Alumina–alumina bearings are among the most resistant
to wear in total hip replacement. Examination of their surfaces
is one way of comparing damage caused by wear of hip joints simulated in
vitro to that seen in explanted bearings. The aim of this
study was to determine whether second-generation ceramic bearings
exhibited a better pattern of wear than those reported in the literature
for first-generation bearings. We considered both macro- and microscopic
findings. We found that long-term alumina wear in association with a loose
acetabular component could be categorised into three groups. Of
20 specimens, four had ‘low wear’, eight ‘crescent wear’ and eight
‘severe wear’, which was characterised by a change in the physical
shape of the bearing and a loss of volume. This suggests that the
wear in alumina–alumina bearings in association with a loose acetabular
component may be variable in pattern, and may explain, in part,
why the wear of a ceramic
Current guidelines recommend surgery within 48 hours among patients presenting with hip fractures; however, optimal surgical timing for patients on oral anticoagulants (OACs) remains unclear. Individual studies are limited by small sample sizes and heterogeneous outcomes. The aim of this study was to conduct a systematic review and meta-analysis to summarize the effect of pre-injury OACs on time-to-surgery (TTS) and all-cause mortality among older adults with hip fracture treated surgically. We searched MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL) from inception to 14 October 2019 to identify studies directly comparing outcomes among hip fracture patients receiving direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs) prior to hospital admission to hip fracture patients not on OACs. Random effects meta-analyses were used to pool all outcomes (TTS, in-hospital mortality, and 30-day mortality).Aims
Methods
The optimum clearance between the bearing surfaces of hip arthroplasties is unknown. Theoretically, to minimize wear, it is understood that clearances must be low enough to maintain optimal contact pressure and fluid film lubrication, while being large enough to allow lubricant recovery and reduce contact patch size. This study aimed to identify the relationship between diametrical clearance and volumetric wear, through the analysis of retrieved components. A total of 81 metal-on-metal Pinnacle hips paired with 12/14 stems were included in this study. Geometrical analysis was performed on each component, using coordinate and roundness measuring machines. The relationship between their as-manufactured diametrical clearance and volumetric wear was investigated. The Mann-Whitney U test and unpaired Aims
Methods
We analysed 54 alumina ceramic-on-ceramic bearings
from total hip replacements retrieved at one centre after a mean
duration of 3.5 years (0.2 to 10.6) in situ. These
implants were obtained from 54 patients (16 men and 38 women) with
a mean age of 67 years (33 to 88) who underwent revision for a variety
of reasons. Posterior edge loading was found in the majority of
these retrievals (32 out of 54). Anterosuperior edge loading occurred
less often but produced a higher rate of wear. Stripe wear on the
femoral
Guided growth has been used to treat coxa valga for cerebral palsy (CP) children. However, there has been no study on the optimal position of screw application. In this paper we have investigated the influence of screw position on the outcomes of guided growth. We retrospectively analyzed 61 hips in 32 CP children who underwent proximal femoral hemi epiphysiodesis between July 2012 and September 2017. The hips were divided into two groups according to the transphyseal position of the screw in the coronal plane: across medial quarter (Group 1) or middle quarter (Group 2) of the medial half of the physis. We compared pre- and postoperative radiographs in head-shaft angle (HSA), Reimer’s migration percentage (MP), acetabular index (AI), and femoral anteversion angle (FAVA), as well as incidences of the physis growing-off the screw within two years. Linear and Cox regression analysis were conducted to identify factors related to HSA correction and risk of the physis growing-off the screw.Aims
Methods
The aim of this study is to test the hypothesis that three grades of sagittal compensation for standing posture (normal, compensated, and decompensated) correlate with health-related quality of life measurements (HRQOL). A total of 50 healthy volunteers (normal), 100 patients with single-level lumbar degenerative spondylolisthesis (LDS), and 70 patients with adult to elderly spinal deformity (deformity) were enrolled. Following collection of demographic data and HRQOL measured by the Scoliosis Research Society-22r (SRS-22r), radiological measurement by the biplanar slot-scanning full body stereoradiography (EOS) system was performed simultaneously with force-plate measurements to obtain whole body sagittal alignment parameters. These parameters included the offset between the centre of the acoustic meatus and the gravity line (CAM-GL), saggital vertical axis (SVA), T1 pelvic angle (TPA), McGregor slope, C2-7 lordosis, thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), PI-LL, sacral slope (SS), pelvic tilt (PT), and knee flexion. Whole spine MRI examination was also performed. Cluster analysis of the SRS-22r scores in the pooled data was performed to classify the subjects into three groups according to the HRQOL, and alignment parameters were then compared among the three cluster groups.Aims
Methods
1. The anatomy of the forefoot in hallux valgus is compared with the normal, with a review of the literature and descriptions of anatomical preparations, observations at operation and radiographs. 2. The early and essential lesions are stretching of the ligaments on the medial side of the metatarso-phalangeal joint that attach the medial sesamoid and basal phalanx to the metatarsal, and erosion of the ridge that separates the grooves for the sesamoids on the metatarsal
Latissimus dorsi tendon transfer (LDTT) is technically
challenging. In order to clarify the local structural anatomy, we undertook
a morphometric study using six complete cadavers (12 shoulders).
