Advertisement for orthosearch.org.uk
Results 641 - 660 of 688
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1154 - 1157
1 Sep 2009
White SP John AW Jones SA

Between December 2004 and June 2006, 136 patients (156 total hip replacements), were sent from the waiting list of the Cardiff Vale NHS Trust to the NHS Treatment Centre, Weston-super-Mare, in an attempt to reduce the waiting time for total hip replacement. Because of concerns about their outcome, each patient was contacted and invited to attend a review appointment with a consultant specialising in hip and revision hip replacement.

A total of 98 patients (113 hips) were reviewed after a mean of 23 months (11 to 30). There were 104 cemented hips, seven hybrid and two cementless. An acetabular inclination of > 55° was seen in 18 (16%). Radiolucent lines around the acetabular component were seen in 76 (67%). The femoral component was in more than 4° of varus in 47 (42%). The medial floor had been breached in 13 (12%) and there was a leg-length discrepancy of more than 1 cm in ten (9%). There were three dislocations, one femoral fracture, one pulmonary embolus, one deep infection and two superficial wound infections.

To date, 13% (15 hips) have been revised and a further 4% (five hips) await revision, mostly for a painful loose acetabular component. The revision rate far exceeds the 0.5% five-year failure rate reported in the Swedish Registry for the components used. This initiative and the consequent need for correction of the problems created, has significantly increased the workload of our unit.


Bone & Joint Research
Vol. 2, Issue 2 | Pages 33 - 40
1 Feb 2013
Palmer AJR Thomas GER Pollard TCB Rombach I Taylor A Arden N Beard DJ Andrade AJ Carr AJ Glyn-Jones S

Objectives

The number of surgical procedures performed each year to treat femoroacetabular impingement (FAI) continues to rise. Although there is evidence that surgery can improve symptoms in the short-term, there is no evidence that it slows the development of osteoarthritis (OA). We performed a feasibility study to determine whether patient and surgeon opinion was permissive for a Randomised Controlled Trial (RCT) comparing operative with non-operative treatment for FAI.

Methods

Surgeon opinion was obtained using validated questionnaires at a Specialist Hip Meeting (n = 61, 30 of whom stated that they routinely performed FAI surgery) and patient opinion was obtained from clinical patients with a new diagnosis of FAI (n = 31).


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 185 - 189
1 Feb 2009
Pandit H Jenkins C Beard DJ Gallagher J Price AJ Dodd CAF Goodfellow JW Murray DW

We randomised 62 knees to receive either cemented or cementless versions of the Oxford unicompartmental knee replacement. The implants used in both arms of the study were similar, except that the cementless components were coated with porous titanium and hydroxyapatite. The tibial interfaces were studied with fluoroscopically-aligned radiographs.

At one year there was no difference in clinical outcome between the two groups. Narrow radiolucent lines were seen at the bone-implant interfaces in 75% of cemented tibial components. These were partial in 43%, and complete in 32%. In the cementless implants, partial radiolucencies were seen in 7% and complete radiolucencies in none. These differences are statistically significant (p < 0.0001) and imply satisfactory bone ingrowth into the cementless implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1130 - 1130
1 Aug 2007
COBB JP


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1025 - 1030
1 Aug 2009
Ollivere B Darrah C Barker T Nolan J Porteous MJ

The rate and mode of early failure in 463 Birmingham hip resurfacings in a two-centre, multisurgeon series were examined. Of the 463 patients two have died and three were lost to follow-up. The mean radiological and clinical follow-up was for 43 months (6 to 90).

We have revised 13 resurfacings (2.8%) including seven for pain, three for fracture, two for dislocation and another for sepsis. Of these, nine had macroscopic and histological evidence of metallosis. The survival at five years was 95.8% (95% confidence interval (CI) 94.1 to 96.8) for revision for all causes and 96.9% (95% CI 95.5 to 98.3) for metallosis.

The rate of metallosis related revision was 3.1% at five years. Risk factors for metallosis were female gender, a small femoral component, a high abduction angle and obesity. We do not advocate the use of the Birmingham Hip resurfacing procedure in patients with these risk factors.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 577 - 582
1 May 2009
Duncan WW Hubble MJW Howell JR Whitehouse SL Timperley AJ Gie GA

The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The stems were removed to gain a better exposure for acetabular revision, to alter version or leg length, or for component incompatibility.

