Although success has been achieved with implantation of
We investigated the rates of expression of
Of tumours arising in otherwise normal
The long-term results of grafting with hydroxyapatite granules for acetabular deficiency in revision total hip replacement are not well known. We have evaluated the results of revision using a modular cup with hydroxyapatite grafting for Paprosky type 2 and 3 acetabular defects at a minimum of ten years’ follow-up. We retrospectively reviewed 49 acetabular revisions at a mean of 135 months (120 to 178). There was one type 2B, ten 2C, 28 3A and ten 3B hips. With loosening as the endpoint, the survival rate was 74.2% (95% confidence interval 58.3 to 90.1). Radiologically, four of the type 3A hips (14%) and six of the type 3B hips (60%) showed aseptic loosening with collapse of the hydroxyapatite layer, whereas no loosening occurred in type 2 hips. There was consolidation of the hydroxyapatite layer in 33 hips (66%). Loosening was detected in nine of 29 hips (31%) without cement and in one of 20 hips (5%) with cement (p = 0.03, Fisher’s exact probability test). The linear wear and annual wear rate did not correlate with loosening. These results suggest that the long-term results of hydroxyapatite grafting with cement for type 2 and 3A hips are encouraging.
We have used dual-energy X-ray absorptiometry to measure
The clinical records, radiographs and histopathological material of all forty-one patients recorded as suffering from fibrosarcoma of
We compared the mechanical properties of carbon fibre composite
In order to improve the fixation of the stem in primary Charnley low-friction arthroplasty, the medullary canal was routinely closed off with a cancellous
Ossification of the ligamentum flavum and secondary spinal-cord compression were produced experimentally in mice by implanting
We report a prospective study of the use of intramedullary
Experimental injuries of cartilage and
We have studied the effect of hydroxyapatite (HA) coating in 15 ovariectomised and 15 normal rats which had had a sham procedure. Twenty-four weeks after operation, HA-coated implants were inserted into the intramedullary canal of the right femur and uncoated implants into the left femur. The prostheses were removed four weeks after implantation. Twelve specimens in each group had mechanical push-out tests. Sagittal sections of the other three were evaluated by SEM. The
1. The humoral immune response of rats against sheep iliac bone grafts has been examined. 2. Fresh, marrow-containing grafts elicited a brisk and sustained antibody response. Attempts to wash out the marrow were not uniformly successful in removing cellular antigens from the grafts. 3. Decalcifying and freezing bone grafts at —20 degrees Celsius do not impair immunogenicity to any significant extent. Immunogenicity was found to be reduced in grafts subjected to freeze-drying. 4. Deproteinised Oswestry bone grafts and Kiel grafts gave rise to antibody production in a few recipients, and in the case of the former this response did not occur until after six or seven weeks from grafting. 5. The highest degree of osteogenesis in composite