Advertisement for orthosearch.org.uk
Results 621 - 640 of over 10000
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 473 - 474
1 May 2000
Amstutz HC Dorey FJ


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 743 - 743
1 Jul 1998
SILAS SI


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 370 - 370
1 Mar 1998
QUINT U


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 157 - 158
1 Jan 1995
Johnson T McGanity P


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 673 - 675
1 Jul 1994
Coventry M


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 453 - 457
1 May 1986
Paterson F Trickey E

We have reviewed 40 patients after replacement of a ruptured anterior cruciate ligament with a free graft of the medial third of the patellar tendon, combining this in 17 of the cases with a MacIntosh extra-articular tenodesis. The average age of the patients at operation was 25.4 years; instability of the knee had been present for 1.5 to 9 years, and the mean follow-up was 2.9 years. The results, assessed on subjective stability, were good in 29 patients, over half being able to return to their original sport, and fair in eight. The technique of operation for free patellar tendon grafting is described in detail and the indications for this and for an additional MacIntosh tenodesis are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1610 - 1612
1 Dec 2006
Al-Rashid M Theivendran K Craigen MAC

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 167 - 172
1 Feb 2012
Buttaro MA Costantini J Comba F Piccaluga F

We determined the midterm survival, incidence of peri-prosthetic fracture and the enhancement of the width of the femur when combining struts and impacted bone allografts in 24 patients (25 hips) with severe femoral bone loss who underwent revision hip surgery. The pre-operative diagnosis was aseptic loosening in 16 hips, second-stage reconstruction in seven, peri-prosthetic fracture in one and stem fracture in one hip. A total of 14 hips presented with an Endoklinik grade 4 defect and 11 hips a grade 3 defect. The mean pre-operative Merle D’Aubigné and Postel score was 5.5 points (1 to 8). The survivorship was 96% (95% confidence interval 72 to 98) at a mean of 54.5 months (36 to 109). The mean functional score was 17.3 points (16 to 18). One patient in which the strut did not completely bypass the femoral defect was further revised using a long cemented stem due to peri-prosthetic fracture at six months post-operatively. The mean subsidence of the stem was 1.6 mm (1 to 3). There was no evidence of osteolysis, resorption or radiolucencies during follow-up in any hip. Femoral width was enhanced by a mean of 41% (19% to 82%). A total of 24 hips had partial or complete bridging of the strut allografts. This combined biological method was associated with a favourable survivorship, a low incidence of peri-prosthetic fracture and enhancement of the width of the femur in revision total hip replacement in patients with severe proximal femoral bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 210 - 214
1 Apr 1982
Partridge A Evans P


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 3 | Pages 362 - 366
1 Aug 1981
Buxton R

The treatment of fractures of the femoral shaft by traction may delay union and produce stiffness of the knee. The technique of Perkins' method is described and the results reported in 50 cases. All patients had at least 120 degrees of flexion of the knee when traction was discontinued, and 47 patients were considered to have clinical and radiological union of the fracture by 12 weeks. The main complications of the method was loosening of the Denham pin or infection of the pin-track in the proximal tibia. It is suggested that Perkins' traction is an excellent form of treatment for fractures of the femoral shaft, and has several advantages over other forms of traction.


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 4 | Pages 465 - 470
1 Nov 1980
de Haas W Watson J Morrison D

A non-invasive method of electrical stimulation of healing in ununited fractures of the tibia by pulsed magnetic fileds has been evaluated. In a series of 17 patients all but two of the fractures united within 4 to 10 months, with an average time of just under six months. The method is sufficiently promising to merit further clinical investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 57-B, Issue 4 | Pages 478 - 481
1 Nov 1975
Henry APJ Waugh W Wood H

One hundred and seventy feet have been reviewed after operations for hallux valgus; eighty-five had had arthrodesis of the first metatarso-phalangeal joint and eighty-five had had Keller's operation. Footprints were made in order to assess the patterns of weight-bearing on the big toe and on the lesser metatarsal heads. After arthrodesis the big toe bore weight in 80 per cent compared with 40 per cent after Keller's operation. The ability to bear weight on the big toe is related to the presence of metatarsalgia and excessive weight bearing on the lesser metatarsal heads. These complications were seen more commonly after Keller's operation (particularly when more than one-third of the phalanx had been excised) than after arthrodesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 35-B, Issue 1 | Pages 70 - 71
1 Feb 1953
Cherry JC


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 189 - 195
1 Feb 2007
Levy JC Virani N Pupello D Frankle M

We report the use of the reverse shoulder prosthesis in the revision of a failed shoulder hemiarthroplasty in 19 shoulders in 18 patients (7 men, 11 women) with severe pain and loss of function. The primary procedure had been undertaken for glenohumeral arthritis associated with severe rotator cuff deficiency. Statistically significant improvements were seen in pain and functional outcome. After a mean follow-up of 44 months (24 to 89), mean forward flexion improved by 26.4° and mean abduction improved by 35°. There were six prosthesis-related complications in six shoulders (32%), five of which had severe bone loss of the glenoid, proximal humerus or both. Three shoulders (16%) had non-prosthesis related complications. The use of the reverse shoulder prosthesis provides improvement in pain and function for patients with failure of a hemiarthroplasty for glenohumeral arthritis and rotator cuff deficiency. However, high rates of complications were associated with glenoid and proximal humeral bone loss