We studied 136 hips in 134 patients and followed them up for a mean of eight years (5 to 15). A further revision was required in 35 hips (25.7%), for acetabular loosening in 26 (19.1%), sepsis in four, instability in three, femoral fracture in one and stem fracture in one. No femoral stem needed to be re-revised for aseptic loosening.

A cement-in-cement revision of the femoral stem is a reliable technique in the medium term. It also reduces the risk of perforation or fracture of the femoral shaft.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 241 - 248
1 Feb 2005
Pynsent PB Adams DJ Disney SP

The Oxford hip and knee scores are used to measure the outcome after primary total hip and knee replacement. We propose a new layout for the instrument in which patients are always asked about both limbs. In addition, we have defined an alternative scoring method which accounts for missing data. Over a period of 4.5 years, 4086 (1423 patients) and 5708 (1458 patients) questionnaires were completed for hips and knees, respectively. The hip score had a pre-operative median of 70.8 (interquartile range (IQR) 58.3 to 81.2) decreasing to 20.8 (IQR 10.4 to 35.4) after one year. The knee score had a pre-operative median of 68.8 (IQR 56.2 to 79.2) decreasing to 29.2 (IQR 14.6 to 45.8). There was no further significant change in either score after one year. As a result of the data analysis, we suggest that the score percentiles can be used as a standard for auditing patients before and after operation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 209 - 216
1 Feb 2010
Pollard TCB Villar RN Norton MR Fern ED Williams MR Murray DW Carr AJ

Femoroacetabular impingement causes pain in the hip in young adults and may predispose to the development of osteoarthritis. Genetic factors are important in the aetiology of osteoarthritis of the hip and may have a role in that of femoroacetabular impingement. We compared 96 siblings of 64 patients treated for primary impingement with a spouse control group of 77 individuals. All the subjects were screened clinically and radiologically using a standardised protocol for the presence of cam and pincer deformities and osteoarthritis.

The siblings of those patients with a cam deformity had a relative risk of 2.8 of having the same deformity (66 of 160 siblings hips versus 23 of 154 control hips, p < 0.00001). The siblings of those patients with a pincer deformity had a relative risk of 2.0 of having the same deformity (43 of 116 sibling hips versus 29 of 154 control hips, p = 0.001). Bilateral deformity occurred more often in the siblings (42 of 96 siblings versus 13 of 77 control subjects, relative risk 2.6, p = 0.0002). The prevalence of clinical features in those hips with abnormal morphology was also greater in the sibling group compared with the control group (41 of 109 sibling hips versus 7 of 46 control hips, relative risk 2.5, p = 0.007). In 11 sibling hips there was grade-2 osteoarthritis according to Kellgren and Lawrence versus none in the control group (p = 0.002).

Genetic influences are important in the aetiology of primary femoroacetabular impingement. This risk appears to be manifested through not only abnormal joint morphology, but also through other factors which may modulate progression of the disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1594 - 1600
1 Dec 2009
Khan A Bunker TD Kitson JB

There are no long-term published results on the survival of a third-generation cemented total shoulder replacement. We describe a clinical and radiological study of the Aequalis total shoulder replacement for a minimum of ten years. Between September 1996 and May 1998, 39 consecutive patients underwent a primary cemented total shoulder replacement using this prosthesis. Data were collected prospectively on all patients each year, for a minimum of ten years, or until death or failure of the prosthesis. At a follow-up of at least ten years, 12 patients had died with the prosthesis intact and two had emigrated, leaving 25 available for clinical review. Of these, 13 had rheumatoid arthritis and 12 osteoarthritis. One refused radiological review leaving 24 with fresh radiographs.

Survivorship at ten years was 100% for the humeral component and 92% for the glenoid component. The incidence of lucent lines was low. No humeral component was thought to be at risk and only two glenoid components. The osteoarthritic group gained a mean 65° in forward flexion and their Constant score improved by a mean 41.4 points (13 to 55). The rheumatoid group gained a mean of 24° in flexion and their Constant score improved by 29.4 points. This difference may have been due to failure of the rotator cuff in 75% of the patients with rheumatoid arthritis.

Thus a third-generation total shoulder replacement gives an excellent result in patients with osteoarthritis and an intact rotator cuff. Patients with rheumatoid arthritis have a 75% risk of failure of the rotator cuff at ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1180 - 1186
1 Sep 2012
Murray DW Grammatopoulos G Pandit H Gundle R Gill HS McLardy-Smith P

Recent events have highlighted the importance of implant design for survival and wear-related complications following metal-on-metal hip resurfacing arthroplasty. The mid-term survival of the most widely used implant, the Birmingham Hip Resurfacing (BHR), has been described by its designers. The aim of this study was to report the ten-year survival and patient-reported functional outcome of the BHR from an independent centre.

