Advertisement for orthosearch.org.uk
Results 681 - 700 of 765
Results per page:
Bone & Joint 360
Vol. 2, Issue 4 | Pages 8 - 10
1 Aug 2013

The August 2013 Hip & Pelvis Roundup360 looks at: are we getting it right first time?; tantalum augments in revision hip surgery; lower wear in dual mobility?; changing faces changes outcomes; synovial fluid aspiration in MOM hips; taper disease: the new epidemic of hip surgery; the super-obese and THR; and whether well fixed stems can remain in infected hips


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1289 - 1295
1 Oct 2011
Yoon RS Hwang JS Beebe KS

For over a decade, bisphosphonate administration has evolved and become the cornerstone of the prevention and treatment of fragility fractures. Millions of post-menopausal women have relied on, and continue to depend on, the long-acting, bone density-maintaining pharmaceutical drug to prevent low-energy fractures. In return, we have seen the number of fragility fractures decrease, along with associated costs and emotional benefits. However, with any drug, there are often concerns with side effects and complications, and this unique drug class is seeing one such complication in atypical subtrochanteric femoral fracture, counterproductive to that which it was designed to prevent. This has created concern over long-term bisphosphonate administration and its potential link to these atypical fractures. There is controversial evidence surrounding such a definitive link, and no protocol for managing these fractures.

This review offers the latest information regarding this rare but increasingly controversial adverse effect and its potential connection to one of the most successful forms of treatment that is available for the management of fragility fractures.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 110 - 115
1 Jan 2010
Bosma E de Jongh MAC Verhofstad MHJ

This retrospective cohort study was conducted to investigate whether operative treatment of patients with a pertrochanteric femoral fracture outside working hours is associated with an increased risk of complications and higher mortality. During the study period 165 patients were operated on outside working hours and 123 were operated on during working hours (08.00 to 17.00). There was no difference in the rate of early complications (outside working hours 33% versus working hours 33%, p = 0.91) or total complications during follow-up (outside working hours 40% versus working hours 41%, p = 0.91). Both in-hospital mortality (outside working hours 12% versus working hours 11%, p = 0.97) and mortality after one year (outside working hours 29% versus working hours 27%, p = 0.67) were comparable. Adjustment for possible confounders by multivariate logistic regression analysis revealed no increased risk of complications when patients were operated on outside working hours.

On the basis of these data, there is no medical reason to postpone operative reduction and fixation in patients with a proximal femoral fracture until working hours.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 393 - 398
1 Mar 2011
Findlay JM Keogh MJ Boulton C Forward DP Moran CG

We performed a retrospective study of a departmental database to assess the efficacy of a new model of orthopaedic care on the outcome of patients with a fracture of the proximal femur. All 1578 patients admitted to a university teaching hospital with a fracture of the proximal femur between December 2007 and December 2009 were included. The allocation of Foundation doctors years 1 and 2 was restructured from individual teams covering several wards to pairs covering individual wards. No alterations were made in the numbers of doctors, their hours, out-of-hours cover, or any other aspect of standard patient care. Outcome measures comprised 30-day mortality and cause, complications and length of stay. Mortality was reduced from 11.7% to 7.6% (p = 0.007, Cox’s regression analysis); adjusted odds ratio was 1.559 (95% confidence interval 1.128 to 2.156). Reductions were seen in Clostridium difficile colitis (p = 0.017), deep wound infection (p = 0.043) and gastrointestinal haemorrhage (p = 0.033). There were no differences in any patient risk factors (except the prevalence of chronic obstructive pulmonary disease), cause of death and length of stay before and after intervention. The underlying mechanisms are unclear, but may include improved efficiency and medical contact time.

These findings may have implications for all specialties caring for patients on several wards, and we believe they justify a prospective trial to further assess this effect.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 157 - 166
1 Nov 2012
Rosenberg AG Berend ME Berry DJ Della Valle CJ MacDonald SJ Minas T

This conversation represents an attempt by several arthroplasty surgeons to critique several abstracts presented over the last year as well as to use them as a jumping off point for trying to figure out where they fit in into our current understanding of multiple issues in modern hip and knee arthroplasty.


Bone & Joint 360
Vol. 2, Issue 2 | Pages 10 - 12
1 Apr 2013

The April 2013 Hip & Pelvis Roundup360 looks at: hip cartilage and magnets; labral repair or resection; who benefits from injection; rotational osteotomy for osteonecrosis; whether ceramic implants risk fracture; dual articulation; and hydroxyapatite.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1669 - 1677
1 Dec 2010
Thakar C Alsousou J Hamilton TW Willett K

We evaluated the cost and consequences of proximal femoral fractures requiring further surgery because of complications. The data were collected prospectively in a standard manner from all patients with a proximal femoral fracture presenting to the trauma unit at the John Radcliffe Hospital over a five-year period. The total cost of treatment for each patient was calculated by separating it into its various components. The risk factors for the complications that arose, the location of their discharge and the mortality rates for these patients were compared to those of a matched control group. There were 2360 proximal femoral fractures in 2257 patients, of which 144 (6.1%) required further surgery. The mean cost of treatment in patients with complications was £18 709 (£2606.30 to £60.827.10), compared with £8610 (£918.54 to £45 601.30) for uncomplicated cases (p < 0.01), with a mean length of stay of 62.8 (44.5 to 79.3) and 32.7 (23.8 to 35.0) days, respectively. The probability of mortality after one month in these cases was significantly higher than in the control group, with a mean survival of 209 days, compared with 496 days for the controls. Patients with complications were statistically less likely to return to their own home (p < 0.01).