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 565 - 571
1 May 2003
Jones S Hosalkar HS Hill RA Hartley J

We have treated seven children with relapsed infantile Blount’s disease by elevation of the hemiplateau using the Ilizarov frame. Three boys and four girls with a mean age of 10.5 years were reviewed at a mean of 29 months after surgery. All had improved considerably and were pleased with the results. The improvements in radiological measurements were statistically significant (p < 0.001). Three-dimensional CT reconstruction was useful for planning surgery. There were no major complications. The advantages of this technique are that in addition to elevation of the hemiplateau, rotational deformities and limb-length discrepancies may be addressed


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 411 - 418
1 Apr 2003
Ziran BH Smith WR Towers J Morgan SJ

Various techniques have been used for the fixation of the posterior pelvis, each with disadvantages specific to the technique. In this study, a new protocol involving the placement of posterior pelvic screws in the CT suite is described and evaluated. A total of 66 patients with unstable pelvic ring injuries was stabilised under local anaesthesia with sedation. The mean length of time for the procedure was 26 minutes per screw. There were no technical difficulties or misplaced screws and no cases of infection or nonunion. All patients stated that they would choose to have the CT scan procedure again rather than a procedure requiring general anaesthesia. The charges for the procedure were approximately £1840 ($2800) per operation. CT-guided placement of iliosacral screws is a safe, feasible, and cost-effective alternative to radiologically-guided placement in the operating theatre in selected patients


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 357 - 360
1 Mar 2009
Dalury DF Mason JB Murphy JA Adams MJ

Gender-specific total knee replacement has generated much interest recently. We reviewed 1970 Sigma knees implanted in 920 women and 592 men with a mean age of 69.7 years.

At a mean follow-up of 7.3 years (minimum, five years), we found minimal differences in the outcome between genders. At the final follow-up, men had a higher overall Knee Society score and more osteolysis (3.8% vs 1.1%). However, there were no significant differences between men and women in terms of complications or improvements in knee function, pain score or range of movement. The estimated ten-year survivorship was 97% in women and 98% in men (p = 0.96).

We concluded that there was little difference in outcome between the genders treated by a modern unisex design of total knee replacement in this large multicentre study.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 1001 - 1006
1 Jul 2013
Esteban J Alvarez-Alvarez B Blanco A Fernández-Roblas R Gadea I Garcia-Cañete J Sandoval E Valdazo M

We have designed a prospective study to evaluate the usefulness of prolonged incubation of cultures from sonicated orthopaedic implants. During the study period 124 implants from 113 patients were processed (22 osteosynthetic implants, 46 hip prostheses, 54 knee prostheses, and two shoulder prostheses). Of these, 70 patients had clinical infection; 32 had received antibiotics at least seven days before removal of the implant. A total of 54 patients had sonicated samples that produced positive cultures (including four patients without infection). All of them were positive in the first seven days of incubation. No differences were found regarding previous antibiotic treatment when analysing colony counts or days of incubation in the case of a positive result. In our experience, extending incubation of the samples to 14 days does not add more positive results for sonicated orthopaedic implants (hip and knee prosthesis and osteosynthesis implants) compared with a conventional seven-day incubation period.

Cite this article: Bone Joint J 2013;95-B:1001–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 915 - 918
1 Jul 2007
Hanratty BM Thompson NW Wilson RK Beverland DE

We have studied the concept of posterior condylar offset and the importance of its restoration on the maximum range of knee flexion after posterior-cruciate-ligament-retaining total knee replacement (TKR). We measured the difference in the posterior condylar offset before and one year after operation in 69 patients who had undergone a primary cruciate-sacrificing mobile bearing TKR by one surgeon using the same implant and a standardised operating technique. In all the patients true pre- and post-operative lateral radiographs had been taken. The mean pre- and post-operative posterior condylar offset was 25.9 mm (21 to 35) and 26.9 mm (21 to 34), respectively. The mean difference in posterior condylar offset was + 1 mm (−6 to +5). The mean pre-operative knee flexion was 111° (62° to 146°) and at one year postoperatively, it was 107° (51° to 137°). There was no statistical correlation between the change in knee flexion and the difference in the posterior condylar offset after TKR (Pearson correlation coefficient r = −0.06, p = 0.69)


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 566 - 570
1 May 2000
Anderson GA Thomas BP

Between June 1991 and May 1996 we carried out arthrodesis on 15 patients with flail or partially flail wrists using an AO/ASIF dynamic compression plate (DCP) without a bone graft. The wrist was approached through the second extensor compartment. The minimum follow-up was for 24 months with a mean of 34.2 months. All 15 wrists fused without major complications at a mean of 11.9 weeks. Stabilisation improved the function of the hand affected with paralysis and the appearance of the extensively paralysed upper limb with a flail hand. In the absence of bony abnormality fusion can be obtained with a DCP alone without the need for bone grafting