In this cohort of 554 patients (646 BHRs) with a mean age of 51.9 years (16.5 to 81.5) followed for a mean of eight years (1 to 12), the survival and patient-reported functional outcome depended on gender and the size of the implant. In female hips (n = 267) the ten-year survival was 74% (95% confidence interval (CI) 83 to 91), the ten-year revision rate for pseudotumour was 7%, the mean Oxford hip score (OHS) was 43 (sd 8) and the mean UCLA activity score was 6.4 (sd 2). In male hips (n = 379) the ten-year survival was 95% (95% CI 92.0 to 97.4), the ten-year revision rate for pseudotumour was 1.7%, the mean OHS was 45 (sd 6) and the mean UCLA score was 7.6 (sd 2). In the most demanding subgroup, comprising male patients aged < 50 years treated for primary osteoarthritis, the survival was 99% (95% CI 97 to 100).

This study supports the ongoing use of resurfacing in young active men, who are a subgroup of patients who tend to have problems with conventional THR. In contrast, the results in women have been poor and we do not recommend metal-on-metal resurfacing in women. Continuous follow-up is recommended because of the increasing incidence of pseudotumour with the passage of time.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1120 - 1125
1 Aug 2012
Alazzawi S Bardakos NV Hadfield SG Butt U Beer ZH Field RE

Using general practitioner records and hospital notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications gathered from a self-completed questionnaire after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with a mean age of 71.8 years (34 to 93). A total of 319 reported complications (79.4%; 95% confidence interval 75.4 to 83.3) were confirmed to be correct. High rates of correct reporting were demonstrated for infection (94.5%) and the need for further surgery (100%), whereas the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism, myocardial infarction and stroke were lower (75% to 84.2%). Dislocation, peri-prosthetic fractures and nerve palsy had modest rates of correct reporting (36% to 57.1%). More patients who had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013).

Despite these variations, it appears that post-operative complications may form part of a larger patient-reported outcome programme after elective joint replacement surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1285 - 1286
1 Sep 2011
Baker JF Vioreanu MH Khan HA

A variety of materials were used for early hip prostheses. The introduction of Vitallium by Smith-Petersen represented a further advance in this surgical field. We present the longest known follow-up of a Smith-Petersen Vitallium mould arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1116 - 1117
1 Aug 2006
SAWEERES ESB


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 603 - 608
1 May 2012
Vasukutty NL Middleton RG Matthews EC Young PS Uzoigwe CE Minhas THA

We present our experience with a double-mobility acetabular component in 155 consecutive revision total hip replacements in 149 patients undertaken between 2005 and 2009, with particular emphasis on the incidence of further dislocation. The mean age of the patients was 77 years (42 to 89) with 59 males and 90 females. In all, five patients died and seven were lost to follow-up. Indications for revision were aseptic loosening in 113 hips, recurrent instability in 29, peri-prosthetic fracture in 11 and sepsis in two. The mean follow-up was 42 months (18 to 68). Three hips (2%) in three patients dislocated within six weeks of surgery; one of these dislocated again after one year. All three were managed successfully with closed reduction. Two of the three dislocations occurred in patients who had undergone revision for recurrent dislocation. All three were found at revision to have abductor deficiency. There were no dislocations in those revised for either aseptic loosening or sepsis.

These results demonstrate a good mid-term outcome for this component. In the 29 patients revised for instability, only two had a further dislocation, both of which were managed by closed reduction.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1581 - 1585
1 Dec 2007
McConway J O’Brien S Doran E Archbold P Beverland D

Between April 1992 and July 2005, 310 posterior lip augmentation devices were used for the treatment of recurrent dislocation of the hip in 307 patients who had received primary total hip replacements (THRs) using Charnley/Charnley Elite components with a cemented acetabulum. The mean number of dislocations before stabilisation with the device was five (1 to 16) with a mean time to this intervention from the first dislocation of 3.8 years (0 days to 22.5 years). The mean age of the patients at this reconstruction was 75.4 years (39 to 96).

