plain bone cement (PBC) on revision rates for periprosthetic joint infection (PJI) and all-cause revisions following primary elective total hip arthroplasty (THA) and
We performed a prospective randomised controlled trial of a new mechanical method of prophylaxis for venous thrombo-embolism in 60 patients undergoing knee replacement surgery. The method uses the A-V Impulse System to produce cyclical compression of the venous reservoir of the foot. The overall incidence of deep-vein thrombosis was 68.7% in patients receiving no prophylaxis and 50% in those using the device. The difference was not significant. There was, however, a reduction of the extent of thrombosis in the treated group. There were 13 major calf-vein thrombi and six proximal-vein thrombi in the control group compared with only five major calf-vein thrombi in the treated group. This difference was significant (p = 0.014). No patient developed clinical features of a pulmonary embolism.
In a prospective study of 100 knee arthroplasties in patients with rheumatoid arthritis, simultaneous bilateral surgery was compared with staged bilateral replacements. All patients had improved function following their operations but those who had staged surgery only achieved maximum benefit after the second knee had been replaced. The complication rate was no greater for simultaneous surgery and we therefore advocate the method for those patients who require bilateral replacements.
Aims. The aim of this study was to report patient and clinical outcomes following robotic-assisted
Aims. The aims of this study were to evaluate wear on the surface of cobalt-chromium (CoCr) femoral components used in