Greater awareness and understanding are required to minimise the complications of proximal femoral fractures and consequently their cost.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 72 - 77
1 Jan 2008
Sharma S Fraser M Lovell F Reece A McLellan AR

Osteoporosis and fragility fractures in men constitute a considerable burden in healthcare. We have reviewed 2035 men aged over 50 years with 2142 fractures to clarify the epidemiology of these injuries and their underlying risk factors. The prevalence of osteoporosis ranged between 17.5% in fractures of the ankle and 57.8% in those of the hip. The main risk factors associated with osteoporosis were smoking (47.4%), alcohol excess (36.2%), body mass index < 21 (12.8%) and a family history of osteoporosis (8.4%). Immobility, smoking, self-reported alcohol excess, a low body mass index, age ≥72 and loss in height were significantly more common among men with fractures of the hip than in those with fractures elsewhere.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 96 - 101
1 Jan 2011
Meek RMD Norwood T Smith R Brenkel IJ Howie CR

Peri-prosthetic fracture after joint replacement in the lower limb is associated with significant morbidity. The primary aim of this study was to investigate the incidence of peri-prosthetic fracture after total hip replacement (THR) and total knee replacement (TKR) over a ten-year period using a population-based linked dataset. Between 1 April 1997 and 31 March 2008, 52 136 primary THRs, 8726 revision THRs, 44 511 primary TKRs, and 3222 revision TKRs were performed. Five years post-operatively, the rate of fracture was 0.9% after primary THR, 4.2% after revision THR, 0.6% after primary TKR and 1.7% after revision TKR. Comparison of survival analysis for all primary and revision arthroplasties showed peri-prosthetic fractures were more likely in females, patients aged > 70 and after revision arthroplasty. Female patients aged > 70 should be warned of a significantly increased risk of peri-prosthetic fracture after hip or knee replacement. The use of adjuvant medical treatment to reduce the effect of peri-prosthetic osteoporosis may be a direction of research for these patients


Bone & Joint Research
Vol. 2, Issue 3 | Pages 58 - 65
1 Mar 2013
Johnson R Jameson SS Sanders RD Sargant NJ Muller SD Meek RMD Reed MR

Objectives

To review the current best surgical practice and detail a multi-disciplinary approach that could further reduce joint replacement infection.

Methods

Review of relevant literature indexed in PubMed.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 12 | Pages 1595 - 1597
1 Dec 2012
Panesar SS Shaerf DA Mann BS Malik AK

We summarise and highlight the safety concerns within the field of trauma and orthopaedic surgery with particular emphasis placed on current controversies and reforms within the United Kingdom National Health Service.


Bone & Joint 360
Vol. 1, Issue 4 | Pages 34 - 34
1 Aug 2012
Timperley J


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 3 - 7
1 Nov 2012
Barrack RL

Venous thromboembolism (VTE) remains an immediate threat to patients following total hip and knee replacement. While there is a strong consensus that steps should be taken to minimise the risk to patients by utilising some forms of prophylaxis for the vast majority of patients, the methods utilised have been extremely variable. Clinical practice guidelines (CPGs) have been published by various professional organisations for over 25 years to provide recommendations to standardise VTE prophylaxis. Historically, these recommendations have varied widely depending in underlying assumptions, goals, and methodology of the various groups. This effort has previously been exemplified by the American College of Chest Physicians (ACCP) and the American Academy of Orthopaedic Surgeons (AAOS). The former group of medical specialists targeted minimising venographically proven deep vein thrombosis (DVT) (the vast majority of which are asymptomatic) as their primary goal prior to 2012. The latter group of surgeons targeted minimising symptomatic VTE. As a result prior to 2012, the recommendations of the two groups were widely divergent. In the past year, both groups have reassessed the current literature with the principal goals of minimising symptomatic VTE events and bleeding complications. As a result, for the first time the CPGs of these two major subspecialty organisations are in close agreement.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 294 - 303
1 Mar 2009
Lindner T Kanakaris NK Marx B Cockbain A Kontakis G Giannoudis PV

Failure of fixation is a common problem in the treatment of osteoporotic fractures around the hip. The reinforcement of bone stock or of fixation of the implant may be a solution. Our study assesses the existing evidence for the use of bone substitutes in the management of these fractures in osteoporotic patients. Relevant publications were retrieved through Medline research and further scrutinised. Of 411 studies identified, 22 met the inclusion criteria, comprising 12 experimental and ten clinical reports. The clinical studies were evaluated with regard to their level of evidence. Only four were prospective and randomised.