Measurements were made from the tendon to the nearby neurovascular
structures with the arm in two positions: flexed and internally
rotated, and adducted in neutral rotation. The tendon was then transferred
and measurements were taken from the edge of the tendon to a reference
point on the humeral
To devise a method to quantify and optimize tightness when inserting cortical screws, based on bone characterization and screw geometry. Cortical human cadaveric diaphyseal tibiae screw holes (n = 20) underwent destructive testing to firstly establish the relationship between cortical thickness and experimental stripping torque (Tstr), and secondly to calibrate an equation to predict Tstr. Using the equation’s predictions, 3.5 mm screws were inserted (n = 66) to targeted torques representing 40% to 100% of Tstr, with recording of compression generated during tightening. Once the target torque had been achieved, immediate pullout testing was performed.Aims
Methods
We present a case of early retrieval of an Oxinium femoral head and corresponding polyethylene liner where there was significant surface damage to the
Noise generation has been reported with ceramic-on-ceramic
articulations in total hip replacement (THR). This study evaluated
208 consecutive Delta Motion THRs at a mean follow-up of 21 months
(12 to 35). There were 141 women and 67 men with a mean age of 59
years (22 to 84). Patients were reviewed clinically and radiologically,
and the incidence of noise was determined using a newly described
assessment method. Noise production was examined against range of
movement, ligamentous laxity, patient-reported outcome scores, activity
level and orientation of the acetabular component. There were 143
silent hips (69%), 22 (11%) with noises other than squeaking, 17
(8%) with unreproducible squeaking and 26 (13%) with reproducible
squeaking. Hips with reproducible squeaking had a greater mean range
of movement (p <
0.001) and mean ligament laxity (p = 0.004), smaller
median
The gluteus minimus (GMin) and gluteus medius (GMed) have unique structural and functional segments that may be affected to varying degrees, by end-stage osteoarthritis (OA) and normal ageing. We used data from patients with end-stage OA and matched healthy controls to 1) quantify the atrophy of the GMin and GMed in the two groups and 2) describe the distinct patterns of the fatty infiltration in the different segments of the GMin and GMed in the two groups. A total of 39 patients with end-stage OA and 12 age- and sex frequency-matched healthy controls were prospectively enrolled in the study. Fatty infiltration within the different segments of the GMin and the GMed was assessed on MRI according to the semiquantitative classification system of Goutallier and normalized cross-sectional areas were measured.Aims
Methods
Osteolysis remains a common reason for revision
after total hip arthroplasty (THA). For osteolysis associated with loose
cups, revision is indicated. For osteolysis around a well-fixed
cup, the decision is more controversial. The data available data
support retention of the cupwith lesional treatment, working through
screw holes and access channels for debridement and grafting. The
choice of graft material to fill defects, if any, remains controversial. Several
studies demonstrate good survivorship with cup retention strategies.
Complete revision allows more complete debridement of the lesion
and better graft fill, and allows implantation of a modern cup,
typically with a full line of liners and bearing surfaces available.
Additionally, revision allows fine tuning of the orientation of
the cup, which may be advantageous for optimising hip stability.