A retrospective clinical and radiological review was carried out at a mean follow-up of six years and nine months (4.4 months to 13 years and 7 months). Of the 307 patients, 53 had died at the time of the latest review, with a functioning THR and with the posterior lip augmentation device in situ. There were four revisions (1.3%), one for pain, two for deep infection and one for loosening of the acetabular component. Radiolucent lines around the acetabular component increased in only six cases after insertion of the device which was successful in eliminating instability in 302 patients, with only five further dislocations (1.6%) occurring after its insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 642 - 647
1 May 2012
Mullaji A Lingaraju AP Shetty GM

We retrospectively reviewed the records of 1150 computer-assisted total knee replacements and analysed the clinical and radiological outcomes of 45 knees that had arthritis with a pre-operative recurvatum deformity. The mean pre-operative hyperextension deformity of 11° (6° to 15°), as measured by navigation at the start of the operation, improved to a mean flexion deformity of 3.1° (0° to 7°) post-operatively. A total of 41 knees (91%) were managed using inserts ≤ 12.5 mm thick, and none had mediolateral laxity > 2 mm from a mechanical axis of 0° at the end of the surgery. At a mean follow-up of 26.4 months (13 to 48) there was significant improvement in the mean Knee Society, Oxford knee and Western Ontario and McMaster Universities Osteoarthritis Index scores compared with the pre-operative values. The mean knee flexion improved from 105° (80° to 125°) pre-operatively to 131° (120° to 145°), and none of the limbs had recurrent recurvatum.

These early results show that total knee replacement using computer navigation and an algorithmic approach for arthritic knees with a recurvatum deformity can give excellent radiological and functional outcomes without recurrent deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 180 - 185
1 Feb 2008
Utting MR Mulford JS Eldridge JDJ

Trochlear dysplasia is a developmental condition characterised by an abnormally flat or dome-shaped trochlea and is an important contributory factor to patellofemoral instability and recurrent dislocation. We studied prospectively a series of 54 consecutive patients (59 knees) with patellofemoral instability secondary to trochlear dysplasia, who were treated by a trochleoplasty by a single surgeon between June 2002 and June 2007.

Pre- and post-operative scores were assessed by the patients and a satisfaction questionnaire was completed.

Of the 54 patients (59 knees) in the series, 39 (44 knees) were female and 15 (15 knees) were male. Their mean age at surgery was 21 years and 6 months (14 years 4 months to 33 years 11 months). In 40 patients (42 knees) the mean follow-up was for 24 months (12 to 58). One patient was unable to attend for follow-up. An analysis of the results of those patients followed up for at least 12 months showed a statistically significant improvement in outcome (p < 0.001 for all scores). Overall, 50 patients (92.6%) were satisfied with the outcome of their procedure.

The early results of trochleoplasty are encouraging in this challenging group of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 569 - 570
1 May 2011
Wylde V Blom AW

This editorial considers the shortcomings of assessing outcome after joint replacement only by the survival of the implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1296 - 1299
1 Oct 2011
Lang JE Mannava S Floyd AJ Goddard MS Smith BP Mofidi A M. Seyler T Jinnah RH

Robots have been used in surgery since the late 1980s. Orthopaedic surgery began to incorporate robotic technology in 1992, with the introduction of ROBODOC, for the planning and performance of total hip replacement. The use of robotic systems has subsequently increased, with promising short-term radiological outcomes when compared with traditional orthopaedic procedures. Robotic systems can be classified into two categories: autonomous and haptic (or surgeon-guided). Passive surgery systems, which represent a third type of technology, have also been adopted recently by orthopaedic surgeons.

While autonomous systems have fallen out of favour, tactile systems with technological improvements have become widely used. Specifically, the use of tactile and passive robotic systems in unicompartmental knee replacement (UKR) has addressed some of the historical mechanisms of failure of non-robotic UKR. These systems assist with increasing the accuracy of the alignment of the components and produce more consistent ligament balance. Short-term improvements in clinical and radiological outcomes have increased the popularity of robot-assisted UKR.

Robot-assisted orthopaedic surgery has the potential for improving surgical outcomes. We discuss the different types of robotic systems available for use in orthopaedics and consider the indication, contraindications and limitations of these technologies.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 951 - 954
1 Jul 2006
Fenton PA Suvarna SK Currey JD Hamer AJ

Systemic mastocytosis is a rare condition that often involves the bone marrow. We report the case of a patient with systemic mastocytosis who underwent total hip replacement. Technical difficulties encountered during the procedure included a narrow medullary canal and abnormally hard bone, later confirmed by laboratory measurements. Follow-up at five years showed a good clinical and radiological outcome.