Polymethylmethacrylate and calcium-phosphate cements increased the primary stability of the implant-bone construct in all experimental and clinical studies, although there was considerable variation in the design of the studies. In randomised, controlled studies, augmentation of intracapsular fractures of the neck of the femur with calcium-phosphate cement was associated with poor long-term results. There was a lack of data on the long-term outcome for trochanteric fractures. Because there were only a few, randomised, controlled studies, there is currently poor evidence for the use of bone cement in the treatment of fractures of the hip.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 310 - 314
1 Nov 2012
Griffin XL Achten J Parsons N Boardman F Griffiths F Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. The National Hip Fracture Audit currently provides a framework for service evaluation. This evaluation is based upon the assessment of process rather than assessment of patient-centred outcome and therefore it fails to provide meaningful data regarding the clinical effectiveness of treatments. This study aims to capture data from the cohort of patients who present with a fracture of the proximal femur at a single United Kingdom Major Trauma Centre. Patient-centred outcomes will be recorded and provide a baseline cohort within which to test the clinical effectiveness of experimental interventions.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 406 - 412
1 Mar 2010
Leonardsson O Sernbo I Carlsson Å åkesson K Rogmark C

In a series of 450 patients over 70 years of age with displaced fractures of the femoral neck sustained between 1995 and 1997 treatment was randomised either to internal fixation or replacement. Depending on age and level of activity the latter was either a total hip replacement or a hemiarthroplasty. Patients who were confused or bed-ridden were excluded, as were those with rheumatoid arthritis. At ten years there were 99 failures (45.6%) after internal fixation compared with 17 (8.8%) after replacement. The rate of mortality was high at 75% at ten years, and was the same in both groups at all times. Patient-reported pain and function were similar in both groups at five and ten years. Those with successfully healed fractures had more hip pain and reduction of mobility at four months compared with patients with an uncomplicated replacement, and they never attained a better outcome than the latter patients regarding pain or function.

Primary replacement gave reliable long-term results in patients with a displaced fracture of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 143 - 144
1 Feb 2011
Horan FT


Bone & Joint Research
Vol. 1, Issue 12 | Pages 315 - 323
1 Dec 2012
Molt M Ljung P Toksvig-Larsen S

Objectives

The objective of this study was to compare the early migration characteristics and functional outcome of the Triathlon cemented knee prosthesis with its predecessor, the Duracon cemented knee prosthesis (both Stryker).

Methods

A total 60 patients were prospectively randomised and tibial component migration was measured by radiostereometric analysis (RSA) at three months, one year and two years; clinical outcome was measured by the American Knee Society score and the Knee Osteoarthritis and Injury Outcome Score.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 616 - 621
1 May 2011
O’Neill F Condon F McGloughlin T Lenehan B Coffey JC Walsh M

We biomechanically investigated whether the standard dynamic hip screw (DHS) or the DHS blade achieves better fixation in bone with regard to resistance to pushout, pullout and torsional stability. The experiments were undertaken in an artificial bone substrate in the form of polyurethane foam blocks with predefined mechanical properties. Pushout tests were also repeated in cadaveric femoral heads. The results showed that the DHS blade outperformed the DHS with regard to the two most important characteristics of implant fixation, namely resistance to pushout and rotational stability.

We concluded that the DHS blade was the superior implant in this study.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1573 - 1578
1 Nov 2012
Lassen MR Gent M Kakkar AK Eriksson BI Homering M Berkowitz SD Turpie AGG

Post-operative complications after total hip or knee replacement can delay recovery, prolong hospitalisation, increase rates of re-admission and, in the most severe cases, lead to long-term disability or even death. In this analysis of pooled data from four large, randomised, phase III clinical trials that compared the oral, direct Factor Xa inhibitor rivaroxaban with subcutaneous enoxaparin for the prevention of venous thromboembolism after total hip or knee replacement (n = 12 729), the incidence of complications, including bleeding and adverse events related to surgery (such as wound infection, wound dehiscence and haemarthrosis) are reported. Interventions and procedures relating to surgery are also compared between the groups. Bleeding events, including excessive wound haematoma and surgical-site bleeding, occurred at similar rates in the rivaroxaban and enoxaparin groups. Over the total study duration, adverse surgical events occurred at a similar rate in the rivaroxaban group compared with the enoxaparin group after total knee replacement (2.26% vs 2.69%, respectively) and total hip replacement (1.48% vs 1.65%, respectively). Blood loss, wound drainage and transfusion requirements were also similar between the two groups.

This analysis shows that the incidence of adverse surgical events with rivaroxaban was similar to enoxaparin.