The author prefers to retain a well-fixed cup if it meets the following
criteria: it is well-fixed to intra-operative testing, it is well-positioned,
it is of sufficient size to allow insertion of a new liner with
a reasonable
Local recurrence remains a challenging and common problem following curettage and joint-sparing surgery for giant cell tumour of bone (GCTB). We previously reported a 15% local recurrence rate at a median follow-up of 30 months in 20 patients with high-risk GCTB treated with neoadjuvant Denosumab. The aim of this study was to determine if this initial favourable outcome following the use of Denosumab was maintained with longer follow-up. Patients with GCTB of the limb considered high-risk for unsuccessful joint salvage, due to minimal periarticular and subchondral bone, large soft tissue mass, or pathological fracture, were treated with Denosumab followed by extended intralesional curettage with the goal of preserving the joint surface. Patients were followed for local recurrence, metastasis, and secondary sarcoma.Aims
Methods
Fibrinolysis plays a key transition step from haematoma formation to angiogenesis and fracture healing. Low-magnitude high-frequency vibration (LMHFV) is a non-invasive biophysical modality proven to enhance fibrinolytic factors. This study investigates the effect of LMHFV on fibrinolysis in a clinically relevant animal model to accelerate osteoporotic fracture healing. A total of 144 rats were randomized to four groups: sham control; sham and LMHFV; ovariectomized (OVX); and ovariectomized and LMHFV (OVX-VT). Fibrinolytic potential was evaluated by quantifying fibrin, tissue plasminogen activator (tPA), and plasminogen activator inhibitor-1 (PAI-1) along with healing outcomes at three days, one week, two weeks, and six weeks post-fracture.Aims
Methods
Despite recent advances in arthroscopic rotator cuff repair, re-tear rates remain high. New methods to improve healing rates following rotator cuff repair must be sought. Our primary objective was to determine if adjunctive bone marrow stimulation with channelling five to seven days prior to arthroscopic cuff repair would lead to higher Western Ontario Rotator Cuff (WORC) scores at 24 months postoperatively compared with no channelling. A prospective, randomized controlled trial was conducted in patients undergoing arthroscopic rotator cuff repair. Patients were randomized to receive either a percutaneous bone channelling of the rotator cuff footprint or a sham procedure under ultrasound guidance five to seven days prior to index surgery. Outcome measures included the WORC, American Shoulder and Elbow Surgeons (ASES), and Constant scores, strength, ultrasound-determined healing rates, and adverse events.Aims
Methods
There are few reports of the surgical treatment for late stage Freiburg’s disease with flattening of the metatarsal
Surgical treatment of hip fracture is challenging; the bone is porotic and fixation failure can be catastrophic. Novel implants are available which may yield superior clinical outcomes. This study compared the clinical effectiveness of the novel X-Bolt Hip System (XHS) with the sliding hip screw (SHS) for the treatment of fragility hip fractures. We conducted a multicentre, superiority, randomized controlled trial. Patients aged 60 years and older with a trochanteric hip fracture were recruited in ten acute UK NHS hospitals. Participants were randomly allocated to fixation of their fracture with XHS or SHS. A total of 1,128 participants were randomized with 564 participants allocated to each group. Participants and outcome assessors were blind to treatment allocation. The primary outcome was the EuroQol five-dimension five-level health status (EQ-5D-5L) utility at four months. The minimum clinically important difference in utility was pre-specified at 0.075. Secondary outcomes were EQ-5D-5L utility at 12 months, mortality, residential status, mobility, revision surgery, and radiological measures.Aims
Methods
Femoroacetabular impingement (FAI) is commonly
associated with early hip arthritis. We reviewed our series of 1300
hip resurfacing procedures. More than 90% of our male patients,
with an average age of 53 years, had cam impingement lesions. In
this condition, there are anterior femoral neck osteophytes, and
a retroverted femoral head on a normally anteverted neck. It is
postulated that FAI results in collision of the anterior neck of
the femur against the rim of the acetabulum, causing damage to the
acetabular labrum and articular cartilage, resulting in osteoarthritis.
Early treatment of FAI involves arthroscopic or open removal of
bone from the anterior femoral neck, as well as repair or removal
of labral tears. However, once osteoarthritis has developed, hip
replacement or hip resurfacing is indicated. Hip resurfacing can
re-orient the